John Deere · Engine control unit (ECU) - PowerTech engine
John Deere Engine coolant, intake air and fuel temperature fault codes
The engine controller (ECU) watches the coolant level in the surge tank and three temperatures: engine coolant, intake air and fuel. Level sensors give a moderate and a most severe low coolant stage.
More about these partsLess
The cold start aid solenoid circuit, which helps the engine start in the cold, is listed here too. Temperature codes come either as a high or low sensor signal, or as a temperature limit reached, from slightly high up to the most severe level.
Where this code shows
Turn the key on and open the monitor's diagnostic/fault screen.
What do these codes mean?
John Deere codes ECU 000105.00 to ECU 003587.06 are all about the engine coolant, intake air and fuel temperature. The most common failure type is lost message (7 of 20); 3 need an immediate stop. Start with this check: look at the surge tank with the engine cold; if low, find the leak before topping up.
How urgent are they?
3 of 20 codes here mean stop now; the other 17 can wait until the shift ends, but find the cause before the next one.
- Stop now3
- Check soon17
What should I check first?
Look at the surge tank with the engine cold; if low, find the leak before topping up
Shared checks20 of 20
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
John Deere ECU 000105.00Intake air temperature high
The ECU sees intake manifold air temperature above the limit. The operator may see a derate or warning because hot intake air lowers power and raises exhaust temperature.· Shorted highShorted highCheck soonCauses
- Charge air cooler blocked with dust or oil
- Charge air cooler hoses leaking or loose
- Cooling fan not pulling enough air through the cooler
Checks
- 1Check the charge air cooler fins for debris and wash it out
- 2Check the charge air hoses and clamps for leaks
- 3Check the cooling fan runs at full speed and pulls air through the charge air cooler
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
John Deere ECU 000105.04Intake air temperature signal fault
The controller reads the intake air temperature sensor signal below its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Signal wire of the intake air temperature sensor shorted to ground
- Broken or unplugged 5 V supply wire to the intake air temperature sensor
- The intake air temperature sensor failed internally with a stuck low output
Checks
- 1With the intake air temperature sensor unplugged and the key on, check for the 5 V supply on its harness plug; no supply means a broken feed wire or a faulty controller output
- 2Measure the signal wire to ground with both ends disconnected; a very low resistance means a short to ground in the harness
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
John Deere ECU 000105.15Intake air temperature high: cooling system dust
The intake air temperature sensor reading is above its normal range, so the controller reports a high value; this can be a real condition on the machine and not only a wiring fault.· Lost messageLost messageCheck soonCauses
- A real high condition on the machine, such as heat, load or restriction, behind the intake air temperature sensor
- The intake air temperature sensor reading high because of a drifting sensor
- Cooling, intake or supply problem that pushes the value up
Checks
- 1Confirm the real value with an independent gauge or thermometer before blaming the intake air temperature sensor
- 2Look for related codes and for a physical cause such as a blocked cooler or restriction
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
John Deere ECU 000105.16Intake manifold air temperature drastically high
The intake air temperature sensor reading is above its normal range, so the controller reports a high value; this can be a real condition on the machine and not only a wiring fault.· Lost messageLost messageCheck soonCauses
- A real high condition on the machine, such as heat, load or restriction, behind the intake air temperature sensor
- The intake air temperature sensor reading high because of a drifting sensor
- Cooling, intake or supply problem that pushes the value up
Checks
- 1Confirm the real value with an independent gauge or thermometer before blaming the intake air temperature sensor
- 2Look for related codes and for a physical cause such as a blocked cooler or restriction
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
John Deere ECU 000110.00Coolant temperature high
The ECU sees engine coolant temperature above the limit. The operator may see an overheat warning and a derate, and running on can crack the head or blow the gasket.· Shorted highShorted highStop nowCauses
- Coolant level low from a leak
- Radiator or cooler blocked with debris
- Thermostat stuck closed or the water pump failing
- Fan or fan drive not working
Checks
- 1Let the engine idle to cool and check the coolant level when cold
- 2Check the radiator and coolers for blockage on both faces and wash out any packed debris
- 3Check the fan operation and the fan belt or drive
- 4Test the thermostat and check the water pump flow
- 5Check the coolant temperature sensor against an infrared reading
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
John Deere ECU 000110.03Engine coolant temperature signal high
The controller reads the engine coolant temperature sensor signal above its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off.· OtherOtherCheck soonCauses
- Signal wire of the engine coolant temperature sensor shorted to the 5 V supply or to battery voltage
- Open return (ground) wire at the engine coolant temperature sensor, which lets the signal float high
- The engine coolant temperature sensor failed internally with a stuck high output
Checks
- 1Unplug the engine coolant temperature sensor and, key on, measure the harness signal pin: a value near 5 V points to a harness short or a controller fault rather than the part
- 2Check continuity of the engine coolant temperature sensor return wire to the controller sensor ground with both ends disconnected
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere ECU 000110.04Engine coolant temperature low voltage input
The controller reads the engine coolant temperature sensor signal below its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off.· Shorted lowShorted lowCheck soonCauses
- Signal wire of the engine coolant temperature sensor shorted to ground
- Broken or unplugged 5 V supply wire to the engine coolant temperature sensor
- The engine coolant temperature sensor failed internally with a stuck low output
Checks
- 1With the engine coolant temperature sensor unplugged and the key on, check for the 5 V supply on its harness plug; no supply means a broken feed wire or a faulty controller output
- 2Measure the signal wire to ground with both ends disconnected; a very low resistance means a short to ground in the harness
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
John Deere ECU 000110.15Engine coolant temperature slightly high
The engine coolant temperature sensor reading is above its normal range, so the controller reports a high value; this can be a real condition on the machine and not only a wiring fault.· Lost messageLost messageCheck soonCauses
- A real high condition on the machine, such as heat, load or restriction, behind the engine coolant temperature sensor
- The engine coolant temperature sensor reading high because of a drifting sensor
- Cooling, intake or supply problem that pushes the value up
Checks
- 1Confirm the real value with an independent gauge or thermometer before blaming the engine coolant temperature sensor
- 2Look for related codes and for a physical cause such as a blocked cooler or restriction
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
John Deere ECU 000110.16Engine coolant temperature high: cool down
The engine coolant temperature sensor reading is above its normal range, so the controller reports a high value; this can be a real condition on the machine and not only a wiring fault.· Lost messageLost messageCheck soonCauses
- A real high condition on the machine, such as heat, load or restriction, behind the engine coolant temperature sensor
- The engine coolant temperature sensor reading high because of a drifting sensor
- Cooling, intake or supply problem that pushes the value up
Checks
- 1Confirm the real value with an independent gauge or thermometer before blaming the engine coolant temperature sensor
- 2Look for related codes and for a physical cause such as a blocked cooler or restriction
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
John Deere ECU 000110.17Engine coolant temperature low: warm up
The engine coolant temperature sensor reading is below its normal range, so the controller reports a low value; this can be a real condition on the machine and not only a wiring fault.· Lost messageLost messageCheck soonCauses
- A real low condition on the machine, such as low level, low pressure or a cold engine, behind the engine coolant temperature sensor
- The engine coolant temperature sensor reading low because of a drifting sensor
- Supply or feed problem that holds the value down
Checks
- 1Confirm the real value with an independent gauge or by inspection before blaming the engine coolant temperature sensor
- 2Look for related codes and for a physical cause such as a low level, leak or weak supply
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
John Deere ECU 000111.01Coolant level low
The coolant level sensor shows the coolant level is low. The operator may see a low coolant warning, and running on risks overheating and engine damage.· Real conditionReal conditionStop nowCauses
- Coolant level really low from a leak or an overdue top-up
- Radiator or surge tank cap not sealing and letting coolant out
- Coolant level sensor faulty or coated with deposits
- Level sensor wiring damaged
Checks
- 1With the engine cold, check the coolant level in the surge tank and top it up with the correct coolant
- 2Look for coolant leaks at hoses, the radiator, the water pump and the head gasket area
- 3Check the surge tank cap seal and pressure rating
- 4Check the level sensor connector and wiring for damage
- 5Clean the sensor tip and recheck once the level is right
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
John Deere ECU 000111.07Coolant loss detected
The surge tank sensors indicate that coolant is being lost over time. The operator may see a coolant warning that returns after topping up, and white exhaust smoke or overheating may follow.· Real conditionReal conditionStop nowCauses
- External coolant leak at a hose, radiator or water pump seal
- Internal leak such as a failing cylinder head gasket pushing coolant out
- Cooling system overpressure blowing coolant out through the cap
Checks
- 1Pressure test the cooling system cold and look for drips or wet marks
- 2Check the engine oil for a milky colour that would point to an internal leak
- 3Look at the surge tank when running for bubbles that suggest combustion gas in the coolant
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
John Deere ECU 000111.17Coolant level low (moderate)
The coolant level sensor reads moderately low. The operator may see a coolant level warning but the engine may still run normally, so the cause should be found before it gets worse.· OtherOtherCheck soonCauses
- Slow coolant loss from a small leak or seeping connection
- Coolant not topped up to the correct level at service
- Surge tank sensor reading marginal because of deposits
Checks
- 1Check the coolant level cold and compare it with the markings on the surge tank
- 2Look around hose clamps and the pump for dried coolant crust
- 3Top up and see how long it takes for the warning to come back
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere ECU 000111.18Coolant level low: moderately severe level
The surge tank coolant level reads low at the moderately severe level, so the engine is warning the operator to top up before it becomes severe.· OtherOtherCheck soonCauses
- A real low condition on the machine, such as low level, low pressure or a cold engine, behind the engine coolant level sensor
- The engine coolant level sensor reading low because of a drifting sensor
- Supply or feed problem that holds the value down
Checks
- 1Confirm the real value with an independent gauge or by inspection before blaming the engine coolant level sensor
- 2Look for related codes and for a physical cause such as a low level, leak or weak supply
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere ECU 000174.00Fuel temperature high
The ECU sees fuel temperature above the limit. The operator may see a derate or warning because hot fuel lowers lubrication and power.· Shorted highShorted highCheck soonCauses
- Fuel return flow heating the tank too much
- Fuel cooler blocked
- Hot ambient or heavy work with a low tank
Checks
- 1Check the fuel level in the tank and the fuel return line
- 2Check the fuel cooler, if fitted, for blockage and airflow through its fins
- 3Compare the fuel temperature reading with an infrared measurement
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
John Deere ECU 000174.03Fuel temperature sensor inaccessible
The controller reads the fuel temperature sensor signal above its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off.· OtherOtherCheck soonCauses
- Signal wire of the fuel temperature sensor shorted to the 5 V supply or to battery voltage
- Open return (ground) wire at the fuel temperature sensor, which lets the signal float high
- The fuel temperature sensor failed internally with a stuck high output
Checks
- 1Unplug the fuel temperature sensor and, key on, measure the harness signal pin: a value near 5 V points to a harness short or a controller fault rather than the part
- 2Check continuity of the fuel temperature sensor return wire to the controller sensor ground with both ends disconnected
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere ECU 000174.04Fuel temperature signal voltage low
The controller reads the fuel temperature sensor signal below its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off.· Shorted lowShorted lowCheck soonCauses
- Signal wire of the fuel temperature sensor shorted to ground
- Broken or unplugged 5 V supply wire to the fuel temperature sensor
- The fuel temperature sensor failed internally with a stuck low output
Checks
- 1With the fuel temperature sensor unplugged and the key on, check for the 5 V supply on its harness plug; no supply means a broken feed wire or a faulty controller output
- 2Measure the signal wire to ground with both ends disconnected; a very low resistance means a short to ground in the harness
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
John Deere ECU 000174.16Fuel temperature increased
The fuel temperature sensor reading is above its normal range, so the controller reports a high value; this can be a real condition on the machine and not only a wiring fault.· Lost messageLost messageCheck soonCauses
- A real high condition on the machine, such as heat, load or restriction, behind the fuel temperature sensor
- The fuel temperature sensor reading high because of a drifting sensor
- Cooling, intake or supply problem that pushes the value up
Checks
- 1Confirm the real value with an independent gauge or thermometer before blaming the fuel temperature sensor
- 2Look for related codes and for a physical cause such as a blocked cooler or restriction
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
John Deere ECU 003587.05Cold start aid solenoid open circuit
The ECU sees an open circuit in the cold start aid circuit. Cold starts may be hard and the engine may smoke white until it warms up in low temperatures.· Open circuitOpen circuitCheck soonCauses
- Cold start aid element or solenoid coil burnt out and open
- Broken wire or loose connector in the start aid feed
- Blown fuse or failed relay in the circuit
Checks
- 1Check the cold start aid fuse and relay; an open circuit often starts with a blown fuse or a relay that no longer clicks
- 2Measure the resistance of the heater element or solenoid coil with the plug off
- 3Check the wiring continuity from the ECU output to the device
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
John Deere ECU 003587.06Cold start aid solenoid short circuit
The ECU sees a short circuit in the cold start aid circuit. Cold starts may be hard, and the short can blow a fuse or damage the ECU output.· Lost messageLost messageCheck soonCauses
- Heater element or solenoid coil shorted internally
- Start aid feed wire shorted to ground
- Water in the start aid connector
Checks
- 1Check the cold start aid fuse for a blown element
- 2Measure the element or coil resistance and compare it with a good one
- 3Check the feed wiring for a short to ground with the ECU unplugged
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Shared checks
Checks, in order
- 1Look at the surge tank with the engine cold; if low, find the leak before topping up
- 2Compare the monitor temperature with a temperature gun on the thermostat housing, intake pipe or fuel line to tell a real fault from a false signal
- 3Unplug the sensor and check the harness for reference voltage; measure its resistance against the manual table
- 4Clean the coolers, check the fan runs at full speed and check for white smoke or oil in coolant
- 5Watch a warm-up from cold; the reading should rise smoothly, not jump
Causes
- Coolant really low from a leak at a hose, radiator, water pump or head gasket
- Cooler or charge air cooler blocked with dust, so the engine or intake air really runs hot
- Temperature or level sensor failed, scaled, or its plug corroded
- Wire open or shorted to ground, giving a false very cold or very hot reading
Most common here: lost message (7 of 20)
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
When to stop
You'll notice: A warning appears, the gauge may read wrongly, and the engine may derate or shut down at the most severe stage to protect itself.
Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
- Excavator Fault Codes - John Deere excavators fault codes list (MCZ/ECU/DSZ)
- Inside the Yard - John Deere fault codes list (ECU engine codes)
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.