JCB · Aftertreatment ECU - SCR / DEF
JCB NOx sensors fault codes
The upstream and downstream NOx sensors measure NOx before and after the SCR catalyst. They are heated sensors with their own controllers.
Where this code shows
Switch the key on and note any warning lamp or fault icon on the cluster.
What do these codes mean?
JCB codes P2A00-00 to P2209-02 are all about the nOx sensors. The most common failure type is lost message (8 of 30); none needs an immediate stop. Start with this check: inspect the NOx sensor connector for water, corrosion and pushed-back pins.
How urgent are they?
None of the 30 codes here means stop now; all 30 can wait until the shift ends, but find the cause before the next one.
- Check soon30
What should I check first?
Inspect the NOx sensor connector for water, corrosion and pushed-back pins
Shared checks30 of 30
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
JCB P2A00-00Upstream NOx sensor missing or loose
The upstream NOx sensor is missing or loose, meaning the controller thinks the sensor is not fitted or not seated, so there is no engine-out NOx figure. This sensor sits ahead of the SCR catalyst and reports the NOx leaving the engine, which the controller uses to set the DEF dose. The tool reports no sensor at all, as if it had been unplugged.· OtherOtherCheck soonCauses
- Sensor not fitted or not seated
- Connector unplugged
- Retaining nut on the sensor boss not tightened after service
Checks
- 1Check that the sensor is fitted and its plug is pushed home
- 2Inspect the sensor mount for damage
- 3Check the ground strap between the sensor control unit and the chassis
- 4Check that the sensor is fully tightened in its boss and the plug is clipped to its bracket, noting that this is the sensor ahead of the catalyst
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P2A01-00Downstream NOx sensor missing or loose
The downstream NOx sensor is missing or loose, meaning the controller thinks the sensor is not fitted or not seated, so there is no tailpipe NOx figure. This sensor sits after the SCR catalyst and shows how much NOx got through, which is how the controller judges conversion. The tool reports no sensor at all, as if it had been unplugged.· OtherOtherCheck soonCauses
- Sensor not fitted or not seated
- Connector unplugged
- Retaining nut on the sensor boss not tightened after service
Checks
- 1Check that the sensor is fitted and its plug is pushed home
- 2Inspect the sensor mount for damage
- 3Look for engine oil or DEF crystals on the sensor body that would show a leak upstream
- 4Check that the sensor is fully tightened in its boss and the plug is clipped to its bracket, noting that this is the sensor after the catalyst
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P2200-00Upstream NOx sensor voltage supply diagnosis error
The upstream NOx sensor had its supply voltage diagnosis fail: the sensor control unit reports the heater or sensor feed is wrong, so the engine-out NOx figure cannot be trusted. This sensor sits ahead of the SCR catalyst and reports the NOx leaving the engine, which the controller uses to set the DEF dose. On the machine this shows up as a SCR warning lamp soon after start, because a sensor without proper supply never leaves its start-up state.· OtherOtherCheck soonCauses
- Low or unstable supply to the sensor control unit
- Corroded supply or earth pin at the sensor plug
- Battery or charging problem dipping the voltage
- Blown fuse or tripped protection feeding the NOx sensor control unit
Checks
- 1Measure the supply and earth at the sensor plug with the key on and compare with battery voltage
- 2Check the NOx sensor fuse and relay
- 3Check the battery and charging voltage while the engine runs
- 4Check the sensor heater feed fuse and the relay that powers it with the key on
- 5Trace the sensor feed back to its fuse and relay and measure voltage drop under the sensor's heater load, noting that this is the sensor ahead of the catalyst
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P2200-02Upstream NOx sensor short circuit
The upstream NOx sensor reported a short circuit in the sensor or its wiring, so the controller shuts the sensor down and the dose may be set from a model instead. This sensor sits ahead of the SCR catalyst and reports the NOx leaving the engine, which the controller uses to set the DEF dose. The sensor is shut down at once, so the lamp comes on quickly and no NOx value is shown on the tool.· Short circuitShort circuitCheck soonCauses
- Sensor wire chafed against the exhaust or a bracket
- Sensor control unit failed internally
- Sensor lead melted where it lies against the exhaust pipe or turbo heat shield
Checks
- 1Inspect the sensor lead along its whole length for burnt or chafed insulation
- 2Unplug the sensor and check the wiring for a short to ground or supply
- 3Look for exhaust soot or water ingress at the sensor plug seal
- 4Run a thumb along the lead looking for hardened, cracked or discoloured insulation and measure insulation resistance to ground, noting that this is the sensor ahead of the catalyst
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.
Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.
JCB P2200-05Upstream NOx sensor self diagnostic
The upstream NOx sensor ran its self diagnostic and reported a fault, which means the sensor itself found a problem with its own cell or electronics. This sensor sits ahead of the SCR catalyst and reports the NOx leaving the engine, which the controller uses to set the DEF dose. The fault is usually stored at key-on after the sensor finishes its own check, not while working.· OtherOtherCheck soonCauses
- Sensor cell aged or contaminated
- Sensor control unit fault
- Water condensing inside a cold sensor cell during repeated short runs
Checks
- 1Read the sensor's own diagnostic status in the aftertreatment tool
- 2Replace the sensor only after the supply and wiring are proven good
- 3Inspect the sensor boss thread in the pipe for a leaking exhaust joint
- 4Run the machine to full exhaust temperature for ten minutes and see whether the status returns, noting that this is the sensor ahead of the catalyst
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P2200-11Lambda signal below minimum for upstream NOx sensor
The upstream NOx sensor sent a lambda or oxygen signal below its minimum, so the exhaust looks richer than the sensor can accept; the NOx value that goes with it is rejected. This sensor sits ahead of the SCR catalyst and reports the NOx leaving the engine, which the controller uses to set the DEF dose. The tool will show an oxygen figure stuck at one end of its scale next to a usable temperature.· Lost messageLost messageCheck soonCauses
- Sensor oxygen cell failed or contaminated
- Genuinely rich exhaust from an engine fault
- Oil or coolant smoke burning in the exhaust and coating the oxygen cell
Checks
- 1Read the lambda value and compare it with the engine air-fuel data
- 2Look for engine faults that could cause rich running
- 3Compare the sensor temperature reading with the exhaust temperature after warm-up
- 4Check for blue or white smoke, coolant loss and oil consumption that could foul the cell, noting that this is the sensor ahead of the catalyst
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB P2200-12Lambda signal above maximum for upstream NOx sensor
The upstream NOx sensor sent a lambda or oxygen signal above its maximum, so the exhaust looks leaner than the sensor can accept; the NOx value that goes with it is rejected. This sensor sits ahead of the SCR catalyst and reports the NOx leaving the engine, which the controller uses to set the DEF dose. The tool will show an oxygen figure stuck at the lean end while the engine runs normally.· Lost messageLost messageCheck soonCauses
- Sensor oxygen cell failed or leaking
- Exhaust leak ahead of the sensor letting in air
- Cracked exhaust manifold or loose clamp allowing outside air to reach the sensor
Checks
- 1Check for exhaust leaks upstream of the sensor
- 2Read the lambda value on live data when the engine is at idle
- 3Check the ground strap between the sensor control unit and the chassis
- 4Spray soapy water on exhaust joints ahead of the sensor with the engine running and look for bubbling, noting that this is the sensor ahead of the catalyst
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB P2200-13Upstream NOx sensor open circuit
The upstream NOx sensor reported an open circuit, so there is no connection between the sensor element and its control unit and the engine-out NOx figure is lost. This sensor sits ahead of the SCR catalyst and reports the NOx leaving the engine, which the controller uses to set the DEF dose. The NOx value drops out or reads a fixed default and the SCR warning appears.· Open circuitOpen circuitCheck soonCauses
- Sensor lead broken or pulled out of its connector
- Sensor connector pin corroded or pushed back
- Heater-and-signal connector pushed back by a previous removal so one pin never makes contact
Checks
- 1Check continuity of the sensor harness from the plug to the control unit
- 2Inspect the sensor plug for bent or pushed-back pins
- 3Look for engine oil or DEF crystals on the sensor body that would show a leak upstream
- 4Back-probe each pin of the sensor plug and compare continuity with the pin-out drawing, noting that this is the sensor ahead of the catalyst
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
JCB P2200-61Invalid signal from upstream NOx sensor after heater release
The upstream NOx sensor returned an invalid signal after the heater was released, meaning the sensor warmed up but did not give a usable NOx reading. This sensor sits ahead of the SCR catalyst and reports the NOx leaving the engine, which the controller uses to set the DEF dose. The sensor warms up, then the NOx figure stays flat or erratic and the SCR check fails after start.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Sensor element contaminated or aged
- Wet or sooty sensor tip
- Sensor fitted after a wash-down while still wet inside the ceramic
Checks
- 1Let the engine run to full temperature and read the NOx value again
- 2Inspect the sensor tip for water, soot or damage
- 3Read the sensor status bits in the aftertreatment tool and note which one is set
- 4Allow a long warm run, then repeat the key-on test and look at how fast the NOx value settles, noting that this is the sensor ahead of the catalyst
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
JCB P2200-63Upstream NOx sensor self diagnostic timeout
The upstream NOx sensor did not finish its self diagnostic within the allowed time, so the controller cannot tell whether the sensor works. This sensor sits ahead of the SCR catalyst and reports the NOx leaving the engine, which the controller uses to set the DEF dose. The test starts but never reports a result, so the warning may appear after a cold start.· Lost messageLost messageCheck soonCauses
- Slow or interrupted sensor warm-up
- Intermittent sensor connection
- Low ambient temperature slowing the self-test beyond its time limit
Checks
- 1Check the sensor connector for loose contact
- 2Repeat the key-on test after the sensor has had time to warm
- 3Wiggle the sensor lead along its clips while watching the NOx value for dropouts
- 4Repeat the test after the machine has been warmed in a shed or by idling for a while, noting that this is the sensor ahead of the catalyst
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB P2200-94Upstream NOx sensor self diagnostic abort
The upstream NOx sensor aborted its self diagnostic part-way through, so the result is unknown and the controller sets a fault. This sensor sits ahead of the SCR catalyst and reports the NOx leaving the engine, which the controller uses to set the DEF dose. The test was cut short, so this often disappears after a clean restart if the supply is steady.· OtherOtherCheck soonCauses
- Key or supply interrupted during the test
- Sensor control unit reset
- Operator turning the key off before the post-run test finished
Checks
- 1Check battery voltage and the power supply during key-off and key-on
- 2Repeat the test with a stable supply
- 3Check the sensor control unit plug for bent terminals and sealing gland damage
- 4Wait for the controller to finish its shutdown routine before cutting the master switch, noting that this is the sensor ahead of the catalyst
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P2201-00Downstream NOx sensor supply voltage diagnosis error
The downstream NOx sensor had its supply voltage diagnosis fail: the sensor control unit reports the heater or sensor feed is wrong, so the tailpipe NOx figure cannot be trusted. This sensor sits after the SCR catalyst and shows how much NOx got through, which is how the controller judges conversion. On the machine this shows up as a SCR warning lamp soon after start, because a sensor without proper supply never leaves its start-up state.· OtherOtherCheck soonCauses
- Low or unstable supply to the sensor control unit
- Corroded supply or earth pin at the sensor plug
- Battery or charging problem dipping the voltage
- Blown fuse or tripped protection feeding the NOx sensor control unit
Checks
- 1Measure the supply and earth at the sensor plug with the key on and compare with battery voltage
- 2Check the NOx sensor fuse and relay
- 3Check the battery and charging voltage while the engine runs
- 4Check that the plugs of the upstream and downstream sensors have not been swapped after service
- 5Trace the sensor feed back to its fuse and relay and measure voltage drop under the sensor's heater load, noting that this is the sensor after the catalyst
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P2201-1CDownstream NOx sensor short circuit
The downstream NOx sensor reported a short circuit in the sensor or its wiring, so the controller shuts the sensor down and the controller cannot confirm that the catalyst is working. This sensor sits after the SCR catalyst and shows how much NOx got through, which is how the controller judges conversion. The sensor is shut down at once, so the lamp comes on quickly and no NOx value is shown on the tool.· Short circuitShort circuitCheck soonCauses
- Sensor wire chafed against the exhaust or a bracket
- Sensor control unit failed internally
- Sensor lead melted where it lies against the exhaust pipe or turbo heat shield
Checks
- 1Inspect the sensor lead along its whole length for burnt or chafed insulation
- 2Unplug the sensor and check the wiring for a short to ground or supply
- 3Check the ground strap between the sensor control unit and the chassis
- 4Run a thumb along the lead looking for hardened, cracked or discoloured insulation and measure insulation resistance to ground, noting that this is the sensor after the catalyst
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.
Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.
JCB P2201-06Downstream NOx sensor self diagnostic
The downstream NOx sensor ran its self diagnostic and reported a fault, which means the sensor itself found a problem with its own cell or electronics. This sensor sits after the SCR catalyst and shows how much NOx got through, which is how the controller judges conversion. The fault is usually stored at key-on after the sensor finishes its own check, not while working.· OtherOtherCheck soonCauses
- Sensor cell aged or contaminated
- Sensor control unit fault
- Water condensing inside a cold sensor cell during repeated short runs
Checks
- 1Read the sensor's own diagnostic status in the aftertreatment tool
- 2Replace the sensor only after the supply and wiring are proven good
- 3Inspect the lead for heat damage where it passes the exhaust heat shield
- 4Run the machine to full exhaust temperature for ten minutes and see whether the status returns, noting that this is the sensor after the catalyst
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P2201-11Lambda signal below minimum for downstream NOx sensor
The downstream NOx sensor sent a lambda or oxygen signal below its minimum, so the exhaust looks richer than the sensor can accept; the NOx value that goes with it is rejected. This sensor sits after the SCR catalyst and shows how much NOx got through, which is how the controller judges conversion. The tool will show an oxygen figure stuck at one end of its scale next to a usable temperature.· Lost messageLost messageCheck soonCauses
- Sensor oxygen cell failed or contaminated
- Genuinely rich exhaust from an engine fault
- Oil or coolant smoke burning in the exhaust and coating the oxygen cell
Checks
- 1Read the lambda value and compare it with the engine air-fuel data
- 2Look for engine faults that could cause rich running
- 3Measure the sensor supply while the engine is cranking to see whether it collapses
- 4Check for blue or white smoke, coolant loss and oil consumption that could foul the cell, noting that this is the sensor after the catalyst
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB P2201-12Lambda signal above maximum for downstream NOx sensor
The downstream NOx sensor sent a lambda or oxygen signal above its maximum, so the exhaust looks leaner than the sensor can accept; the NOx value that goes with it is rejected. This sensor sits after the SCR catalyst and shows how much NOx got through, which is how the controller judges conversion. The tool will show an oxygen figure stuck at the lean end while the engine runs normally.· Lost messageLost messageCheck soonCauses
- Sensor oxygen cell failed or leaking
- Exhaust leak ahead of the sensor letting in air
- Cracked exhaust manifold or loose clamp allowing outside air to reach the sensor
Checks
- 1Check for exhaust leaks upstream of the sensor
- 2Read the lambda value on live data when the engine is at idle
- 3Check the sensor heater feed fuse and the relay that powers it with the key on
- 4Spray soapy water on exhaust joints ahead of the sensor with the engine running and look for bubbling, noting that this is the sensor after the catalyst
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB P2201-13Downstream NOx sensor open circuit
The downstream NOx sensor reported an open circuit, so there is no connection between the sensor element and its control unit and the tailpipe NOx figure is lost. This sensor sits after the SCR catalyst and shows how much NOx got through, which is how the controller judges conversion. The NOx value drops out or reads a fixed default and the SCR warning appears.· Open circuitOpen circuitCheck soonCauses
- Sensor lead broken or pulled out of its connector
- Sensor connector pin corroded or pushed back
- Heater-and-signal connector pushed back by a previous removal so one pin never makes contact
Checks
- 1Check continuity of the sensor harness from the plug to the control unit
- 2Inspect the sensor plug for bent or pushed-back pins
- 3Look for exhaust soot or water ingress at the sensor plug seal
- 4Back-probe each pin of the sensor plug and compare continuity with the pin-out drawing, noting that this is the sensor after the catalyst
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
JCB P2201-16Downstream NOx offset minimum error detection
The downstream NOx sensor shows an offset below its minimum when the controller checks the zero value, so the tailpipe NOx figure reads lower than it should. This sensor sits after the SCR catalyst and shows how much NOx got through, which is how the controller judges conversion. The NOx figure reads a little low even with the engine off, a drift you cannot see in normal work.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Sensor drift from age
- Contaminated sensor
- Sensor zero point shifted by long service life
Checks
- 1Compare the sensor zero reading with the other sensor at engine off
- 2Replace the sensor if the offset stays after a clean connector check
- 3Check that the upstream sensor has no fault, because the downstream reading is judged against it
- 4Inspect the sensor boss thread in the pipe for a leaking exhaust joint
- 5Compare the zero value on this sensor after engine off with a new sensor reading the same pipe, if one is available, noting that this is the sensor after the catalyst
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
JCB P2201-17Downstream NOx offset maximum error detection
The downstream NOx sensor shows an offset above its maximum when the controller checks the zero value, so the tailpipe NOx figure reads higher than it should. This sensor sits after the SCR catalyst and shows how much NOx got through, which is how the controller judges conversion. The NOx figure reads a little high even with the engine off, a drift you cannot see in normal work.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Sensor drift from age
- Contaminated sensor
- Sensor zero point shifted by contamination with soot or oil
Checks
- 1Compare the sensor zero reading with the other sensor at engine off
- 2Replace the sensor if the offset stays after a clean connector check
- 3Check that the upstream sensor has no fault, because the downstream reading is judged against it
- 4Compare the sensor temperature reading with the exhaust temperature after warm-up
- 5Compare the zero value with a clean reference and inspect the sensor tip for a black coating, noting that this is the sensor after the catalyst
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
JCB P2201-61Invalid signal from downstream NOx sensor after heater release
The downstream NOx sensor returned an invalid signal after the heater was released, meaning the sensor warmed up but did not give a usable NOx reading. This sensor sits after the SCR catalyst and shows how much NOx got through, which is how the controller judges conversion. The sensor warms up, then the NOx figure stays flat or erratic and the SCR check fails after start.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Sensor element contaminated or aged
- Wet or sooty sensor tip
- Sensor fitted after a wash-down while still wet inside the ceramic
Checks
- 1Let the engine run to full temperature and read the NOx value again
- 2Inspect the sensor tip for water, soot or damage
- 3Check that the upstream sensor has no fault, because the downstream reading is judged against it
- 4Look for engine oil or DEF crystals on the sensor body that would show a leak upstream
- 5Allow a long warm run, then repeat the key-on test and look at how fast the NOx value settles, noting that this is the sensor after the catalyst
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
JCB P2201-63Downstream NOx sensor self diagnostic timeout
The downstream NOx sensor did not finish its self diagnostic within the allowed time, so the controller cannot tell whether the sensor works. This sensor sits after the SCR catalyst and shows how much NOx got through, which is how the controller judges conversion. The test starts but never reports a result, so the warning may appear after a cold start.· Lost messageLost messageCheck soonCauses
- Slow or interrupted sensor warm-up
- Intermittent sensor connection
- Low ambient temperature slowing the self-test beyond its time limit
Checks
- 1Check the sensor connector for loose contact
- 2Repeat the key-on test after the sensor has had time to warm
- 3Read the sensor status bits in the aftertreatment tool and note which one is set
- 4Repeat the test after the machine has been warmed in a shed or by idling for a while, noting that this is the sensor after the catalyst
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB P2201-97Downstream NOx sensor self diagnostic abort
The downstream NOx sensor aborted its self diagnostic part-way through, so the result is unknown and the controller sets a fault. This sensor sits after the SCR catalyst and shows how much NOx got through, which is how the controller judges conversion. The test was cut short, so this often disappears after a clean restart if the supply is steady.· OtherOtherCheck soonCauses
- Key or supply interrupted during the test
- Sensor control unit reset
- Operator turning the key off before the post-run test finished
Checks
- 1Check battery voltage and the power supply during key-off and key-on
- 2Repeat the test with a stable supply
- 3Wiggle the sensor lead along its clips while watching the NOx value for dropouts
- 4Wait for the controller to finish its shutdown routine before cutting the master switch, noting that this is the sensor after the catalyst
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P2202-00Upstream NOx sensor reading below minimum threshold
The upstream NOx sensor is reading below the minimum threshold the controller accepts, so the engine-out NOx figure is rejected as too low. This sensor sits ahead of the SCR catalyst and reports the NOx leaving the engine, which the controller uses to set the DEF dose. The tool shows NOx stuck near zero even under load, which cannot be correct.· Real conditionReal conditionCheck soonCauses
- Failed or drifted sensor reading low
- Sensor shorted internally
- Heavily fouled or cracked sensing element
Checks
- 1Compare the value with the other NOx sensor and the engine's modelled NOx
- 2Unplug and inspect the sensor
- 3Compare this reading with the downstream sensor before replacing the upstream one
- 4Check the sensor control unit plug for bent terminals and sealing gland damage
- 5Compare the NOx readings with the engine load on a road test, where NOx should rise with load, noting that this is the sensor ahead of the catalyst
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
JCB P2202-16Downstream NOx sensor reading below minimum threshold
The downstream NOx sensor is reading below the minimum threshold the controller accepts, so the tailpipe NOx figure is rejected as too low. This sensor sits after the SCR catalyst and shows how much NOx got through, which is how the controller judges conversion. The tool shows NOx stuck near zero even under load, which cannot be correct.· Real conditionReal conditionCheck soonCauses
- Failed or drifted sensor reading low
- Sensor shorted internally
- Heavily fouled or cracked sensing element
Checks
- 1Compare the value with the other NOx sensor and the engine's modelled NOx
- 2Unplug and inspect the sensor
- 3Check that the upstream sensor has no fault, because the downstream reading is judged against it
- 4Check that the plugs of the upstream and downstream sensors have not been swapped after service
- 5Compare the NOx readings with the engine load on a road test, where NOx should rise with load, noting that this is the sensor after the catalyst
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
JCB P2203-00Upstream NOx sensor reading exceeds maximum threshold
The upstream NOx sensor is reading above the maximum threshold the controller accepts, so the engine-out NOx figure is rejected as too high. This sensor sits ahead of the SCR catalyst and reports the NOx leaving the engine, which the controller uses to set the DEF dose. The tool shows NOx stuck near the top of its range even at idle, which cannot be correct.· Real conditionReal conditionCheck soonCauses
- Failed or drifted sensor reading high
- Real high NOx from an engine or EGR fault
- Failing EGR flow letting engine-out NOx climb
Checks
- 1Compare the value with the other NOx sensor and the engine's modelled NOx
- 2Check the EGR and the engine for faults that raise NOx
- 3Compare this reading with the downstream sensor before replacing the upstream one
- 4Inspect the lead for heat damage where it passes the exhaust heat shield
- 5Check EGR valve motion and cooler condition to rule out a real NOx rise, noting that this is the sensor ahead of the catalyst
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
JCB P2203-17Downstream NOx sensor reading exceeds maximum threshold
The downstream NOx sensor is reading above the maximum threshold the controller accepts, so the tailpipe NOx figure is rejected as too high. This sensor sits after the SCR catalyst and shows how much NOx got through, which is how the controller judges conversion. The tool shows NOx stuck near the top of its range even at idle, which cannot be correct.· Real conditionReal conditionCheck soonCauses
- Failed or drifted sensor reading high
- Real high NOx from an engine or EGR fault
- Failing EGR flow letting engine-out NOx climb
Checks
- 1Compare the value with the other NOx sensor and the engine's modelled NOx
- 2Check the EGR and the engine for faults that raise NOx
- 3Check that the upstream sensor has no fault, because the downstream reading is judged against it
- 4Measure the sensor supply while the engine is cranking to see whether it collapses
- 5Check EGR valve motion and cooler condition to rule out a real NOx rise, noting that this is the sensor after the catalyst
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
JCB P2208-00Downstream NOx sensor heater not available
The downstream NOx sensor cannot get its heater to work, so the sensor stays cold and cannot measure NOx. This sensor sits after the SCR catalyst and shows how much NOx got through, which is how the controller judges conversion. The sensor never warms, so SCR dosing may be disabled until it is repaired.· OtherOtherCheck soonCauses
- Heater element open inside the sensor
- Heater supply missing at the sensor plug
- Heater circuit open inside the sensor cap
Checks
- 1Measure the heater supply at the plug
- 2Check the sensor heater feed fuse
- 3Check the sensor heater feed fuse and the relay that powers it with the key on
- 4Measure heater resistance at the sensor pins and compare with the manual figure, noting that this is the sensor after the catalyst
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P2208-02Downstream NOx sensor heater not heating quickly enough
The downstream NOx sensor heats up too slowly, so the controller waits too long before it can use the sensor and logs a fault. This sensor sits after the SCR catalyst and shows how much NOx got through, which is how the controller judges conversion. The sensor takes too long to warm, so dosing starts late after a cold start.· Lost messageLost messageCheck soonCauses
- Weak heater element
- High resistance in the heater supply
- Voltage drop in the heater feed under heavy current
Checks
- 1Check the supply voltage at the sensor during warm-up
- 2Look for corrosion in the sensor supply connector
- 3Look for exhaust soot or water ingress at the sensor plug seal
- 4Measure heater supply voltage while the heater is on and compare it with battery voltage, noting that this is the sensor after the catalyst
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB P2209-00Upstream NOx sensor heater not available
The upstream NOx sensor cannot get its heater to work, so the sensor stays cold and cannot measure NOx. This sensor sits ahead of the SCR catalyst and reports the NOx leaving the engine, which the controller uses to set the DEF dose. The sensor never warms, so SCR dosing may be disabled until it is repaired.· OtherOtherCheck soonCauses
- Heater element open inside the sensor
- Heater supply missing at the sensor plug
- Heater circuit open inside the sensor cap
Checks
- 1Measure the heater supply at the plug
- 2Check the sensor heater feed fuse
- 3Inspect the sensor boss thread in the pipe for a leaking exhaust joint
- 4Measure heater resistance at the sensor pins and compare with the manual figure, noting that this is the sensor ahead of the catalyst
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P2209-02Upstream NOx sensor heater not heating quickly enough
The upstream NOx sensor heats up too slowly, so the controller waits too long before it can use the sensor and logs a fault. This sensor sits ahead of the SCR catalyst and reports the NOx leaving the engine, which the controller uses to set the DEF dose. The sensor takes too long to warm, so dosing starts late after a cold start.· Lost messageLost messageCheck soonCauses
- Weak heater element
- High resistance in the heater supply
- Voltage drop in the heater feed under heavy current
Checks
- 1Check the supply voltage at the sensor during warm-up
- 2Look for corrosion in the sensor supply connector
- 3Compare the sensor temperature reading with the exhaust temperature after warm-up
- 4Measure heater supply voltage while the heater is on and compare it with battery voltage, noting that this is the sensor ahead of the catalyst
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Shared checks
Checks, in order
- 1Inspect the NOx sensor connector for water, corrosion and pushed-back pins
- 2Check the wiring to the NOx sensor for opens, shorts to ground or battery, and chafing
- 3Check the sensor heater (on the NOx sensor, with the diagnostic tool and a multimeter)
- 4Check the sensor is fitted tight and not loose or missing at its mount
Causes
- Sensor failed
- Wiring fault
- Heater fault
- Sensor loose or missing
Most common here: lost message (8 of 30)
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
When to stop
You'll notice: An SCR warning may show.
Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
- Partao JCB fault code list, page 12 (code table)
- Partao JCB fault code list, page 14 (code table)
- Partao JCB fault code list, page 13 (code table)
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.
