The heaters that thaw frozen DEF: the heated DEF lines, the tank heating valve and heater, and the SCR module heating circuit. Each code names the heater circuit and whether it is shorted high, shorted low, open or faulty.

FaultCheckSPN 4243FMI 11Deutz · SCR heater
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Read the active and stored faults with Deutz SerDia (or the machine maker's diagnostic tool) on the engine diagnostic plug.

What do these codes mean?

Deutz codes SPN 4243 FMI 11 to SPN 524063 FMI 12 are all about the dEF line, tank and SCR heaters. The most common failure type is shorted high (6 of 23); none needs an immediate stop. Start with this check: measure the heater or valve coil resistance for the part named in the code.

How urgent are they?

None of the 23 codes here means stop now; all 23 can wait until the shift ends, but find the cause before the next one.

  • Check soon23

What should I check first?

Measure the heater or valve coil resistance for the part named in the code

Shared checks

23 of 23

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • SCR heater4 codes

    • Deutz SPN 4243 FMI 11SCR heater: Root cause not known

      The EMR4 logged a fault on the SCR heater (in the SCR dosing module heating circuit) but could not classify the cause.· Lost message
      Check soon

      Causes

      • Intermittent wiring fault
      • Failing SCR heater
      • Intermittent contact that left no clear electrical signature

      Checks

      1. 1Read the full SerDia fault list; this code often sits next to a clearer one on the SCR heater
      2. 2Measure the supply and ground at the SCR heater plug with the key on to confirm it is powered
      3. 3Inspect the SCR heater plug and harness for chafed insulation, bent pins and moisture
      4. 4Read the freeze frame stored with the SCR heater fault and note speed, load and battery voltage at the moment it was logged.
      5. 5Measure the resistance of the SCR heater at its connector.
      6. 6Check the SCR heater fuse and its relay before testing the heater element.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 523719 FMI 3SCR heater: Voltage high / shorted high

      The EMR4 sees the output for the SCR heater (in the SCR dosing module heating circuit) at a voltage above normal, as if the circuit is shorted to the battery supply.· Shorted high
      Check soon

      Causes

      • Output wire shorted to battery positive
      • Connector pin touching a live pin
      • SCR heater shorted internally
      • Harness insulation worn through where it rubs on a bracket, letting the wire touch a live supply

      Checks

      1. 1Unplug the SCR heater: if the code stays, the short is in the harness or the EMR4; if it clears, the part is the shorted one
      2. 2With the EMR4 unplugged, measure the output wire to battery positive; it should be open
      3. 3Measure the winding or coil resistance of the part
      4. 4With the EMR4 and the SCR heater unplugged, measure the signal wire against battery positive; it must read open, and any reading means the harness is shorted high.
      5. 5Measure the resistance of the SCR heater at its connector.
      6. 6Check the SCR heater fuse and its relay before testing the heater element.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Exhaust aftertreatment - SCR heater - Voltage above normal or shorted to high source

    • Deutz SPN 523719 FMI 4SCR heater: Voltage low / shorted low

      The EMR4 sees the output for the SCR heater (in the SCR dosing module heating circuit) at a voltage below normal, as if the circuit is shorted to ground.· Shorted low
      Check soon

      Causes

      • Output wire chafed to ground or the engine block
      • SCR heater winding shorted to its housing
      • Water in the connector bridging the pins
      • Wire pinched against the engine block or frame so the signal is pulled to ground

      Checks

      1. 1Unplug the SCR heater: if the code changes, the part is the shorted one; if it stays, look at the harness
      2. 2With the EMR4 unplugged, measure the output wire to ground; it should not be low ohms
      3. 3Measure the winding resistance of the part and look for a very low value
      4. 4With the connector unplugged, measure the SCR heater signal wire against ground; a low resistance means a harness short, while an open reading sends you to the part itself.
      5. 5Measure the resistance of the SCR heater at its connector.
      6. 6Check the SCR heater fuse and its relay before testing the heater element.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Exhaust aftertreatment - SCR heater - Voltage below normal or shorted to low source

    • Deutz SPN 523719 FMI 5SCR heater: Current low / open circuit

      The EMR4 sees too little current through the SCR heater (in the SCR dosing module heating circuit), which means the circuit is open.· Open circuit
      Check soon

      Causes

      • Broken wire or a pin pushed out of the connector
      • SCR heater winding open
      • Connector left unplugged after earlier work
      • Terminal pushed back or corroded in its connector so the circuit is open

      Checks

      1. 1Measure the resistance across the SCR heater terminals: infinity means an open winding
      2. 2Continuity-test each wire to the matching EMR4 pin
      3. 3Inspect both ends of the SCR heater circuit (EMR4 plug and part connector) for pins pushed back in the housing
      4. 4Check the continuity of both wires between the EMR4 plug and the SCR heater connector, then the coil resistance, to separate a broken wire from a dead coil.
      5. 5Measure the resistance of the SCR heater at its connector.
      6. 6Check the SCR heater fuse and its relay before testing the heater element.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

      Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

      Source wording:Exhaust aftertreatment - SCR heater - Current below normal or open circuit

  • DEF suction line heater relay3 codes

    • Deutz SPN 4341 FMI 3DEF suction line heater relay: Voltage high / shorted high

      The EMR4 sees the output for the DEF suction line heater relay (in the DEF suction line heater circuit) at a voltage above normal, as if the circuit is shorted to the battery supply.· Shorted high
      Check soon

      Causes

      • Output wire shorted to battery positive
      • Connector pin touching a live pin
      • DEF suction line heater relay shorted internally
      • Harness insulation worn through where it rubs on a bracket, letting the wire touch a live supply

      Checks

      1. 1Unplug the DEF suction line heater relay: if the code stays, the short is in the harness or the EMR4; if it clears, the part is the shorted one
      2. 2With the EMR4 unplugged, measure the output wire to battery positive; it should be open
      3. 3Measure the winding or coil resistance of the part
      4. 4With the EMR4 and the DEF suction line heater relay unplugged, measure the signal wire against battery positive; it must read open, and any reading means the harness is shorted high.
      5. 5Check the relay of the suction line heater and its fuse.
      6. 6Measure the voltage at the suction line heater relay output while heating is commanded in cold conditions.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Exhaust aftertreatment - DEF suction line heater relay - Voltage above normal or shorted to high source

    • Deutz SPN 4341 FMI 4DEF suction line heater relay: Voltage low / shorted low

      The EMR4 sees the output for the DEF suction line heater relay (in the DEF suction line heater circuit) at a voltage below normal, as if the circuit is shorted to ground.· Shorted low
      Check soon

      Causes

      • Output wire chafed to ground or the engine block
      • DEF suction line heater relay winding shorted to its housing
      • Water in the connector bridging the pins
      • Wire pinched against the engine block or frame so the signal is pulled to ground

      Checks

      1. 1Unplug the DEF suction line heater relay: if the code changes, the part is the shorted one; if it stays, look at the harness
      2. 2With the EMR4 unplugged, measure the output wire to ground; it should not be low ohms
      3. 3Measure the winding resistance of the part and look for a very low value
      4. 4With the connector unplugged, measure the DEF suction line heater relay signal wire against ground; a low resistance means a harness short, while an open reading sends you to the part itself.
      5. 5Check the relay of the suction line heater and its fuse.
      6. 6Measure the voltage at the suction line heater relay output while heating is commanded in cold conditions.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Exhaust aftertreatment - DEF suction line heater relay - Voltage below normal or shorted to low source

    • Deutz SPN 4341 FMI 5DEF suction line heater relay: Current low / open circuit

      The EMR4 sees too little current through the DEF suction line heater relay (in the DEF suction line heater circuit), which means the circuit is open.· Open circuit
      Check soon

      Causes

      • Broken wire or a pin pushed out of the connector
      • DEF suction line heater relay winding open
      • Connector left unplugged after earlier work
      • Terminal pushed back or corroded in its connector so the circuit is open

      Checks

      1. 1Measure the resistance across the DEF suction line heater relay terminals: infinity means an open winding
      2. 2Continuity-test each wire to the matching EMR4 pin
      3. 3Inspect both ends of the DEF suction line heater relay circuit (EMR4 plug and part connector) for pins pushed back in the housing
      4. 4Check the continuity of both wires between the EMR4 plug and the DEF suction line heater relay connector, then the coil resistance, to separate a broken wire from a dead coil.
      5. 5Check the relay of the suction line heater and its fuse.
      6. 6Measure the voltage at the suction line heater relay output while heating is commanded in cold conditions.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

      Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

      Source wording:Exhaust aftertreatment - DEF suction line heater relay - Current below normal or open circuit

  • Heater DEF pressure line4 codes

    • Deutz SPN 4343 FMI 3Heater DEF pressure line: Voltage high / shorted high

      The EMR4 sees the output for the DEF pressure line heater (on the DEF pressure line between pump and dosing valve) at a voltage above normal, as if the circuit is shorted to the battery supply.· Shorted high
      Check soon

      Causes

      • Output wire shorted to battery positive
      • Connector pin touching a live pin
      • DEF pressure line heater shorted internally
      • Harness insulation worn through where it rubs on a bracket, letting the wire touch a live supply

      Checks

      1. 1Unplug the DEF pressure line heater: if the code stays, the short is in the harness or the EMR4; if it clears, the part is the shorted one
      2. 2With the EMR4 unplugged, measure the output wire to battery positive; it should be open
      3. 3Measure the winding or coil resistance of the part
      4. 4With the EMR4 and the heater DEF pressure line unplugged, measure the signal wire against battery positive; it must read open, and any reading means the harness is shorted high.
      5. 5Trace the heater wire along the pressure line for damage.
      6. 6Measure the current of the pressure line heater when it is switched on and compare it with the return line heater.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Exhaust aftertreatment - Heater DEF pressure line - Voltage above normal or shorted to high source

    • Deutz SPN 4343 FMI 4Heater DEF pressure line: Voltage low / shorted low

      The EMR4 sees the output for the DEF pressure line heater (on the DEF pressure line between pump and dosing valve) at a voltage below normal, as if the circuit is shorted to ground.· Shorted low
      Check soon

      Causes

      • Output wire chafed to ground or the engine block
      • DEF pressure line heater winding shorted to its housing
      • Water in the connector bridging the pins
      • Wire pinched against the engine block or frame so the signal is pulled to ground

      Checks

      1. 1Unplug the DEF pressure line heater: if the code changes, the part is the shorted one; if it stays, look at the harness
      2. 2With the EMR4 unplugged, measure the output wire to ground; it should not be low ohms
      3. 3Measure the winding resistance of the part and look for a very low value
      4. 4With the connector unplugged, measure the heater DEF pressure line signal wire against ground; a low resistance means a harness short, while an open reading sends you to the part itself.
      5. 5Trace the heater wire along the pressure line for damage.
      6. 6Measure the current of the pressure line heater when it is switched on and compare it with the return line heater.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Exhaust aftertreatment - Heater DEF pressure line - Voltage below normal or shorted to low source

    • Deutz SPN 4343 FMI 5Heater DEF pressure line: Current low / open circuit

      The EMR4 sees too little current through the DEF pressure line heater (on the DEF pressure line between pump and dosing valve), which means the circuit is open.· Open circuit
      Check soon

      Causes

      • Broken wire or a pin pushed out of the connector
      • DEF pressure line heater winding open
      • Connector left unplugged after earlier work
      • Terminal pushed back or corroded in its connector so the circuit is open

      Checks

      1. 1Measure the resistance across the DEF pressure line heater terminals: infinity means an open winding
      2. 2Continuity-test each wire to the matching EMR4 pin
      3. 3Inspect both ends of the DEF pressure line heater circuit (EMR4 plug and part connector) for pins pushed back in the housing
      4. 4Check the continuity of both wires between the EMR4 plug and the heater DEF pressure line connector, then the coil resistance, to separate a broken wire from a dead coil.
      5. 5Trace the heater wire along the pressure line for damage.
      6. 6Measure the current of the pressure line heater when it is switched on and compare it with the return line heater.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

      Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

      Source wording:Exhaust aftertreatment - Heater DEF pressure line - Current below normal or open circuit

    • Deutz SPN 4343 FMI 11Heater DEF pressure line: Root cause not known

      The EMR4 logged a fault on the DEF pressure line heater (on the DEF pressure line between pump and dosing valve) but could not classify the cause.· Other
      Check soon

      Causes

      • Intermittent wiring fault
      • Failing DEF pressure line heater
      • Intermittent contact that left no clear electrical signature

      Checks

      1. 1Read the full SerDia fault list; this code often sits next to a clearer one on the DEF pressure line heater
      2. 2Measure the supply and ground at the DEF pressure line heater plug with the key on to confirm it is powered
      3. 3Inspect the DEF pressure line heater plug and harness for chafed insulation, bent pins and moisture
      4. 4Read the freeze frame stored with the heater DEF pressure line fault and note speed, load and battery voltage at the moment it was logged.
      5. 5Trace the heater wire along the pressure line for damage.
      6. 6Measure the current of the pressure line heater when it is switched on and compare it with the return line heater.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Heater DEF return line4 codes

    • Deutz SPN 4345 FMI 3Heater DEF return line: Voltage high / shorted high

      The EMR4 sees the output for the DEF return line heater (on the DEF return line from the dosing module to the tank) at a voltage above normal, as if the circuit is shorted to the battery supply.· Shorted high
      Check soon

      Causes

      • Output wire shorted to battery positive
      • Connector pin touching a live pin
      • DEF return line heater shorted internally
      • Harness insulation worn through where it rubs on a bracket, letting the wire touch a live supply

      Checks

      1. 1Unplug the DEF return line heater: if the code stays, the short is in the harness or the EMR4; if it clears, the part is the shorted one
      2. 2With the EMR4 unplugged, measure the output wire to battery positive; it should be open
      3. 3Measure the winding or coil resistance of the part
      4. 4With the EMR4 and the heater DEF return line unplugged, measure the signal wire against battery positive; it must read open, and any reading means the harness is shorted high.
      5. 5Trace the heater wire along the return line for damage.
      6. 6Measure the current of the return line heater when it is switched on; a heater drawing no current is open.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Exhaust aftertreatment - Heater DEF return line - Voltage above normal or shorted to high source

    • Deutz SPN 4345 FMI 4Heater DEF return line: Voltage low / shorted low

      The EMR4 sees the output for the DEF return line heater (on the DEF return line from the dosing module to the tank) at a voltage below normal, as if the circuit is shorted to ground.· Shorted low
      Check soon

      Causes

      • Output wire chafed to ground or the engine block
      • DEF return line heater winding shorted to its housing
      • Water in the connector bridging the pins
      • Wire pinched against the engine block or frame so the signal is pulled to ground

      Checks

      1. 1Unplug the DEF return line heater: if the code changes, the part is the shorted one; if it stays, look at the harness
      2. 2With the EMR4 unplugged, measure the output wire to ground; it should not be low ohms
      3. 3Measure the winding resistance of the part and look for a very low value
      4. 4With the connector unplugged, measure the heater DEF return line signal wire against ground; a low resistance means a harness short, while an open reading sends you to the part itself.
      5. 5Trace the heater wire along the return line for damage.
      6. 6Measure the current of the return line heater when it is switched on; a heater drawing no current is open.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Exhaust aftertreatment - Heater DEF return line - Voltage below normal or shorted to low source

    • Deutz SPN 4345 FMI 5Heater DEF return line: Current low / open circuit

      The EMR4 sees too little current through the DEF return line heater (on the DEF return line from the dosing module to the tank), which means the circuit is open.· Open circuit
      Check soon

      Causes

      • Broken wire or a pin pushed out of the connector
      • DEF return line heater winding open
      • Connector left unplugged after earlier work
      • Terminal pushed back or corroded in its connector so the circuit is open

      Checks

      1. 1Measure the resistance across the DEF return line heater terminals: infinity means an open winding
      2. 2Continuity-test each wire to the matching EMR4 pin
      3. 3Inspect both ends of the DEF return line heater circuit (EMR4 plug and part connector) for pins pushed back in the housing
      4. 4Check the continuity of both wires between the EMR4 plug and the heater DEF return line connector, then the coil resistance, to separate a broken wire from a dead coil.
      5. 5Trace the heater wire along the return line for damage.
      6. 6Measure the current of the return line heater when it is switched on; a heater drawing no current is open.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

      Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

      Source wording:Exhaust aftertreatment - Heater DEF return line - Current below normal or open circuit

    • Deutz SPN 4345 FMI 11Heater DEF return line: Root cause not known

      The EMR4 logged a fault on the DEF return line heater (on the DEF return line from the dosing module to the tank) but could not classify the cause.· Other
      Check soon

      Causes

      • Intermittent wiring fault
      • Failing DEF return line heater
      • Intermittent contact that left no clear electrical signature

      Checks

      1. 1Read the full SerDia fault list; this code often sits next to a clearer one on the DEF return line heater
      2. 2Measure the supply and ground at the DEF return line heater plug with the key on to confirm it is powered
      3. 3Inspect the DEF return line heater plug and harness for chafed insulation, bent pins and moisture
      4. 4Read the freeze frame stored with the heater DEF return line fault and note speed, load and battery voltage at the moment it was logged.
      5. 5Trace the heater wire along the return line for damage.
      6. 6Measure the current of the return line heater when it is switched on; a heater drawing no current is open.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • DEF tank heating valve3 codes

    • Deutz SPN 4366 FMI 3DEF tank heating valve: Voltage high / shorted high

      The EMR4 sees the output for the DEF tank heating valve (in the SCR dosing module heating circuit) at a voltage above normal, as if the circuit is shorted to the battery supply.· Shorted high
      Check soon

      Causes

      • Output wire shorted to battery positive
      • Connector pin touching a live pin
      • DEF tank heating valve shorted internally
      • Harness insulation worn through where it rubs on a bracket, letting the wire touch a live supply

      Checks

      1. 1Unplug the DEF tank heating valve: if the code stays, the short is in the harness or the EMR4; if it clears, the part is the shorted one
      2. 2With the EMR4 unplugged, measure the output wire to battery positive; it should be open
      3. 3Measure the winding or coil resistance of the part
      4. 4With the EMR4 and the DEF tank heating valve unplugged, measure the signal wire against battery positive; it must read open, and any reading means the harness is shorted high.
      5. 5Check that coolant reaches the heating valve and that it switches.
      6. 6Feel the coolant hoses at the tank heating valve: one side should warm when the valve opens.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Exhaust aftertreatment - DEF tank heating valve - Voltage above normal or shorted to high source

    • Deutz SPN 4366 FMI 4DEF tank heating valve: Voltage low / shorted low

      The EMR4 sees the output for the DEF tank heating valve (in the SCR dosing module heating circuit) at a voltage below normal, as if the circuit is shorted to ground.· Shorted low
      Check soon

      Causes

      • Output wire chafed to ground or the engine block
      • DEF tank heating valve winding shorted to its housing
      • Water in the connector bridging the pins
      • Wire pinched against the engine block or frame so the signal is pulled to ground

      Checks

      1. 1Unplug the DEF tank heating valve: if the code changes, the part is the shorted one; if it stays, look at the harness
      2. 2With the EMR4 unplugged, measure the output wire to ground; it should not be low ohms
      3. 3Measure the winding resistance of the part and look for a very low value
      4. 4With the connector unplugged, measure the DEF tank heating valve signal wire against ground; a low resistance means a harness short, while an open reading sends you to the part itself.
      5. 5Check that coolant reaches the heating valve and that it switches.
      6. 6Feel the coolant hoses at the tank heating valve: one side should warm when the valve opens.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Exhaust aftertreatment - DEF tank heating valve - Voltage below normal or shorted to low source

    • Deutz SPN 4366 FMI 5DEF tank heating valve: Current low / open circuit

      The EMR4 sees too little current through the DEF tank heating valve (in the SCR dosing module heating circuit), which means the circuit is open.· Open circuit
      Check soon

      Causes

      • Broken wire or a pin pushed out of the connector
      • DEF tank heating valve winding open
      • Connector left unplugged after earlier work
      • Terminal pushed back or corroded in its connector so the circuit is open

      Checks

      1. 1Measure the resistance across the DEF tank heating valve terminals: infinity means an open winding
      2. 2Continuity-test each wire to the matching EMR4 pin
      3. 3Inspect both ends of the DEF tank heating valve circuit (EMR4 plug and part connector) for pins pushed back in the housing
      4. 4Check the continuity of both wires between the EMR4 plug and the DEF tank heating valve connector, then the coil resistance, to separate a broken wire from a dead coil.
      5. 5Check that coolant reaches the heating valve and that it switches.
      6. 6Feel the coolant hoses at the tank heating valve: one side should warm when the valve opens.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

      Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

      Source wording:Exhaust aftertreatment - DEF tank heating valve - Current below normal or open circuit

  • DEF tank heater1 code

    • Deutz SPN 523981 FMI 11DEF tank heater: Root cause not known

      The EMR4 logged a fault on the DEF tank heater (in the SCR dosing module heating circuit) but could not classify the cause.· Other
      Check soon

      Causes

      • Intermittent wiring fault
      • Failing DEF tank heater
      • Intermittent contact that left no clear electrical signature

      Checks

      1. 1Read the full SerDia fault list; this code often sits next to a clearer one on the DEF tank heater
      2. 2Measure the supply and ground at the DEF tank heater plug with the key on to confirm it is powered
      3. 3Inspect the DEF tank heater plug and harness for chafed insulation, bent pins and moisture
      4. 4Read the freeze frame stored with the DEF tank heater fault and note speed, load and battery voltage at the moment it was logged.
      5. 5Check the tank unit connector for DEF corrosion.
      6. 6Compare the tank temperature rise in SerDia with the heater state after a cold soak.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • DEF heater4 codes

    • Deutz SPN 524063 FMI 3DEF heater: Voltage high / shorted high

      The EMR4 sees the output for the DEF heater (in the DEF tank or line that keeps the DEF thawed) at a voltage above normal, as if the circuit is shorted to the battery supply.· Shorted high
      Check soon

      Causes

      • DEF heater shorted internally
      • Output wire shorted to battery positive
      • Heater element open or shorted
      • Connector pin touching a live pin
      • Harness insulation worn through where it rubs on a bracket, letting the wire touch a live supply

      Checks

      1. 1Measure the heater element resistance and check its fuse
      2. 2With the EMR4 unplugged, measure the output wire to battery positive; it should be open
      3. 3Check the heater wiring at the tank unit connector for corrosion
      4. 4With the EMR4 and the DEF heater unplugged, measure the signal wire against battery positive; it must read open, and any reading means the harness is shorted high.
      5. 5Measure the DEF heater element resistance.
      6. 6Check the shared heater supply fuse, which can take several DEF heaters out together.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Exhaust aftertreatment - DEF heater - Voltage above normal or shorted to high source

    • Deutz SPN 524063 FMI 4DEF heater: Voltage low / shorted low

      The EMR4 sees the output for the DEF heater (in the DEF tank or line that keeps the DEF thawed) at a voltage below normal, as if the circuit is shorted to ground.· Shorted low
      Check soon

      Causes

      • Heater element open or shorted
      • Output wire chafed to ground or the engine block
      • DEF heater winding shorted to its housing
      • Water in the connector bridging the pins
      • Wire pinched against the engine block or frame so the signal is pulled to ground

      Checks

      1. 1Measure the winding resistance of the part and look for a very low value
      2. 2Measure the heater element resistance and check its fuse
      3. 3Unplug the DEF heater: if the code changes, the part is the shorted one; if it stays, look at the harness
      4. 4Check the heater wiring at the tank unit connector for corrosion
      5. 5With the connector unplugged, measure the DEF heater signal wire against ground; a low resistance means a harness short, while an open reading sends you to the part itself.
      6. 6Check the shared heater supply fuse, which can take several DEF heaters out together.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Exhaust aftertreatment - DEF heater - Voltage below normal or shorted to low source

    • Deutz SPN 524063 FMI 5DEF heater: Current low / open circuit

      The EMR4 sees too little current through the DEF heater (in the DEF tank or line that keeps the DEF thawed), which means the circuit is open.· Open circuit
      Check soon

      Causes

      • Heater element open or shorted
      • Connector left unplugged after earlier work
      • Broken wire or a pin pushed out of the connector
      • Terminal pushed back or corroded in its connector so the circuit is open

      Checks

      1. 1Continuity-test each wire to the matching EMR4 pin
      2. 2Measure the resistance across the DEF heater terminals: infinity means an open winding
      3. 3Check the heater wiring at the tank unit connector for corrosion
      4. 4Inspect both ends of the DEF heater circuit (EMR4 plug and part connector) for pins pushed back in the housing
      5. 5Check the continuity of both wires between the EMR4 plug and the DEF heater connector, then the coil resistance, to separate a broken wire from a dead coil.
      6. 6Check the shared heater supply fuse, which can take several DEF heaters out together.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

      Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

      Source wording:Exhaust aftertreatment - DEF heater - Current below normal or open circuit

    • Deutz SPN 524063 FMI 12DEF heater: Bad device or component

      The EMR4 judges the DEF heater (in the DEF tank or line that keeps the DEF thawed) to be a bad device, meaning the part or its driver electronics no longer respond as a working component.· Part or controller
      Check soon

      Causes

      • Internal failure of the DEF heater
      • Water or soot inside the part
      • Driver stage in the EMR4 failing
      • Electronics inside the part damaged by heat, water or a voltage spike

      Checks

      1. 1Read the DEF heater status in SerDia and run any actuator test
      2. 2Measure supply voltage and ground at the DEF heater connector with the key on to confirm the part is powered
      3. 3Fit a known good DEF heater if you can borrow one and see whether the code clears for good
      4. 4Check supply voltage and ground at the DEF heater connector under load; if both are good the part itself is the likely culprit and a swap with a known good one confirms it.
      5. 5Measure the DEF heater element resistance.
      6. 6Check the shared heater supply fuse, which can take several DEF heaters out together.
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Exhaust aftertreatment - DEF heater - Bad intelligent device or component

Shared checks

Checks, in order

  1. 1Measure the heater or valve coil resistance for the part named in the code
  2. 2Check the heating valve and relay for supply and ground
  3. 3Inspect the connectors for crystallised DEF
  4. 4Check that coolant reaches the tank heating valve and that the valve switches in cold conditions

Causes

  • Heater element open or shorted
  • Heater valve or relay failed
  • Connector corroded by DEF
  • Coolant flow to the tank heating valve restricted

Most common here: shorted high (6 of 23)

Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

When to stop

You'll notice: A warning lamp or limited function.

Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.