Kubota · Loader controller (E:0xx)
Kubota Loader hydraulic controls and solenoids fault codes
This page covers the loader controller hydraulic outputs and inputs: auxiliary hydraulic controls, hydraulic lock solenoids, forward detection pressure sensors, hydraulic oil temperature, and the high-speed, high-flow, quick-hitch, ride control and float mode circuits. The auxiliary hydraulic circuit feeds attachments such as hammers, augers and mulchers.
More about these partsLess
The loader locks the boom and bucket hydraulics with solenoid valves when the operator leaves the seat or lifts the safety bar. A pressure sensor on each side of the travel circuit tells the controller when the wheels or tracks on that side are driving forward. A temperature sensor in the hydraulic circuit reports the oil temperature to the loader controller.
Where this code shows
Watch the meter panel: a warning lamp comes on and the E: code scrolls on the display.
What do these codes mean?
Kubota codes E:004 to E:037 are all about the loader hydraulic controls and solenoids. The most common failure type is short circuit (3 of 16); 1 needs an immediate stop. Start with this check: read the code in Diagmaster and note whether it is active or only stored before touching any connector.
How urgent are they?
1 of 16 codes here means stop now; the other 15 can wait until the shift ends, but find the cause before the next one.
- Stop now1
- Check soon15
What should I check first?
Read the code in Diagmaster and note whether it is active or only stored before touching any connector
Shared checks16 of 16
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Kubota E:004Hydraulic oil temperature advance warning
The hydraulic oil temperature is climbing toward its limit and the loader warns you before it gets there. If work continues the code moves on to E:005 and the machine starts protecting itself.· OtherOtherCheck soonCauses
- Oil cooler fins packed with dirt, chaff or debris
- Cooling fan or its speed solenoid not reaching full speed
- Hydraulic oil level low or oil too thin after a long hot shift
- Circuit relieving constantly because an attachment is held at the end of its stroke
Checks
- 1Park, idle the engine and inspect the cooler core from both sides; blow out any packed debris with air
- 2Check the hydraulic tank level on the sight gauge with the arms lowered and the bucket flat
- 3Watch the fan at idle and at full throttle; it should speed up as the oil warms
- 4Compare the meter value against an infrared thermometer on the tank to rule out a bad sensor
- 5Avoid holding auxiliary or lift functions at relief while you test
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Kubota E:005Hydraulic oil temperature reached specified level
The hydraulic oil has reached the temperature limit. The controller now protects the pump and valves, and the machine will not give full performance until the oil cools.· OtherOtherStop nowCauses
- Cooler core blocked outside or sludged inside
- Cooling fan or its speed-control solenoid not working
- Oil level low so the pump cavitates and heats the oil
- Circuit relieving continuously through a stuck valve or overloaded attachment
Checks
- 1Lower the arms, idle without load and note how quickly the temperature falls
- 2Clean the oil cooler and radiator stack and confirm the fan turns at the expected speed
- 3Check the oil level and the condition of the oil and return filter; milky or burnt oil means a cause must be found
- 4Compare the display with a surface thermometer on the hydraulic tank to test the sensor
- 5Inspect the attachment for a stuck coupler or kinked hose forcing constant relief
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Kubota E:010High-speed switching system error
The circuit that switches the travel motors between low and high speed is faulty. The loader may stay in one speed range because the controller cannot trust the changeover.· OtherOtherCheck soonCauses
- Travel speed solenoid coil open or shorted
- Wire or connector fault at the high-speed solenoid
- High-speed switch on the control panel worn out
- Travel motor displacement valve sticking
Checks
- 1Operate the switch and listen or feel for the solenoid clicking at the valve
- 2Measure the solenoid coil resistance with the connector unplugged and compare it with a sister solenoid
- 3Check the solenoid supply and signal wires back to the controller for open or short
- 4Test the cab switch contacts with a meter in both positions
- 5Swap in a known good solenoid or clean the valve cartridge if the coil is healthy
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Kubota E:014High-flow system error
The circuit that raises auxiliary hydraulic flow on high-flow machines is faulty. The loader can run but high-flow attachments will not get full flow.· Lost messageLost messageCheck soonCauses
- High-flow solenoid coil open or shorted
- Wiring or connector fault at the high-flow valve
- High-flow switch failed
- Flow control spool sticking from contaminated oil
Checks
- 1Press the high-flow switch and listen for the solenoid to click
- 2Measure the coil resistance of the high-flow solenoid and compare it with the service manual value
- 3Check for voltage at the solenoid plug while the switch is on
- 4Inspect the harness for rubbing near the auxiliary valve block
- 5Check the return filter and oil condition for contamination before replacing the valve
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Kubota E:015Hydraulic quick-hitch system error
The controller detected a fault in the electrically controlled hydraulic quick-hitch circuit. The attachment lock may not operate as commanded.· OtherOtherCheck soonCauses
- Quick-hitch solenoid coil open or shorted
- Damaged wire to the coupler valve
- Quick-hitch switch in the cab worn
- Coupler cylinder or hose leaking pressure
Checks
- 1Operate the quick-hitch switch and listen for the solenoid to click at the valve
- 2Measure the solenoid coil resistance with the plug removed
- 3Check supply voltage at the solenoid connector while the switch is held
- 4Test the cab switch contacts and its connector
- 5Look for hose leaks or a stuck coupler cylinder if the electrical tests pass
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Kubota E:016Auxiliary hydraulic control error (knob control switch)
The knob or thumb control that proportionally operates the auxiliary hydraulics is sending a bad signal. The controller ignores the input until it gets a valid one.· OtherOtherCheck soonCauses
- Knob control switch contact worn or dirty
- Open or shorted wire between the joystick knob and controller
- Joystick connector corroded after pressure washing
- Potentiometer inside the knob failed
Checks
- 1Wiggle the joystick harness and watch the signal in Diagmaster for dropouts
- 2Measure the knob signal at the controller connector in each position
- 3Check the joystick connector for water and pushed-back pins
- 4Compare with the centre value, which should be steady with the knob released
- 5Replace the knob or switch if the signal is noisy or stuck
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Kubota E:018Auxiliary hydraulic control error (rightward switch solenoid valve)
The solenoid that sends auxiliary flow to the right-hand side of the auxiliary circuit is faulty. Auxiliary function in that direction is limited until the fault clears.· OtherOtherCheck soonCauses
- Rightward auxiliary solenoid coil open or shorted
- Wire fault between solenoid and controller
- Valve spool sticking
Checks
- 1Command the auxiliary to the right and listen for the solenoid to click
- 2Measure the coil resistance of this solenoid and compare it with the leftward one
- 3Check for supply voltage at the plug when the command is active
- 4Inspect the harness at the valve block for rubbing and heat damage
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Kubota E:019Auxiliary hydraulic control error (leftward switch solenoid valve)
The solenoid that sends auxiliary flow to the left-hand side of the auxiliary circuit is faulty. The attachment will not work in that direction.· OtherOtherCheck soonCauses
- Leftward auxiliary solenoid coil failed open or shorted
- Chafed wire between controller and solenoid
- Dirt in the valve cartridge holding the spool
Checks
- 1Command the auxiliary to the left and feel or listen for the solenoid actuating
- 2Measure the coil resistance and compare it with the matching rightward solenoid
- 3Back-probe the solenoid connector for a command voltage when the switch is pressed
- 4Inspect the connector for water and bent pins
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Kubota E:024Hydraulic oil temperature sensor error
The hydraulic oil temperature sensor signal is out of range or missing. With no valid reading the controller keeps travel speed low to protect the hydraulic system.· OtherOtherCheck soonCauses
- Oil temperature sensor open or shorted
- Damaged wire or connector at the sensor
- Sensor supply or ground fault
- Sensor failed from vibration and heat
Checks
- 1Read the oil temperature in Diagmaster and compare it with a surface thermometer on the tank
- 2Unplug the sensor and measure its resistance; it should change with temperature, not read open or zero
- 3Check the sensor wires for continuity and for a short to ground
- 4Clean the connector and look for bent or corroded terminals
- 5Replace the sensor if its resistance does not follow temperature
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Kubota E:027Ride control solenoid broken or short-circuited
The ride control solenoid circuit is open or shorted. Ride control (boom cushioning while travelling) will not work normally.· Open circuitOpen circuitCheck soonCauses
- Ride control solenoid coil open or shorted
- Chafed wire to the solenoid
- Connector at the boom valve corroded
- Ride control switch fault
Checks
- 1Switch ride control on and listen for the solenoid
- 2Measure the coil resistance with the connector off
- 3Check the solenoid feed for voltage when ride control is on
- 4Inspect the harness at the boom valve for chafing
- 5Replace the coil if its resistance reads open or near zero
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Kubota E:029Hydraulic lock solenoid (arm) broken or short-circuited
The solenoid for the hydraulic lock of the arm is open or shorted. The source also lists the same number for an acceleration system fault. The hydraulic lock solenoid stops working, so the lock may not release or engage.· Short circuitShort circuitCheck soonCauses
- Open or chafed solenoid wire near the boom
- Burnt solenoid coil
- Corroded solenoid connector
Checks
- 1Measure the arm lock solenoid coil resistance
- 2Check the wires and connector from the controller to the solenoid
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.
Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.
Kubota E:030Hydraulic lock solenoid (bucket) broken or short-circuited
The solenoid for the hydraulic lock of the bucket is open or shorted, so it stops working. The source lists the same number a second time for a broken ECU CAN communication cable, in which case travel speed stays low.· Lost messageLost messageCheck soonCauses
- Open or chafed solenoid wire near the boom
- Burnt solenoid coil
- Corroded solenoid connector or CAN wire broken
Checks
- 1Measure the bucket lock solenoid coil resistance
- 2Check the solenoid wires and, for the CAN case, the CAN wires to the engine ECU
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Kubota E:031High-speed mode pressure sensor broken or short-circuited
The pressure sensor used for high-speed travel mode has an open or shorted circuit. The loader will not engage high-speed mode reliably while this is active.· Short circuitShort circuitCheck soonCauses
- High-speed pressure sensor internal failure
- Open or shorted sensor wire
- 5 V supply or ground fault at the sensor
- Corroded sensor connector
Checks
- 1Back-probe the sensor connector for the 5 V supply and ground with key on
- 2Read the sensor signal in Diagmaster; it should sit within about 0.5-4.5 V and move with pressure
- 3Check the signal wire for continuity back to the controller and for a short
- 4Inspect the connector for water and pushed-back pins
- 5Replace the sensor if the signal is flat or pinned to a rail
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.
Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.
Kubota E:032Float mode selector solenoid cable broken or short-circuited
The solenoid for arm float mode is open or shorted. Float mode will not engage and lowering the arms may not behave as you expect.· Short circuitShort circuitCheck soonCauses
- Float solenoid coil failed
- Wire fault between solenoid and controller
- Float switch failure
- Connector fault at the lift valve
Checks
- 1Select float with key on and listen for the solenoid at the lift valve
- 2Measure the coil resistance with the plug removed and compare it with the other solenoids
- 3Check for command voltage at the plug when float is selected
- 4Inspect the harness at the lift valve for rubbing and heat damage
- 5Test the float switch contacts with a meter in both positions
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.
Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.
Kubota E:036Forward detection pressure sensor (right) cable broken
The right-hand forward-travel detection pressure sensor has a broken signal cable. The drive system cannot read forward pressure on the right travel circuit.· OtherOtherCheck soonCauses
- Right forward pressure sensor open circuit
- Harness break near the right travel motor
- Sensor connector loose
Checks
- 1Read the right forward sensor in Diagmaster and compare it with the left value while driving
- 2Back-probe the sensor connector for 5 V supply, ground and signal
- 3Follow the harness along the right side frame looking for breaks and clamps that have cut in
- 4Inspect the connector for corrosion and spread terminals
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Kubota E:037Forward detection pressure sensor (left) cable broken
The left-hand forward-travel detection pressure sensor has a broken signal cable. The drive system cannot read forward pressure on the left travel circuit.· OtherOtherCheck soonCauses
- Open signal wire inside the left travel motor harness
- Left sensor body cracked by hose or frame contact
- Left sensor connector backed out of its socket
Checks
- 1Drive the loader slowly forward and read the left forward sensor in Diagmaster; compare it with the right one
- 2Back-probe the left sensor connector for the 5 V supply, ground and signal
- 3Check the left side harness and hoses for a wire crushed under a clamp or cut by a hose
- 4Look at the left connector for corrosion and spread terminals
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Shared checks
Checks, in order
- 1Read the code in Diagmaster and note whether it is active or only stored before touching any connector
- 2Read the code and cycle the safety bar to hear whether the solenoid clicks
- 3Check the sensor connector on the affected side for water and corrosion
- 4Clean the oil cooler and radiator fins from both sides and look for oil weeping from the cooler
- 5Run the auxiliary function in both directions and note which side fails to respond
- 6Measure the coil resistance at the solenoid and compare it with the other lock solenoid
- 7Measure the sensor supply and signal at the connector with the key on
Causes
- Solenoid cable broken or shorted on the high-flow, quick-hitch, ride control or float circuit
- Water or corrosion in the joystick or solenoid connectors after pressure washing
- Water or corrosion in the solenoid connector at the valve block
- Broken or chafed sensor wire near the travel motor
Most common here: short circuit (3 of 16)
Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.
When to stop
You'll notice: The attachment will not run, runs in one direction only or cannot be controlled smoothly, with the E: code on the meter panel.
Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.