JLG Fault Code 6‑6

CAN bus failure

What does JLG code 6-6 mean?

The ground module and platform module are no longer exchanging CAN messages, usually from wiring trouble between the platform and ground station. Controls stop responding. Urgency: stop now - shut down and fix before working on. Check first: measure the resistance across CAN high and low at the T fitting in the ground station; about 60 ohms means a complete bus.

FaultStop6-6JLG · Communication

Can I keep running with it?

Stop now

Shut down and fix before working on. Running on risks damage or the machine locks out.

What should I check first?

Measure the resistance across CAN high and low at the T fitting in the ground station; about 60 ohms means a complete bus

Then 4 more checks
Code shows hereFAULT6-6

Where this code shows

Turn the key on and watch the fault lamp or platform display.

Checks

0 of 5 done

Causes

  • CAN wires chafed or broken in the boom cable track or at the turntable
  • Corroded CAN connector at the platform or ground module
  • Open terminating resistor or damaged T fitting at the ground station
  • Low supply voltage causing a module reset
1 more cause
  • Failed platform or ground module

How it failed

You'll notice: The platform controls stop responding because the ground and platform modules are no longer talking, and the lamp flashes 6-6.

Lost messageRead from how the source describes the code

A module stopped hearing another on the data link, or the data came late or garbled.

Module AModule BCAN HCAN L120 Ω120 Ω
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.
Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good result
About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

When to stop

Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.

Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Same part, other failures: Controller, CAN bus, software, configuration and reference voltage

6 other codes on this part are also lost message (662, 663, 666, 6613 and more). When they show together, start at the wiring and connector they share.

Show the other 13 codes
All 22 Controller, CAN bus, software, configuration and reference voltage codes on one page

Source

JLG 600S/600SJ/660SJ/600A/AJ Service and Maintenance Manual 3120840, section 6 (Tables 6-3, 6-5)

This source lists 6-6 and its meaning. The guidance on this page is general, not taken from it.

The source covers: JLG boom lifts with the JLG Control System (600S, 600SJ, 660SJ, 600A/AJ, 450A, 510A, 400S, 1200/1350SJP families).

Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.