JLG · Communication
JLG Fault Code 662
CAN bus failure - platform module
What does JLG code 662 mean?
The ground module has lost communication with the platform module over the CAN bus. Platform functions stop and the machine may shut down. Urgency: stop now - shut down and fix before working on. Check first: measure CAN resistance at the T fitting in the ground station (a complete bus is approximately 60 ohms per the manual).
Can I keep running with it?
Stop now
Shut down and fix before working on. Running on risks damage or the machine locks out.
What should I check first?
Measure CAN resistance at the T fitting in the ground station (a complete bus is approximately 60 ohms per the manual)
Then 4 more checksWhere this code shows
Turn the key on and watch the fault lamp or platform display.
Checks
0 of 5 done
Causes
- Broken or chafed CAN wires in the cable to the platform
- Corroded platform connector
- Platform module failed
- CAN termination or T fitting damaged at the ground station
1 more causeFewer causes
- Power or ground missing at the platform module
How it failed
You'll notice: Platform functions stop and the machine may shut down because the ground module has lost the platform module on the CAN bus.
Lost messageRead from how the source describes the code
A module stopped hearing another on the data link, or the data came late or garbled.
- Meter test
- Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
- Good result
- About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
When to stop
Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Same part, other failures: Controller, CAN bus, software, configuration and reference voltage
6 other codes on this part are also lost message (6-6, 663, 666, 6613 and more). When they show together, start at the wiring and connector they share.
- 6-6CAN bus failureLost messageStop now
- 9-9Controller (module) problemPart or controllerStop now
- 662CAN bus failure - platform moduleLost messageStop now
- 663CAN bus failure - load sensing system moduleLost messageCheck soon
- 666CAN bus failure - engine controllerLost messageStop now
- 998EEPROM failure - check all settingsPart or controllerStop now
- 6613CAN bus failure - excessive CAN bus errorsLost messageCheck soon
- 6622CAN bus failure - TCU moduleLost messageCheck soon
- 6629CAN bus failure - telematics CAN bus loading too highLost messageCheck soon
Show the other 13 codesHide the other codes
- 9910Functions locked out - platform module software version improperPart or controllerStop now
- 9911Functions locked out - LSS module software version improperPart or controllerStop now
- 9919Ground sensor reference voltage out of rangeOtherStop now
- 9920Platform sensor ref voltage out of rangeOtherStop now
- 9921Ground module failure - high side driver cutout faultyPart or controllerStop now
- 9922Platform module failure - HWFS code 1Part or controllerStop now
- 9924Functions locked out - machine not configuredOtherStop now
- 9927Ground module constant data update requiredPart or controllerCheck soon
- 9944Current feedback gains out of rangeOtherCheck soon
- 9945Current feedback calibration checksum incorrectPart or controllerCheck soon
- 9949Machine configuration out of range - check all settingsOtherCheck soon
- 9979Functions locked out - ground module software version improperPart or controllerStop now
- 9986Ground module Vlow FET failureOtherStop now
Related on Equipments Finder
Source
JLG 600S/660SJ Service and Maintenance Manual 3121298, section 6 (Table 6-8 Fault Code List)
This source lists 662 and its meaning. The guidance on this page is general, not taken from it.
The source covers: JLG 600S, 600SJ, 660SJ with newer module software; same DTC scheme on other JLG Control System booms, confirm in your manual.
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.