JCB · Aftertreatment ECU - SCR / DEF

JCB DEF pumps and aftertreatment relays fault codes

The supply module pump moves DEF from the tank to the dosing valve, and the backflow pump reverses flow to empty the lines at shutdown. Each is driven by an electric motor.

More about these parts

The aftertreatment unit switches several actuators and heaters through numbered relay outputs. These codes report shorts or faults on those outputs.

FaultCheckP20A0-13JCB · DEF pumps and aftertreatment relays
Code shows hereFAULTP20A0-13

Where this code shows

Switch the key on and note any warning lamp or fault icon on the cluster.

What do these codes mean?

JCB codes P20A0-13 to P2686-12 are all about the dEF pumps and aftertreatment relays. The most common failure type is shorted low (7 of 26); none needs an immediate stop. Start with this check: check the DEF pump motor motor and its wiring for resistance, opens and shorts.

How urgent are they?

None of the 26 codes here means stop now; all 26 can wait until the shift ends, but find the cause before the next one.

  • Check soon26

What should I check first?

Check the DEF pump motor motor and its wiring for resistance, opens and shorts

Shared checks

26 of 26

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • JCB P20A0-13Backflow pump actuator powerstage open load

    Backflow pump actuator powerstage open load.· Open circuit
    Check soon

    Causes

    • Open wire or pushed-back pin between the controller and the backflow pump actuator powerstage open load
    • Backflow pump actuator powerstage open load coil, element or sensor internally open

    Checks

    1. 1Unplug the backflow pump actuator powerstage open load and measure across its pins, an open reading means the part is faulty
    2. 2Check continuity of each wire from the backflow pump actuator powerstage open load plug to the controller pin
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • JCB P20A1-4BBackflow pump actuator powerstage over temperature

    Backflow pump actuator powerstage over temperature.· Real condition
    Check soon

    Causes

    • Backflow pump actuator powerstage over temperature signal pulled high by a short to the 5 V reference or supply
    • Sensor or part failed giving a high reading

    Checks

    1. 1Read the backflow pump actuator powerstage over temperature value on live data and compare it with the expected value
    2. 2Unplug the backflow pump actuator powerstage over temperature and check the signal wire for a short to 5 V or battery
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • JCB P20A2-14Backflow pump actuator short to ground

    Backflow pump actuator short to ground.· Shorted low
    Check soon

    Causes

    • Wire for the backflow pump actuator short to ground chafed and touching chassis or engine ground
    • Backflow pump actuator short to ground coil or sensor shorted internally

    Checks

    1. 1Unplug the backflow pump actuator short to ground and check each wire for a short to chassis ground
    2. 2Measure the resistance of the backflow pump actuator short to ground and compare it with the manual value
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • JCB P20A3-13Backflow pump actuator short to battery

    Backflow pump actuator short to battery.· Shorted high
    Check soon

    Causes

    • Wire for the backflow pump actuator short to battery touching a battery-fed wire in the harness
    • Water or damage inside the backflow pump actuator short to battery connector bridging to supply

    Checks

    1. 1Unplug the backflow pump actuator short to battery and check the signal wire for voltage with the key on, any battery voltage means a short to supply
    2. 2Inspect the harness for chafing where it crosses live wires near the backflow pump actuator short to battery
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • JCB P21A9-12Actuator relay 4 short to battery

    Same fault as P0659-12 on actuator relay 4: the relay 4 output is shorted to battery voltage and cannot be controlled.· Shorted high
    Check soon

    Causes

    • Relay 4 output wire in contact with a live wire
    • Relay driver damaged in the controller

    Checks

    1. 1Unplug relay 4 and measure voltage on its output wire
    2. 2Check the harness for chafing on that circuit
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • JCB P21AB-14Actuator relay 4 short to ground

    Same fault as P0658-14 on actuator relay 4: the relay 4 output is pulled to ground and cannot be switched properly.· Shorted low
    Check soon

    Causes

    • Relay 4 output wire touching chassis ground
    • Relay 4 coil shorted internally

    Checks

    1. 1Unplug relay 4 and check its output wire for a short to ground
    2. 2Check the relay coil resistance against the manual value
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • JCB P208B-02Supply module pump speed permanent deviation

    Supply module pump speed permanent deviation.· Erratic or implausible
    Check soon

    Causes

    • Supply module pump speed permanent deviation drifting or worn so it no longer matches the real condition
    • Poor connection or high resistance in the supply module pump speed permanent deviation circuit
    • A related fault elsewhere making this reading look wrong

    Checks

    1. 1Compare the supply module pump speed permanent deviation value on live data with a known good value or a reference gauge
    2. 2Check the supply module pump speed permanent deviation connector and wiring for high resistance and intermittent contact
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • JCB P208B-4BSupply module pump motor over temperature

    Supply module pump motor over temperature.· Real condition
    Check soon

    Causes

    • Supply module pump motor over temperature signal pulled high by a short to the 5 V reference or supply
    • Sensor or part failed giving a high reading

    Checks

    1. 1Read the supply module pump motor over temperature value on live data and compare it with the expected value
    2. 2Unplug the supply module pump motor over temperature and check the signal wire for a short to 5 V or battery
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • JCB P208A-13Supply module pump motor open load

    Supply module pump motor open load.· Open circuit
    Check soon

    Causes

    • Open wire or pushed-back pin between the controller and the supply module pump motor open load
    • Supply module pump motor open load coil, element or sensor internally open

    Checks

    1. 1Unplug the supply module pump motor open load and measure across its pins, an open reading means the part is faulty
    2. 2Check continuity of each wire from the supply module pump motor open load plug to the controller pin
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • JCB P208D-13DEF supply pump motor short to battery

    DEF supply pump motor short to battery.· Shorted high
    Check soon

    Causes

    • Wire for the DEF supply pump motor short to battery touching a battery-fed wire in the harness
    • Water or damage inside the DEF supply pump motor short to battery connector bridging to supply

    Checks

    1. 1Unplug the DEF supply pump motor short to battery and check the signal wire for voltage with the key on, any battery voltage means a short to supply
    2. 2Inspect the harness for chafing where it crosses live wires near the DEF supply pump motor short to battery
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • JCB P208C-14Supply module pump motor short to ground

    Supply module pump motor short to ground.· Shorted low
    Check soon

    Causes

    • Wire for the supply module pump motor short to ground chafed and touching chassis or engine ground
    • Supply module pump motor short to ground coil or sensor shorted internally

    Checks

    1. 1Unplug the supply module pump motor short to ground and check each wire for a short to chassis ground
    2. 2Measure the resistance of the supply module pump motor short to ground and compare it with the manual value
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • JCB P208B-21Supply module duty cycle below minimum range

    Supply module duty cycle below minimum range.· Erratic or implausible
    Check soon

    Causes

    • Supply module duty cycle below minimum range drifting or worn so it no longer matches the real condition
    • Poor connection or high resistance in the supply module duty cycle below minimum range circuit
    • A related fault elsewhere making this reading look wrong

    Checks

    1. 1Compare the supply module duty cycle below minimum range value on live data with a known good value or a reference gauge
    2. 2Check the supply module duty cycle below minimum range connector and wiring for high resistance and intermittent contact
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • JCB P208B-22Supply module duty cycle in invalid range

    Supply module duty cycle in invalid range.· Erratic or implausible
    Check soon

    Causes

    • Supply module duty cycle in invalid range drifting or worn so it no longer matches the real condition
    • Poor connection or high resistance in the supply module duty cycle in invalid range circuit
    • A related fault elsewhere making this reading look wrong

    Checks

    1. 1Compare the supply module duty cycle in invalid range value on live data with a known good value or a reference gauge
    2. 2Check the supply module duty cycle in invalid range connector and wiring for high resistance and intermittent contact
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • JCB P208A-31DEF supply module pump feedback error

    DEF supply module pump feedback error.· Other
    Check soon

    Causes

    • DEF supply module pump feedback or its wiring faulty
    • Connector corrosion or a loose pin

    Checks

    1. 1Read the live data for the DEF supply module pump feedback and look for a value that is stuck or implausible
    2. 2Check the DEF supply module pump feedback connector and wiring for damage
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB P208B-61Supply module pump speed deviation error

    Supply module pump speed deviation error.· Erratic or implausible
    Check soon

    Causes

    • Supply module pump speed deviation drifting or worn so it no longer matches the real condition
    • Poor connection or high resistance in the supply module pump speed deviation circuit
    • A related fault elsewhere making this reading look wrong

    Checks

    1. 1Compare the supply module pump speed deviation value on live data with a known good value or a reference gauge
    2. 2Check the supply module pump speed deviation connector and wiring for high resistance and intermittent contact
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • JCB P208B-84Supply module motor speed duty cycle below minimum range

    Supply module motor speed duty cycle below minimum range.· Erratic or implausible
    Check soon

    Causes

    • Supply module motor speed duty cycle below minimum range drifting or worn so it no longer matches the real condition
    • Poor connection or high resistance in the supply module motor speed duty cycle below minimum range circuit
    • A related fault elsewhere making this reading look wrong

    Checks

    1. 1Compare the supply module motor speed duty cycle below minimum range value on live data with a known good value or a reference gauge
    2. 2Check the supply module motor speed duty cycle below minimum range connector and wiring for high resistance and intermittent contact
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • JCB P208B-85Supply module motor speed duty cycle above maximum range

    Supply module motor speed duty cycle above maximum range.· Erratic or implausible
    Check soon

    Causes

    • Supply module motor speed duty cycle above maximum range drifting or worn so it no longer matches the real condition
    • Poor connection or high resistance in the supply module motor speed duty cycle above maximum range circuit
    • A related fault elsewhere making this reading look wrong

    Checks

    1. 1Compare the supply module motor speed duty cycle above maximum range value on live data with a known good value or a reference gauge
    2. 2Check the supply module motor speed duty cycle above maximum range connector and wiring for high resistance and intermittent contact
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • JCB P219D-4BDEF heater relay driver overtemperature

    The DEF heater relay driver in the controller overheated.· Real condition
    Check soon

    Causes

    • Relay coil shorted partially, drawing too much current
    • Controller driver failing

    Checks

    1. 1Measure the relay coil resistance; a very low value points to a shorted coil
    2. 2Check the relay driver current if the tool can show it
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • JCB P219D-13DEF heater relay driver open load

    The DEF heater relay driver sees an open load: no current path through the relay coil, so the heater cannot be switched.· Open circuit
    Check soon

    Causes

    • Open coil or broken wire at the DEF heater relay
    • Relay plug corroded or pin pushed back

    Checks

    1. 1Check the relay coil resistance and the wiring to the controller for an open circuit
    2. 2Inspect the relay socket pins
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • JCB P219E-13DEF heater relay short to battery

    The DEF heater relay output is shorted to battery voltage and the controller cannot switch the heater circuit off.· Shorted high
    Check soon

    Causes

    • Relay output wire in contact with a live wire
    • Relay driver damaged in the controller

    Checks

    1. 1Unplug the relay and measure voltage on the output wire
    2. 2Inspect the harness for chafing
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • JCB P219F-14DEF heater relay driver short to ground

    The DEF heater relay driver output is shorted to ground and cannot be switched.· Shorted low
    Check soon

    Causes

    • Relay output wire touching chassis or engine ground
    • Relay coil shorted internally

    Checks

    1. 1Unplug the relay and check the output wire to ground
    2. 2Measure the relay coil resistance
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • JCB P0658-14Actuator relay 1 short to ground

    Actuator relay 1 output is pulled to ground: the aftertreatment controller drives the relay coil and finds the output stuck low, so it cannot be switched properly.· Shorted low
    Check soon

    Causes

    • Wire to relay 1 chafed against chassis or the frame
    • Relay 1 coil shorted internally

    Checks

    1. 1Unplug relay 1 and check the coil wire for a short to ground
    2. 2Measure the relay coil resistance and compare it with the manual value
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • JCB P0659-12Actuator relay 1 short to battery

    Actuator relay 1 output is shorted to battery voltage: the output reads high all the time and the relay cannot be controlled.· Shorted high
    Check soon

    Causes

    • Relay 1 output wire touching a live wire
    • Relay 1 driver damaged in the controller

    Checks

    1. 1Unplug relay 1 and check the output wire for voltage with the key on
    2. 2Look for a chafed harness section against another live feed
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • JCB P2670-14Actuator relay 2 short to ground

    Same fault as P0658-14 on actuator relay 2: the relay 2 output is pulled to ground and cannot be switched properly.· Shorted low
    Check soon

    Causes

    • Relay 2 output wire touching chassis ground
    • Relay 2 coil shorted internally

    Checks

    1. 1Unplug relay 2 and check its output wire for a short to ground
    2. 2Check the relay coil resistance against the manual value
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • JCB P2685-14Actuator relay 3 short to ground

    Same fault as P0658-14 on actuator relay 3: the relay 3 output is pulled to ground and cannot be switched properly.· Shorted low
    Check soon

    Causes

    • Relay 3 output wire touching chassis ground
    • Relay 3 coil shorted internally

    Checks

    1. 1Unplug relay 3 and check its output wire for a short to ground
    2. 2Check the relay coil resistance against the manual value
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • JCB P2686-12Actuator relay 3 short to battery

    Same fault as P0659-12 on actuator relay 3: the relay 3 output is shorted to battery voltage and cannot be controlled.· Shorted high
    Check soon

    Causes

    • Relay 3 output wire in contact with a live wire
    • Relay driver damaged in the controller

    Checks

    1. 1Unplug relay 3 and measure voltage on its output wire
    2. 2Check the harness for chafing on that circuit
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

Shared checks

Checks, in order

  1. 1Check the DEF pump motor motor and its wiring for resistance, opens and shorts
  2. 2Check the relay and wiring (on the aftertreatment relay, with the diagnostic tool and a multimeter)
  3. 3Look for DEF crystals or blockage in the DEF pump motor and its lines
  4. 4Check the actuator (on the aftertreatment relay, with the diagnostic tool and a multimeter)
  5. 5Measure the supply voltage at the DEF pump motor plug with the pump commanded on
  6. 6Check the aftertreatment relay driver output on the diagnostic tool and measure it at the plug
  7. 7Run the pump test on the diagnostic tool (on the DEF pump motor, with the diagnostic tool and a multimeter)

Causes

  • Pump motor failed
  • Relay or actuator failed
  • Wiring fault
  • Wiring short

Most common here: shorted low (7 of 26)

Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

When to stop

You'll notice: A DEF warning shows, and dosing may stop.

Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.