EF Logo

JLG · Controller

JLG Fault Code 9921

Ground module failure - high side driver cutout faulty

What does JLG code 9921 mean?

The ground module reports an internal hardware fault in the high-side driver cutout. Cycling power may clear it, but the fault means output drivers may not shut off properly, so the machine is locked out. Urgency: stop now - shut down and fix before working on. Check first: cycle the EMS and see whether the fault returns.

FaultStop9921JLG · Controller

Can I keep running with it?

Stop now

Shut down and fix before working on. Running on risks damage or the machine locks out.

What should I check first?

Cycle the EMS and see whether the fault returns

Then 4 more checks
Code shows hereFAULT9921

Where this code shows

Turn the key on and watch the fault lamp or platform display.

Checks

0 of 5 done

Causes

  • Ground module internal failure in the high-side driver cutout
  • A shorted output that damaged the driver
  • Supply voltage spike damaging the module
  • Loose battery or ground feed to the module

How it failed

You'll notice: The machine is locked out because the ground module reports an internal driver cutout fault, which means its outputs may not be able to switch off safely.

Part or controllerRead from how the source describes the code

The controller reports a part, module or its software as faulty or not responding.

ControllerPartSupplySignalGround?
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.
Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good result
Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

When to stop

Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.

Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Same part, other failures: Controller, CAN bus, software, configuration and reference voltage

8 other codes on this part are also part or controller (9-9, 998, 9910, 9911 and more). When they show together, start at the wiring and connector they share.

Show the other 13 codes
All 22 Controller, CAN bus, software, configuration and reference voltage codes on one page

Source

JLG 600S/660SJ Service and Maintenance Manual 3121298, section 6 (Table 6-8 Fault Code List)

This source lists 9921 and its meaning. The guidance on this page is general, not taken from it.

The source covers: JLG 600S, 600SJ, 660SJ with newer module software; same DTC scheme on other JLG Control System booms, confirm in your manual.

Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request