EF Logo

Bobcat · Hydraulics

Bobcat Lift and tilt spool position sensors and lift float fault codes

A position sensor on the lift spool and one on the tilt spool tell the controller where each spool actually is, so it can compare it with the command. Codes report the sensor out of range high or low, unresponsive, inverted or not in neutral, plus the lift float function failing to achieve or hold float.

FaultCheckC104A-00Bobcat · Lift and tilt spool position sensors and lift float
Code shows hereFAULTC104A-00

Where this code shows

On touchscreen R-series machines, touch the screen and pick Service Codes from the menu.

What do these codes mean?

Bobcat codes C104A-00 to W5004 are all about the lift and tilt spool position sensors and lift float. The most common failure type is erratic or implausible (2 of 25); none needs an immediate stop. Start with this check: command the function from neutral and watch the spool sensor value on the service screen; it should move smoothly and return to neutral.

How urgent are they?

None of the 25 codes here means stop now; all 25 can wait until the shift ends, but find the cause before the next one.

  • Check soon25

What should I check first?

Command the function from neutral and watch the spool sensor value on the service screen; it should move smoothly and return to neutral.

Shared checks

25 of 25

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Bobcat C104A-00Lift float failed to achieve float

    The controller tried to put the lift arms into float and could not achieve it, so the arms stay under power instead of floating freely over the ground.· Other
    Check soon

    Causes

    • Float solenoid or valve not responding
    • Float conditions not met, such as cold oil or low pressure
    • Workgroup calibration lost

    Checks

    1. 1Select float again and watch the lift spool position and float state on the service screen.
    2. 2Warm the machine and check the hydraulic oil level.
    3. 3Check the lift spool sensor and lift valve connectors.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat C104B-00Lift float conditions not favorable

    Float was requested but the controller judged the conditions not favourable, so it refused to enter float; this is a refusal, not a part failure.· Other
    Check soon

    Causes

    • Hydraulic oil too cold or too hot
    • Machine not in a state that allows float
    • Operator input not in neutral

    Checks

    1. 1Warm the machine to normal operating temperature and try float again.
    2. 2Release the lift control fully before selecting float.
    3. 3Check for other active lift or hydraulic codes.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat C104C-00Lift float failed to maintain float

    The lift arms entered float but the controller could not keep them in float, so the arms drop out of float or are driven again while floating.· Other
    Check soon

    Causes

    • Lift input touched during float
    • Spool sensor or valve fault dropping out of float
    • Pressure fluctuation holding the spool off float

    Checks

    1. 1Select float and leave the lift control untouched while watching whether float holds.
    2. 2Check the lift spool sensor reading while in float.
    3. 3Check the lift valve connectors for loose pins.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat W0521Lift spool position sensor out of range high

    Lift spool position sensor out of range high: same fault as C1015-17 (the signal is above its normal range), here on the lift spool position sensor.· Other
    Check soon

    Causes

    • Signal wire shorted to the 5 V or battery supply
    • Sensor failed with its output pinned high

    Checks

    1. 1Unplug the lift spool position sensor and measure the signal wire for a short to supply.
    2. 2Test steps: see C1015-17.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat W0522Lift spool position sensor out of range low

    Lift spool position sensor out of range low: same fault as C1015-16 (the signal is below its normal range), here on the lift spool position sensor.· Other
    Check soon

    Causes

    • Signal wire shorted to ground
    • Supply wire to the sensor open or the sensor not powered

    Checks

    1. 1Measure the 5 V reference and the signal wire to ground at the lift spool position sensor plug.
    2. 2Test steps: see C1015-16.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat W0524Lift spool position sensor not in neutral

    Lift spool position sensor not in neutral: same fault as C1015-F0 (the input reads away from neutral), here on the lift spool position sensor.· Other
    Check soon

    Causes

    • Part held off neutral by dirt or a bent linkage
    • Sensor drifted or out of calibration

    Checks

    1. 1Release the control and read the lift spool position sensor value on the service screen.
    2. 2Test steps: see C1015-F0.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat W0525Lift spool position sensor unresponsive

    Lift spool position sensor unresponsive: same fault as C1015-93 (the signal does not respond to commanded movement), here on the lift spool position sensor.· Other
    Check soon

    Causes

    • Sensor or its linkage stuck
    • Connector or supply fault

    Checks

    1. 1Command a movement and watch whether the lift spool position sensor value changes.
    2. 2Test steps: see C1015-93.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat W0595Lift spool position sensor inverted movement

    Lift spool position sensor inverted movement: same fault as C1015-56 (the sensor moves opposite to the command), here on the lift spool position sensor.· Other
    Check soon

    Causes

    • Sensor or its wires fitted reversed after a repair
    • Wrong sensor type fitted

    Checks

    1. 1Command a movement and compare the lift spool position sensor direction with the command.
    2. 2Test steps: see C1015-56.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat W0621Tilt spool position sensor out of range high

    Tilt spool position sensor out of range high: same fault as C1015-17 (the signal is above its normal range), here on the tilt spool position sensor.· Other
    Check soon

    Causes

    • Signal wire shorted to the 5 V or battery supply
    • Sensor failed with its output pinned high

    Checks

    1. 1Unplug the tilt spool position sensor and measure the signal wire for a short to supply.
    2. 2Test steps: see C1015-17.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat W0622Tilt spool position sensor out of range low

    Tilt spool position sensor out of range low: same fault as C1015-16 (the signal is below its normal range), here on the tilt spool position sensor.· Other
    Check soon

    Causes

    • Signal wire shorted to ground
    • Supply wire to the sensor open or the sensor not powered

    Checks

    1. 1Measure the 5 V reference and the signal wire to ground at the tilt spool position sensor plug.
    2. 2Test steps: see C1015-16.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat W0624Tilt spool position sensor not in neutral

    Tilt spool position sensor not in neutral: same fault as C1015-F0 (the input reads away from neutral), here on the tilt spool position sensor.· Other
    Check soon

    Causes

    • Part held off neutral by dirt or a bent linkage
    • Sensor drifted or out of calibration

    Checks

    1. 1Release the control and read the tilt spool position sensor value on the service screen.
    2. 2Test steps: see C1015-F0.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat W0625Tilt spool position sensor unresponsive

    Tilt spool position sensor unresponsive: same fault as C1015-93 (the signal does not respond to commanded movement), here on the tilt spool position sensor.· Other
    Check soon

    Causes

    • Sensor or its linkage stuck
    • Connector or supply fault

    Checks

    1. 1Command a movement and watch whether the tilt spool position sensor value changes.
    2. 2Test steps: see C1015-93.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat W0695Tilt spool position sensor inverted movement

    Tilt spool position sensor inverted movement: same fault as C1015-56 (the sensor moves opposite to the command), here on the tilt spool position sensor.· Other
    Check soon

    Causes

    • Sensor or its wires fitted reversed after a repair
    • Wrong sensor type fitted

    Checks

    1. 1Command a movement and compare the tilt spool position sensor direction with the command.
    2. 2Test steps: see C1015-56.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat C1015-F0Lift spool position sensor not in neutral

    The controller sees the spool position sensor away from neutral when it should be at rest, so the lift or tilt moves slowly, stops or drifts because the controller cannot trust the spool position.· Erratic or implausible
    Check soon

    Causes

    • Part held off neutral by dirt or a bent linkage
    • Sensor drifted or out of calibration
    • Spring weak or broken
    • Operator control held while starting

    Checks

    1. 1Release the control fully and read the spool position sensor value on the service screen; it should sit at neutral.
    2. 2Check the linkage and return spring for binding.
    3. 3Recalibrate the neutral position if the part moves freely but still reads off neutral.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Bobcat C1015-16Lift spool position sensor out of range low

    The controller reads the spool position sensor spool position signal below its normal range, typically a wire shorted to ground, an open supply or a sensor failed low, so the lift or tilt moves slowly, stops or drifts because the controller cannot trust the spool position.· Shorted low
    Check soon

    Causes

    • Signal wire shorted to ground
    • Supply wire to the sensor open or the sensor not powered
    • Sensor failed with its output pinned low
    • Pin backed out of the connector

    Checks

    1. 1Measure the 5 V reference at the spool position sensor plug; no reference means the fault is in the supply wire, not the sensor.
    2. 2Unplug the sensor and measure the signal wire to ground for a short.
    3. 3Check the connector at the spool sensor plug on the valve block for a backed-out pin.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat C1015-17Lift spool position sensor out of range high

    The controller reads the spool position sensor spool position signal above its normal range, which is usually a wire shorted to supply or a sensor that has failed high, so the lift or tilt moves slowly, stops or drifts because the controller cannot trust the spool position.· Shorted high
    Check soon

    Causes

    • Signal wire shorted to the 5 V or battery supply
    • Sensor failed with its output pinned high
    • Ground wire open so the signal floats high
    • Water in the connector bridging signal to supply

    Checks

    1. 1Unplug the spool position sensor and measure the signal wire with the key on; a high voltage with the sensor removed means a short in the harness.
    2. 2Check the sensor ground at the plug; an open ground drives the signal high.
    3. 3Measure the 5 V reference at the spool position sensor plug to confirm it is not above 5 V.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat C1015-56Lift spool position sensor inverted movement

    The spool position sensor moves the opposite way to the command, so the controller flags inverted movement and the lift or tilt moves slowly, stops or drifts because the controller cannot trust the spool position.· Erratic or implausible
    Check soon

    Causes

    • Sensor or its wires fitted reversed after a repair
    • Wrong sensor type fitted
    • Calibration done with the sensor reversed

    Checks

    1. 1Command a movement and compare the direction of the spool position sensor reading with the command.
    2. 2Check the wiring to the spool position sensor against the schematic for swapped signal and supply wires.
    3. 3Recalibrate after correcting the wiring.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Bobcat C1015-93Lift spool position sensor unresponsive

    The controller sees no response from the spool position sensor when the machine is commanded to move, so the lift or tilt moves slowly, stops or drifts because the controller cannot trust the spool position.· Open circuit
    Check soon

    Causes

    • Sensor or its linkage stuck
    • Connector or supply fault
    • Spool or part not moving because of dirt

    Checks

    1. 1Command a movement and watch the spool position sensor value on the service screen; no change confirms an unresponsive signal.
    2. 2Check the sensor connector at the spool sensor plug on the valve block and its supply.
    3. 3Check the part it measures moves freely by hand where accessible.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat C1016-F0Tilt spool position sensor not in neutral

    Tilt spool position sensor not in neutral: same fault as C1015-F0 (the input reads away from neutral), here on the tilt spool position sensor.· Other
    Check soon

    Causes

    • Part held off neutral by dirt or a bent linkage
    • Sensor drifted or out of calibration

    Checks

    1. 1Release the control and read the tilt spool position sensor value on the service screen.
    2. 2Test steps: see C1015-F0.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat C1016-16Tilt spool position sensor out of range low

    Tilt spool position sensor out of range low: same fault as C1015-16 (the signal is below its normal range), here on the tilt spool position sensor.· Other
    Check soon

    Causes

    • Signal wire shorted to ground
    • Supply wire to the sensor open or the sensor not powered

    Checks

    1. 1Measure the 5 V reference and the signal wire to ground at the tilt spool position sensor plug.
    2. 2Test steps: see C1015-16.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat C1016-17Tilt spool position sensor out of range high

    Tilt spool position sensor out of range high: same fault as C1015-17 (the signal is above its normal range), here on the tilt spool position sensor.· Other
    Check soon

    Causes

    • Signal wire shorted to the 5 V or battery supply
    • Sensor failed with its output pinned high

    Checks

    1. 1Unplug the tilt spool position sensor and measure the signal wire for a short to supply.
    2. 2Test steps: see C1015-17.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat C1016-93Tilt spool position sensor unresponsive

    Tilt spool position sensor unresponsive: same fault as C1015-93 (the signal does not respond to commanded movement), here on the tilt spool position sensor.· Other
    Check soon

    Causes

    • Sensor or its linkage stuck
    • Connector or supply fault

    Checks

    1. 1Command a movement and watch whether the tilt spool position sensor value changes.
    2. 2Test steps: see C1015-93.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat C1041-00Lift spool position sensor inverted movement

    Lift spool position sensor inverted movement: same fault as C1015-56 (the sensor moves opposite to the command), here on the lift spool position sensor.· Other
    Check soon

    Causes

    • Sensor or its wires fitted reversed after a repair
    • Wrong sensor type fitted

    Checks

    1. 1Command a movement and compare the lift spool position sensor direction with the command.
    2. 2Test steps: see C1015-56.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat C1046-00Tilt spool position sensor inverted movement

    Tilt spool position sensor inverted movement: same fault as C1015-56 (the sensor moves opposite to the command), here on the tilt spool position sensor.· Other
    Check soon

    Causes

    • Sensor or its wires fitted reversed after a repair
    • Wrong sensor type fitted

    Checks

    1. 1Command a movement and compare the tilt spool position sensor direction with the command.
    2. 2Test steps: see C1015-56.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat W5004Lift float failed to maintain float

    Lift float failed to maintain float: same fault as C104C-00 (float could not be maintained), here on the lift float failed to maintain float.· Other
    Check soon

    Causes

    • Lift input touched during float
    • Spool sensor or valve fault dropping out of float

    Checks

    1. 1Select float and leave the control untouched to see whether it holds.
    2. 2Test steps: see C104C-00.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

Shared checks

Checks, in order

  1. 1Command the function from neutral and watch the spool sensor value on the service screen; it should move smoothly and return to neutral.
  2. 2Check the sensor connector and the 5 V supply and ground at its plug.
  3. 3Look for a sticking spool: spool lag with a good sensor signal points to the valve, not the sensor.
  4. 4After valve or sensor replacement, run the workgroup calibration so the neutral position is relearned.
  5. 5For float codes, check hydraulic oil temperature, charge pressure and any active lift codes before testing the float solenoid circuit.

Causes

  • Spool position sensor failed or its connector damaged
  • Spool sticking from dirt so it does not follow the command
  • Sensor wiring reversed after a repair
  • Float conditions not met, such as low hydraulic pressure or temperature

Most common here: erratic or implausible (2 of 25)

Watch the live value on the service tool while you flex the harness and tap the connector.

When to stop

You'll notice: The lift or tilt moves slowly or not at all, drifts, or the controller stops the function; float may not engage.

Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.