EF Logo

Deutz · Exhaust aftertreatment (SCR)

Deutz DEF temperature sensing and DEF quality fault codes

The DEF temperature sensors (in the tank unit, the quality sensor and the dosing module) that tell the EMR4 whether DEF is frozen or hot, and the DEF quality sensor that checks the urea concentration. Each code names the sensor and how its reading failed.

FaultCheckSPN 3031FMI 0Deutz · DEF tank temperature
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Read the active and stored faults with Deutz SerDia (or the machine maker's diagnostic tool) on the engine diagnostic plug.

What do these codes mean?

Deutz codes SPN 3031 FMI 0 to SPN 523980 FMI 14 are all about the dEF temperature sensing and DEF quality. The most common failure type is erratic or implausible (6 of 23); none needs an immediate stop. Start with this check: compare the DEF tank temperature in SerDia with ambient temperature on a cold engine.

How urgent are they?

None of the 23 codes here means stop now; 22 can wait until the shift ends, but find the cause before the next one; 1 is information only.

  • Check soon22
  • Info1

What should I check first?

Compare the DEF tank temperature in SerDia with ambient temperature on a cold engine

Shared checks

23 of 23

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • DEF tank temperature8 codes

    • Deutz SPN 3031 FMI 0DEF tank temperature: Reading too high· most severe

      The DEF tank temperature (in the DEF (AdBlue) tank) reports a temperature above the allowed operating range.· Real condition
      Check soon

      Causes

      • DEF genuinely too warm: check the tank heater valve or coolant supply to the tank heater
      • Partial short or wet connector lowering the DEF tank temperature resistance so it reads hot
      • Sensor drifting low in resistance with age

      Checks

      1. 1Check the real temperature with an infrared thermometer or mechanical gauge before touching the DEF tank temperature
      2. 2Look in SerDia at the DEF tank temperature reading next to a neighbouring temperature; a lone hot value points at the sensor
      3. 3Check the connector pins for moisture and corrosion, which can pull a reading hot
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Exhaust aftertreatment - DEF tank temperature - Data above normal operational range (Most severe level)

    • Deutz SPN 3031 FMI 1DEF tank temperature: Reading too low· most severe

      The DEF tank temperature (in the DEF (AdBlue) tank) reports a temperature below the allowed range.· Real condition
      Check soon

      Causes

      • DEF very cold: frozen DEF is a real condition in cold climates and the heater must thaw it
      • High resistance in the DEF tank temperature connector or a corroded pin making it read cold
      • Sensor drifting high in resistance after heat cycles

      Checks

      1. 1Measure the real temperature with a second thermometer once the engine has warmed up
      2. 2Compare the DEF tank temperature value in SerDia with a neighbouring temperature; if only this one is cold the circuit is suspect
      3. 3Measure voltage drop across the connector with the engine running to find a high-resistance joint
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Exhaust aftertreatment - DEF tank temperature - Data below normal operational range (Most severe level)

    • Deutz SPN 4365 FMI 0DEF tank temperature: Reading too high· most severe

      The DEF tank temperature sensor (in the DEF (AdBlue) tank unit) reports a temperature above the allowed operating range.· Real condition
      Check soon

      Causes

      • Partial short or wet connector lowering the DEF tank temperature sensor resistance so it reads hot
      • Sensor drifting low in resistance with age
      • Sensor part of the DEF tank unit failed

      Checks

      1. 1Look in SerDia at the DEF tank temperature sensor reading next to a neighbouring temperature; a lone hot value points at the sensor
      2. 2Check the real temperature with an infrared thermometer or mechanical gauge before touching the DEF tank temperature sensor
      3. 3Check the connector pins for moisture and corrosion, which can pull a reading hot
      4. 4Inspect the tank unit connector for urea crystals and moisture
      5. 5Compare DEF tank temperature with ambient at cold start; they should be close
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Exhaust aftertreatment - DEF tank temperature - Data above normal operational range (Most severe level)

    • Deutz SPN 4365 FMI 2DEF tank temperature: Erratic reading

      The EMR4 sees the DEF tank temperature sensor (in the DEF (AdBlue) tank unit) jump around or disagree with other temperatures.· Erratic or implausible
      Check soon

      Causes

      • Intermittent contact in the connector or a pin with fretting
      • Harness chafed in a spot that makes contact only under vibration
      • Sensor element on its way out in the DEF tank temperature sensor

      Checks

      1. 1Watch the DEF tank temperature sensor value in SerDia while wiggling the harness and connector, and note when it jumps
      2. 2Inspect the connector for loose pins, bent terminals and moisture
      3. 3Check the harness along its route for chafe, especially where it crosses a bracket
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Exhaust aftertreatment - DEF tank temperature - Data erratic intermittent or incorrect

    • Deutz SPN 4365 FMI 3DEF tank temperature: Voltage high / shorted high

      The EMR4 reads the DEF tank temperature sensor (in the DEF (AdBlue) tank unit) at a voltage above its valid window.· Shorted high
      Check soon

      Causes

      • Sensor element failed open, so its resistance stays very high at any temperature
      • Open circuit: broken wire, pushed-out pin or an unplugged connector at the DEF tank temperature sensor
      • Tank unit connector wet or corroded

      Checks

      1. 1Bridge the two harness pins with a jumper wire with the key on; the code should change to the voltage-below-normal one if the harness is sound
      2. 2Compare DEF tank temperature with ambient at cold start; they should be close
      3. 3Inspect the tank unit connector for urea crystals and moisture
      4. 4With the sensor unplugged and key on, check the signal pin for battery voltage, which would mean a short to supply
      5. 5Unplug the DEF tank temperature sensor and measure its resistance across the two pins; an NTC that reads open at room temperature is finished
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Exhaust aftertreatment - DEF tank temperature - Voltage above normal or shorted to high source

    • Deutz SPN 4365 FMI 4DEF tank temperature: Voltage low / shorted low

      The EMR4 reads the DEF tank temperature sensor (in the DEF (AdBlue) tank unit) at a voltage below its valid window.· Shorted low
      Check soon

      Causes

      • Water bridging the pins inside the DEF tank temperature sensor connector
      • Signal wire rubbed through to the engine block or frame
      • Sensor element shorted internally, so it reads as extremely hot

      Checks

      1. 1Unplug the DEF tank temperature sensor with the key on: if the code flips to the voltage-above-normal one, the harness is fine and the sensor is the shorted part
      2. 2Compare DEF tank temperature with ambient at cold start; they should be close
      3. 3Inspect the tank unit connector for urea crystals and moisture
      4. 4Measure the DEF tank temperature sensor resistance and compare it with its temperature; a very low value means the element is shorted
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Exhaust aftertreatment - DEF tank temperature - Voltage below normal or shorted to low source

    • Deutz SPN 4365 FMI 12DEF tank temperature: Bad device or component

      The EMR4 judges the DEF tank temperature sensor (in the DEF (AdBlue) tank unit) to be a bad device.· Part or controller
      Check soon

      Causes

      • Internal failure of the part or its electronics
      • Water, soot or dirt inside the part

      Checks

      1. 1Read the DEF tank temperature sensor status in SerDia and run any available actuator or component test
      2. 2Check supply voltage and ground at the connector with the key on to confirm it is powered
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Exhaust aftertreatment - DEF tank temperature - Bad intelligent device or component

    • Deutz SPN 4365 FMI 13DEF tank temperature: Out of calibration

      The EMR4 reports the DEF tank temperature sensor (in the DEF (AdBlue) tank unit) as out of calibration.· Part or controller
      Check soon

      Causes

      • Part replaced without a calibration or learning routine
      • Mechanical wear or play shifting the learned positions

      Checks

      1. 1Run the matching calibration or learn routine with the service tool, if available
      2. 2Check the part for mechanical play or a loose mounting that shifts its readings
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • DEF tank temperature (DEF quality sensor)4 codes

    • Deutz SPN 3519 FMI 3DEF tank temperature (DEF quality sensor): Voltage high / shorted high

      The EMR4 reads the DEF tank temperature (DEF quality sensor) (in the DEF (AdBlue) tank unit) at a voltage above its valid window.· Shorted high
      Check soon

      Causes

      • Open circuit: broken wire, pushed-out pin or an unplugged connector at the DEF tank temperature (DEF quality sensor)
      • Sensor element failed open, so its resistance stays very high at any temperature
      • Signal wire touching a supply voltage somewhere in the harness

      Checks

      1. 1Unplug the DEF tank temperature (DEF quality sensor) and measure its resistance across the two pins; an NTC that reads open at room temperature is finished
      2. 2Bridge the two harness pins with a jumper wire with the key on; the code should change to the voltage-below-normal one if the harness is sound
      3. 3With the sensor unplugged and key on, check the signal pin for battery voltage, which would mean a short to supply
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Exhaust aftertreatment - DEF tank temperature (DEF quality sensor) - Voltage above normal or shorted to high source

    • Deutz SPN 3519 FMI 4DEF tank temperature (DEF quality sensor): Voltage low / shorted low

      The EMR4 reads the DEF tank temperature (DEF quality sensor) (in the DEF (AdBlue) tank unit) at a voltage below its valid window.· Shorted low
      Check soon

      Causes

      • Signal wire rubbed through to the engine block or frame
      • Sensor element shorted internally, so it reads as extremely hot
      • Water bridging the pins inside the DEF tank temperature (DEF quality sensor) connector

      Checks

      1. 1Unplug the DEF tank temperature (DEF quality sensor) with the key on: if the code flips to the voltage-above-normal one, the harness is fine and the sensor is the shorted part
      2. 2With the EMR4 unplugged, measure resistance from the signal pin to ground; anything but open points to a short in the wire
      3. 3Measure the DEF tank temperature (DEF quality sensor) resistance and compare it with its temperature; a very low value means the element is shorted
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Exhaust aftertreatment - DEF tank temperature (DEF quality sensor) - Voltage below normal or shorted to low source

    • Deutz SPN 3519 FMI 12DEF tank temperature (DEF quality sensor): Bad device or component

      The EMR4 judges the DEF tank temperature (DEF quality sensor) (in the DEF (AdBlue) tank unit) to be a bad device.· Part or controller
      Check soon

      Causes

      • Internal failure of the part or its electronics
      • Water, soot or dirt inside the part

      Checks

      1. 1Read the DEF tank temperature (DEF quality sensor) status in SerDia and run any available actuator or component test
      2. 2Check supply voltage and ground at the connector with the key on to confirm it is powered
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Exhaust aftertreatment - DEF tank temperature (DEF quality sensor) - Bad intelligent device or component

    • Deutz SPN 3519 FMI 13DEF tank temperature (DEF quality sensor): Out of calibration

      The EMR4 reports the DEF tank temperature (DEF quality sensor) (in the DEF (AdBlue) tank unit) as out of calibration.· Part or controller
      Check soon

      Causes

      • Part replaced without a calibration or learning routine
      • Mechanical wear or play shifting the learned positions

      Checks

      1. 1Run the matching calibration or learn routine with the service tool, if available
      2. 2Check the part for mechanical play or a loose mounting that shifts its readings
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • DEF quality sensor6 codes

    • Deutz SPN 3520 FMI 1DEF quality sensor: Reading too low· most severe

      The EMR4 rates the DEF quality sensor (in the DEF tank or suction unit) as below its allowed operating range, at the most severe level.· Real condition
      Check soon

      Causes

      • The monitored condition is really below its limit, for example a leak, a blockage or a part not working
      • Signal or part drifting low with age

      Checks

      1. 1Read the DEF quality sensor value in SerDia and compare it with an independent measurement before replacing parts
      2. 2Look for the real cause of a low value, such as a leak, a blocked line or a weak supply
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Exhaust aftertreatment - DEF quality sensor - Data below normal operational range (Most severe level)

    • Deutz SPN 3520 FMI 2DEF quality sensor: Erratic reading

      The EMR4 sees the DEF quality sensor (in the DEF tank or suction unit) erratic, intermittent or implausible.· Erratic or implausible
      Check soon

      Causes

      • Intermittent contact in a connector or a pin with fretting
      • Harness chafed where it moves with vibration

      Checks

      1. 1Watch the DEF quality sensor value in SerDia while wiggling the harness and connector and note when it jumps
      2. 2Compare it with a related value, since a lone odd reading points at the circuit or part itself
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Exhaust aftertreatment - DEF quality sensor - Data erratic intermittent or incorrect

    • Deutz SPN 3520 FMI 3DEF quality sensor: Voltage high / shorted high

      The EMR4 sees the voltage of the DEF quality sensor (in the DEF tank or suction unit) above normal, or a short to a high source.· Shorted high
      Check soon

      Causes

      • Signal wire shorted to battery positive or a supply line
      • Open ground or part failed in a way that pulls the signal high

      Checks

      1. 1Unplug the part with the key on and see whether the code changes to the low or open one
      2. 2With the EMR4 unplugged, measure the wire against battery positive; it should be open
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Exhaust aftertreatment - DEF quality sensor - Voltage above normal or shorted to high source

    • Deutz SPN 3520 FMI 4DEF quality sensor: Voltage low / shorted low

      The EMR4 sees the voltage of the DEF quality sensor (in the DEF tank or suction unit) below normal, or a short to a low source.· Shorted low
      Check soon

      Causes

      • Signal wire chafed to ground or the engine block
      • Part shorted internally or water in the connector

      Checks

      1. 1Unplug the part with the key on and see whether the code changes to the high or open one
      2. 2With the EMR4 unplugged, measure the wire to ground; anything near zero ohms means a short
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Exhaust aftertreatment - DEF quality sensor - Voltage below normal or shorted to low source

    • Deutz SPN 3520 FMI 8DEF quality sensor: Abnormal frequency / pulse width

      The EMR4 sees an abnormal frequency or pulse width on the DEF quality sensor (in the DEF tank or suction unit).· Erratic or implausible
      Check soon

      Causes

      • Electrical noise or a loose connection distorting the signal
      • Sensor or sending unit failing

      Checks

      1. 1Watch the DEF quality sensor value in SerDia for jumps and dropouts
      2. 2Inspect the connector and harness for chafe, moisture and loose pins
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Exhaust aftertreatment - DEF quality sensor - Abnormal frequency or pulse width or period

    • Deutz SPN 3520 FMI 13DEF quality sensor: Out of calibration

      The EMR4 reports the DEF quality sensor (in the DEF tank or suction unit) as out of calibration.· Part or controller
      Check soon

      Causes

      • Part replaced without a calibration or learning routine
      • Mechanical wear or play shifting the learned positions

      Checks

      1. 1Run the matching calibration or learn routine with the service tool, if available
      2. 2Check the part for mechanical play or a loose mounting that shifts its readings
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • DEF temperature4 codes

    • Deutz SPN 523721 FMI 2DEF temperature: Erratic reading

      The EMR4 sees the DEF temperature (in the DEF (AdBlue) tank unit) jump around or disagree with other temperatures.· Erratic or implausible
      Check soon

      Causes

      • Intermittent contact in the connector or a pin with fretting
      • Harness chafed in a spot that makes contact only under vibration
      • Sensor element on its way out in the DEF temperature

      Checks

      1. 1Watch the DEF temperature value in SerDia while wiggling the harness and connector, and note when it jumps
      2. 2Inspect the connector for loose pins, bent terminals and moisture
      3. 3Check the harness along its route for chafe, especially where it crosses a bracket
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Exhaust aftertreatment - DEF temperature - Data erratic intermittent or incorrect

    • Deutz SPN 523721 FMI 8DEF temperature: Abnormal frequency / pulse width

      The EMR4 sees an abnormal frequency or pulse width on the DEF temperature (in the DEF (AdBlue) tank unit).· Erratic or implausible
      Check soon

      Causes

      • Electrical noise or a loose connection distorting the signal
      • Sensor or sending unit failing

      Checks

      1. 1Watch the DEF temperature value in SerDia for jumps and dropouts
      2. 2Inspect the connector and harness for chafe, moisture and loose pins
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Exhaust aftertreatment - DEF temperature - Abnormal frequency or pulse width or period

    • Deutz SPN 523721 FMI 11DEF temperature: Root cause not known

      The EMR4 logged a fault on the DEF temperature (in the DEF (AdBlue) tank unit) but could not pin down the cause.· Other
      Check soon

      Causes

      • Intermittent wiring fault that has not stayed long enough to be classified
      • Failing DEF temperature element
      • Poor ground or supply at the sensor

      Checks

      1. 1Read the full SerDia fault list; this code often appears next to a clearer one on the DEF temperature
      2. 2Measure the DEF temperature resistance and compare with a temperature table
      3. 3Inspect the DEF temperature connector and the harness run for chafed insulation, bent pins and moisture
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • Deutz SPN 523722 FMI 8DEF temperature: Abnormal frequency / pulse width

      The EMR4 sees an abnormal frequency or pulse width on the DEF temperature (in the DEF (AdBlue) tank unit).· Erratic or implausible
      Check soon

      Causes

      • Electrical noise or a loose connection distorting the signal
      • Sensor or sending unit failing

      Checks

      1. 1Watch the DEF temperature value in SerDia for jumps and dropouts
      2. 2Inspect the connector and harness for chafe, moisture and loose pins
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Exhaust aftertreatment - DEF temperature - Abnormal frequency or pulse width or period

  • DEF concentration1 code

    • Deutz SPN 523980 FMI 14DEF concentration: Special instructions

      The EMR4 flags the DEF concentration (in the DEF tank or suction unit) as a special instruction case.· Other
      Info

      Causes

      • A running condition that the EMR4 monitors has been reached
      • An earlier fault left a stored special instruction

      Checks

      1. 1Read the full SerDia list and the freeze frame data
      2. 2Check the machine service manual for the instruction that belongs to this condition
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

Shared checks

Checks, in order

  1. 1Compare the DEF tank temperature in SerDia with ambient temperature on a cold engine
  2. 2Check the DEF in the tank for dilution or contamination before replacing the quality sensor
  3. 3Inspect the tank unit connector for DEF and corrosion
  4. 4Compare the reading with the DEF temperature from the dosing module

Causes

  • Temperature or quality sensor in the tank unit failed or its wiring faulty
  • DEF really frozen, overheated or diluted with water or the wrong fluid
  • Connector corroded by DEF
  • Tank heater valve stuck, giving a temperature that does not match the command

Most common here: erratic or implausible (6 of 23)

Watch the live value on the service tool while you flex the harness and tap the connector.

When to stop

You'll notice: A warning lamp or limited function.

Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request