This page covers the loader controller inputs and drive functions outside the hydraulics: fuel sensor, acceleration, parking brake, travel torque management, the 5 V sensor supply, jump starting with a 24 V battery, the cooling fan solenoid and the controller CAN link. The hydraulic cooling fan speed is set by a proportional solenoid that the loader controller drives from the oil and coolant temperatures.
More about these partsLess
The loader controller talks to the engine ECU and the meter panel over a CAN bus, a twisted pair of wires.
Where this code shows
Watch the meter panel: a warning lamp comes on and the E: code scrolls on the display.
What do these codes mean?
Kubota codes E:001 to E:028 are all about the loader controller supply, drive and fan. Most are lost message faults; 2 need an immediate stop. Start with this check: watch the fan and note whether it runs at full speed or not at all.
How urgent are they?
2 of 10 codes here mean stop now; the other 8 can wait until the shift ends, but find the cause before the next one.
- Stop now2
- Check soon8
What should I check first?
Watch the fan and note whether it runs at full speed or not at all
Shared checks10 of 10
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Kubota E:001CAN communication error
The loader's main controller and another unit on the CAN bus (meter panel, engine ECU or valve controller) stopped exchanging data. While the bus is down, functions that rely on shared data can drop out or fall back to a safe mode.· Lost messageLost messageCheck soonCauses
- Chafed or broken CAN-H / CAN-L twisted pair in the main harness
- Water or corrosion inside a controller connector
- Terminating resistor at one end of the bus missing or open
- Weak battery resetting a controller during cranking
Checks
- 1Key off and measure resistance across CAN-H and CAN-L at the diagnostic connector; a healthy bus with two terminators reads about 60 ohms
- 2Wiggle the harness at hinge points and near the engine ECU plug while watching whether the code returns
- 3Unplug each controller connector in turn and inspect for pushed-back pins, green corrosion and water
- 4Check battery voltage at rest and while cranking, since a weak battery can drop controllers off the bus
- 5Connect Kubota Diagmaster and see which controller is missing from the network list
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Kubota E:008Fuel sensor system error
The controller sees an abnormal signal from the fuel level sensor circuit. The fuel gauge cannot be trusted while the code is active, so fuel level has to be checked by eye.· OtherOtherCheck soonCauses
- Fuel level sender float arm stuck or resistance track worn
- Open or shorted sender wire between tank and meter
- Corroded sender connector at the top of the tank
- Poor ground at the sender mounting
Checks
- 1Look in the tank and note the real fuel level against what the gauge shows
- 2Unplug the sender and measure its resistance while moving the float through its range; it should change smoothly without gaps
- 3Check the sender signal wire for continuity to the controller and for a short to the tank
- 4Clean and re-seat the sender connector and check its ground
- 5Replace the sender if the track is open or the float no longer moves freely
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Kubota E:009Acceleration system error
The throttle command path (accelerator dial or pedal sensor and its signal to the engine ECU) is out of range or channels disagree. Engine speed control can be limited as a result.· Lost messageLost messageCheck soonCauses
- Accelerator sensor signal out of range
- Broken or shorted signal wire to the engine ECU
- Connector at the engine ECU not fully seated
- 5 V sensor supply pulled down by a shorted sensor
Checks
- 1Sweep the dial or pedal with key on while reading its value in Diagmaster and look for jumps or dead zones
- 2Back-probe the sensor: expect about 5 V on the reference and a signal that rises smoothly between roughly 0.5 and 4.5 V
- 3Inspect the connector at the sensor and engine ECU for pushed-back or corroded pins
- 4Check the wires for chafing where they pass the engine and frame
- 5Look for E:021 or E:9109 stored with it, which would point at the sensor supply
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Kubota E:011Parking brake system error
The controller found a fault in the parking brake circuit (release solenoid or switch). Because the brake must release hydraulically before the machine will drive, this can leave the loader immobile.· Lost messageLost messageStop nowCauses
- Parking brake release solenoid coil open or shorted
- Brake release pressure not building because of a stuck valve
- Damaged wire or connector to the brake solenoid
- Brake status switch failed
Checks
- 1With the safety bar down and key on, listen for the brake solenoid to click when the brake should release
- 2Measure coil resistance of the brake solenoid with its connector unplugged
- 3Back-probe the solenoid connector for supply voltage when release is commanded
- 4Inspect the harness and the brake status switch plug for water and chafing
- 5Check the brake release pressure with a gauge if the electrical side is good
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Kubota E:020Electronic travel torque management system error
The system that manages drive torque electronically (travel pump control) reports a problem. The controller may limit travel performance to protect the drive system.· OtherOtherCheck soonCauses
- Travel pump control solenoid or its wiring faulty
- Travel pressure sensor signal out of range
- Controller data missing over CAN
- Low supply voltage to the travel control valves
Checks
- 1Read live travel data in Diagmaster and compare left and right drive commands
- 2Measure the travel pump control solenoid resistance on both sides
- 3Check the travel pressure sensors for a signal inside the expected 0.5-4.5 V range
- 4Look for E:001 or E:021 stored alongside, which could be the real cause
- 5Check battery and charging voltage while driving
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Kubota E:021Sensor 5 V power supply short-circuited
One of the loader's 5 V sensor supply lines is shorted, so every sensor sharing that supply gets a wrong reference. Several sensor codes can appear together because of this.· Lost messageLost messageCheck soonCauses
- A sensor internally shorted on the 5 V reference
- Harness pinched or chafed so the 5 V wire touches ground
- Water in a sensor connector
- Wiring damage after earlier repair work
Checks
- 1Measure the 5 V reference at the controller connector with key on; it should read about 5 V, not near 0
- 2Unplug sensors one at a time and see which one restores the supply
- 3Inspect harness runs near hinges and sharp edges for a 5 V wire touching metal
- 4Check connectors on the pressure, temperature and position sensors for moisture
- 5Replace the shorted sensor or repair the harness once identified
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Kubota E:022Fan rpm control solenoid valve cable broken
The solenoid that controls the hydraulic cooling fan speed has an open circuit. The fan may run at a fixed speed instead of following temperature, so cooling can suffer.· Open circuitOpen circuitCheck soonCauses
- Fan speed solenoid coil open
- Broken wire or loose connector at the fan valve
- Fan valve spool stuck
Checks
- 1Locate the fan speed solenoid, unplug it and measure the coil resistance for an open circuit
- 2Check the two wires back to the controller for continuity
- 3Inspect the plug for pushed-back pins and water
- 4Verify the fan responds when the temperature rises
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Kubota E:023Jump start with a 24 V battery or improper device
The controller sees an overvoltage consistent with a 24 V jump start or an improper charger. Electronics can be damaged, so the machine reports the condition right away.· Lost messageLost messageStop nowCauses
- Loader jumped from a 24 V system
- Charger or booster connected incorrectly
- Alternator regulator producing overvoltage
- Battery cables connected in reverse polarity
Checks
- 1Measure battery voltage at rest and with the engine running; a 12 V system should not go above about 15 V
- 2Find out what was used for the jump start and how it was connected
- 3Inspect the main fuses and fusible links for blown elements
- 4Check the alternator output and regulator behaviour
- 5Scan for other stored codes that may have been set by the overvoltage event
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Kubota E:026CRS CAN communication error
The common rail system (engine ECU) is not communicating with the main machine controller on CAN. The loader cannot share engine data with the meter or controller.· Lost messageLost messageCheck soonCauses
- Open or shorted CAN wires between engine ECU and machine controller
- Engine ECU connector pins corroded
- Terminating resistor missing or open
- Engine ECU powered improperly (main relay or fuse)
Checks
- 1Measure the CAN-H/CAN-L resistance at the diagnostic connector
- 2Check the engine ECU power supply and main relay fuse for voltage
- 3Inspect the engine ECU connector for water ingress and pin damage
- 4Look for a CAN wire pinched at the engine harness clamps
- 5Use Diagmaster to confirm whether the engine ECU is answering
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Kubota E:028Fan solenoid broken or short-circuited
The fan solenoid circuit has an open or short, so the fan cannot be controlled correctly. Cooling can be reduced as a result.· Lost messageLost messageCheck soonCauses
- Fan solenoid coil open or shorted to ground
- Wire damage on the engine-side harness
- Fan valve plug corroded
Checks
- 1Unplug the fan solenoid and measure its resistance against the manual value
- 2Check each wire for a short to the machine frame
- 3Look at the plug for green corrosion and spread terminals
- 4Check the controller output with a test light while commanded
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Shared checks
Checks, in order
- 1Watch the fan and note whether it runs at full speed or not at all
- 2Measure the resistance between CAN-H and CAN-L at the diagnostic connector with the key off
- 3Measure the solenoid coil resistance and compare it with the service data
- 4Wiggle the harness at hinge points while watching whether the code returns
- 5Check the solenoid wire for continuity and for a short to ground
- 6Check the battery voltage at rest and while cranking
- 7Inspect the solenoid connector and the controller connector for corrosion
Causes
- Parking brake or fuel sensor wiring damaged
- Fan solenoid connector corroded or loose
- Chafed or broken CAN-H / CAN-L wire
- 5 V sensor supply shorted by a failed sensor
Most codes here: lost message (7 of 10)
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
When to stop
You'll notice: The fan runs flat out or at the wrong speed and the machine may run hot, with the E: code on the meter.
Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.