JCB · Aftertreatment ECU - SCR / DEF

JCB DEF quality, quality sensor temperature and SCR efficiency fault codes

The quality sensor checks the DEF concentration and temperature. Wrong concentration, from water or another fluid, triggers inducement.

More about these parts

These codes report that the SCR catalyst is not cutting NOx as expected or is blocked.

FaultCheckP207F-00JCB · DEF quality, quality sensor temperature and SCR efficiency
Code shows hereFAULTP207F-00

Where this code shows

Switch the key on and note any warning lamp or fault icon on the cluster.

What do these codes mean?

JCB codes P207F-00 to P3425 are all about the dEF quality, quality sensor temperature and SCR efficiency. The most common failure type is real condition (6 of 19); none needs an immediate stop. Start with this check: check the DEF with a refractometer (on the DEF quality sensor, with the diagnostic tool and a multimeter).

How urgent are they?

None of the 19 codes here means stop now; all 19 can wait until the shift ends, but find the cause before the next one.

  • Check soon19

What should I check first?

Check the DEF with a refractometer (on the DEF quality sensor, with the diagnostic tool and a multimeter)

Shared checks

19 of 19

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • JCB P207F-00DEF quality error

    The aftertreatment system reports poor DEF quality, usually found after a refill.· Real condition
    Check soon

    Causes

    • Diluted DEF or water added to the tank
    • Wrong fluid, such as plain water or contaminated fluid, in the DEF tank
    • Old DEF that has degraded after long storage or heat
    • Quality sensor faulty or its wiring damaged
    • DEF contaminated by dirt from a dirty funnel or container

    Checks

    1. 1Sample the DEF and check it with a refractometer for the correct concentration
    2. 2Drain and flush the tank and refill with fresh DEF if the sample fails
    3. 3Check the DEF container and funnel were clean and sealed
    4. 4Check the DEF quality sensor connector and wiring
    5. 5Check the fluid date and storage conditions of the container
    6. 6Clear the fault after refilling and run the system to confirm it passes
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • JCB P207F-86DEF concentration message error from head unit (invalid signal)

    DEF concentration message error from head unit (invalid signal).· Lost message
    Check soon

    Causes

    • CAN wiring open, shorted or wet at a connector
    • The sending module not powered, reset or faulty

    Checks

    1. 1Check the CAN high and low wiring and the 120 ohm termination
    2. 2Check that the sending module has power, earth and no active faults of its own
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • JCB P207F-87DEF quality message error from head unit

    DEF quality message error from head unit.· Lost message
    Check soon

    Causes

    • CAN wiring open, shorted or wet at a connector
    • The sending module not powered, reset or faulty

    Checks

    1. 1Check the CAN high and low wiring and the 120 ohm termination
    2. 2Check that the sending module has power, earth and no active faults of its own
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • JCB P2000-00SCR conversion efficiency below threshold

    The SCR catalyst is not converting enough NOx, measured by the downstream NOx sensor.· Other
    Check soon

    Causes

    • Poor DEF quality or low DEF dosing
    • Dosing valve blocked or dosing too little
    • Downstream NOx sensor faulty or dirty

    Checks

    1. 1Check the DEF quality with a refractometer before anything else
    2. 2Inspect the dosing valve nozzle for crystals and test the dosing output
    3. 3Check both NOx sensors for faults and read their live values
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB P2000-02SCR conversion efficiency below threshold

    SCR conversion efficiency below threshold.· Erratic or implausible
    Check soon

    Causes

    • SCR conversion efficiency below threshold drifting or worn so it no longer matches the real condition
    • Poor connection or high resistance in the SCR conversion efficiency below threshold circuit
    • A related fault elsewhere making this reading look wrong

    Checks

    1. 1Compare the SCR conversion efficiency below threshold value on live data with a known good value or a reference gauge
    2. 2Check the SCR conversion efficiency below threshold connector and wiring for high resistance and intermittent contact
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • JCB P2000-04SCR conversion efficiency below threshold (system internal failure)

    SCR conversion efficiency below threshold (system internal failure).· Erratic or implausible
    Check soon

    Causes

    • SCR conversion efficiency below threshold drifting or worn so it no longer matches the real condition
    • Poor connection or high resistance in the SCR conversion efficiency below threshold circuit
    • A related fault elsewhere making this reading look wrong

    Checks

    1. 1Compare the SCR conversion efficiency below threshold value on live data with a known good value or a reference gauge
    2. 2Check the SCR conversion efficiency below threshold connector and wiring for high resistance and intermittent contact
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • JCB P2000-06SCR conversion efficiency below threshold

    SCR conversion efficiency below threshold.· Erratic or implausible
    Check soon

    Causes

    • SCR conversion efficiency below threshold drifting or worn so it no longer matches the real condition
    • Poor connection or high resistance in the SCR conversion efficiency below threshold circuit
    • A related fault elsewhere making this reading look wrong

    Checks

    1. 1Compare the SCR conversion efficiency below threshold value on live data with a known good value or a reference gauge
    2. 2Check the SCR conversion efficiency below threshold connector and wiring for high resistance and intermittent contact
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • JCB P3401-87Excessive SCR catalyst DEF temperature error

    Excessive SCR catalyst DEF temperature error.· Other
    Check soon

    Causes

    • Excessive SCR catalyst DEF temperature signal pulled high by a short to the 5 V reference or supply
    • Sensor or part failed giving a high reading

    Checks

    1. 1Read the excessive SCR catalyst DEF temperature value on live data and compare it with the expected value
    2. 2Unplug the excessive SCR catalyst DEF temperature and check the signal wire for a short to 5 V or battery
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB P3402-87DEF concentration too high

    DEF concentration too high.· Real condition
    Check soon

    Causes

    • DEF concentration too signal pulled high by a short to the 5 V reference or supply
    • Sensor or part failed giving a high reading

    Checks

    1. 1Read the DEF concentration too value on live data and compare it with the expected value
    2. 2Unplug the DEF concentration too and check the signal wire for a short to 5 V or battery
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • JCB P3403-87DEF concentration too low

    DEF concentration too low.· Real condition
    Check soon

    Causes

    • DEF concentration too signal pulled low by a short to ground or an open supply
    • Sensor or part failed giving a low reading

    Checks

    1. 1Read the DEF concentration too value on live data and compare it with the expected value
    2. 2Unplug the DEF concentration too and check the signal wire for a short to ground and the supply for 5 V
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • JCB P3404-87Excessive DEF temperature in SCR system

    Excessive DEF temperature in SCR system.· Other
    Check soon

    Causes

    • Excessive DEF temperature in SCR system signal pulled high by a short to the 5 V reference or supply
    • Sensor or part failed giving a high reading

    Checks

    1. 1Read the excessive DEF temperature in SCR system value on live data and compare it with the expected value
    2. 2Unplug the excessive DEF temperature in SCR system and check the signal wire for a short to 5 V or battery
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB P3405-87DEF temperature too high for SCR catalyst

    DEF temperature too high for SCR catalyst.· Real condition
    Check soon

    Causes

    • DEF temperature too high for SCR catalyst signal pulled high by a short to the 5 V reference or supply
    • Sensor or part failed giving a high reading

    Checks

    1. 1Read the DEF temperature too high for SCR catalyst value on live data and compare it with the expected value
    2. 2Unplug the DEF temperature too high for SCR catalyst and check the signal wire for a short to 5 V or battery
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • JCB P3406-87DEF temperature too low for SCR catalyst

    DEF temperature too low for SCR catalyst.· Real condition
    Check soon

    Causes

    • DEF temperature too low for SCR catalyst signal pulled low by a short to ground or an open supply
    • Sensor or part failed giving a low reading

    Checks

    1. 1Read the DEF temperature too low for SCR catalyst value on live data and compare it with the expected value
    2. 2Unplug the DEF temperature too low for SCR catalyst and check the signal wire for a short to ground and the supply for 5 V
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • JCB P3407-87DEF temperature sensor open circuit

    DEF temperature sensor open circuit.· Open circuit
    Check soon

    Causes

    • Open wire or pushed-back pin between the controller and the DEF temperature sensor
    • DEF temperature sensor coil, element or sensor internally open

    Checks

    1. 1Unplug the DEF temperature sensor and measure across its pins, an open reading means the part is faulty
    2. 2Check continuity of each wire from the DEF temperature sensor plug to the controller pin
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • JCB P3408-87SCR DEF temperature sensor short circuit

    SCR DEF temperature sensor short circuit.· Short circuit
    Check soon

    Causes

    • SCR DEF temperature sensor coil shorted internally, drawing too much current
    • Harness chafed through and touching the frame or a supply wire near the SCR DEF temperature sensor
    • Water in the SCR DEF temperature sensor connector

    Checks

    1. 1Unplug the SCR DEF temperature sensor and measure its resistance, looking for a very low reading
    2. 2Check each wire for a short to ground and to battery with the plug removed
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.

    Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.

  • JCB P3409-87Excessive ambient or operating level error for DEF properties

    Excessive ambient or operating level error for DEF properties.· Other
    Check soon

    Causes

    • Excessive ambient or operating level error for DEF properties signal pulled high by a short to the 5 V reference or supply
    • Sensor or part failed giving a high reading

    Checks

    1. 1Read the excessive ambient or operating level error for DEF properties value on live data and compare it with the expected value
    2. 2Unplug the excessive ambient or operating level error for DEF properties and check the signal wire for a short to 5 V or battery
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB P3410-87DEF level too high

    DEF level too high.· Real condition
    Check soon

    Causes

    • DEF level too signal pulled high by a short to the 5 V reference or supply
    • Sensor or part failed giving a high reading

    Checks

    1. 1Read the DEF level too value on live data and compare it with the expected value
    2. 2Unplug the DEF level too and check the signal wire for a short to 5 V or battery
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • JCB P3424SCR partially blocked (overloaded)

    SCR partially blocked (overloaded).· Erratic or implausible
    Check soon

    Causes

    • SCR partially blocked drifting or worn so it no longer matches the real condition
    • Poor connection or high resistance in the SCR partially blocked circuit
    • A related fault elsewhere making this reading look wrong

    Checks

    1. 1Compare the SCR partially blocked value on live data with a known good value or a reference gauge
    2. 2Check the SCR partially blocked connector and wiring for high resistance and intermittent contact
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • JCB P3425SCR fully blocked (plugged)

    SCR fully blocked (plugged).· Erratic or implausible
    Check soon

    Causes

    • SCR fully blocked drifting or worn so it no longer matches the real condition
    • Poor connection or high resistance in the SCR fully blocked circuit
    • A related fault elsewhere making this reading look wrong

    Checks

    1. 1Compare the SCR fully blocked value on live data with a known good value or a reference gauge
    2. 2Check the SCR fully blocked connector and wiring for high resistance and intermittent contact
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

Shared checks

Checks, in order

  1. 1Check the DEF with a refractometer (on the DEF quality sensor, with the diagnostic tool and a multimeter)
  2. 2Check for dosing and DEF faults (on the SCR catalyst, with the diagnostic tool and a multimeter)
  3. 3Drain and refill with correct DEF if it is wrong
  4. 4Check both NOx sensors for faults and plausible readings
  5. 5Check the DEF quality sensor wiring for opens, shorts and corroded connector pins
  6. 6Inspect the SCR catalyst for blockage, damage and contamination
  7. 7Check the DEF temperature against the expected range

Causes

  • Wrong or diluted DEF in the tank
  • SCR catalyst contaminated or blocked
  • Quality sensor failed
  • Dosing or DEF fault

Most common here: real condition (6 of 19)

Check the real value with a separate gauge or thermometer before blaming the sensor.

When to stop

You'll notice: A DEF quality warning shows and power may be reduced.

Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.