EF Logo

Bobcat · Hydraulics

Bobcat E145/E165 pressure sensors fault codes

Pressure sensors on the pumps, the boom, arm and bucket circuits, travel and swing circuits and the attachment and option pedal circuits feed the E145 and E165 controller. A code names the sensor and whether its signal is out of range high or low.

FaultCheckVSP001-02Bobcat · E145/E165 pressure sensors
Code shows hereFAULTVSP001-02

Where this code shows

On touchscreen R-series machines, touch the screen and pick Service Codes from the menu.

What do these codes mean?

Bobcat codes VSP001-02 to VSP018-04 are all about the e145/E165 pressure sensors. The most common failure type is shorted low (18 of 39); none needs an immediate stop. Start with this check: compare the sensor reading on the service screen with a gauge at the matching test port.

How urgent are they?

None of the 39 codes here means stop now; all 39 can wait until the shift ends, but find the cause before the next one.

  • Check soon39

What should I check first?

Compare the sensor reading on the service screen with a gauge at the matching test port.

Shared checks

39 of 39

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Bobcat VSP001-02Front pump press. sensor, incorrect signal

    The controller reads an incorrect signal from the pressure sensor: the value does not match what the other sensors say about the machine, so the pump or circuit loses its pressure signal and the controller limits power.· Other
    Check soon

    Causes

    • Sensor failed or drifting
    • Poor connection
    • Real pressure or position outside what the sensors agree on

    Checks

    1. 1Compare the pressure sensor reading with the other related readings on the service screen.
    2. 2Reseat the connector and recheck.
    3. 3Check against a gauge before replacing the sensor.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat VSP001-03Front pump press. sensor, voltage above normal

    The controller reads the pressure sensor voltage above its normal range, so the sensor signal is shorted high or the sensor has failed, and the pump or circuit loses its pressure signal and the controller limits power.· Shorted high
    Check soon

    Causes

    • Signal wire shorted to supply
    • Sensor failed high
    • Open ground at the sensor

    Checks

    1. 1Unplug the pressure sensor and measure the signal wire; voltage with the sensor removed shows a short to supply.
    2. 2Check the sensor ground at the plug.
    3. 3Measure the sensor 5 V reference.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat VSP001-04Front pump press. sensor, voltage below normal

    The controller reads the pressure sensor voltage below its normal range, so the signal wire is shorted to ground, the supply is open or the sensor failed low, and the pump or circuit loses its pressure signal and the controller limits power.· Shorted low
    Check soon

    Causes

    • Signal wire shorted to ground
    • Supply or sensor wire open
    • Sensor failed low

    Checks

    1. 1Measure the sensor 5 V reference at the pressure sensor plug.
    2. 2Unplug the pressure sensor and measure the signal wire to ground.
    3. 3Check the connector for a backed-out pin.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat VSP002-02Rear pump press. sensor, incorrect signal

    Rear pump press. sensor, incorrect signal: same fault as VSP001-02 (the signal does not agree with related readings), here on the rear pump press sensor.· Other
    Check soon

    Causes

    • Sensor failed or drifting
    • Poor connection

    Checks

    1. 1Compare the rear pump press sensor reading with the related readings on the service screen.
    2. 2Test steps: see VSP001-02.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat VSP002-03Rear pump press. sensor, voltage above normal

    Rear pump press. sensor, voltage above normal: same fault as VSP001-03 (the voltage is above its normal range), here on the rear pump press sensor.· Shorted high
    Check soon

    Causes

    • Signal wire shorted to supply
    • Sensor failed high

    Checks

    1. 1Unplug the rear pump press sensor and measure the signal wire for voltage.
    2. 2Test steps: see VSP001-03.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat VSP002-04Rear pump press. sensor, voltage below normal

    Rear pump press. sensor, voltage below normal: same fault as VSP001-04 (the voltage is below its normal range), here on the rear pump press sensor.· Shorted low
    Check soon

    Causes

    • Signal wire shorted to ground
    • Supply or sensor wire open

    Checks

    1. 1Measure the 5 V reference and the signal wire to ground at the rear pump press sensor plug.
    2. 2Test steps: see VSP001-04.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat VSP003-02OWD press. sensor, incorrect signal

    OWD press. sensor, incorrect signal: same fault as VSP001-02 (the signal does not agree with related readings), here on the owd press sensor.· Other
    Check soon

    Causes

    • Sensor failed or drifting
    • Poor connection

    Checks

    1. 1Compare the owd press sensor reading with the related readings on the service screen.
    2. 2Test steps: see VSP001-02.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat VSP003-03OWD press. sensor, voltage above normal

    OWD press. sensor, voltage above normal: same fault as VSP001-03 (the voltage is above its normal range), here on the owd press sensor.· Shorted high
    Check soon

    Causes

    • Signal wire shorted to supply
    • Sensor failed high

    Checks

    1. 1Unplug the owd press sensor and measure the signal wire for voltage.
    2. 2Test steps: see VSP001-03.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat VSP003-04OWD press. sensor, voltage below normal

    OWD press. sensor, voltage below normal: same fault as VSP001-04 (the voltage is below its normal range), here on the owd press sensor.· Shorted low
    Check soon

    Causes

    • Signal wire shorted to ground
    • Supply or sensor wire open

    Checks

    1. 1Measure the 5 V reference and the signal wire to ground at the owd press sensor plug.
    2. 2Test steps: see VSP001-04.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat VSP004-03Px(front) press. sensor, voltage above normal

    Px(front) press. sensor, voltage above normal: same fault as VSP001-03 (the voltage is above its normal range), here on the px front press sensor.· Shorted high
    Check soon

    Causes

    • Signal wire shorted to supply
    • Sensor failed high

    Checks

    1. 1Unplug the px front press sensor and measure the signal wire for voltage.
    2. 2Test steps: see VSP001-03.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat VSP004-04Px(front) press. sensor, voltage below normal

    Px(front) press. sensor, voltage below normal: same fault as VSP001-04 (the voltage is below its normal range), here on the px front press sensor.· Shorted low
    Check soon

    Causes

    • Signal wire shorted to ground
    • Supply or sensor wire open

    Checks

    1. 1Measure the 5 V reference and the signal wire to ground at the px front press sensor plug.
    2. 2Test steps: see VSP001-04.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat VSP005-03Pressure sensor issue

    The controller reports a pressure sensor issue on the Py (travel) circuit, meaning its signal is not valid, so pressure-based control on that circuit is limited.· Other
    Check soon

    Causes

    • Sensor connector corroded or loose
    • Wiring fault on the sensor circuit
    • Sensor failed

    Checks

    1. 1Compare the sensor reading with a gauge at the travel test port.
    2. 2Check the sensor connector and the 5 V supply.
    3. 3Check the signal wire for shorts.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat VSP005-04Py(travel) press. sensor, voltage below normal

    Py(travel) press. sensor, voltage below normal: same fault as VSP001-04 (the voltage is below its normal range), here on the py travel press sensor.· Shorted low
    Check soon

    Causes

    • Signal wire shorted to ground
    • Supply or sensor wire open

    Checks

    1. 1Measure the 5 V reference and the signal wire to ground at the py travel press sensor plug.
    2. 2Test steps: see VSP001-04.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat VSP006-03Boom up press. sensor, voltage above normal

    Boom up press. sensor, voltage above normal: same fault as VSP001-03 (the voltage is above its normal range), here on the boom up press sensor.· Shorted high
    Check soon

    Causes

    • Signal wire shorted to supply
    • Sensor failed high

    Checks

    1. 1Unplug the boom up press sensor and measure the signal wire for voltage.
    2. 2Test steps: see VSP001-03.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat VSP006-04Boom up press. sensor, voltage below normal

    Boom up press. sensor, voltage below normal: same fault as VSP001-04 (the voltage is below its normal range), here on the boom up press sensor.· Shorted low
    Check soon

    Causes

    • Signal wire shorted to ground
    • Supply or sensor wire open

    Checks

    1. 1Measure the 5 V reference and the signal wire to ground at the boom up press sensor plug.
    2. 2Test steps: see VSP001-04.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat VSP007-03Bucket crowd press. sensor, voltage above normal

    Bucket crowd press. sensor, voltage above normal: same fault as VSP001-03 (the voltage is above its normal range), here on the bucket crowd press sensor.· Shorted high
    Check soon

    Causes

    • Signal wire shorted to supply
    • Sensor failed high

    Checks

    1. 1Unplug the bucket crowd press sensor and measure the signal wire for voltage.
    2. 2Test steps: see VSP001-03.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat VSP007-04Bucket crowd press. sensor, voltage below normal

    Bucket crowd press. sensor, voltage below normal: same fault as VSP001-04 (the voltage is below its normal range), here on the bucket crowd press sensor.· Shorted low
    Check soon

    Causes

    • Signal wire shorted to ground
    • Supply or sensor wire open

    Checks

    1. 1Measure the 5 V reference and the signal wire to ground at the bucket crowd press sensor plug.
    2. 2Test steps: see VSP001-04.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat VSP008-03Boom down press. sensor, voltage above normal

    Boom down press. sensor, voltage above normal: same fault as VSP001-03 (the voltage is above its normal range), here on the boom down press sensor.· Shorted high
    Check soon

    Causes

    • Signal wire shorted to supply
    • Sensor failed high

    Checks

    1. 1Unplug the boom down press sensor and measure the signal wire for voltage.
    2. 2Test steps: see VSP001-03.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat VSP008-04Boom down press. sensor, voltage below normal

    Boom down press. sensor, voltage below normal: same fault as VSP001-04 (the voltage is below its normal range), here on the boom down press sensor.· Shorted low
    Check soon

    Causes

    • Signal wire shorted to ground
    • Supply or sensor wire open

    Checks

    1. 1Measure the 5 V reference and the signal wire to ground at the boom down press sensor plug.
    2. 2Test steps: see VSP001-04.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat VSP009-03Bucket dump press. sensor, voltage above normal

    Bucket dump press. sensor, voltage above normal: same fault as VSP001-03 (the voltage is above its normal range), here on the bucket dump press sensor.· Shorted high
    Check soon

    Causes

    • Signal wire shorted to supply
    • Sensor failed high

    Checks

    1. 1Unplug the bucket dump press sensor and measure the signal wire for voltage.
    2. 2Test steps: see VSP001-03.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat VSP009-04Bucket dump press. sensor, voltage below normal

    Bucket dump press. sensor, voltage below normal: same fault as VSP001-04 (the voltage is below its normal range), here on the bucket dump press sensor.· Shorted low
    Check soon

    Causes

    • Signal wire shorted to ground
    • Supply or sensor wire open

    Checks

    1. 1Measure the 5 V reference and the signal wire to ground at the bucket dump press sensor plug.
    2. 2Test steps: see VSP001-04.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat VSP010-03Arm in press. sensor, voltage above normal

    Arm in press. sensor, voltage above normal: same fault as VSP001-03 (the voltage is above its normal range), here on the arm in press sensor.· Shorted high
    Check soon

    Causes

    • Signal wire shorted to supply
    • Sensor failed high

    Checks

    1. 1Unplug the arm in press sensor and measure the signal wire for voltage.
    2. 2Test steps: see VSP001-03.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat VSP010-04Arm in press. sensor, voltage below normal

    Arm in press. sensor, voltage below normal: same fault as VSP001-04 (the voltage is below its normal range), here on the arm in press sensor.· Shorted low
    Check soon

    Causes

    • Signal wire shorted to ground
    • Supply or sensor wire open

    Checks

    1. 1Measure the 5 V reference and the signal wire to ground at the arm in press sensor plug.
    2. 2Test steps: see VSP001-04.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat VSP011-03Arm out press. sensor, voltage above normal

    Arm out press. sensor, voltage above normal: same fault as VSP001-03 (the voltage is above its normal range), here on the arm out press sensor.· Shorted high
    Check soon

    Causes

    • Signal wire shorted to supply
    • Sensor failed high

    Checks

    1. 1Unplug the arm out press sensor and measure the signal wire for voltage.
    2. 2Test steps: see VSP001-03.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat VSP011-04Arm out press. sensor, voltage below normal

    Arm out press. sensor, voltage below normal: same fault as VSP001-04 (the voltage is below its normal range), here on the arm out press sensor.· Shorted low
    Check soon

    Causes

    • Signal wire shorted to ground
    • Supply or sensor wire open

    Checks

    1. 1Measure the 5 V reference and the signal wire to ground at the arm out press sensor plug.
    2. 2Test steps: see VSP001-04.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat VSP012-03Travel press. sensor(lh), voltage above normal

    Travel press. sensor(lh), voltage above normal: same fault as VSP001-03 (the voltage is above its normal range), here on the travel press sensor lh.· Shorted high
    Check soon

    Causes

    • Signal wire shorted to supply
    • Sensor failed high

    Checks

    1. 1Unplug the travel press sensor lh and measure the signal wire for voltage.
    2. 2Test steps: see VSP001-03.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat VSP012-04Travel press. sensor(lh), voltage below normal

    Travel press. sensor(lh), voltage below normal: same fault as VSP001-04 (the voltage is below its normal range), here on the travel press sensor lh.· Shorted low
    Check soon

    Causes

    • Signal wire shorted to ground
    • Supply or sensor wire open

    Checks

    1. 1Measure the 5 V reference and the signal wire to ground at the travel press sensor lh plug.
    2. 2Test steps: see VSP001-04.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat VSP013-03Travel press. sensor(rh), voltage above normal

    Travel press. sensor(rh), voltage above normal: same fault as VSP001-03 (the voltage is above its normal range), here on the travel press sensor rh.· Shorted high
    Check soon

    Causes

    • Signal wire shorted to supply
    • Sensor failed high

    Checks

    1. 1Unplug the travel press sensor rh and measure the signal wire for voltage.
    2. 2Test steps: see VSP001-03.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat VSP013-04Travel press. sensor(rh), voltage below normal

    Travel press. sensor(rh), voltage below normal: same fault as VSP001-04 (the voltage is below its normal range), here on the travel press sensor rh.· Shorted low
    Check soon

    Causes

    • Signal wire shorted to ground
    • Supply or sensor wire open

    Checks

    1. 1Measure the 5 V reference and the signal wire to ground at the travel press sensor rh plug.
    2. 2Test steps: see VSP001-04.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat VSP014-03Swing press. sensor, voltage above normal

    Swing press. sensor, voltage above normal: same fault as VSP001-03 (the voltage is above its normal range), here on the swing press sensor.· Shorted high
    Check soon

    Causes

    • Signal wire shorted to supply
    • Sensor failed high

    Checks

    1. 1Unplug the swing press sensor and measure the signal wire for voltage.
    2. 2Test steps: see VSP001-03.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat VSP014-04Swing press. sensor, voltage below normal

    Swing press. sensor, voltage below normal: same fault as VSP001-04 (the voltage is below its normal range), here on the swing press sensor.· Shorted low
    Check soon

    Causes

    • Signal wire shorted to ground
    • Supply or sensor wire open

    Checks

    1. 1Measure the 5 V reference and the signal wire to ground at the swing press sensor plug.
    2. 2Test steps: see VSP001-04.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat VSP015-03Att(option) press. sensor, voltage above normal

    Att(option) press. sensor, voltage above normal: same fault as VSP001-03 (the voltage is above its normal range), here on the att option press sensor.· Shorted high
    Check soon

    Causes

    • Signal wire shorted to supply
    • Sensor failed high

    Checks

    1. 1Unplug the att option press sensor and measure the signal wire for voltage.
    2. 2Test steps: see VSP001-03.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat VSP015-04Att(option) press. sensor, voltage below normal

    Att(option) press. sensor, voltage below normal: same fault as VSP001-04 (the voltage is below its normal range), here on the att option press sensor.· Shorted low
    Check soon

    Causes

    • Signal wire shorted to ground
    • Supply or sensor wire open

    Checks

    1. 1Measure the 5 V reference and the signal wire to ground at the att option press sensor plug.
    2. 2Test steps: see VSP001-04.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat VSP016-03Attachment 2 press. sensor, voltage above normal

    Attachment 2 press. sensor, voltage above normal: same fault as VSP001-03 (the voltage is above its normal range), here on the attachment 2 press sensor.· Shorted high
    Check soon

    Causes

    • Signal wire shorted to supply
    • Sensor failed high

    Checks

    1. 1Unplug the attachment 2 press sensor and measure the signal wire for voltage.
    2. 2Test steps: see VSP001-03.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat VSP016-04Attachment 2 press. sensor, voltage below normal

    Attachment 2 press. sensor, voltage below normal: same fault as VSP001-04 (the voltage is below its normal range), here on the attachment 2 press sensor.· Shorted low
    Check soon

    Causes

    • Signal wire shorted to ground
    • Supply or sensor wire open

    Checks

    1. 1Measure the 5 V reference and the signal wire to ground at the attachment 2 press sensor plug.
    2. 2Test steps: see VSP001-04.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat VSP017-03Option pedal 1 press. sensor, voltage above normal

    Option pedal 1 press. sensor, voltage above normal: same fault as VSP001-03 (the voltage is above its normal range), here on the option pedal 1 press sensor.· Shorted high
    Check soon

    Causes

    • Signal wire shorted to supply
    • Sensor failed high

    Checks

    1. 1Unplug the option pedal 1 press sensor and measure the signal wire for voltage.
    2. 2Test steps: see VSP001-03.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat VSP017-04Option pedal 1 press. sensor, voltage below normal

    Option pedal 1 press. sensor, voltage below normal: same fault as VSP001-04 (the voltage is below its normal range), here on the option pedal 1 press sensor.· Shorted low
    Check soon

    Causes

    • Signal wire shorted to ground
    • Supply or sensor wire open

    Checks

    1. 1Measure the 5 V reference and the signal wire to ground at the option pedal 1 press sensor plug.
    2. 2Test steps: see VSP001-04.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat VSP018-03Option pedal 2 press. sensor, voltage above normal

    Option pedal 2 press. sensor, voltage above normal: same fault as VSP001-03 (the voltage is above its normal range), here on the option pedal 2 press sensor.· Shorted high
    Check soon

    Causes

    • Signal wire shorted to supply
    • Sensor failed high

    Checks

    1. 1Unplug the option pedal 2 press sensor and measure the signal wire for voltage.
    2. 2Test steps: see VSP001-03.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat VSP018-04Option pedal 2 press. sensor, voltage below normal

    Option pedal 2 press. sensor, voltage below normal: same fault as VSP001-04 (the voltage is below its normal range), here on the option pedal 2 press sensor.· Shorted low
    Check soon

    Causes

    • Signal wire shorted to ground
    • Supply or sensor wire open

    Checks

    1. 1Measure the 5 V reference and the signal wire to ground at the option pedal 2 press sensor plug.
    2. 2Test steps: see VSP001-04.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

Shared checks

Checks, in order

  1. 1Compare the sensor reading on the service screen with a gauge at the matching test port.
  2. 2Measure the 5 V supply and ground at the sensor plug with the key on.
  3. 3Check the connector for water and bent pins, then reseat it.
  4. 4Check the signal wire for a short to ground or to supply with the plug off.
  5. 5Replace the sensor only after the wiring and the real pressure are confirmed good.

Causes

  • Sensor connector corroded or a pin backed out
  • Wiring chafed
  • Real hydraulic pressure problem behind the signal
  • Sensor failed

Most common here: shorted low (18 of 39)

Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

When to stop

You'll notice: The machine loses power or smoothness in a function, or a hydraulic pressure warning appears.

Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.