EF Logo

Komatsu · Engine controller

Komatsu Engine controller internal and network faults fault codes

These codes report the engine controller itself: an internal failure, lost stored data, a lost KOMNET data link to the monitor, or the controller lock warnings. They are different from the sensor codes because the fault is in the controller or its network.

FaultStopCA111Komatsu · Engine controller internal and network faults
Code shows hereFAULTCA111

Where this code shows

Watch the monitor for the user code and the caution lamp or buzzer, and write the code down.

What do these codes mean?

Komatsu codes CA111 to CA1633 are all about the engine controller internal and network faults. 1 needs an immediate stop. Start with this check: check battery voltage and the engine controller supply and ground connections first.

How urgent are they?

1 of 6 codes here means stop now; the other 5 can wait until the shift ends, but find the cause before the next one.

  • Stop now1
  • Check soon5

What should I check first?

Check battery voltage and the engine controller supply and ground connections first

Shared checks

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Komatsu CA111Engine controller critical internal error

    The engine controller detects a critical internal fault in its own hardware.· Part or controller
    Stop now

    Causes

    • Low supply voltage or poor ground to the controller
    • Water or corrosion in the controller connector
    • Failed controller after an electrical event such as jump starting or welding

    Checks

    1. 1Check battery voltage and the controller power and ground wires
    2. 2Inspect the controller connector for water and pushed-back pins
    3. 3Clear the code and restart; note whether it returns immediately
    4. 4Check for other codes that came with it, which may point to the supply cause
    5. 5If it returns with a good supply, have the controller checked or replaced by a dealer
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Komatsu CA757All continuous data lost

    The engine controller lost its stored continuous data.· Other
    Check soon

    Causes

    • Battery disconnected or supply interrupted during a write
    • Controller memory fault
    • Low supply voltage during key off

    Checks

    1. 1Check battery voltage and the battery terminals
    2. 2Clear the code and see whether it returns after a restart
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Komatsu 989L00Engine controller lock warning 1

    The anti-theft or controller lock system reports warning level 1.· Other
    Check soon

    Causes

    • Machine locked or unlock code not accepted
    • Controller or monitor mismatch after replacement

    Checks

    1. 1Use the monitor to enter the correct lock code or ask the owner for it
    2. 2Check that the engine controller and monitor match after any part change
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Komatsu 989M00Engine controller lock warning 2

    The anti-theft or controller lock system reports warning level 2.· Other
    Check soon

    Causes

    • Machine locked or unlock code not accepted
    • Controller or monitor mismatch after replacement

    Checks

    1. 1Use the monitor to enter the correct lock code or ask the owner for it
    2. 2Check that the engine controller and monitor match after any part change
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Komatsu 989N00Engine controller lock warning 3

    The anti-theft or controller lock system reports warning level 3.· Other
    Check soon

    Causes

    • Machine locked or unlock code not accepted
    • Controller or monitor mismatch after replacement

    Checks

    1. 1Use the monitor to enter the correct lock code or ask the owner for it
    2. 2Check that the engine controller and monitor match after any part change
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Komatsu CA1633KOMNET data link timeout

    The engine controller stopped getting messages from the machine network (KOMNET data link) within the allowed time.· Lost message
    Check soon

    Causes

    • Open or shorted data link wire between controllers
    • Connector fault at the pump controller or monitor
    • Another controller off the network because of a supply fault

    Checks

    1. 1Check the KOMNET data link wires and connectors between the controllers
    2. 2Check that the pump controller and monitor have power and ground
    3. 3Look for DA2RMC or E0E at the same time, which shows which controller is missing
    4. 4Measure the resistance across the CAN pair at a controller connector to check termination
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

Shared checks

Checks, in order

  1. 1Check battery voltage and the engine controller supply and ground connections first
  2. 2Inspect the controller connector for water, pushed pins and corrosion
  3. 3Clear the codes, restart and see whether they return at once
  4. 4Check the KOMNET data link wires between engine controller, pump controller and monitor
  5. 5Contact a Komatsu dealer if the controller still reports an internal fault after the supply checks

Causes

  • Low or unstable battery supply to the engine controller
  • Loose controller connector or poor ground
  • Water in the controller connector
  • Controller or monitor fault after a software change

When to stop

You'll notice: Engine will not start or derates, or the monitor loses engine data, with the engine warning and user code E10, E0E or similar (SINOCMP table).

Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.