EF Logo

Deutz · Exhaust aftertreatment (SCR)

Deutz NOx sensors: mixing section, before and after SCR, lambda and NOx signals fault codes

The NOx sensors report NOx and oxygen (lambda) through a sensor control unit over CAN. One sits in the mixing section before the catalyst, and one after the SCR catalyst (SPN 3234, 3224).

More about these parts

The codes name the sensor and which signal failed: a timeout, an implausible value or an unknown cause on the NOx or the lambda part.

FaultCheckSPN 3224FMI 1Deutz · NOx sensor mixing section
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Read the active and stored faults with Deutz SerDia (or the machine maker's diagnostic tool) on the engine diagnostic plug.

What do these codes mean?

Deutz codes SPN 3224 FMI 1 to SPN 524085 FMI 9 are all about the nOx sensors: mixing section, before and after SCR, lambda and NOx signals. Most are lost message faults; none needs an immediate stop. Start with this check: read the NOx and lambda values of both sensors in SerDia to see which one is stale or odd.

How urgent are they?

None of the 24 codes here means stop now; all 24 can wait until the shift ends, but find the cause before the next one.

  • Check soon24

What should I check first?

Read the NOx and lambda values of both sensors in SerDia to see which one is stale or odd

Shared checks

24 of 24

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • NOx sensor mixing section3 codes

    • Deutz SPN 3224 FMI 1NOx sensor mixing section: Reading too low· most severe

      The EMR4 rates the NOx sensor mixing section (in the exhaust before the SCR catalyst) as below its allowed operating range, at the most severe level.· Real condition
      Check soon

      Causes

      • The monitored condition is really below its limit, for example a leak, a blockage or a part not working
      • Signal or part drifting low with age
      • Condition really below the limit, for example from a leak or a weak supply

      Checks

      1. 1Read the NOx sensor mixing section value in SerDia and compare it with an independent measurement before replacing parts
      2. 2Look for the real cause of a low value, such as a leak, a blocked line or a weak supply
      3. 3Compare the nOx sensor mixing section reading in SerDia with an independent measurement to see whether the low value is real.
      4. 4Compare the sensor before the catalyst with the one after it at a steady load.
      5. 5Look at the mixing section pipe for DEF deposits around the sensor boss, which can wet or foul the probe.
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Exhaust aftertreatment - NOx sensor mixing section - Data below normal operational range (Most severe level)

    • Deutz SPN 3224 FMI 2NOx sensor mixing section: Erratic reading

      The EMR4 sees the NOx sensor in the mixing section signal erratic.· Erratic or implausible
      Check soon

      Causes

      • NOx sensor failing from heat or contamination
      • Sensor connector corroded
      • Sensor heater faulty
      • Loose pin or damaged wire that makes the signal drop out

      Checks

      1. 1Compare the mixing-section NOx reading with the downstream sensor in SerDia for plausibility
      2. 2Check the exhaust for leaks near the sensor that let in fresh air and upset the reading
      3. 3Replace the NOx sensor if it fails its readiness test after the connector checks
      4. 4Wiggle the harness at the nOx sensor mixing section while watching the live value in SerDia; a jump exposes a loose pin or a chafed wire.
      5. 5Compare the sensor before the catalyst with the one after it at a steady load.
      6. 6Look at the mixing section pipe for DEF deposits around the sensor boss, which can wet or foul the probe.
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Exhaust aftertreatment - NOx sensor mixing section - Data erratic intermittent or incorrect

    • Deutz SPN 3224 FMI 9NOx sensor mixing section: Abnormal update rate timeout

      The EMR4 sees the NOx sensor mixing section (in the exhaust before the SCR catalyst) update at an abnormal rate or time out.· Lost message
      Check soon

      Causes

      • Interrupted wiring or connector to the sending unit
      • Sending unit not powered or in reset
      • Sender unpowered or its wire open

      Checks

      1. 1Check the supply and ground of the sending unit with the key on
      2. 2Inspect the connector and wiring for chafe, moisture and loose pins
      3. 3Check the supply and ground of the nOx sensor mixing section control unit and the CAN wiring to it, since a missing message is a bus or supply problem first.
      4. 4Compare the sensor before the catalyst with the one after it at a steady load.
      5. 5Look at the mixing section pipe for DEF deposits around the sensor boss, which can wet or foul the probe.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • NOx sensor after SCR3 codes

    • Deutz SPN 3234 FMI 2NOx sensor after SCR: Erratic reading

      The EMR4 sees the NOx sensor after the SCR signal erratic.· Erratic or implausible
      Check soon

      Causes

      • Sensor failing from heat or condensate
      • Sensor connector corroded
      • Exhaust leak near the sensor
      • Loose pin or damaged wire that makes the signal drop out

      Checks

      1. 1Check the sensor connector and cable for water, corrosion and chafing
      2. 2Compare the downstream NOx reading with the upstream sensor in SerDia
      3. 3Replace the NOx sensor if it fails the readiness test
      4. 4Wiggle the harness at the nOx sensor after SCR while watching the live value in SerDia; a jump exposes a loose pin or a chafed wire.
      5. 5Compare the sensor after the catalyst with the one before it at a steady load.
      6. 6Check the pipe after the catalyst for exhaust leaks upstream of the sensor, which let air dilute the reading.
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Exhaust aftertreatment - NOx sensor after SCR - Data erratic intermittent or incorrect

    • Deutz SPN 3234 FMI 9NOx sensor after SCR: Abnormal update rate timeout

      The EMR4 reports a timeout from the NOx sensor after the SCR.· Lost message
      Check soon

      Causes

      • Sensor not powered or not sending
      • CAN wiring fault
      • Sensor control module failed
      • Sender unpowered or its wire open

      Checks

      1. 1Check the CAN wires to the sensor for an open circuit or a short
      2. 2Check the sensor control module connector for water
      3. 3Replace the NOx sensor module if it stays silent with supply and CAN good
      4. 4Check the supply and ground of the nOx sensor after SCR control unit and the CAN wiring to it, since a missing message is a bus or supply problem first.
      5. 5Compare the sensor after the catalyst with the one before it at a steady load.
      6. 6Check the pipe after the catalyst for exhaust leaks upstream of the sensor, which let air dilute the reading.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 3234 FMI 11NOx sensor after SCR: Root cause not known

      The EMR4 logged a fault on the NOx sensor after SCR (in the exhaust after the SCR catalyst) but could not pin down the cause.· Other
      Check soon

      Causes

      • Intermittent wiring fault that has not stayed long enough to be classified
      • Failing part or a real condition the controller flagged
      • Intermittent contact that left no clear electrical signature

      Checks

      1. 1Read the full SerDia fault list; this code often appears next to a clearer one
      2. 2Inspect the connector and harness for chafed insulation, bent pins and moisture
      3. 3Read the freeze frame stored with the nOx sensor after SCR fault and note speed, load and battery voltage at the moment it was logged.
      4. 4Compare the sensor after the catalyst with the one before it at a steady load.
      5. 5Check the pipe after the catalyst for exhaust leaks upstream of the sensor, which let air dilute the reading.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • NOx sensor before SCR Cat5 codes

    • Deutz SPN 524070 FMI 2NOx sensor before SCR Cat: Erratic reading

      The EMR4 receives the NOx sensor before SCR Cat (sent by the NOx sensor control unit over CAN) but the content is erratic or implausible.· Erratic or implausible
      Check soon

      Causes

      • Sender sending a faulty value because of its own sensor fault
      • Electrical noise on the CAN bus
      • Loose pin or damaged wire that makes the signal drop out

      Checks

      1. 1Read the sender status and values in SerDia and compare them with a second source
      2. 2Inspect the CAN wiring for chafing and poor connectors
      3. 3Wiggle the harness at the nOx sensor before SCR Cat while watching the live value in SerDia; a jump exposes a loose pin or a chafed wire.
      4. 4Compare the sensor before the catalyst with the one after it at a steady load.
      5. 5Check the exhaust upstream of the sensor for leaks that would let air in and shift the NOx and lambda values.
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Exhaust aftertreatment - NOx sensor before SCR Cat - Data erratic intermittent or incorrect

    • Deutz SPN 524072 FMI 2NOx sensor before SCR Cat: Erratic reading

      The EMR4 receives the NOx sensor before SCR Cat (sent by the NOx sensor control unit over CAN) but the content is erratic or implausible.· Erratic or implausible
      Check soon

      Causes

      • Sender sending a faulty value because of its own sensor fault
      • Electrical noise on the CAN bus
      • Loose pin or damaged wire that makes the signal drop out

      Checks

      1. 1Read the sender status and values in SerDia and compare them with a second source
      2. 2Inspect the CAN wiring for chafing and poor connectors
      3. 3Wiggle the harness at the nOx sensor before SCR Cat while watching the live value in SerDia; a jump exposes a loose pin or a chafed wire.
      4. 4Compare the sensor before the catalyst with the one after it at a steady load.
      5. 5Check the exhaust upstream of the sensor for leaks that would let air in and shift the NOx and lambda values.
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Exhaust aftertreatment - NOx sensor before SCR Cat - Data erratic intermittent or incorrect

    • Deutz SPN 524076 FMI 2NOx sensor before SCR Cat: Erratic reading

      The EMR4 receives the NOx sensor before SCR Cat (sent by the NOx sensor control unit over CAN) but the content is erratic or implausible.· Erratic or implausible
      Check soon

      Causes

      • Sender sending a faulty value because of its own sensor fault
      • Electrical noise on the CAN bus
      • Loose pin or damaged wire that makes the signal drop out

      Checks

      1. 1Read the sender status and values in SerDia and compare them with a second source
      2. 2Inspect the CAN wiring for chafing and poor connectors
      3. 3Wiggle the harness at the nOx sensor before SCR Cat while watching the live value in SerDia; a jump exposes a loose pin or a chafed wire.
      4. 4Compare the sensor before the catalyst with the one after it at a steady load.
      5. 5Check the exhaust upstream of the sensor for leaks that would let air in and shift the NOx and lambda values.
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Exhaust aftertreatment - NOx sensor before SCR Cat - Data erratic intermittent or incorrect

    • Deutz SPN 524076 FMI 9NOx sensor before SCR Cat: Abnormal update rate timeout

      The EMR4 did not receive the NOx sensor before SCR Cat (sent by the NOx sensor control unit over CAN) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off
      • Sender unpowered or its wire open

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Check the supply and ground of the nOx sensor before SCR Cat control unit and the CAN wiring to it, since a missing message is a bus or supply problem first.
      4. 4Compare the sensor before the catalyst with the one after it at a steady load.
      5. 5Check the exhaust upstream of the sensor for leaks that would let air in and shift the NOx and lambda values.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 524077 FMI 11NOx sensor before SCR Cat: Root cause not known

      The EMR4 logged a fault on the NOx sensor before SCR Cat (sent by the NOx sensor control unit over CAN) but could not pin down the cause.· Lost message
      Check soon

      Causes

      • Intermittent wiring fault that has not stayed long enough to be classified
      • Failing part or a real condition the controller flagged
      • Intermittent contact that left no clear electrical signature

      Checks

      1. 1Read the full SerDia fault list; this code often appears next to a clearer one
      2. 2Inspect the connector and harness for chafed insulation, bent pins and moisture
      3. 3Read the freeze frame stored with the nOx sensor before SCR Cat fault and note speed, load and battery voltage at the moment it was logged.
      4. 4Compare the sensor before the catalyst with the one after it at a steady load.
      5. 5Check the exhaust upstream of the sensor for leaks that would let air in and shift the NOx and lambda values.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • NOx sensor after SCR Cat5 codes

    • Deutz SPN 524071 FMI 2NOx sensor after SCR Cat: Erratic reading

      The EMR4 receives the NOx sensor after SCR Cat (sent by the NOx sensor control unit over CAN) but the content is erratic or implausible.· Erratic or implausible
      Check soon

      Causes

      • Sender sending a faulty value because of its own sensor fault
      • Electrical noise on the CAN bus
      • Loose pin or damaged wire that makes the signal drop out

      Checks

      1. 1Read the sender status and values in SerDia and compare them with a second source
      2. 2Inspect the CAN wiring for chafing and poor connectors
      3. 3Wiggle the harness at the nOx sensor after SCR Cat while watching the live value in SerDia; a jump exposes a loose pin or a chafed wire.
      4. 4Compare the sensor after the catalyst with the one before it at a steady load.
      5. 5Check the pipe after the catalyst for exhaust leaks upstream of the sensor, which let air dilute the reading.
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Exhaust aftertreatment - NOx sensor after SCR Cat - Data erratic intermittent or incorrect

    • Deutz SPN 524073 FMI 2NOx sensor after SCR Cat: Erratic reading

      The EMR4 receives the NOx sensor after SCR Cat (sent by the NOx sensor control unit over CAN) but the content is erratic or implausible.· Erratic or implausible
      Check soon

      Causes

      • Sender sending a faulty value because of its own sensor fault
      • Electrical noise on the CAN bus
      • Loose pin or damaged wire that makes the signal drop out

      Checks

      1. 1Read the sender status and values in SerDia and compare them with a second source
      2. 2Inspect the CAN wiring for chafing and poor connectors
      3. 3Wiggle the harness at the nOx sensor after SCR Cat while watching the live value in SerDia; a jump exposes a loose pin or a chafed wire.
      4. 4Compare the sensor after the catalyst with the one before it at a steady load.
      5. 5Check the pipe after the catalyst for exhaust leaks upstream of the sensor, which let air dilute the reading.
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Exhaust aftertreatment - NOx sensor after SCR Cat - Data erratic intermittent or incorrect

    • Deutz SPN 524074 FMI 2NOx sensor after SCR Cat: Erratic reading

      The EMR4 receives the NOx sensor after SCR Cat (sent by the NOx sensor control unit over CAN) but the content is erratic or implausible.· Erratic or implausible
      Check soon

      Causes

      • Sender sending a faulty value because of its own sensor fault
      • Electrical noise on the CAN bus
      • Loose pin or damaged wire that makes the signal drop out

      Checks

      1. 1Read the sender status and values in SerDia and compare them with a second source
      2. 2Inspect the CAN wiring for chafing and poor connectors
      3. 3Wiggle the harness at the nOx sensor after SCR Cat while watching the live value in SerDia; a jump exposes a loose pin or a chafed wire.
      4. 4Compare the sensor after the catalyst with the one before it at a steady load.
      5. 5Check the pipe after the catalyst for exhaust leaks upstream of the sensor, which let air dilute the reading.
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Exhaust aftertreatment - NOx sensor after SCR Cat - Data erratic intermittent or incorrect

    • Deutz SPN 524074 FMI 9NOx sensor after SCR Cat: Abnormal update rate timeout

      The EMR4 did not receive the NOx sensor after SCR Cat (sent by the NOx sensor control unit over CAN) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off
      • Sender unpowered or its wire open

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Check the supply and ground of the nOx sensor after SCR Cat control unit and the CAN wiring to it, since a missing message is a bus or supply problem first.
      4. 4Compare the sensor after the catalyst with the one before it at a steady load.
      5. 5Check the pipe after the catalyst for exhaust leaks upstream of the sensor, which let air dilute the reading.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 524075 FMI 11NOx sensor after SCR Cat: Root cause not known

      The EMR4 logged a fault on the NOx sensor after SCR Cat (sent by the NOx sensor control unit over CAN) but could not pin down the cause.· Lost message
      Check soon

      Causes

      • Intermittent wiring fault that has not stayed long enough to be classified
      • Failing part or a real condition the controller flagged
      • Intermittent contact that left no clear electrical signature

      Checks

      1. 1Read the full SerDia fault list; this code often appears next to a clearer one
      2. 2Inspect the connector and harness for chafed insulation, bent pins and moisture
      3. 3Read the freeze frame stored with the nOx sensor after SCR Cat fault and note speed, load and battery voltage at the moment it was logged.
      4. 4Compare the sensor after the catalyst with the one before it at a steady load.
      5. 5Check the pipe after the catalyst for exhaust leaks upstream of the sensor, which let air dilute the reading.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • NOx sensor after SCR Cat lambda2 codes

    • Deutz SPN 524078 FMI 9NOx sensor after SCR Cat lambda: Abnormal update rate timeout

      The EMR4 did not receive the NOx sensor after SCR Cat lambda (part of the NOx sensor CAN message) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off
      • Sender unpowered or its wire open

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Check the supply and ground of the nOx sensor after SCR Cat lambda control unit and the CAN wiring to it, since a missing message is a bus or supply problem first.
      4. 4Read the lambda value of this sensor in SerDia; a stuck value while the NOx value moves points at the sensor element.
      5. 5Check the pipe after the catalyst for exhaust leaks upstream of the sensor, which let air dilute the reading.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 524079 FMI 9NOx sensor after SCR Cat lambda: Abnormal update rate timeout

      The EMR4 did not receive the NOx sensor after SCR Cat lambda (part of the NOx sensor CAN message) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off
      • Sender unpowered or its wire open

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Check the supply and ground of the nOx sensor after SCR Cat lambda control unit and the CAN wiring to it, since a missing message is a bus or supply problem first.
      4. 4Read the lambda value of this sensor in SerDia; a stuck value while the NOx value moves points at the sensor element.
      5. 5Check the pipe after the catalyst for exhaust leaks upstream of the sensor, which let air dilute the reading.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • NOx sensor before SCR Cat lambda2 codes

    • Deutz SPN 524080 FMI 9NOx sensor before SCR Cat lambda: Abnormal update rate timeout

      The EMR4 did not receive the NOx sensor before SCR Cat lambda (part of the NOx sensor CAN message) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off
      • Sender unpowered or its wire open

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Check the supply and ground of the nOx sensor before SCR Cat lambda control unit and the CAN wiring to it, since a missing message is a bus or supply problem first.
      4. 4Read the lambda value of this sensor in SerDia; a stuck value while the NOx value moves points at the sensor element.
      5. 5Check the exhaust upstream of the sensor for leaks that would let air in and shift the NOx and lambda values.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 524081 FMI 9NOx sensor before SCR Cat lambda: Abnormal update rate timeout

      The EMR4 did not receive the NOx sensor before SCR Cat lambda (part of the NOx sensor CAN message) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off
      • Sender unpowered or its wire open

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Check the supply and ground of the nOx sensor before SCR Cat lambda control unit and the CAN wiring to it, since a missing message is a bus or supply problem first.
      4. 4Read the lambda value of this sensor in SerDia; a stuck value while the NOx value moves points at the sensor element.
      5. 5Check the exhaust upstream of the sensor for leaks that would let air in and shift the NOx and lambda values.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • NOx sensor after SCR Cat NOx2 codes

    • Deutz SPN 524082 FMI 9NOx sensor after SCR Cat NOx: Abnormal update rate timeout

      The EMR4 did not receive the NOx sensor after SCR Cat NOx (part of the NOx sensor CAN message) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off
      • Sender unpowered or its wire open

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Check the supply and ground of the nOx sensor after SCR Cat NOx control unit and the CAN wiring to it, since a missing message is a bus or supply problem first.
      4. 4Read the NOx value of this sensor in SerDia; a stuck value while the lambda value moves points at the sensor element.
      5. 5Check the pipe after the catalyst for exhaust leaks upstream of the sensor, which let air dilute the reading.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 524083 FMI 9NOx sensor after SCR Cat NOx: Abnormal update rate timeout

      The EMR4 did not receive the NOx sensor after SCR Cat NOx (part of the NOx sensor CAN message) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off
      • Sender unpowered or its wire open

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Check the supply and ground of the nOx sensor after SCR Cat NOx control unit and the CAN wiring to it, since a missing message is a bus or supply problem first.
      4. 4Read the NOx value of this sensor in SerDia; a stuck value while the lambda value moves points at the sensor element.
      5. 5Check the pipe after the catalyst for exhaust leaks upstream of the sensor, which let air dilute the reading.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • NOx sensor before SCR Cat NOx2 codes

    • Deutz SPN 524084 FMI 9NOx sensor before SCR Cat NOx: Abnormal update rate timeout

      The EMR4 did not receive the NOx sensor before SCR Cat NOx (part of the NOx sensor CAN message) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off
      • Sender unpowered or its wire open

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Check the supply and ground of the nOx sensor before SCR Cat NOx control unit and the CAN wiring to it, since a missing message is a bus or supply problem first.
      4. 4Read the NOx value of this sensor in SerDia; a stuck value while the lambda value moves points at the sensor element.
      5. 5Check the exhaust upstream of the sensor for leaks that would let air in and shift the NOx and lambda values.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 524085 FMI 9NOx sensor before SCR Cat NOx: Abnormal update rate timeout

      The EMR4 did not receive the NOx sensor before SCR Cat NOx (part of the NOx sensor CAN message) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off
      • Sender unpowered or its wire open

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Check the supply and ground of the nOx sensor before SCR Cat NOx control unit and the CAN wiring to it, since a missing message is a bus or supply problem first.
      4. 4Read the NOx value of this sensor in SerDia; a stuck value while the lambda value moves points at the sensor element.
      5. 5Check the exhaust upstream of the sensor for leaks that would let air in and shift the NOx and lambda values.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

Shared checks

Checks, in order

  1. 1Read the NOx and lambda values of both sensors in SerDia to see which one is stale or odd
  2. 2Check the supply fuse and ground of the sensor control unit with the key on
  3. 3Check for an SCR efficiency code, since a failing catalyst gives a genuine high NOx reading
  4. 4Inspect the sensor plugs for water and DEF deposits and wiggle the harness while watching the status
  5. 5Fit a known good sensor only if the wiring and supply are proven good

Causes

  • NOx sensor control unit without supply, so it stops sending
  • Sensor element worn out, contaminated or wetted by DEF spray
  • CAN wire to the sensor control unit chafed or its plug corroded
  • A real high NOx level because the catalyst is not converting

Most codes here: lost message (14 of 24)

Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

When to stop

You'll notice: A warning lamp or limited function.

Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.