Deutz SCR system output, catalyst temperature and pressure sensors fault codes

The SCR catalyst and its sensors: the SCR system output of the EMR4, the catalyst temperature sensors before and after the catalyst, the pressure sensor before the catalyst, and the EPA counter event. The EMR4 uses them to decide when dosing is allowed and how well the catalyst works.

FaultCheckSPN 523633FMI 11Deutz · Efficiency SCR system
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Read the active and stored faults with Deutz SerDia (or the machine maker's diagnostic tool) on the engine diagnostic plug.

What do these codes mean?

Deutz codes SPN 3241 FMI 0 to SPN 524175 FMI 0 are all about the sCR system output, catalyst temperature and pressure sensors. The most common failure type is real condition (6 of 19); none needs an immediate stop. Start with this check: read the catalyst temperatures and pressure in SerDia and compare them with the engine state.

How urgent are they?

None of the 19 codes here means stop now; 18 can wait until the shift ends, but find the cause before the next one; 1 is information only.

  • Check soon18
  • Info1

What should I check first?

Read the catalyst temperatures and pressure in SerDia and compare them with the engine state

Shared checks

19 of 19

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Temperature before SCR Cat4 codes

    • Deutz SPN 3241 FMI 0Temperature before SCR Cat: Reading too high· most severe

      The temperature before the SCR catalyst (second sensor) (in the exhaust ahead of the SCR catalyst) reports a temperature above the allowed operating range.· Real condition
      Check soon

      Causes

      • Sensor drifting low in resistance with age
      • Partial short or wet connector lowering the temperature before the SCR catalyst (second sensor) resistance so it reads hot
      • Soot build-up on the sensor tip

      Checks

      1. 1Check the connector pins for moisture and corrosion, which can pull a reading hot
      2. 2Check the real temperature with an infrared thermometer or mechanical gauge before touching the temperature before the SCR catalyst (second sensor)
      3. 3Look in SerDia at the temperature before the SCR catalyst (second sensor) reading next to a neighbouring temperature; a lone hot value points at the sensor
      4. 4Compare this reading with the DPF outlet temperature in SerDia for plausibility
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Exhaust aftertreatment - Temperature before SCR Cat - Data above normal operational range (Most severe level)

    • Deutz SPN 4360 FMI 0Temperature before SCR Cat: Reading too high· most severe

      The temperature before the SCR catalyst (in the exhaust ahead of the SCR catalyst) reports a temperature above the allowed operating range.· Real condition
      Check soon

      Causes

      • Partial short or wet connector lowering the temperature before the SCR catalyst resistance so it reads hot
      • Soot contamination on the sensor tip
      • Sensor drifting low in resistance with age

      Checks

      1. 1Look in SerDia at the temperature before the SCR catalyst reading next to a neighbouring temperature; a lone hot value points at the sensor
      2. 2Check the connector pins for moisture and corrosion, which can pull a reading hot
      3. 3Compare the before-SCR reading with DPF outlet temperature in SerDia; they should be close in steady state
      4. 4Check the real temperature with an infrared thermometer or mechanical gauge before touching the temperature before the SCR catalyst
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Exhaust aftertreatment - Temperature before SCR Cat - Data above normal operational range (Most severe level)

    • Deutz SPN 4360 FMI 1Temperature before SCR Cat: Reading too low· most severe

      The temperature before the SCR catalyst (in the exhaust ahead of the SCR catalyst) reports a temperature below the allowed range.· Real condition
      Check soon

      Causes

      • High resistance in the temperature before the SCR catalyst connector or a corroded pin making it read cold
      • Sensor drifting high in resistance after heat cycles
      • Soot contamination on the sensor tip

      Checks

      1. 1Check the sensor mounting thread for exhaust leaks that cool or disturb the reading
      2. 2Compare the temperature before the SCR catalyst value in SerDia with a neighbouring temperature; if only this one is cold the circuit is suspect
      3. 3Compare the before-SCR reading with DPF outlet temperature in SerDia; they should be close in steady state
      4. 4Measure voltage drop across the connector with the engine running to find a high-resistance joint
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Exhaust aftertreatment - Temperature before SCR Cat - Data below normal operational range (Most severe level)

    • Deutz SPN 4360 FMI 2Temperature before SCR Cat: Erratic reading

      The EMR4 sees the temperature before the SCR catalyst (in the exhaust ahead of the SCR catalyst) jump around or disagree with other temperatures.· Erratic or implausible
      Check soon

      Causes

      • Intermittent contact in the connector or a pin with fretting
      • Harness chafed in a spot that makes contact only under vibration
      • Sensor element on its way out in the temperature before the SCR catalyst

      Checks

      1. 1Watch the temperature before the SCR catalyst value in SerDia while wiggling the harness and connector, and note when it jumps
      2. 2Inspect the connector for loose pins, bent terminals and moisture
      3. 3Check the harness along its route for chafe, especially where it crosses a bracket
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Exhaust aftertreatment - Temperature before SCR Cat - Data erratic intermittent or incorrect

  • Dynamic temperature check before SCR1 code

    • Deutz SPN 4361 FMI 2Dynamic temperature check before SCR: Erratic reading

      The EMR4 sees the SCR catalyst temperature (in the SCR catalyst housing) jump around or disagree with other temperatures.· Erratic or implausible
      Check soon

      Causes

      • Intermittent contact in the connector or a pin with fretting
      • Harness chafed in a spot that makes contact only under vibration
      • Sensor element on its way out in the SCR catalyst temperature

      Checks

      1. 1Watch the SCR catalyst temperature value in SerDia while wiggling the harness and connector, and note when it jumps
      2. 2Inspect the connector for loose pins, bent terminals and moisture
      3. 3Check the harness along its route for chafe, especially where it crosses a bracket
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Exhaust aftertreatment - Dynamic temperature check before SCR - Data erratic intermittent or incorrect

  • Temperature SCR Cat2 codes

    • Deutz SPN 4361 FMI 3Temperature SCR Cat: Voltage high / shorted high

      The EMR4 reads the SCR catalyst temperature (in the SCR catalyst housing) at a voltage above its valid window.· Shorted high
      Check soon

      Causes

      • Open circuit: broken wire, pushed-out pin or an unplugged connector at the SCR catalyst temperature
      • Sensor element failed open, so its resistance stays very high at any temperature
      • Signal wire touching a supply voltage somewhere in the harness

      Checks

      1. 1Unplug the SCR catalyst temperature and measure its resistance across the two pins; an NTC that reads open at room temperature is finished
      2. 2Bridge the two harness pins with a jumper wire with the key on; the code should change to the voltage-below-normal one if the harness is sound
      3. 3With the sensor unplugged and key on, check the signal pin for battery voltage, which would mean a short to supply
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Exhaust aftertreatment - Temperature SCR Cat - Voltage above normal or shorted to high source

    • Deutz SPN 4361 FMI 4Temperature SCR Cat: Voltage low / shorted low

      The EMR4 reads the SCR catalyst temperature (in the SCR catalyst housing) at a voltage below its valid window.· Shorted low
      Check soon

      Causes

      • Signal wire rubbed through to the engine block or frame
      • Sensor element shorted internally, so it reads as extremely hot
      • Water bridging the pins inside the SCR catalyst temperature connector

      Checks

      1. 1Unplug the SCR catalyst temperature with the key on: if the code flips to the voltage-above-normal one, the harness is fine and the sensor is the shorted part
      2. 2With the EMR4 unplugged, measure resistance from the signal pin to ground; anything but open points to a short in the wire
      3. 3Measure the SCR catalyst temperature resistance and compare it with its temperature; a very low value means the element is shorted
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Exhaust aftertreatment - Temperature SCR Cat - Voltage below normal or shorted to low source

  • Efficiency SCR system1 code

    • Deutz SPN 523633 FMI 11Efficiency SCR system: Root cause not known

      The EMR4 reports the SCR efficiency fault with unknown root cause.· Other
      Check soon

      Causes

      • Poor DEF quality or empty tank
      • Dosing valve partly blocked
      • Catalyst aged or contaminated
      • NOx sensor reading wrong

      Checks

      1. 1Check the DEF level and quality with a refractometer, since weak DEF is the most common cause of poor SCR efficiency
      2. 2Check the DEF dosing valve for crystals and watch its spray pattern during a dosing test
      3. 3Compare the upstream and downstream NOx sensors for plausibility
      4. 4Check the exhaust for leaks upstream of the SCR catalyst
      5. 5Check the SCR catalyst history for contamination if everything else tests good
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • SCR system4 codes

    • Deutz SPN 523718 FMI 3SCR system: Voltage high / shorted high

      The EMR4 sees the output for the SCR system output (at the SCR control outputs of the EMR4) at a voltage above normal, as if the circuit is shorted to the battery supply.· Shorted high
      Check soon

      Causes

      • Output wire shorted to battery positive
      • Connector pin touching a live pin
      • SCR system output shorted internally

      Checks

      1. 1Unplug the SCR system output: if the code stays, the short is in the harness or the EMR4; if it clears, the part is the shorted one
      2. 2With the EMR4 unplugged, measure the output wire to battery positive; it should be open
      3. 3Measure the winding or coil resistance of the part
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Exhaust aftertreatment - SCR system - Voltage above normal or shorted to high source

    • Deutz SPN 523718 FMI 4SCR system: Voltage low / shorted low

      The EMR4 sees the output for the SCR system output (at the SCR control outputs of the EMR4) at a voltage below normal, as if the circuit is shorted to ground.· Shorted low
      Check soon

      Causes

      • Output wire chafed to ground or the engine block
      • SCR system output winding shorted to its housing
      • Water in the connector bridging the pins

      Checks

      1. 1Unplug the SCR system output: if the code changes, the part is the shorted one; if it stays, look at the harness
      2. 2With the EMR4 unplugged, measure the output wire to ground; it should not be low ohms
      3. 3Measure the winding resistance of the part and look for a very low value
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Exhaust aftertreatment - SCR system - Voltage below normal or shorted to low source

    • Deutz SPN 523718 FMI 5SCR system: Current low / open circuit

      The EMR4 sees too little current through the SCR system output (at the SCR control outputs of the EMR4), which means the circuit is open.· Open circuit
      Check soon

      Causes

      • Broken wire or a pin pushed out of the connector
      • SCR system output winding open
      • Connector left unplugged after earlier work

      Checks

      1. 1Measure the resistance across the SCR system output terminals: infinity means an open winding
      2. 2Continuity-test each wire to the matching EMR4 pin
      3. 3Inspect both ends of the SCR system output circuit (EMR4 plug and part connector) for pins pushed back in the housing
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

      Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

      Source wording:Exhaust aftertreatment - SCR system - Current below normal or open circuit

    • Deutz SPN 523718 FMI 12SCR system: Bad device or component

      The EMR4 judges the SCR system output (at the SCR control outputs of the EMR4) to be a bad device, meaning the part or its driver electronics no longer respond as a working component.· Part or controller
      Check soon

      Causes

      • Internal failure of the SCR system output
      • Water or soot inside the part
      • Driver stage in the EMR4 failing

      Checks

      1. 1Read the SCR system output status in SerDia and run any actuator test
      2. 2Measure supply voltage and ground at the SCR system output connector with the key on to confirm the part is powered
      3. 3Fit a known good SCR system output if you can borrow one and see whether the code clears for good
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Exhaust aftertreatment - SCR system - Bad intelligent device or component

  • Pressure sensor before SCR Cat5 codes

    • Deutz SPN 524065 FMI 0Pressure sensor before SCR Cat: Reading too high· most severe

      The pressure sensor before SCR Cat (in the exhaust before the SCR catalyst) reports a value above the allowed range.· Real condition
      Check soon

      Causes

      • Pressure sensor before SCR Cat drifting high or reading with an offset
      • Hose or port feeding the sensor blocked with dirt

      Checks

      1. 1Check the real value against a mechanical gauge or second reading before touching the pressure sensor before SCR Cat
      2. 2Compare with its neighbouring sensors in SerDia to see whether only this value is off
      3. 3Inspect the sensor port or hose for restriction
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Exhaust aftertreatment - Pressure sensor before SCR Cat - Data above normal operational range (Most severe level)

    • Deutz SPN 524065 FMI 1Pressure sensor before SCR Cat: Reading too low· most severe

      The pressure sensor before SCR Cat (in the exhaust before the SCR catalyst) reports a value below the allowed range.· Real condition
      Check soon

      Causes

      • Pressure sensor before SCR Cat drifting low or reading with an offset
      • Hose or port feeding the sensor split or disconnected

      Checks

      1. 1Check the real value with a mechanical gauge before replacing the pressure sensor before SCR Cat
      2. 2Compare with its neighbouring sensors in SerDia to see whether only this value is off
      3. 3Inspect the sensor port, hose and seal for leaks
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Exhaust aftertreatment - Pressure sensor before SCR Cat - Data below normal operational range (Most severe level)

    • Deutz SPN 524065 FMI 2Pressure sensor before SCR Cat: Erratic reading

      The EMR4 sees the pressure sensor before SCR Cat (in the exhaust before the SCR catalyst) signal jump or disagree with other values.· Erratic or implausible
      Check soon

      Causes

      • Intermittent contact in the connector
      • Harness chafed against a bracket in a spot that only touches under vibration
      • Pressure sensor before SCR Cat on its way out

      Checks

      1. 1Watch the pressure sensor before SCR Cat value in SerDia while wiggling the connector and harness
      2. 2Inspect the connector for loose pins, bent terminals and moisture
      3. 3Check the 5 V reference for dips while the fault shows
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Exhaust aftertreatment - Pressure sensor before SCR Cat - Data erratic intermittent or incorrect

    • Deutz SPN 524065 FMI 3Pressure sensor before SCR Cat: Voltage high / shorted high

      The EMR4 reads the pressure sensor before SCR Cat (in the exhaust before the SCR catalyst) signal above its valid 0.5 to 4.5 V window.· Shorted high
      Check soon

      Causes

      • Open ground return wire, which pushes the signal up to the reference
      • Signal wire touching 5 V or battery in the harness
      • Pressure sensor before SCR Cat failed high

      Checks

      1. 1Key on: measure the 5 V reference at the pressure sensor before SCR Cat plug between supply and ground; 5 V present means the supply side is fine
      2. 2Check continuity of the sensor ground wire back to the EMR4 pin
      3. 3With the sensor unplugged, measure the signal pin; battery voltage there means a short to supply
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Exhaust aftertreatment - Pressure sensor before SCR Cat - Voltage above normal or shorted to high source

    • Deutz SPN 524065 FMI 4Pressure sensor before SCR Cat: Voltage low / shorted low

      The EMR4 reads the pressure sensor before SCR Cat (in the exhaust before the SCR catalyst) signal below its valid 0.5 to 4.5 V window.· Shorted low
      Check soon

      Causes

      • Signal wire rubbed through to ground
      • 5 V reference lost: open supply wire or a short on the shared 5 V line
      • Pressure sensor before SCR Cat failed low

      Checks

      1. 1Key on: measure the 5 V reference at the pressure sensor before SCR Cat plug; no reference means open supply wire or another sensor on that line pulling it down
      2. 2With the sensor unplugged, measure resistance from the signal pin to ground; it should not be near zero
      3. 3Unplug other sensors sharing the 5 V line one at a time to see whether the reference comes back
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Exhaust aftertreatment - Pressure sensor before SCR Cat - Voltage below normal or shorted to low source

  • EPA counter1 code

    • Deutz SPN 524096 FMI 14EPA counter: Special instructions

      The EMR4 flags the EPA counter (in the EMR4 exhaust aftertreatment inducement logic) as a special instruction case.· Other
      Info

      Causes

      • A running condition that the EMR4 monitors has been reached
      • An earlier fault left a stored special instruction
      • An open aftertreatment or DEF fault that keeps the inducement counter running
      • The counter was not reset after a repair

      Checks

      1. 1Read the full SerDia list and the freeze frame data
      2. 2Check the machine service manual for the instruction that belongs to this condition
      3. 3Read the active and stored aftertreatment faults in SerDia and note the oldest one
      4. 4Repair the original DEF or aftertreatment fault, then reset the counter with the service tool
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • NOx emission downstream SCR Cat1 code

    • Deutz SPN 524175 FMI 0NOx emission downstream SCR Cat: Reading too high· most severe

      The EMR4 sees the NOx emission downstream SCR Cat (at the SCR control outputs of the EMR4) above its allowed range.· Real condition
      Check soon

      Causes

      • Part driven beyond its limit
      • Failed part or a real condition behind the signal

      Checks

      1. 1Read the actual value against the target in SerDia
      2. 2Check the NOx emission downstream SCR Cat moves freely through its range by hand with the key off
      3. 3Inspect the supply and control wiring of the NOx emission downstream SCR Cat for chafe, water and corrosion
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Exhaust aftertreatment - NOx emission downstream SCR Cat - Data above normal operational range (Most severe level)

Shared checks

Checks, in order

  1. 1Read the catalyst temperatures and pressure in SerDia and compare them with the engine state
  2. 2Inspect the sensor connectors near the exhaust for heat damage and DEF crystals
  3. 3Check the pressure sensor line for blockage
  4. 4Measure the SCR output circuit for supply, ground and resistance

Causes

  • Temperature or pressure sensor in the hot exhaust with burnt wiring or a corroded plug
  • Pressure sensor line blocked by soot or crystallised DEF
  • SCR output wire open or shorted
  • Real catalyst or exhaust restriction

Most common here: real condition (6 of 19)

Check the real value with a separate gauge or thermometer before blaming the sensor.

When to stop

You'll notice: A warning lamp or limited function.

Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.