EF Logo

Volvo/Mack · MID 128 engine ECU - sensors and levels

Volvo/Mack Coolant level and coolant temperature sensors fault codes

The coolant level probe in the expansion tank tells the engine ECU when coolant is short, and the coolant temperature sensor in the coolant outlet tells it how hot the engine is for fan control, fuel timing and overheat protection. These MID 128 codes separate a real shortage or overheat from a wiring fault on either sensor.

FaultStopMID 128PID 110FMI 0Volvo/Mack · Coolant level and coolant temperature sensors
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Connect the Premium Tech Tool or a J1939/J1587 scan tool to the diagnostic socket and read the codes for every module, not only the engine.

What do these codes mean?

Volvo/Mack codes MID 128 PID 110 FMI 0 to MID 128 PID 111 FMI 5 are all about the coolant level and coolant temperature sensors. The most common failure type is real condition (3 of 9); 2 need an immediate stop. Start with this check: check the expansion tank level cold and pressure-test the cooling system to find any leak.

How urgent are they?

2 of 9 codes here mean stop now; the other 7 can wait until the shift ends, but find the cause before the next one.

  • Stop now2
  • Check soon7

What should I check first?

Check the expansion tank level cold and pressure-test the cooling system to find any leak

Shared checks

9 of 9

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Volvo/Mack MID 128 PID 110 FMI 0Engine coolant temperature critically high

    Coolant temperature reached the critical limit and the ECM is protecting the engine.· Real condition
    Stop now

    Causes

    • Coolant level low from a leak or a failed cap
    • Thermostat stuck closed or only partly opening
    • Fan not engaging, or the fan clutch/drive not responding to the ECM
    • Radiator or charge air cooler blocked with debris or scale
    • Coolant pump worn so flow is low at high load

    Checks

    1. 1Stop the engine and let it cool before opening anything; check coolant level and look for external leaks
    2. 2Check the fan engages when the engine is hot and the scan tool commands it
    3. 3Compare the radiator inlet and outlet temperatures with an infrared thermometer to see if the thermostat opens
    4. 4Inspect the front of the radiator and charge air cooler for packed dirt and bent fins
    5. 5Pressure test the system for internal leaks if coolant keeps disappearing without a visible leak
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Volvo/Mack MID 128 PID 110 FMI 2Engine coolant temperature signal erratic

    The coolant temperature reading jumps, disagrees with other temperatures or looks implausible.· Erratic or implausible
    Check soon

    Causes

    • Coolant temperature sensor failing intermittently
    • Loose or corroded terminal in the sensor connector
    • Thermostat stuck so the real coolant temperature really is erratic

    Checks

    1. 1Watch the live coolant temperature while the engine warms up; it should rise smoothly
    2. 2Compare it with intake manifold and oil temperature when the engine is cold after a long soak
    3. 3Wiggle the sensor connector and harness while watching for jumps in the value
    4. 4Replace the sensor if the value jumps with no change in real engine temperature
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Volvo/Mack MID 128 PID 110 FMI 4Engine coolant temperature sensor signal low or shorted to ground

    The coolant temperature signal voltage is below the valid range, which the ECM reads as a short to ground at the sensor or in its wiring.· Shorted low
    Check soon

    Causes

    • Coolant temperature sensor shorted internally
    • Signal wire chafed to ground along the front of the engine
    • Water in the sensor connector bridging signal to ground

    Checks

    1. 1Read the live temperature; an unrealistically cold value on a hot engine confirms the fault
    2. 2Unplug the sensor: the value should swing to its open-circuit default; if it stays low, the harness is shorted
    3. 3Check the signal wire for a short to ground with the key off
    4. 4Inspect the connector for water or coolant and dry it or replace it
    5. 5Replace the sensor if the harness tests good and confirm the code does not return
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Volvo/Mack MID 128 PID 110 FMI 5Engine coolant temperature sensor circuit open

    The coolant temperature sensor circuit is open.· Open circuit
    Check soon

    Causes

    • Broken signal or return wire in the engine harness
    • Sensor connector unplugged after service or a pin pushed out
    • Coolant temperature sensor open internally

    Checks

    1. 1Read the live coolant temperature; a fixed value regardless of engine heat points to an open
    2. 2Check the connector is fully locked and the pins are tight
    3. 3Test continuity of both sensor wires back to the ECM
    4. 4Replace the sensor after the wiring checks out
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Volvo/Mack MID 128 PID 110 FMI 16Engine coolant temperature moderately high

    Coolant temperature is above its upper limit but not yet at the critical level.· Real condition
    Check soon

    Causes

    • Thermostat opening late or sticking part way
    • Fan or fan control not working at full effect
    • Blocked radiator core or restricted airflow in front of it
    • Low coolant level or air trapped in the system

    Checks

    1. 1Watch coolant temperature in the scan tool during a load test and note when the fan engages
    2. 2Check coolant level and condition, and look for oil or exhaust gas in the coolant
    3. 3Clean the radiator and charge air cooler fins from the engine side outward
    4. 4Test the thermostat by feeling the upper hose warm up near the opening temperature
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Volvo/Mack MID 128 PID 111 FMI 1Engine coolant level critically low

    The coolant level sensor says the coolant is critically below the allowed range.· Real condition
    Stop now

    Causes

    • Coolant lost through a hose, radiator, heater core or water pump seal
    • Head gasket or EGR cooler leak pushing coolant out of the system
    • Level sensor wiring shorted so the ECU thinks the tank is empty

    Checks

    1. 1Shut down and check the surge tank when cold; add coolant only after finding the loss
    2. 2Inspect hoses, clamps, the water pump weep hole and the radiator for fresh leaks
    3. 3Pressure test the system and look for coolant in the oil or white smoke that suggests an internal leak
    4. 4If the tank is full, check the level sensor and its wiring before assuming the loss is real
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Volvo/Mack MID 128 PID 111 FMI 3Coolant level sensor circuit shorted to positive

    The ECM sees the coolant level sensor signal pulled high, which Mack ties to a short to positive on the measuring line.· Shorted high
    Check soon

    Causes

    • Measuring wire touching a supply wire in the harness
    • Coolant level sensor failed shorted
    • Damaged connector on the surge tank sensor

    Checks

    1. 1Look at the surge tank sensor connector for damage and coolant intrusion
    2. 2Unplug the sensor and check the signal wire for voltage with the key on
    3. 3Check for a short to a supply wire along the harness
    4. 4Replace the sensor if the harness tests normal
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Volvo/Mack MID 128 PID 111 FMI 4Coolant level sensor circuit shorted to ground

    The coolant level sensor signal is pulled low, which Mack ties to a short to ground on the measuring line.· Shorted low
    Check soon

    Causes

    • Level sensor shorted internally
    • Measuring wire chafed to ground near the surge tank
    • Corroded sensor connector

    Checks

    1. 1Read the coolant level status in the scan tool and compare it with the real level in the surge tank
    2. 2Unplug the level sensor and test the signal wire to ground with the key off
    3. 3Inspect the harness at the surge tank bracket for rub-through
    4. 4Replace the level sensor if the harness tests good
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Volvo/Mack MID 128 PID 111 FMI 5Coolant level sensor circuit open

    An open circuit on the coolant level sensor wiring means the ECM gets no level signal at all.· Open circuit
    Check soon

    Causes

    • Broken wire between the surge tank sensor and the ECM
    • Connector at the tank not seated or pin pushed back
    • Level sensor open internally

    Checks

    1. 1Check the live level status; none or a fixed state suggests an open circuit
    2. 2Test wire continuity from the sensor plug to the ECM connector with the key off
    3. 3Reseat the surge tank connector and inspect the terminals for green corrosion
    4. 4Replace the level sensor if the wiring checks good
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

Shared checks

Checks, in order

  1. 1Check the expansion tank level cold and pressure-test the cooling system to find any leak
  2. 2Compare the gauge with an infrared reading on the thermostat housing to tell a real overheat from a sensor fault
  3. 3Inspect the probe connector at the tank and the temperature sensor plug for corrosion and a loose latch
  4. 4Measure the level probe signal wire for a short to positive, a short to ground or an open circuit
  5. 5Measure the temperature sensor resistance at a known temperature against service data and wiggle the harness while watching for jumps
  6. 6Clear the codes after topping up and watch that the level and temperature readings follow the engine

Causes

  • Coolant lost through a hose, radiator, heater or water pump leak
  • Overheating from a weak water pump, stuck thermostat or blocked radiator core
  • Level probe in the tank coated, or temperature sensor failed with corroded pins
  • Open, chafed or shorted wire in the probe or sensor harness

Most common here: real condition (3 of 9)

Check the real value with a separate gauge or thermometer before blaming the sensor.

When to stop

You'll notice: The cluster shows a low coolant warning, or the temperature gauge reads too high, too low or jumps and the fan may run constantly.

Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.