Deutz · Throttle and operator inputs
Deutz Fault Code SPN 91 FMI 3
Machine - Position accelerator pedal (sensor 1) - Voltage above normal or shorted to high source
What does Deutz code SPN 91 FMI 3 mean?
The EMR4 reads the accelerator pedal (sensor 1) (in the operator pedal or hand throttle assembly) above its valid voltage range. Urgency: check soon - the machine may derate or limit a function. Check first: sweep the pedal slowly through its whole travel with SerDia open and watch for dropouts or steps in the percentage.
- FMI 3
- Voltage above normal or shorted high
Can I keep running with it?
Check soon
The machine may derate or limit a function. Find the cause before the next shift.
What should I check first?
Sweep the pedal slowly through its whole travel with SerDia open and watch for dropouts or steps in the percentage
Then 3 more checksWhere to read it
Read the active and stored faults with Deutz SerDia (or the machine maker's diagnostic tool) on the engine diagnostic plug.
Checks
0 of 4 done
Causes
- Pedal connector contaminated by washdown water
- Signal wire shorted to the 5 V or battery supply
- Open ground wire to the pedal potentiometer
How it failed
You'll notice: The engine may sit at idle or run on a limited throttle.
Shorted highRead from FMI 3: voltage above normal or shorted high
The signal sits at or near the supply voltage - more than a working sensor can send.
- Meter test
- Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
- Good result
- Open circuit (OL) between them. Any low reading is the short.
When to stop
Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Same part, other failures: Operator inputs, warning lamps, shutdown requests and telemetry
3 other codes on this part are also shorted high (SPN 29 FMI 3, SPN 624 FMI 3, SPN 524087 FMI 3). When they show together, start at the wiring and connector they share.
- SPN 29 FMI 2Machine - Position accelerator pedal 2 (remote accelerator pedal 1) - Data erratic intermittent or incorrectErratic or implausibleCheck soon
- SPN 29 FMI 3Machine - Position accelerator pedal 2 (remote accelerator pedal 1) - Voltage above normal or shorted to high sourceShorted highCheck soon
- SPN 29 FMI 4Machine - Position accelerator pedal 2 (remote accelerator pedal 1) - Voltage below normal or shorted to low sourceShorted lowCheck soon
- SPN 91 FMI 3Machine - Position accelerator pedal (sensor 1) - Voltage above normal or shorted to high sourceShorted highCheck soon
- SPN 91 FMI 4Machine - Position accelerator pedal (sensor 1) - Voltage below normal or shorted to low sourceShorted lowCheck soon
- SPN 91 FMI 11Machine - Position accelerator pedal (sensor 1) - Root cause not knownOtherCheck soon
- SPN 624 FMI 3Machine - Amber warning lamp - Voltage above normal or shorted to high sourceShorted highCheck soon
- SPN 624 FMI 4Machine - Amber warning lamp - Voltage below normal or shorted to low sourceShorted lowCheck soon
- SPN 624 FMI 5Machine - Amber warning lamp - Current below normal or open circuitOpen circuitCheck soon
Show the other 13 codesHide the other codes
- SPN 624 FMI 12Machine - Amber warning lamp - Bad intelligent device or componentPart or controllerCheck soon
- SPN 1109 FMI 2Engine - Protection system requested shutdown - Data erratic intermittent or incorrectErratic or implausibleStop now
- SPN 1237 FMI 2Engine - Shutdown override switch - Data erratic intermittent or incorrectErratic or implausibleCheck soon
- SPN 523090 FMI 2Machine - Pre selection switch engine brake - Data erratic intermittent or incorrectErratic or implausibleCheck soon
- SPN 523698 FMI 11Engine - Shut down request from internal ECU monitoring - Root cause not knownOtherStop now
- SPN 523741 FMI 14Machine - CAN shut down request from engine shut down - Special instructionsLost messageCheck soon
- SPN 524087 FMI 3Engine - EAT/SCR inducement or DEF level lamp / collective error lamp (water in fuel & fuel pressure & air filter clogged) - Voltage above normal or shorted to high sourceShorted highCheck soon
- SPN 524087 FMI 4Engine - EAT/SCR inducement or DEF level lamp / collective error lamp (water in fuel & fuel pressure & air filter clogged) - Voltage below normal or shorted to low sourceShorted lowCheck soon
- SPN 524087 FMI 5Engine - EAT/SCR inducement or DEF level lamp / collective error lamp (water in fuel & fuel pressure & air filter clogged) - Current below normal or open circuitOpen circuitCheck soon
- SPN 524087 FMI 12Engine - EAT/SCR inducement or DEF level lamp / collective error lamp (water in fuel & fuel pressure & air filter clogged) - Bad intelligent device or componentPart or controllerCheck soon
- SPN 524133 FMI 2Machine - Override switch - Data erratic intermittent or incorrectErratic or implausibleCheck soon
- SPN 524285 FMI 2Machine - GPS status error - Data erratic intermittent or incorrectErratic or implausibleCheck soon
- SPN 524286 FMI 2Machine - Telemetry status error - Data erratic intermittent or incorrectErratic or implausibleCheck soon
Related on Equipments Finder
Source
DEUTZ KWP-Codes EMR4 (KWPList EMR4 DE EN, Revision 2.0), page 18
This source lists SPN 91 FMI 3 and its meaning. The guidance on this page is general, not taken from it.
The source covers: Deutz engines with the EMR4 controller (the Deutz list applies to all EMR4 engine series, e.g. TCD 2.9, 3.6, 4.1, 6.1, 7.8 as fitted in machines).
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.