Komatsu · Pump controller

Komatsu Travel speed, swing brake and relief solenoids fault codes

These on-off solenoids switch the travel speed, hold the swing brake, join the travel circuits, supply a spare circuit and switch the second-stage overflow (relief) valve. The pump controller drives each coil and reports a circuit break (KA) or a short (KB).

FaultCheckDW43KAKomatsu · Travel speed, swing brake and relief solenoids
Code shows hereFAULTDW43KA

Where this code shows

Watch the monitor for the user code and the caution lamp or buzzer, and write the code down.

What do these codes mean?

Komatsu codes DWK0KA to DW91KB are all about the travel speed, swing brake and relief solenoids. The most common failure type is open circuit (5 of 10); none needs an immediate stop. Start with this check: inspect the solenoid connector for water and corrosion.

How urgent are they?

None of the 10 codes here means stop now; all 10 can wait until the shift ends, but find the cause before the next one.

  • Check soon10

What should I check first?

Inspect the solenoid connector for water and corrosion

Shared checks

10 of 10

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Komatsu DWK0KASecond-stage overflow (relief) solenoid: circuit open

    The pump controller finds the second-stage overflow (relief) solenoid circuit open, so no current can flow through the coil.· Open circuit
    Check soon

    Causes

    • Broken wire or loose pin between the pump controller and the second-stage overflow (relief) solenoid
    • Open coil inside the second-stage overflow (relief) solenoid
    • Second-stage overflow (relief) solenoid valve cartridge sticking from dirty oil

    Checks

    1. 1Key off, unplug the second-stage overflow (relief) solenoid and measure the coil resistance; an open reading condemns the coil
    2. 2Operate the function with the engine running and see whether the solenoid clicks
    3. 3Find the second-stage overflow solenoid on the main control valve and check its plug first.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Komatsu DWK0KBSecond-stage overflow (relief) solenoid: circuit short

    The pump controller finds the second-stage overflow (relief) solenoid circuit shorted, so the coil is no longer limiting current.· Other
    Check soon

    Causes

    • Harness wire to the second-stage overflow (relief) solenoid rubbed through and touching ground or another feed
    • Shorted turns or water inside the second-stage overflow (relief) solenoid coil
    • Second-stage overflow (relief) solenoid valve cartridge sticking from dirty oil

    Checks

    1. 1Unplug the second-stage overflow (relief) solenoid and measure each wire to ground; any continuity means the harness is shorted
    2. 2Operate the function with the engine running and see whether the solenoid clicks
    3. 3Find the second-stage overflow solenoid on the main control valve and check its plug first.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Komatsu DWA2KABackup solenoid: circuit open

    The pump controller finds the backup solenoid circuit open, so no current can flow through the coil.· Open circuit
    Check soon

    Causes

    • Broken wire or loose pin between the pump controller and the backup solenoid
    • Open coil inside the backup solenoid
    • Backup solenoid valve cartridge sticking from dirty oil

    Checks

    1. 1Key off, unplug the backup solenoid and measure the coil resistance; an open reading condemns the coil
    2. 2Operate the function with the engine running and see whether the solenoid clicks
    3. 3Find the backup solenoid on the valve block and check its plug first.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Komatsu DWA2KBBackup solenoid: circuit short

    The pump controller finds the backup solenoid circuit shorted, so the coil is no longer limiting current.· Other
    Check soon

    Causes

    • Harness wire to the backup solenoid rubbed through and touching ground or another feed
    • Shorted turns or water inside the backup solenoid coil
    • Backup solenoid valve cartridge sticking from dirty oil

    Checks

    1. 1Unplug the backup solenoid and measure each wire to ground; any continuity means the harness is shorted
    2. 2Operate the function with the engine running and see whether the solenoid clicks
    3. 3Find the backup solenoid on the valve block and check its plug first.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Komatsu DW43KATravel speed solenoid: circuit open

    The pump controller finds the travel speed solenoid circuit open, so the solenoid cannot change the travel motors between speeds.· Open circuit
    Check soon

    Causes

    • Travel speed solenoid connector loose or corroded
    • Open wire between the pump controller and the solenoid
    • Open coil in the travel speed solenoid
    • Pump controller output stage failed

    Checks

    1. 1Inspect the travel speed solenoid connector for water and loose pins
    2. 2Unplug the solenoid and measure the coil resistance; an open reading condemns the solenoid
    3. 3Measure continuity of both wires from the solenoid plug to the pump controller connector
    4. 4Operate the travel speed switch and see whether the solenoid clicks
    5. 5Check the travel speed switch and the monitor setting before replacing parts
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Komatsu DW43KBTravel speed solenoid: circuit short

    The pump controller finds the travel speed solenoid circuit shorted, so the coil is no longer limiting current.· Other
    Check soon

    Causes

    • Harness wire to the travel speed solenoid rubbed through and touching ground or another feed
    • Shorted turns or water inside the travel speed solenoid coil
    • Travel speed solenoid valve cartridge sticking from dirty oil

    Checks

    1. 1Unplug the travel speed solenoid and measure each wire to ground; any continuity means the harness is shorted
    2. 2Operate the function with the engine running and see whether the solenoid clicks
    3. 3Find the travel speed solenoid on the main control valve block and check its plug first.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Komatsu DW45KASwing brake solenoid: circuit open

    The pump controller finds the swing brake solenoid circuit open, so no current can flow through the coil.· Open circuit
    Check soon

    Causes

    • Broken wire or loose pin between the pump controller and the swing brake solenoid
    • Open coil inside the swing brake solenoid
    • Swing brake solenoid valve cartridge sticking from dirty oil

    Checks

    1. 1Key off, unplug the swing brake solenoid and measure the coil resistance; an open reading condemns the coil
    2. 2Operate the function with the engine running and see whether the solenoid clicks
    3. 3Find the swing brake solenoid on the swing motor or pilot block and check its plug first.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Komatsu DW45KBSwing brake solenoid: circuit short

    The pump controller finds the swing brake solenoid circuit shorted, so the coil is no longer limiting current.· Erratic or implausible
    Check soon

    Causes

    • Harness wire to the swing brake solenoid rubbed through and touching ground or another feed
    • Shorted turns or water inside the swing brake solenoid coil
    • Swing brake solenoid valve cartridge sticking from dirty oil

    Checks

    1. 1Unplug the swing brake solenoid and measure each wire to ground; any continuity means the harness is shorted
    2. 2Operate the function with the engine running and see whether the solenoid clicks
    3. 3Find the swing brake solenoid on the swing motor or pilot block and check its plug first.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Komatsu DW91KATravel junction solenoid: circuit open

    The pump controller finds the travel junction solenoid circuit open, so no current can flow through the coil.· Open circuit
    Check soon

    Causes

    • Broken wire or loose pin between the pump controller and the travel junction solenoid
    • Open coil inside the travel junction solenoid
    • Travel junction solenoid valve cartridge sticking from dirty oil

    Checks

    1. 1Key off, unplug the travel junction solenoid and measure the coil resistance; an open reading condemns the coil
    2. 2Operate the function with the engine running and see whether the solenoid clicks
    3. 3Find the travel junction solenoid on the main control valve and check its plug first.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Komatsu DW91KBTravel junction solenoid: circuit short

    The pump controller finds the travel junction solenoid circuit shorted, so the coil is no longer limiting current.· Other
    Check soon

    Causes

    • Harness wire to the travel junction solenoid rubbed through and touching ground or another feed
    • Shorted turns or water inside the travel junction solenoid coil
    • Travel junction solenoid valve cartridge sticking from dirty oil

    Checks

    1. 1Unplug the travel junction solenoid and measure each wire to ground; any continuity means the harness is shorted
    2. 2Operate the function with the engine running and see whether the solenoid clicks
    3. 3Find the travel junction solenoid on the main control valve and check its plug first.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

Shared checks

Checks, in order

  1. 1Inspect the solenoid connector for water and corrosion
  2. 2Measure the coil resistance and compare it with the shop manual value
  3. 3Check the wires to ground and between each other with the controller unplugged
  4. 4Operate the function and listen for the solenoid clicking
  5. 5Swap with a similar solenoid to see if the fault follows

Causes

  • Connector on the solenoid valve block loose or corroded
  • Wire rubbed through near the main control valve
  • Failed coil
  • Pump controller output stage failed

Most common here: open circuit (5 of 10)

Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

When to stop

You'll notice: Travel stays in one speed, the swing will not hold or release, or an attachment function fails, with the failure code (user code E03 for the swing brake in the SINOCMP table).

Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.