Komatsu Boost, intake air, coolant and ambient sensors fault codes

These sensors report manifold boost pressure, intake air temperature, coolant temperature and ambient (barometric) pressure to the engine controller. It uses them to adjust fuelling, start-up enrichment and altitude derating, and to protect the engine from overheating.

FaultCheckCA122Komatsu · Boost, intake air, coolant and ambient sensors
Code shows hereFAULTCA122

Where this code shows

Watch the monitor for the user code and the caution lamp or buzzer, and write the code down.

What do these codes mean?

Komatsu codes CA122 to CA488 are all about the boost, intake air, coolant and ambient sensors. The most common failure type is shorted high (4 of 10); none needs an immediate stop. Start with this check: check the sensor connector for water, oil and bent pins first.

How urgent are they?

None of the 10 codes here means stop now; all 10 can wait until the shift ends, but find the cause before the next one.

  • Check soon10

What should I check first?

Check the sensor connector for water, oil and bent pins first

Shared checks

10 of 10

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Komatsu CA122Inflation (boost) pressure sensor: high voltage

    The engine controller sees the inflation (boost) pressure sensor signal voltage above its allowed range and treats the reading as unusable.· Shorted high
    Check soon

    Causes

    • Signal wire of the inflation (boost) pressure sensor shorted to a 5 V or battery feed
    • Open ground return at the inflation (boost) pressure sensor, letting the signal float high
    • Failed boost pressure sensor reading above range

    Checks

    1. 1Unplug the inflation (boost) pressure sensor connector and measure the signal wire to ground with key on; a high reading with the sensor off points to the harness
    2. 2Check the sensor connector for oil and the boost pressure port for blockage
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Komatsu CA123Inflation (boost) pressure sensor: low voltage

    The engine controller sees the inflation (boost) pressure sensor signal voltage below its allowed range and discards the reading.· Shorted low
    Check soon

    Causes

    • Signal wire of the inflation (boost) pressure sensor shorted to ground or rubbed through on the engine harness
    • Open signal wire or a pin pushed back in the inflation (boost) pressure sensor connector
    • Failed boost pressure sensor reading below range

    Checks

    1. 1Unplug the inflation (boost) pressure sensor connector and measure the signal wire to ground; a near-zero reading with the sensor off means the harness is shorted
    2. 2Check the boost pressure line and port for a leak or blockage
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Komatsu CA144Coolant temperature sensor: high voltage

    The engine controller sees the coolant temperature sensor signal voltage above its allowed range and treats the reading as unusable.· Shorted high
    Check soon

    Causes

    • Signal wire of the coolant temperature sensor shorted to a 5 V or battery feed
    • Open ground return at the coolant temperature sensor, letting the signal float high
    • Coolant sensor open or failed, reading very cold

    Checks

    1. 1Unplug the coolant temperature sensor connector and measure the signal wire to ground with key on; a high reading with the sensor off points to the harness
    2. 2Compare the sensor reading in service mode with a warm engine; a cold reading after warm-up means an open sensor
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Komatsu CA145Coolant temperature sensor: low voltage

    The engine controller sees the coolant temperature sensor signal voltage below its allowed range and discards the reading.· Shorted low
    Check soon

    Causes

    • Signal wire of the coolant temperature sensor shorted to ground or rubbed through on the engine harness
    • Open signal wire or a pin pushed back in the coolant temperature sensor connector
    • Coolant sensor shorted, reading very hot

    Checks

    1. 1Unplug the coolant temperature sensor connector and measure the signal wire to ground; a near-zero reading with the sensor off means the harness is shorted
    2. 2Compare the sensor reading in service mode with a cold engine; a hot reading on a cold engine means a shorted sensor
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Komatsu CA153Inflation (intake air) temperature sensor: high voltage

    The engine controller sees the inflation (intake air) temperature sensor signal voltage above its allowed range and treats the reading as unusable.· Shorted high
    Check soon

    Causes

    • Signal wire of the inflation (intake air) temperature sensor shorted to a 5 V or battery feed
    • Open ground return at the inflation (intake air) temperature sensor, letting the signal float high
    • Intake air temperature sensor open or failed

    Checks

    1. 1Unplug the inflation (intake air) temperature sensor connector and measure the signal wire to ground with key on; a high reading with the sensor off points to the harness
    2. 2Check the intake air temperature reading on a cold engine; it should be close to ambient
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Komatsu CA154Inflation (intake air) temperature sensor: low voltage

    The engine controller sees the inflation (intake air) temperature sensor signal voltage below its allowed range and discards the reading.· Shorted low
    Check soon

    Causes

    • Signal wire of the inflation (intake air) temperature sensor shorted to ground or rubbed through on the engine harness
    • Open signal wire or a pin pushed back in the inflation (intake air) temperature sensor connector
    • Intake air temperature sensor shorted

    Checks

    1. 1Unplug the inflation (intake air) temperature sensor connector and measure the signal wire to ground; a near-zero reading with the sensor off means the harness is shorted
    2. 2Check the intake air temperature reading on a cold engine; it should be close to ambient
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Komatsu CA155Inflation (intake air) temperature high, derate stage 1

    The intake air temperature is above the first limit the controller allows.· Other
    Check soon

    Causes

    • Clogged charge air cooler or radiator fins
    • Cooling fan or fan drive not working properly
    • Hot air recirculating from the engine compartment
    • Failed intake air temperature sensor reading too high

    Checks

    1. 1Check the charge air cooler and radiator for dirt and bent fins
    2. 2Check the fan speed and drive against the cooling demand
    3. 3Compare the sensor reading with a measured intake air temperature
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Komatsu CA221Barometric (ambient) pressure sensor: high voltage

    The engine controller sees the barometric (ambient) pressure sensor signal voltage above its allowed range and treats the reading as unusable.· Shorted high
    Check soon

    Causes

    • Signal wire of the barometric (ambient) pressure sensor shorted to a 5 V or battery feed
    • Open ground return at the barometric (ambient) pressure sensor, letting the signal float high
    • Failed ambient pressure sensor in the controller or on the engine

    Checks

    1. 1Unplug the barometric (ambient) pressure sensor connector and measure the signal wire to ground with key on; a high reading with the sensor off points to the harness
    2. 2Check the sensor connector and compare the reading with the local air pressure
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Komatsu CA222Barometric (ambient) pressure sensor: low voltage

    The engine controller sees the barometric (ambient) pressure sensor signal voltage below its allowed range and discards the reading.· Shorted low
    Check soon

    Causes

    • Signal wire of the barometric (ambient) pressure sensor shorted to ground or rubbed through on the engine harness
    • Open signal wire or a pin pushed back in the barometric (ambient) pressure sensor connector
    • Failed ambient pressure sensor in the controller or on the engine

    Checks

    1. 1Unplug the barometric (ambient) pressure sensor connector and measure the signal wire to ground; a near-zero reading with the sensor off means the harness is shorted
    2. 2Check the sensor connector and compare the reading with the local air pressure
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Komatsu CA488Inflation (intake air) temperature high, torque decrease

    The intake air temperature is above the higher limit, so the controller cuts engine torque.· Other
    Check soon

    Causes

    • Charge air cooler core blocked outside or inside
    • Fan belt or fan drive slipping
    • Turbocharger outlet hose leaking and heating the intake
    • Failed intake air temperature sensor

    Checks

    1. 1Inspect the charge air cooler and hoses for leaks and clogging
    2. 2Check that the radiator fan runs at the expected speed under load
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

Shared checks

Checks, in order

  1. 1Check the sensor connector for water, oil and bent pins first
  2. 2Unplug the sensor and compare the signal wire voltage with key on against the other fault direction
  3. 3Compare the reading in monitor service mode with a known temperature, such as a cold engine against ambient
  4. 4Inspect the sensor wiring from plug to controller for rubbed insulation
  5. 5Clear the code and see which direction returns

Causes

  • Connector water or corrosion at the sensor on the intake manifold, thermostat housing or cylinder block
  • Sensor wire chafed on the engine harness
  • Failed sensor element
  • Leaking or blocked boost pressure line to the sensor

Most common here: shorted high (4 of 10)

Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

When to stop

You'll notice: Poor power or black smoke, hard cold starting, slow heater-plug action or a derated engine, with the engine warning on the monitor (user codes E11 or E15 in the SINOCMP table).

Let the engine cool before opening the cooling system; a hot cap releases scalding coolant. Running on with an overheat warning risks a head gasket or seized engine.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.