J1939 · Aftertreatment - SCR/DEF
SPN 4363 Fault Code
Aftertreatment 1 SCR outlet gas temperature
What does SPN 4363 mean?
Exhaust temperature leaving the SCR catalyst, read by a sensor after it. The ECM uses it to check catalyst operation and thermal management. How urgent it is depends on the FMI after SPN 4363 - pick it below. Check first: under load compare the SCR outlet temperature with the SCR intake temperature; the outlet should follow with a small offset.
- SPN 4363
- Aftertreatment 1 SCR outlet gas temperature
- FMI ?
- How it failed - the number after the SPN
Can I keep running with it?
Depends on the FMI
How urgent it is depends on the FMI after SPN 4363 - pick it below.
What should I check first?
Under load compare the SCR outlet temperature with the SCR intake temperature; the outlet should follow with a small offset
Then 4 more checksWhere to read it
Connect a J1939-capable scan tool to the 9-pin diagnostic port.
Which FMI shows after SPN 4363?
You'll notice: The ECM cannot see the gas temperature leaving the SCR catalyst, so it cannot confirm the catalyst is working or limit a hot-catalyst condition.
Find the number shown after SPN 4363 on your display. 2 of them have their own page with causes and checks.
- 0SPN 4363 FMI 0: Value is above the normal range, most severe levelReal conditionCummins ISX15, Detroit DD15, Detroit DD13, Detroit DD13 Gen 5 and 1 more
- 2SPN 4363 FMI 2: Data is erratic, intermittent or incorrectErratic or implausibleCummins ISX15, Detroit DD15, Detroit DD13, Detroit DD13 Gen 5 and 1 more
- 3SPN 4363 FMI 3: Signal voltage is above normal, or the circuit is shorted to a high sourceShorted highCummins ISX15, Detroit DD15, Detroit DD13, Detroit DD13 Gen 5 and 2 more
- 4SPN 4363 FMI 4: Signal voltage is below normal, or the circuit is shorted to a low sourceShorted lowCummins ISX15, Detroit DD15, Detroit DD13, Detroit DD13 Gen 5 and 2 more
- 8SPN 4363 FMI 8: SCR outlet temperature shows a spikeErratic or implausibleDetroit DD15, Detroit DD13, Detroit DD13 Gen 5, Detroit DD15 Gen 5
- 10SPN 4363 FMI 10: The value is changing at an abnormal rateErratic or implausibleCummins ISX15
- 11SPN 4363 FMI 11: Exhaust gas temperature after the SCR catalyst is erratic or incorrectErratic or implausiblePACCAR MX-13
- 12SPN 4363 FMI 12: SCR outlet temperature sensor circuit is above normalPart or controllerCummins ISX15
- 15SPN 4363 FMI 15: Value is above the normal range, least severe levelReal conditionCummins ISX15
- 16SPN 4363 FMI 16: Value is above the normal range, moderately severe levelReal conditionCummins ISX15, PACCAR MX-13
- 19SPN 4363 FMI 19: The SCR outlet gas temperature message arrived in error over CANLost messagePACCAR MX-13
- 20SPN 4363 FMI 20: SCR temperature sensors have drifted apart, with inlet low or outlet highErratic or implausibleDetroit DD15, Detroit DD13, Detroit DD13 Gen 5, Detroit DD15 Gen 5
Checks
0 of 5 done
When to stop
Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.
How urgent SPN 4363 is depends on its FMI and whether the engine has derated. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Causes
- Reads cold: an open circuit or a short to supply in the SCR outlet temperature sensor wiring, which the ECM reads as an extremely low temperature
- Reads hot: signal wire shorted to ground or the SCR outlet temperature sensor element shorted, which the ECM reads as an extremely high temperature
- Real condition: catalyst damage or a blocked mixer changing the real outlet temperature
- Real condition: tailpipe or silencer joint leak after the SCR, cooling the gas at the sensor
1 more causeFewer causes
- Sensor: road spray and rain getting into the plug and making the reading jump
Other Aftertreatment - SCR/DEF codes
Source
Cummins ISX15 2013-2018 fault codes list (Diesel Laptops)
This list names SPN 4363 and the FMIs above for the engines it covers. The guidance on this page is general, not taken from it.
The source covers: Cummins ISX15 (2013-2018) and X15; same SPN on other J1939 engines.
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.