EF Logo

Deutz · Exhaust aftertreatment (SCR)

Deutz Fault Code SPN 4375 FMI 3

Exhaust aftertreatment - DEF pump - Voltage above normal or shorted to high source

What does Deutz code SPN 4375 FMI 3 mean?

The EMR4 sees the output for the DEF pump (in the SCR dosing module that pumps DEF (AdBlue) to the dosing valve) at a voltage above normal, as if the circuit is shorted to the battery supply. The controller cannot drive the actuator correctly. Urgency: check soon - the machine may derate or limit a function. Check first: measure the winding or coil resistance of the part.

FaultCheckSPN 4375FMI 3Deutz · Exhaust aftertreatment (SCR)
FMI 3
Voltage above normal or shorted high

Can I keep running with it?

Check soon

The machine may derate or limit a function. Find the cause before the next shift.

What should I check first?

Measure the winding or coil resistance of the part

Then 3 more checks
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Read the active and stored faults with Deutz SerDia (or the machine maker's diagnostic tool) on the engine diagnostic plug.

Checks

0 of 4 done

Causes

  • Output wire shorted to battery positive
  • DEF pump shorted internally
  • Connector pin touching a live pin

How it failed

You'll notice: Expect a warning lamp; DEF cannot be pumped to the dosing valve, so NOx rises; the SCR lamp comes on and power may be reduced after a countdown.

Shorted highRead from FMI 3: voltage above normal or shorted high

The signal sits at or near the supply voltage - more than a working sensor can send.

ControllerPartSupplySignalGround
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.
Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good result
Open circuit (OL) between them. Any low reading is the short.

When to stop

Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.

Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Same part, other failures: DEF pump, metering unit and suction unit

2 other codes on this part are also shorted high (SPN 3361 FMI 3, SPN 4376 FMI 3). When they show together, start at the wiring and connector they share.

Show the other 13 codes
All 22 DEF pump, metering unit and suction unit codes on one page

Source

DEUTZ KWP-Codes EMR4 (KWPList EMR4 DE EN, Revision 2.0), page 24

This source lists SPN 4375 FMI 3 and its meaning. The guidance on this page is general, not taken from it.

The source covers: Deutz engines with the EMR4 controller (the Deutz list applies to all EMR4 engine series, e.g. TCD 2.9, 3.6, 4.1, 6.1, 7.8 as fitted in machines).

Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.