Cummins · Fuel system
Cummins Injector solenoid circuits (cylinders 1 to 6) fault codes
Each injector has a solenoid that the ECM fires once or several times per cycle. The ECM monitors each solenoid driver circuit for open circuits and for mechanical response.
Where to read it
Connect INSITE or another J1939-capable scan tool to the 9-pin diagnostic port.
What do these codes mean?
Cummins codes 322 to 1145 are all about the injector solenoid circuits (cylinders 1 to 6). The most common failure type is open circuit (6 of 12); none needs an immediate stop. Start with this check: run the injector test in INSITE and see which cylinders fail.
How urgent are they?
None of the 12 codes here means stop now; all 12 can wait until the shift ends, but find the cause before the next one.
- Check soon12
What should I check first?
Run the injector test in INSITE and see which cylinders fail
Shared checks12 of 12
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Cummins 322Injector solenoid circuit, cylinder 1 open circuit
The ECM finds no current flowing in the injector solenoid circuit, cylinder 1 circuit when it commands it on, so the circuit is open or the load is unplugged. Cylinder 1 injector circuit.· Open circuitOpen circuitCheck soonCauses
- Injector solenoid coil open on cylinder 1
- Injector connector under the valve cover loose
- Harness wire broken at the cylinder 1 injector
- Oil-soaked harness insulation failing
Checks
- 1Run the cylinder cut-out test in INSITE and see whether cylinder 1 makes any contribution
- 2Remove the valve cover and check the injector connector
- 3Measure the injector coil resistance against the service value
- 4Test the wires from the injector to the ECM for continuity
- 5Replace the injector or the harness section that fails the resistance or continuity test
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Cummins 323Injector solenoid driver cylinder 5 circuit - Current low / open circuit
Same failure as 322 on the injector solenoid driver cylinder 5 circuit: the same fault condition as 322, reported for this part. This is the electrical side of one injector: the ECM drives the solenoid coil and measures the current that flows.· Open circuitOpen circuitCheck soonCauses
- Same causes as 322, applied to the injector solenoid driver cylinder 5 circuit
- Wiring or connector problem local to the injector solenoid driver cylinder 5 circuit
Checks
- 1Measure the injector coil resistance at the injector connector and compare it with the other cylinders.
- 2Work through the checks listed for 322, starting at the injector solenoid driver cylinder 5 circuit and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Source wording:Injector solenoid driver cylinder 5 circuit - current low or open circuit
Cummins 324Injector solenoid driver cylinder 3 circuit - Current low / open circuit
Same failure as 322 on the injector solenoid driver cylinder 3 circuit: the same fault condition as 322, reported for this part. This is the electrical side of one injector: the ECM drives the solenoid coil and measures the current that flows.· Open circuitOpen circuitCheck soonCauses
- Same causes as 322, applied to the injector solenoid driver cylinder 3 circuit
- Wiring or connector problem local to the injector solenoid driver cylinder 3 circuit
Checks
- 1Measure the injector coil resistance at the injector connector and compare it with the other cylinders.
- 2Work through the checks listed for 322, starting at the injector solenoid driver cylinder 3 circuit and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Source wording:Injector solenoid driver cylinder 3 circuit - current low or open circuit
Cummins 325Injector solenoid driver cylinder 6 circuit - Current low / open circuit
Same failure as 322 on the injector solenoid driver cylinder 6 circuit: the same fault condition as 322, reported for this part. This is the electrical side of one injector: the ECM drives the solenoid coil and measures the current that flows.· Open circuitOpen circuitCheck soonCauses
- Same causes as 322, applied to the injector solenoid driver cylinder 6 circuit
- Wiring or connector problem local to the injector solenoid driver cylinder 6 circuit
Checks
- 1Measure the injector coil resistance at the injector connector and compare it with the other cylinders.
- 2Work through the checks listed for 322, starting at the injector solenoid driver cylinder 6 circuit and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Source wording:Injector solenoid driver cylinder 6 circuit - current low or open circuit
Cummins 331Injector solenoid driver cylinder 2 circuit - Current low / open circuit
Same failure as 322 on the injector solenoid driver cylinder 2 circuit: the same fault condition as 322, reported for this part. This is the electrical side of one injector: the ECM drives the solenoid coil and measures the current that flows.· Open circuitOpen circuitCheck soonCauses
- Same causes as 322, applied to the injector solenoid driver cylinder 2 circuit
- Wiring or connector problem local to the injector solenoid driver cylinder 2 circuit
Checks
- 1Measure the injector coil resistance at the injector connector and compare it with the other cylinders.
- 2Work through the checks listed for 322, starting at the injector solenoid driver cylinder 2 circuit and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Source wording:Injector solenoid driver cylinder 2 circuit - current low or open circuit
Cummins 332Injector solenoid driver cylinder 4 circuit - Current low / open circuit
Same failure as 322 on the injector solenoid driver cylinder 4 circuit: the same fault condition as 322, reported for this part. This is the electrical side of one injector: the ECM drives the solenoid coil and measures the current that flows.· Open circuitOpen circuitCheck soonCauses
- Same causes as 322, applied to the injector solenoid driver cylinder 4 circuit
- Wiring or connector problem local to the injector solenoid driver cylinder 4 circuit
Checks
- 1Measure the injector coil resistance at the injector connector and compare it with the other cylinders.
- 2Work through the checks listed for 322, starting at the injector solenoid driver cylinder 4 circuit and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Source wording:Injector solenoid driver cylinder 4 circuit - current low or open circuit
Cummins 1139Injector solenoid driver cylinder 1 - Mechanical fault
The ECM fired the injector solenoid driver cylinder 1 but did not see the current signature of a moving needle, so it reports a mechanical fault or no response even if the wiring tests normal. This is the mechanical side of one injector: the ECM sees that the solenoid current did not show the expected needle response.· OtherOtherCheck soonCauses
- Injector control valve stuck from varnish or contamination
- Injector coil failing when hot
- Poor connector contact that only shows under vibration
Checks
- 1Run the injector test in INSITE and see which cylinder fails and whether it passes when cold
- 2Check the injector wiring and the valve cover connector for oil and corrosion
- 3Check fuel pressure and fuel quality for contamination
- 4Do a cylinder cutout in INSITE and check the injector for sticking, low compression or a sheared hold-down.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Cummins 1141Injector solenoid driver cylinder 2 - Mechanical fault or not responding
Same failure as 1139 on the injector solenoid driver cylinder 2: the same fault condition as 1139, reported for this part. This is the mechanical side of one injector: the ECM sees that the solenoid current did not show the expected needle response.· Part or controllerPart or controllerCheck soonCauses
- Same causes as 1139, applied to the injector solenoid driver cylinder 2
- Wiring or connector problem local to the injector solenoid driver cylinder 2
Checks
- 1Do a cylinder cutout in INSITE and check the injector for sticking, low compression or a sheared hold-down.
- 2Work through the checks listed for 1139, starting at the injector solenoid driver cylinder 2 and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Cummins 1142Injector solenoid driver cylinder 3 - Mechanical fault or not responding
Same failure as 1139 on the injector solenoid driver cylinder 3: the same fault condition as 1139, reported for this part. This is the mechanical side of one injector: the ECM sees that the solenoid current did not show the expected needle response.· Part or controllerPart or controllerCheck soonCauses
- Same causes as 1139, applied to the injector solenoid driver cylinder 3
- Wiring or connector problem local to the injector solenoid driver cylinder 3
Checks
- 1Do a cylinder cutout in INSITE and check the injector for sticking, low compression or a sheared hold-down.
- 2Work through the checks listed for 1139, starting at the injector solenoid driver cylinder 3 and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Cummins 1143Injector solenoid driver cylinder 4 - Mechanical fault or not responding
Same failure as 1139 on the injector solenoid driver cylinder 4: the same fault condition as 1139, reported for this part. This is the mechanical side of one injector: the ECM sees that the solenoid current did not show the expected needle response.· Part or controllerPart or controllerCheck soonCauses
- Same causes as 1139, applied to the injector solenoid driver cylinder 4
- Wiring or connector problem local to the injector solenoid driver cylinder 4
Checks
- 1Do a cylinder cutout in INSITE and check the injector for sticking, low compression or a sheared hold-down.
- 2Work through the checks listed for 1139, starting at the injector solenoid driver cylinder 4 and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Cummins 1144Injector solenoid driver cylinder 5 - Mechanical fault or not responding
Same failure as 1139 on the injector solenoid driver cylinder 5: the same fault condition as 1139, reported for this part. This is the mechanical side of one injector: the ECM sees that the solenoid current did not show the expected needle response.· Part or controllerPart or controllerCheck soonCauses
- Same causes as 1139, applied to the injector solenoid driver cylinder 5
- Wiring or connector problem local to the injector solenoid driver cylinder 5
Checks
- 1Do a cylinder cutout in INSITE and check the injector for sticking, low compression or a sheared hold-down.
- 2Work through the checks listed for 1139, starting at the injector solenoid driver cylinder 5 and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Cummins 1145Injector solenoid driver cylinder 6 - Mechanical fault or not responding
Same failure as 1139 on the injector solenoid driver cylinder 6: the same fault condition as 1139, reported for this part. This is the mechanical side of one injector: the ECM sees that the solenoid current did not show the expected needle response.· Part or controllerPart or controllerCheck soonCauses
- Same causes as 1139, applied to the injector solenoid driver cylinder 6
- Wiring or connector problem local to the injector solenoid driver cylinder 6
Checks
- 1Do a cylinder cutout in INSITE and check the injector for sticking, low compression or a sheared hold-down.
- 2Work through the checks listed for 1139, starting at the injector solenoid driver cylinder 6 and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Shared checks
Checks, in order
- 1Run the injector test in INSITE and see which cylinders fail
- 2Measure each injector coil resistance at the terminals and compare the cylinders
- 3Inspect the valve cover feed-through and injector connectors for oil, corrosion and loose pins
- 4Check continuity of the injector wires between the connector and the ECM
- 5Swap a suspect injector with another cylinder to see whether the fault follows the injector
Causes
- Injector coil open or shorted inside the injector body
- Wire or connector fault between the valve cover feed-through and the ECM
- Oil or coolant soaked into the injector connector under the valve cover
- Injector control valve sticking from contamination
Most common here: open circuit (6 of 12)
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
When to stop
You'll notice: The affected cylinder runs weak or dead: rough running, white or black smoke, loss of power and sometimes a derate.
Common-rail fuel runs at very high pressure. Never open a high-pressure line or fitting with the engine running or just after it stops - a fine fuel jet can pierce skin.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.