The remaining E145 and E165 circuits: inching and speed relays, thumb wheels and dial, the parking brake pressure sensor, the vehicle speed sensor and spare inputs, and the breaker, option and relief valves. A code names the circuit.

FaultCheckVSV001-05Bobcat · E145/E165 inputs, relays and attachment valves
Code shows hereFAULTVSV001-05

Where this code shows

On touchscreen R-series machines, touch the screen and pick Service Codes from the menu.

What do these codes mean?

Bobcat codes VSV001-05 to VS5005-04 are all about the e145/E165 inputs, relays and attachment valves. The most common failure type is shorted low (13 of 26); none needs an immediate stop. Start with this check: swap the relay with an identical one and see whether the code moves to the other circuit.

How urgent are they?

None of the 26 codes here means stop now; all 26 can wait until the shift ends, but find the cause before the next one.

  • Check soon26

What should I check first?

Swap the relay with an identical one and see whether the code moves to the other circuit.

Shared checks

26 of 26

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Bobcat VSV001-05Breaker operating s/v, current below normal

    The controller measured less current than expected through the solenoid valve while commanding it, which usually means an open wire, a poor connection or a coil that has failed open, so the relay does not respond, so travel speed changes are lost.· Open circuit
    Check soon

    Causes

    • Coil open or very high resistance
    • Connector pin backed out or corroded at the relay socket
    • Wire broken near a bend
    • Controller output weak

    Checks

    1. 1Measure the resistance of the relay and its socket with the plug off; an open or very high reading confirms the part.
    2. 2Check the solenoid valve connector at the relay socket for corrosion and for pins pushed back in the shell.
    3. 3Check the wire for resistance between the controller and the plug while flexing the harness.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat VSV001-06Breaker operating s/v, current above normal

    The controller measured more current than expected through the solenoid valve while commanding it, which points to a shorted coil or a wire shorted to ground, and the relay does not respond, so travel speed changes are lost until it is cleared.· Shorted low
    Check soon

    Causes

    • Coil shorted between turns
    • Wire chafed to ground at the relay socket
    • Water in the connector
    • Wrong part fitted

    Checks

    1. 1Measure the resistance of the relay and its socket with the plug off and compare it with a matching part.
    2. 2Test the solenoid valve output wire to ground with the plug off for a short.
    3. 3Look at the harness at the relay socket for chafing that shorts to ground only when the machine moves.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat VSV002-05Relief press. up S/V (b), current below normal

    Relief press. up S/V (b), current below normal: same fault as VSV001-05 (the controller measured too little current), here on the relief press up s v b.· Open circuit
    Check soon

    Causes

    • Coil open or very high resistance
    • Connector pin backed out or corroded

    Checks

    1. 1Measure the resistance of the relief press up s v b with the plug off and check its connector.
    2. 2Test steps: see VSV001-05.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat VSV002-06Relief press. up S/V (b), current above normal

    Relief press. up S/V (b), current above normal: same fault as VSV001-06 (the controller measured too much current), here on the relief press up s v b.· Shorted low
    Check soon

    Causes

    • Coil shorted between turns
    • Wire chafed to ground

    Checks

    1. 1Test the relief press up s v b wire to ground and measure the coil resistance.
    2. 2Test steps: see VSV001-06.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat VSE003-03Vehicle speed sensor, voltage above normal

    Vehicle speed sensor, voltage above normal: same fault as VS5004-03 (the voltage is above its normal range), here on the vehicle speed sensor.· Shorted high
    Check soon

    Causes

    • Signal wire shorted to supply
    • Sensor failed high

    Checks

    1. 1Unplug the vehicle speed sensor and measure the signal wire for voltage.
    2. 2Test steps: see VS5004-03.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat VSE003-04Vehicle speed sensor, voltage below normal

    Vehicle speed sensor, voltage below normal: same fault as VS5004-04 (the voltage is below its normal range), here on the vehicle speed sensor.· Shorted low
    Check soon

    Causes

    • Signal wire shorted to ground
    • Supply or sensor wire open

    Checks

    1. 1Measure the 5 V reference and the signal wire to ground at the vehicle speed sensor plug.
    2. 2Test steps: see VS5004-04.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat VRY004-05Inching relay, current below normal

    The controller measured less current than expected through the inching relay while commanding it, which usually means an open wire, a poor connection or a coil that has failed open, so the relay does not respond, so travel speed changes are lost.· Open circuit
    Check soon

    Causes

    • Coil open or very high resistance
    • Connector pin backed out or corroded at the relay socket
    • Wire broken near a bend
    • Controller output weak

    Checks

    1. 1Measure the resistance of the relay and its socket with the plug off; an open or very high reading confirms the part.
    2. 2Check the inching relay connector at the relay socket for corrosion and for pins pushed back in the shell.
    3. 3Check the wire for resistance between the controller and the plug while flexing the harness.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat VRY004-06Inching relay, current above normal

    The controller measured more current than expected through the inching relay while commanding it, which points to a shorted coil or a wire shorted to ground, and the relay does not respond, so travel speed changes are lost until it is cleared.· Shorted low
    Check soon

    Causes

    • Coil shorted between turns
    • Wire chafed to ground at the relay socket
    • Water in the connector
    • Wrong part fitted

    Checks

    1. 1Measure the resistance of the relay and its socket with the plug off and compare it with a matching part.
    2. 2Test the inching relay output wire to ground with the plug off for a short.
    3. 3Look at the harness at the relay socket for chafing that shorts to ground only when the machine moves.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat VSE005-03Spare speed, voltage above normal

    Spare speed, voltage above normal: same fault as VS5004-03 (the voltage is above its normal range), here on the spare speed.· Shorted high
    Check soon

    Causes

    • Signal wire shorted to supply
    • Sensor failed high

    Checks

    1. 1Unplug the spare speed and measure the signal wire for voltage.
    2. 2Test steps: see VS5004-03.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat VSE005-04Spare speed, voltage below normal

    Spare speed, voltage below normal: same fault as VS5004-04 (the voltage is below its normal range), here on the spare speed.· Shorted low
    Check soon

    Causes

    • Signal wire shorted to ground
    • Supply or sensor wire open

    Checks

    1. 1Measure the 5 V reference and the signal wire to ground at the spare speed plug.
    2. 2Test steps: see VS5004-04.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat VRY005-05Low speed relay, current below normal

    The controller measured less current than expected through the sensor input while commanding it, which usually means an open wire, a poor connection or a coil that has failed open, so the relay does not respond, so travel speed changes are lost.· Open circuit
    Check soon

    Causes

    • Coil open or very high resistance
    • Connector pin backed out or corroded at the relay socket
    • Wire broken near a bend
    • Controller output weak

    Checks

    1. 1Measure the resistance of the relay and its socket with the plug off; an open or very high reading confirms the part.
    2. 2Check the sensor input connector at the relay socket for corrosion and for pins pushed back in the shell.
    3. 3Check the wire for resistance between the controller and the plug while flexing the harness.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat VRY005-06Low speed relay, current above normal

    The controller measured more current than expected through the sensor input while commanding it, which points to a shorted coil or a wire shorted to ground, and the relay does not respond, so travel speed changes are lost until it is cleared.· Shorted low
    Check soon

    Causes

    • Coil shorted between turns
    • Wire chafed to ground at the relay socket
    • Water in the connector
    • Wrong part fitted

    Checks

    1. 1Measure the resistance of the relay and its socket with the plug off and compare it with a matching part.
    2. 2Test the sensor input output wire to ground with the plug off for a short.
    3. 3Look at the harness at the relay socket for chafing that shorts to ground only when the machine moves.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat VSE006-03Spare, voltage above normal

    Spare, voltage above normal: same fault as VS5004-03 (the voltage is above its normal range), here on the spare.· Shorted high
    Check soon

    Causes

    • Signal wire shorted to supply
    • Sensor failed high

    Checks

    1. 1Unplug the spare and measure the signal wire for voltage.
    2. 2Test steps: see VS5004-03.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat VSE006-04Spare, voltage below normal

    Spare, voltage below normal: same fault as VS5004-04 (the voltage is below its normal range), here on the spare.· Shorted low
    Check soon

    Causes

    • Signal wire shorted to ground
    • Supply or sensor wire open

    Checks

    1. 1Measure the 5 V reference and the signal wire to ground at the spare plug.
    2. 2Test steps: see VS5004-04.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat VRY006-05High speed relay, current below normal

    High speed relay, current below normal: same fault as VRY005-05 (the controller measured too little current), here on the high speed relay.· Open circuit
    Check soon

    Causes

    • Coil open or very high resistance
    • Connector pin backed out or corroded

    Checks

    1. 1Measure the resistance of the high speed relay with the plug off and check its connector.
    2. 2Test steps: see VRY005-05.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat VRY006-06High speed relay, current above normal

    High speed relay, current above normal: same fault as VRY005-06 (the controller measured too much current), here on the high speed relay.· Shorted low
    Check soon

    Causes

    • Coil shorted between turns
    • Wire chafed to ground

    Checks

    1. 1Test the high speed relay wire to ground and measure the coil resistance.
    2. 2Test steps: see VRY005-06.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat VSV007-05Option safety s/v, current below normal

    Option safety s/v, current below normal: same fault as VSV001-05 (the controller measured too little current), here on the option safety s v.· Open circuit
    Check soon

    Causes

    • Coil open or very high resistance
    • Connector pin backed out or corroded

    Checks

    1. 1Measure the resistance of the option safety s v with the plug off and check its connector.
    2. 2Test steps: see VSV001-05.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat VSV007-06Option safety s/v, current above normal

    Option safety s/v, current above normal: same fault as VSV001-06 (the controller measured too much current), here on the option safety s v.· Shorted low
    Check soon

    Causes

    • Coil shorted between turns
    • Wire chafed to ground

    Checks

    1. 1Test the option safety s v wire to ground and measure the coil resistance.
    2. 2Test steps: see VSV001-06.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat VS5001-03Thumb wheel (rh), voltage above normal

    The controller reads the dial input voltage above its normal range, so the sensor signal is shorted high or the sensor has failed, and the setting made with the dial or wheel is ignored.· Shorted high
    Check soon

    Causes

    • Signal wire shorted to supply
    • Sensor failed high
    • Open ground at the sensor

    Checks

    1. 1Unplug the dial input and measure the signal wire; voltage with the sensor removed shows a short to supply.
    2. 2Check the sensor ground at the plug.
    3. 3Measure the sensor 5 V reference.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat VS5001-04Thumb wheel (rh), voltage below normal

    The controller reads the dial input voltage below its normal range, so the signal wire is shorted to ground, the supply is open or the sensor failed low, and the setting made with the dial or wheel is ignored.· Shorted low
    Check soon

    Causes

    • Signal wire shorted to ground
    • Supply or sensor wire open
    • Sensor failed low

    Checks

    1. 1Measure the sensor 5 V reference at the dial input plug.
    2. 2Unplug the dial input and measure the signal wire to ground.
    3. 3Check the connector for a backed-out pin.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat VS5002-03Thumb wheel (lh), voltage above normal

    Thumb wheel (lh), voltage above normal: same fault as VS5001-03 (the voltage is above its normal range), here on the thumb wheel lh.· Shorted high
    Check soon

    Causes

    • Signal wire shorted to supply
    • Sensor failed high

    Checks

    1. 1Unplug the thumb wheel lh and measure the signal wire for voltage.
    2. 2Test steps: see VS5001-03.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat VS5002-04Thumb wheel (lh), voltage below normal

    Thumb wheel (lh), voltage below normal: same fault as VS5001-04 (the voltage is below its normal range), here on the thumb wheel lh.· Shorted low
    Check soon

    Causes

    • Signal wire shorted to ground
    • Supply or sensor wire open

    Checks

    1. 1Measure the 5 V reference and the signal wire to ground at the thumb wheel lh plug.
    2. 2Test steps: see VS5001-04.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat VS5004-03Parking brake press. sensor, voltage above normal

    The controller reads the sensor input voltage above its normal range, so the sensor signal is shorted high or the sensor has failed, and the relay does not respond, so travel speed changes are lost.· Shorted high
    Check soon

    Causes

    • Signal wire shorted to supply
    • Sensor failed high
    • Open ground at the sensor

    Checks

    1. 1Unplug the sensor input and measure the signal wire; voltage with the sensor removed shows a short to supply.
    2. 2Check the sensor ground at the plug.
    3. 3Measure the sensor 5 V reference.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat VS5004-04Parking brake press. sensor, voltage below normal

    The controller reads the sensor input voltage below its normal range, so the signal wire is shorted to ground, the supply is open or the sensor failed low, and the relay does not respond, so travel speed changes are lost.· Shorted low
    Check soon

    Causes

    • Signal wire shorted to ground
    • Supply or sensor wire open
    • Sensor failed low

    Checks

    1. 1Measure the sensor 5 V reference at the sensor input plug.
    2. 2Unplug the sensor input and measure the signal wire to ground.
    3. 3Check the connector for a backed-out pin.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat VS5005-03Dial, voltage above normal

    Dial, voltage above normal: same fault as VS5001-03 (the voltage is above its normal range), here on the dial.· Shorted high
    Check soon

    Causes

    • Signal wire shorted to supply
    • Sensor failed high

    Checks

    1. 1Unplug the dial and measure the signal wire for voltage.
    2. 2Test steps: see VS5001-03.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat VS5005-04Dial, voltage below normal

    Dial, voltage below normal: same fault as VS5001-04 (the voltage is below its normal range), here on the dial.· Shorted low
    Check soon

    Causes

    • Signal wire shorted to ground
    • Supply or sensor wire open

    Checks

    1. 1Measure the 5 V reference and the signal wire to ground at the dial plug.
    2. 2Test steps: see VS5001-04.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

Shared checks

Checks, in order

  1. 1Swap the relay with an identical one and see whether the code moves to the other circuit.
  2. 2Turn the thumb wheels and dial through their range and watch the service screen value change smoothly.
  3. 3Check the vehicle speed sensor air gap and its connector for metal debris.
  4. 4Measure the valve coil resistance with the plug off for breaker, option and relief valves.
  5. 5Check the parking brake pressure sensor connector and the brake pressure it reports.

Causes

  • Relay stuck or its socket loose
  • Dial or wheel contact worn
  • Speed sensor gap or connector fault
  • Valve coil failed

Most common here: shorted low (13 of 26)

Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

When to stop

You'll notice: Travel speed changes are wrong, a dial setting is ignored, or the breaker or option function fails.

Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.