JLG Controller, CAN bus, software, configuration and reference voltage fault codes

This family is the control system itself: CAN bus communication between the ground and platform modules, software and data version mismatches, machine configuration and calibration, the sensor reference voltage, and module hardware failures. They point at the electronics rather than a single part.

FaultStop6-6JLG · Controller, CAN bus, software, configuration and reference voltage
Code shows hereFAULT6-6

Where this code shows

Turn the key on and watch the fault lamp or platform display.

What do these codes mean?

JLG codes 6-6 to 9986 are all about the controller, CAN bus, software, configuration and reference voltage. The most common failure type is part or controller (9 of 22); 14 need an immediate stop. Start with this check: read the module and software versions in the analyzer.

How urgent are they?

14 of 22 codes here mean stop now; the other 8 can wait until the shift ends, but find the cause before the next one.

  • Stop now14
  • Check soon8

What should I check first?

Read the module and software versions in the analyzer

Shared checks

22 of 22

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • CAN bus failure6 codes

    • JLG 662CAN bus failure: Platform module

      The ground module has lost communication with the platform module over the CAN bus.· Lost message
      Stop now

      Causes

      • Broken or chafed CAN wires in the cable to the platform
      • Corroded platform connector
      • Platform module failed
      • CAN termination or T fitting damaged at the ground station
      • Power or ground missing at the platform module

      Checks

      1. 1Measure CAN resistance at the T fitting in the ground station (a complete bus is approximately 60 ohms per the manual)
      2. 2Inspect connectors at both ends of the CAN harness and the cable run to the platform
      3. 3Check power and ground at the platform module
      4. 4Wiggle the CAN harness while watching for the fault to appear
      5. 5Swap in a known good platform module to isolate a module failure
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • JLG 663CAN bus failure: Load sensing system module

      The load sensing system (LSS) module is not communicating on the CAN bus, so overload protection may be disabled and platform loading limits are not monitored.· Lost message
      Check soon

      Causes

      • LSS module power or ground missing
      • CAN wiring fault between the LSS and the ground module
      • LSS module failed
      • Connector corrosion at the LSS module

      Checks

      1. 1Check the fuse and measure power and ground at the LSS module connector
      2. 2Check the CAN wires at its connector for continuity and shorts
      3. 3Measure CAN bus resistance at the T fitting in the ground station
      4. 4Reseat the LSS module connectors and look for water or corrosion on the pins
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • JLG 666CAN bus failure: Engine controller

      The machine controller has lost communication with the engine controller over CAN, so engine data and control are not available.· Lost message
      Stop now

      Causes

      • CAN wire to the engine controller broken or shorted
      • Engine controller without power or ground

      Checks

      1. 1Check power, ground and the CAN wires at the engine controller
      2. 2Check the connectors on the CAN link
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • JLG 6613CAN bus failure: Excessive CAN bus errors

      The CAN bus is seeing too many errors, which points to damaged wiring, a poor connection or a module corrupting traffic.· Lost message
      Check soon

      Causes

      • Damaged or chafed CAN wires
      • A module loading or corrupting the bus

      Checks

      1. 1Check the CAN wiring and connectors
      2. 2Disconnect modules one at a time to find the one causing errors
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • JLG 6622CAN bus failure: TCU module

      The controller has lost communication with the TCU module, so that module is not answering on CAN.· Lost message
      Check soon

      Causes

      • TCU module without power or ground
      • CAN wiring to the TCU damaged

      Checks

      1. 1Check power, ground and CAN wires at the TCU
      2. 2Check the connector and module
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • JLG 6629CAN bus failure: Telematics CAN bus loading too high

      The telematics unit is loading the CAN bus too heavily, which can disturb communication between modules.· Lost message
      Check soon

      Causes

      • Telematics unit sending too much traffic
      • Faulty telematics unit or wiring

      Checks

      1. 1Unplug the telematics unit and see whether the error stops
      2. 2Replace or reconfigure the unit
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • EEPROM failure1 code

    • JLG 998EEPROM failure: Check all settings

      The controller found a failure in its stored memory, so settings may be wrong or lost and must all be checked.· Part or controller
      Stop now

      Causes

      • Memory corrupted by a supply glitch
      • Module memory failing

      Checks

      1. 1Check and reload all settings
      2. 2Replace the module if the failure returns
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Functions locked out4 codes

    • JLG 9910Functions locked out: Platform module software version improper

      The platform module reports a software version that does not match the machine or the other modules, so functions are locked out until it is updated.· Part or controller
      Stop now

      Causes

      • Platform module swapped from another machine with different software
      • Platform module update interrupted partway through

      Checks

      1. 1Read the platform module software version in the analyzer and compare with the required level for the machine
      2. 2Reload the correct platform software, cycle EMS and check the lockout clears
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

    • JLG 9911Functions locked out: LSS module software version improper

      The load sensing module reports a software version that does not match the machine, so functions are locked out until it is updated.· Part or controller
      Stop now

      Causes

      • Load sensing module fitted new without the software for this machine
      • Load sensing module update left unfinished

      Checks

      1. 1Read the load sensing module version in the analyzer and compare with the required level for the machine
      2. 2Load the correct software into that module and cycle EMS
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

    • JLG 9924Functions locked out: Machine not configured

      The machine has not been configured, so functions are locked out until the model and settings are entered.· Other
      Stop now

      Causes

      • New or replaced module not configured
      • Configuration lost

      Checks

      1. 1Enter the machine configuration in the analyzer
      2. 2Cycle EMS
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • JLG 9979Functions locked out: Ground module software version improper

      The ground module reports a software version that does not match the machine, so functions are locked out until it is updated.· Part or controller
      Stop now

      Causes

      • Ground module replaced with a unit carrying older or foreign software
      • Ground module software changed without updating the platform module

      Checks

      1. 1Read the ground module version in the analyzer and compare with the platform module
      2. 2Reload the correct ground module software, then cycle EMS and recheck
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Ground module failure1 code

    • JLG 9921Ground module failure: High side driver cutout faulty

      The ground module reports an internal hardware fault in the high-side driver cutout.· Part or controller
      Stop now

      Causes

      • Ground module internal failure in the high-side driver cutout
      • A shorted output that damaged the driver
      • Supply voltage spike damaging the module
      • Loose battery or ground feed to the module

      Checks

      1. 1Cycle the EMS and see whether the fault returns
      2. 2Check the supply and ground to the ground module are tight and clean
      3. 3Look for a shorted output or a damaged wire that could have overloaded a driver
      4. 4Check the battery and charging voltages for spikes
      5. 5Replace the ground module if the fault returns
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Platform module failure1 code

    • JLG 9922Platform module failure: HWFS code 1

      The platform module reports a hardware failsafe fault, code 1, which is an internal failure.· Part or controller
      Stop now

      Causes

      • Platform module internal failure
      • A shorted platform output that damaged a driver
      • Loose supply or ground to the platform module
      • Water in the platform box

      Checks

      1. 1Cycle the EMS and see whether the fault returns
      2. 2Check supply and ground at the platform module connector
      3. 3Inspect the platform box for water and burnt components
      4. 4Check platform wiring for an output shorted to ground or supply
      5. 5Replace the platform module if the fault returns
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Machine configuration out of range1 code

    • JLG 9949Machine configuration out of range: Check all settings

      One or more machine settings are outside their allowed range, so the configuration must be checked.· Other
      Check soon

      Causes

      • Setting entered wrongly
      • Memory corrupted

      Checks

      1. 1Check every setting against the machine model
      2. 2Reload the correct personality
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Other codes8 codes

    • JLG 6-6CAN bus failure

      The ground module and platform module are no longer exchanging CAN messages, usually from wiring trouble between the platform and ground station.· Lost message
      Stop now

      Causes

      • CAN wires chafed or broken in the boom cable track or at the turntable
      • Corroded CAN connector at the platform or ground module
      • Open terminating resistor or damaged T fitting at the ground station
      • Low supply voltage causing a module reset
      • Failed platform or ground module

      Checks

      1. 1Measure the resistance across CAN high and low at the T fitting in the ground station; about 60 ohms means a complete bus
      2. 2Check each module's own circuit separately; about 120 ohms each
      3. 3Inspect and reseat the platform and ground module connectors
      4. 4Check battery voltage and the module ground connection
      5. 5Swap in a known good platform module to isolate
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • JLG 9-9Controller (module) problem

      An internal fault in the ground or platform module or its stored data: EEPROM failure, reference voltage out of range, VLow FET failure, hardware self test code, or software version problem.· Part or controller
      Stop now

      Causes

      • EEPROM corrupt or configuration reset to defaults
      • 7 V sensor reference shorted or overloaded by a failed sensor
      • Module hardware failure
      • Platform and ground module software versions that do not match
      • Low or noisy supply voltage resetting the module

      Checks

      1. 1Read the Help message to identify which 9-9 variant it is
      2. 2Cycle EMS and recheck whether the fault returns
      3. 3Re-enter the machine configuration digits and recalibrate if the analyzer asks for it
      4. 4Unplug sensors one at a time to see if a short is pulling the reference down
      5. 5Replace the named module if the fault keeps returning
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

    • JLG 9919Ground sensor reference voltage out of range

      The sensor reference voltage at the ground module is out of range.· Other
      Stop now

      Causes

      • Short on a sensor supply wire dragging the 7 V reference down
      • Overloaded reference from a failed sensor sharing the feed
      • Ground module failure
      • Water in a connector on the shared feed

      Checks

      1. 1Measure the sensor reference at the ground module and compare with the platform module
      2. 2Unplug the sensors one at a time to see if the reference recovers and find the short
      3. 3Inspect harnesses and connectors on the shared feed for chafing and water
      4. 4Check each sensor on the shared feed for an internal short to ground
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • JLG 9920Platform sensor ref voltage out of range

      The reference voltage the platform module supplies to its sensors is outside its window, so platform sensors read wrongly.· Other
      Stop now

      Causes

      • Short on a platform sensor circuit
      • Platform module reference fault

      Checks

      1. 1Measure the reference at the platform module
      2. 2Unplug platform sensors one at a time to find a short
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • JLG 9927Ground module constant data update required

      The ground module has the right software but its constant data for the machine model is out of date, so it will not run normally until the data is reloaded.· Part or controller
      Check soon

      Causes

      • New ground module software loaded without the matching constant data
      • Constant data in the ground module corrupted after a power loss during loading

      Checks

      1. 1Load the constant data set for the machine model into the ground module
      2. 2Cycle EMS and confirm the module accepts the data without the lockout returning
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

    • JLG 9944Current feedback gains out of range

      The stored current feedback gains are outside their allowed range, so coil current readings cannot be trusted.· Other
      Check soon

      Causes

      • Calibration data lost or corrupted
      • Module fault

      Checks

      1. 1Recalibrate the current feedback
      2. 2Replace the module if the gains stay out of range
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • JLG 9945Current feedback calibration checksum incorrect

      The checksum on the stored current feedback calibration is wrong, so the calibration cannot be trusted.· Part or controller
      Check soon

      Causes

      • Calibration corrupted
      • Module memory fault

      Checks

      1. 1Repeat the current feedback calibration
      2. 2Replace the module if it will not hold
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

    • JLG 9986Ground module Vlow FET failure

      A power transistor in the ground module has failed its check, which means the module itself has an internal hardware fault.· Other
      Stop now

      Causes

      • Internal transistor failure in the ground module
      • Output short damaged the module

      Checks

      1. 1Cycle EMS and see whether the code returns
      2. 2Replace the ground module if it persists
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

Shared checks

Checks, in order

  1. 1Read the module and software versions in the analyzer
  2. 2Check the CAN wiring, connectors and terminating resistors
  3. 3Reload the correct software and constant data, then set configuration and calibration
  4. 4Check the sensor reference voltage at the module
  5. 5Replace the module if it will not accept the software

Causes

  • CAN wiring damaged or terminated wrongly
  • Module software or data not matching the machine
  • Machine configuration or calibration not set
  • Module hardware failed

Most common here: part or controller (9 of 22)

Check power and ground at the module connector with the key on, then its fuses.

When to stop

You'll notice: The machine locks out, will not run or loses communication, and the code names the module or bus involved.

Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.