CAN bus failure - platform module

What does JLG code 662 mean?

The ground module has lost communication with the platform module over the CAN bus. Platform functions stop and the machine may shut down. Urgency: stop now - shut down and fix before working on. Check first: measure CAN resistance at the T fitting in the ground station (a complete bus is approximately 60 ohms per the manual).

FaultStop662JLG · Communication

Can I keep running with it?

Stop now

Shut down and fix before working on. Running on risks damage or the machine locks out.

What should I check first?

Measure CAN resistance at the T fitting in the ground station (a complete bus is approximately 60 ohms per the manual)

Then 4 more checks
Code shows hereFAULT662

Where this code shows

Turn the key on and watch the fault lamp or platform display.

Checks

0 of 5 done

Causes

  • Broken or chafed CAN wires in the cable to the platform
  • Corroded platform connector
  • Platform module failed
  • CAN termination or T fitting damaged at the ground station
1 more cause
  • Power or ground missing at the platform module

How it failed

You'll notice: Platform functions stop and the machine may shut down because the ground module has lost the platform module on the CAN bus.

Lost messageRead from how the source describes the code

A module stopped hearing another on the data link, or the data came late or garbled.

Module AModule BCAN HCAN L120 Ω120 Ω
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.
Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good result
About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

When to stop

Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.

Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Same part, other failures: Controller, CAN bus, software, configuration and reference voltage

6 other codes on this part are also lost message (6-6, 663, 666, 6613 and more). When they show together, start at the wiring and connector they share.

Show the other 13 codes
All 22 Controller, CAN bus, software, configuration and reference voltage codes on one page

Source

JLG 600S/660SJ Service and Maintenance Manual 3121298, section 6 (Table 6-8 Fault Code List)

This source lists 662 and its meaning. The guidance on this page is general, not taken from it.

The source covers: JLG 600S, 600SJ, 660SJ with newer module software; same DTC scheme on other JLG Control System booms, confirm in your manual.

Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.