JCB Inducement for dosing, quality and consumption fault codes

These codes record the inducement step the engine is in because of an SCR or DEF dosing, quality or consumption problem.

FaultInfoP2BAA-00JCB · Inducement for dosing, quality and consumption
Code shows hereFAULTP2BAA-00

Where this code shows

Switch the key on and note any warning lamp or fault icon on the cluster.

What do these codes mean?

JCB codes P2BAA-00 to P2BAA-94 are all about the inducement for dosing, quality and consumption. None needs an immediate stop. Start with this check: find and fix the underlying SCR or DEF fault that caused this inducement step.

How urgent are they?

None of the 20 codes here means stop now; 17 can wait until the shift ends, but find the cause before the next one; 3 are information only.

  • Check soon17
  • Info3

What should I check first?

Find and fix the underlying SCR or DEF fault that caused this inducement step

Shared checks

20 of 20

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • JCB P2BAA-00Consumption warning requested

    A warning has been requested for excess DEF consumption or low reagent.· Other
    Info

    Causes

    • Low DEF level
    • Dosing valve stuck or lines leaking
    • DEF level sensor reading wrongly and hiding a leak
    • Warning raised long before the engine is limited
    • Consumption monitor reading wrong because the level sender is faulty

    Checks

    1. 1Check the tank level, then compare the measured DEF use against the commanded dose
    2. 2Look for a leak in the DEF lines, a blocked nozzle or a dosing valve that is stuck
    3. 3Repair the cause while only a warning is shown and clear the code after the repair
    4. 4Inspect the DEF dosing nozzle in the exhaust for crystal build-up
    5. 5Compare the DEF added at the last refill with the engine hours since, to see how fast it is being used.
    6. 6Log tank level, dosing demand and elapsed hours across one full shift to see the actual burn rate against the expected one
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB P2BAA-F0Consumption level 2 requested

    Inducement level 2 has been requested for excess DEF consumption or low reagent.· Other
    Check soon

    Causes

    • Low DEF level
    • Dosing valve stuck or lines leaking
    • DEF level sensor reading wrongly and hiding a leak
    • Countdown to the second limit has started
    • Consumption monitor reading wrong because the level sender is faulty

    Checks

    1. 1Check the tank level, then compare the measured DEF use against the commanded dose
    2. 2Look for a leak in the DEF lines, a blocked nozzle or a dosing valve that is stuck
    3. 3Repair the cause quickly because the next step is a harder power limit
    4. 4Verify the DEF quality sensor reading against a refractometer test
    5. 5Compare the DEF added at the last refill with the engine hours since, to see how fast it is being used.
    6. 6Log tank level, dosing demand and elapsed hours across one full shift to see the actual burn rate against the expected one
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB P2BAA-F1Consumption level 3 requested

    Inducement level 3 has been requested for excess DEF consumption or low reagent.· Other
    Check soon

    Causes

    • Low DEF level
    • Dosing valve stuck or lines leaking
    • DEF level sensor reading wrongly and hiding a leak
    • Countdown to the third limit has started
    • Consumption monitor reading wrong because the level sender is faulty

    Checks

    1. 1Check the tank level, then compare the measured DEF use against the commanded dose
    2. 2Look for a leak in the DEF lines, a blocked nozzle or a dosing valve that is stuck
    3. 3Repair now; the strongest limit is next, and the service tool is needed to clear it
    4. 4Check that the DEF was not topped up with water or a non-approved fluid
    5. 5Compare the DEF added at the last refill with the engine hours since, to see how fast it is being used.
    6. 6Log tank level, dosing demand and elapsed hours across one full shift to see the actual burn rate against the expected one
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB P2BA8-00Interruption warning requested

    A warning has been requested for an interruption of DEF dosing.· Other
    Info

    Causes

    • DEF pump or dosing valve not working
    • Frozen or blocked DEF line or nozzle
    • Crystallised DEF in the pump unit stopping flow
    • Warning raised long before the engine is limited
    • Dosing unit relay sticking so the pump never starts

    Checks

    1. 1Check that the DEF pump builds pressure and that the dosing valve opens during a dosing test
    2. 2Look for a frozen, blocked or kinked DEF line and a blocked dosing nozzle
    3. 3Repair the cause while only a warning is shown and clear the code after the repair
    4. 4Test the DEF level and temperature sensor readings against the real tank
    5. 5With the system pressurised, wait for the dosing cycle and see whether pressure drops, which shows urea is leaving the nozzle.
    6. 6Inspect the dosing nozzle bore with a borescope or after removal for crystal rings, and check the air assist line if fitted
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB P2BA8-F0Interruption level 2 requested

    Inducement level 2 has been requested for an interruption of DEF dosing.· Other
    Check soon

    Causes

    • DEF pump or dosing valve not working
    • Frozen or blocked DEF line or nozzle
    • Crystallised DEF in the pump unit stopping flow
    • Countdown to the second limit has started
    • Dosing unit relay sticking so the pump never starts

    Checks

    1. 1Check that the DEF pump builds pressure and that the dosing valve opens during a dosing test
    2. 2Look for a frozen, blocked or kinked DEF line and a blocked dosing nozzle
    3. 3Repair the cause quickly because the next step is a harder power limit
    4. 4Read the inducement history screen in the service tool for the last trigger time
    5. 5With the system pressurised, wait for the dosing cycle and see whether pressure drops, which shows urea is leaving the nozzle.
    6. 6Inspect the dosing nozzle bore with a borescope or after removal for crystal rings, and check the air assist line if fitted
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB P2BA8-F1Interruption level 3 requested

    Inducement level 3 has been requested for an interruption of DEF dosing.· Other
    Check soon

    Causes

    • DEF pump or dosing valve not working
    • Frozen or blocked DEF line or nozzle
    • Crystallised DEF in the pump unit stopping flow
    • Countdown to the third limit has started
    • Dosing unit relay sticking so the pump never starts

    Checks

    1. 1Check that the DEF pump builds pressure and that the dosing valve opens during a dosing test
    2. 2Look for a frozen, blocked or kinked DEF line and a blocked dosing nozzle
    3. 3Repair now; the strongest limit is next, and the service tool is needed to clear it
    4. 4Check the fuse for the DEF pump and heaters
    5. 5With the system pressurised, wait for the dosing cycle and see whether pressure drops, which shows urea is leaving the nozzle.
    6. 6Inspect the dosing nozzle bore with a borescope or after removal for crystal rings, and check the air assist line if fitted
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB P2BA8-9AInterruption level 3 enacted

    Inducement level 3 is enacted for an interruption of DEF dosing.· Other
    Check soon

    Causes

    • DEF pump or dosing valve not working
    • Frozen or blocked DEF line or nozzle
    • Crystallised DEF in the pump unit stopping flow
    • Machine may be limited to idle or a very low speed
    • Dosing unit relay sticking so the pump never starts

    Checks

    1. 1Check that the DEF pump builds pressure and that the dosing valve opens during a dosing test
    2. 2Look for a frozen, blocked or kinked DEF line and a blocked dosing nozzle
    3. 3After repair, clear the level 3 limit with the service tool and run the machine to confirm it does not return
    4. 4Check the NOx sensor readings against each other for plausibility
    5. 5With the system pressurised, wait for the dosing cycle and see whether pressure drops, which shows urea is leaving the nozzle.
    6. 6Inspect the dosing nozzle bore with a borescope or after removal for crystal rings, and check the air assist line if fitted
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB P2BA8-68Interruption level 2 enacted

    Inducement level 2 is enacted for an interruption of DEF dosing.· Other
    Check soon

    Causes

    • DEF pump or dosing valve not working
    • Frozen or blocked DEF line or nozzle
    • Crystallised DEF in the pump unit stopping flow
    • Torque limit is the harder second step
    • Dosing unit relay sticking so the pump never starts

    Checks

    1. 1Check that the DEF pump builds pressure and that the dosing valve opens during a dosing test
    2. 2Look for a frozen, blocked or kinked DEF line and a blocked dosing nozzle
    3. 3After repair, clear level 2 with the service tool and confirm that full torque is restored
    4. 4Check the aftertreatment controller software is current
    5. 5With the system pressurised, wait for the dosing cycle and see whether pressure drops, which shows urea is leaving the nozzle.
    6. 6Inspect the dosing nozzle bore with a borescope or after removal for crystal rings, and check the air assist line if fitted
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB P2BA8-92Interruption level 1 enacted

    Inducement level 1 is enacted for an interruption of DEF dosing.· Other
    Check soon

    Causes

    • DEF pump or dosing valve not working
    • Frozen or blocked DEF line or nozzle
    • Crystallised DEF in the pump unit stopping flow
    • Torque limit active from the first step
    • Dosing unit relay sticking so the pump never starts

    Checks

    1. 1Check that the DEF pump builds pressure and that the dosing valve opens during a dosing test
    2. 2Look for a frozen, blocked or kinked DEF line and a blocked dosing nozzle
    3. 3After repair, clear level 1 with the service tool and confirm that torque returns to normal
    4. 4Verify the DEF quality sensor reading against a refractometer test
    5. 5With the system pressurised, wait for the dosing cycle and see whether pressure drops, which shows urea is leaving the nozzle.
    6. 6Inspect the dosing nozzle bore with a borescope or after removal for crystal rings, and check the air assist line if fitted
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB P2BA8-94Interruption level 1 requested

    Inducement level 1 has been requested for an interruption of DEF dosing.· Other
    Check soon

    Causes

    • DEF pump or dosing valve not working
    • Frozen or blocked DEF line or nozzle
    • Crystallised DEF in the pump unit stopping flow
    • Countdown to the first limit has started
    • Dosing unit relay sticking so the pump never starts

    Checks

    1. 1Check that the DEF pump builds pressure and that the dosing valve opens during a dosing test
    2. 2Look for a frozen, blocked or kinked DEF line and a blocked dosing nozzle
    3. 3Repair the cause before the machine moves to the enacted level and clear the step with the service tool
    4. 4Check that the DEF was not topped up with water or a non-approved fluid
    5. 5With the system pressurised, wait for the dosing cycle and see whether pressure drops, which shows urea is leaving the nozzle.
    6. 6Inspect the dosing nozzle bore with a borescope or after removal for crystal rings, and check the air assist line if fitted
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB P2BA9-00Quality warning requested

    A warning has been requested for poor DEF quality.· Other
    Info

    Causes

    • Water or diesel in the DEF tank
    • DEF aged, diluted or the wrong fluid
    • DEF stored in a hot place so it degraded
    • Warning raised long before the engine is limited
    • Cheap or non-certified DEF containing impurities

    Checks

    1. 1Test the DEF in the tank with a refractometer and compare with the correct concentration
    2. 2Drain and flush the tank and refill with approved DEF if the fluid fails the test
    3. 3Repair the cause while only a warning is shown and clear the code after the repair
    4. 4Check the DEF return line for a leak or an air bubble in clear tubing
    5. 5If the fluid fails, drain and flush the tank twice and fill with certified DEF from a sealed container.
    6. 6Take a retained sample of the tank contents in a clean jar, look for cloudiness or oily films, and smell for ammonia strength
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB P2BA9-F0Quality level 2 requested

    Inducement level 2 has been requested for poor DEF quality.· Other
    Check soon

    Causes

    • Water or diesel in the DEF tank
    • DEF aged, diluted or the wrong fluid
    • DEF stored in a hot place so it degraded
    • Countdown to the second limit has started
    • Cheap or non-certified DEF containing impurities

    Checks

    1. 1Test the DEF in the tank with a refractometer and compare with the correct concentration
    2. 2Drain and flush the tank and refill with approved DEF if the fluid fails the test
    3. 3Repair the cause quickly because the next step is a harder power limit
    4. 4Run the DEF dosing test with the service tool and watch the pressure rise
    5. 5If the fluid fails, drain and flush the tank twice and fill with certified DEF from a sealed container.
    6. 6Take a retained sample of the tank contents in a clean jar, look for cloudiness or oily films, and smell for ammonia strength
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB P2BA9-F1Quality level 3 requested

    Inducement level 3 has been requested for poor DEF quality.· Other
    Check soon

    Causes

    • Water or diesel in the DEF tank
    • DEF aged, diluted or the wrong fluid
    • DEF stored in a hot place so it degraded
    • Countdown to the third limit has started
    • Cheap or non-certified DEF containing impurities

    Checks

    1. 1Test the DEF in the tank with a refractometer and compare with the correct concentration
    2. 2Drain and flush the tank and refill with approved DEF if the fluid fails the test
    3. 3Repair now; the strongest limit is next, and the service tool is needed to clear it
    4. 4Check the DEF line heaters when the ambient temperature is low
    5. 5If the fluid fails, drain and flush the tank twice and fill with certified DEF from a sealed container.
    6. 6Take a retained sample of the tank contents in a clean jar, look for cloudiness or oily films, and smell for ammonia strength
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB P2BA9-9AQuality level 3 enacted

    Inducement level 3 is enacted for poor DEF quality.· Other
    Check soon

    Causes

    • Water or diesel in the DEF tank
    • DEF aged, diluted or the wrong fluid
    • DEF stored in a hot place so it degraded
    • Machine may be limited to idle or a very low speed
    • Cheap or non-certified DEF containing impurities

    Checks

    1. 1Test the DEF in the tank with a refractometer and compare with the correct concentration
    2. 2Drain and flush the tank and refill with approved DEF if the fluid fails the test
    3. 3After repair, clear the level 3 limit with the service tool and run the machine to confirm it does not return
    4. 4Check that the DEF tank breather is open and the filler cap seals
    5. 5If the fluid fails, drain and flush the tank twice and fill with certified DEF from a sealed container.
    6. 6Take a retained sample of the tank contents in a clean jar, look for cloudiness or oily films, and smell for ammonia strength
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB P2BA9-68Quality level 2 enacted

    Inducement level 2 is enacted for poor DEF quality.· Other
    Check soon

    Causes

    • Water or diesel in the DEF tank
    • DEF aged, diluted or the wrong fluid
    • DEF stored in a hot place so it degraded
    • Torque limit is the harder second step
    • Cheap or non-certified DEF containing impurities

    Checks

    1. 1Test the DEF in the tank with a refractometer and compare with the correct concentration
    2. 2Drain and flush the tank and refill with approved DEF if the fluid fails the test
    3. 3After repair, clear level 2 with the service tool and confirm that full torque is restored
    4. 4Look for DEF crystals on fittings that show an old leak
    5. 5If the fluid fails, drain and flush the tank twice and fill with certified DEF from a sealed container.
    6. 6Take a retained sample of the tank contents in a clean jar, look for cloudiness or oily films, and smell for ammonia strength
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB P2BA9-92Quality level 1 enacted

    Inducement level 1 is enacted for poor DEF quality.· Other
    Check soon

    Causes

    • Water or diesel in the DEF tank
    • DEF aged, diluted or the wrong fluid
    • DEF stored in a hot place so it degraded
    • Torque limit active from the first step
    • Cheap or non-certified DEF containing impurities

    Checks

    1. 1Test the DEF in the tank with a refractometer and compare with the correct concentration
    2. 2Drain and flush the tank and refill with approved DEF if the fluid fails the test
    3. 3After repair, clear level 1 with the service tool and confirm that torque returns to normal
    4. 4Compare the DEF used in a test drive with the figure the controller expects
    5. 5If the fluid fails, drain and flush the tank twice and fill with certified DEF from a sealed container.
    6. 6Take a retained sample of the tank contents in a clean jar, look for cloudiness or oily films, and smell for ammonia strength
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB P2BA9-94Quality level 1 requested

    Inducement level 1 has been requested for poor DEF quality.· Other
    Check soon

    Causes

    • Water or diesel in the DEF tank
    • DEF aged, diluted or the wrong fluid
    • DEF stored in a hot place so it degraded
    • Countdown to the first limit has started
    • Cheap or non-certified DEF containing impurities

    Checks

    1. 1Test the DEF in the tank with a refractometer and compare with the correct concentration
    2. 2Drain and flush the tank and refill with approved DEF if the fluid fails the test
    3. 3Repair the cause before the machine moves to the enacted level and clear the step with the service tool
    4. 4Check the DEF filter in the pump unit for blockage
    5. 5If the fluid fails, drain and flush the tank twice and fill with certified DEF from a sealed container.
    6. 6Take a retained sample of the tank contents in a clean jar, look for cloudiness or oily films, and smell for ammonia strength
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB P2BAA-68Consumption level 2 enacted

    Inducement level 2 is enacted for excess DEF consumption or low reagent.· Other
    Check soon

    Causes

    • Low DEF level
    • Dosing valve stuck or lines leaking
    • DEF level sensor reading wrongly and hiding a leak
    • Torque limit is the harder second step
    • Consumption monitor reading wrong because the level sender is faulty

    Checks

    1. 1Check the tank level, then compare the measured DEF use against the commanded dose
    2. 2Look for a leak in the DEF lines, a blocked nozzle or a dosing valve that is stuck
    3. 3After repair, clear level 2 with the service tool and confirm that full torque is restored
    4. 4Check the DEF supply hose for kinks after any recent work
    5. 5Compare the DEF added at the last refill with the engine hours since, to see how fast it is being used.
    6. 6Log tank level, dosing demand and elapsed hours across one full shift to see the actual burn rate against the expected one
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB P2BAA-92Consumption level 1 enacted

    Inducement level 1 is enacted for excess DEF consumption or low reagent.· Other
    Check soon

    Causes

    • Low DEF level
    • Dosing valve stuck or lines leaking
    • DEF level sensor reading wrongly and hiding a leak
    • Torque limit active from the first step
    • Consumption monitor reading wrong because the level sender is faulty

    Checks

    1. 1Check the tank level, then compare the measured DEF use against the commanded dose
    2. 2Look for a leak in the DEF lines, a blocked nozzle or a dosing valve that is stuck
    3. 3After repair, clear level 1 with the service tool and confirm that torque returns to normal
    4. 4Test the DEF level and temperature sensor readings against the real tank
    5. 5Compare the DEF added at the last refill with the engine hours since, to see how fast it is being used.
    6. 6Log tank level, dosing demand and elapsed hours across one full shift to see the actual burn rate against the expected one
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB P2BAA-94Consumption level 1 requested (low reagent)

    Inducement level 1 has been requested for excess DEF consumption or low reagent.· Other
    Check soon

    Causes

    • Low DEF level
    • Dosing valve stuck or lines leaking
    • DEF level sensor reading wrongly and hiding a leak
    • Countdown to the first limit has started
    • Consumption monitor reading wrong because the level sender is faulty

    Checks

    1. 1Check the tank level, then compare the measured DEF use against the commanded dose
    2. 2Look for a leak in the DEF lines, a blocked nozzle or a dosing valve that is stuck
    3. 3Repair the cause before the machine moves to the enacted level and clear the step with the service tool
    4. 4Check the aftertreatment controller software is current
    5. 5Compare the DEF added at the last refill with the engine hours since, to see how fast it is being used.
    6. 6Log tank level, dosing demand and elapsed hours across one full shift to see the actual burn rate against the expected one
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

Shared checks

Checks, in order

  1. 1Find and fix the underlying SCR or DEF fault that caused this inducement step
  2. 2Check the DEF in the tank for level, colour and contamination
  3. 3Clear the codes after repair, run the machine and confirm the status does not return
  4. 4Check the DEF dosing system for blockage, pressure and valve faults

Causes

  • Underlying SCR or DEF fault not fixed
  • DEF empty or poor
  • Dosing interrupted
  • Tampering

When to stop

You'll notice: A warning shows and torque may be reduced.

Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.