J1939 · Aftertreatment - SCR/DEF
SPN 4374 Fault Code
Aftertreatment diesel exhaust fluid pump motor speed
What does SPN 4374 mean?
Speed of the DEF pump motor in the dosing unit. The control uses it to hold DEF line pressure and to detect pump or line problems. How urgent it is depends on the FMI after SPN 4374 - pick it below. Check first: check the DEF tank level and for ice, then run the pump prime test.
- SPN 4374
- Aftertreatment diesel exhaust fluid pump motor speed
- FMI ?
- How it failed - the number after the SPN
Can I keep running with it?
Depends on the FMI
How urgent it is depends on the FMI after SPN 4374 - pick it below.
What should I check first?
Check the DEF tank level and for ice, then run the pump prime test
Then 4 more checksWhere to read it
Connect a J1939-capable scan tool to the 9-pin diagnostic port.
Which FMI shows after SPN 4374?
You'll notice: The DEF pump is running at the wrong speed, so the system cannot hold dosing pressure.
Find the number shown after SPN 4374 on your display. 2 of them have their own page with causes and checks.
- 0SPN 4374 FMI 0: The DEF system is under-pressurisedReal conditionDetroit DD15, Detroit DD13, Detroit DD13 Gen 5, Detroit DD15 Gen 5
- 1SPN 4374 FMI 1: Value is below the normal range, most severe levelReal conditionMack MP8, Mack MP7, Volvo D13
- 3SPN 4374 FMI 3: DEF pump speed signal is above the measurement rangeShorted highDetroit DD15, Detroit DD13, Detroit DD13 Gen 5, Detroit DD15 Gen 5
- 4SPN 4374 FMI 4: DEF pump speed signal is below the measurement rangeShorted lowDetroit DD15, Detroit DD13, Detroit DD13 Gen 5, Detroit DD15 Gen 5
- 9SPN 4374 FMI 9: The DEF pump control loop reports an errorLost messageDetroit DD15, Detroit DD13, Detroit DD13 Gen 5, Detroit DD15 Gen 5
- 11SPN 4374 FMI 11: The DEF pump control loop reports an error with pump speed lowOtherDetroit DD15, Detroit DD13, Detroit DD13 Gen 5, Detroit DD15 Gen 5
- 14SPN 4374 FMI 14: The DEF pump control loop reports an error with pump speed highOtherDetroit DD15, Detroit DD13, Detroit DD13 Gen 5, Detroit DD15 Gen 5
Checks
0 of 5 done
When to stop
Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.
How urgent SPN 4374 is depends on its FMI and whether the engine has derated. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Causes
- Pump motor worn, seized or its drive circuit faulty
- Blocked DEF filter or frozen line making the pump work too hard or run dry
- Air in the DEF line from a low tank or a leak
- Pump speed signal or its wiring faulty
Other Aftertreatment - SCR/DEF codes
Source
Cummins ISX15 2013-2018 fault codes list (Diesel Laptops)
This list names SPN 4374 and the FMIs above for the engines it covers. The guidance on this page is general, not taken from it.
The source covers: Cummins ISX15 (2013-2018) and X15; same SPN on other J1939 engines.
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?