EF Logo

Deutz · Throttle and operator inputs

Deutz Operator inputs, warning lamps, shutdown requests and telemetry fault codes

What the operator touches and sees. The accelerator pedal sensor (SPN 91), switch inputs from the machine, the warning lamps the EMR4 drives, shutdown requests from engine protection or the machine controller, and the GPS and telemetry status.

More about these parts

Each code names the input or output and how it failed.

FaultCheckSPN 91FMI 3Deutz · Machine - Position accelerator pedal (sensor 1)
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Read the active and stored faults with Deutz SerDia (or the machine maker's diagnostic tool) on the engine diagnostic plug.

What do these codes mean?

Deutz codes SPN 29 FMI 2 to SPN 524286 FMI 2 are all about the operator inputs, warning lamps, shutdown requests and telemetry. The most common failure type is erratic or implausible (7 of 22); 2 need an immediate stop. Start with this check: read the pedal signal in SerDia through its whole travel and look for dropouts.

How urgent are they?

2 of 22 codes here mean stop now; the other 20 can wait until the shift ends, but find the cause before the next one.

  • Stop now2
  • Check soon20

What should I check first?

Read the pedal signal in SerDia through its whole travel and look for dropouts

Shared checks

22 of 22

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Machine - Position accelerator pedal 2 (remote accelerator pedal 1)3 codes

    • Deutz SPN 29 FMI 2Machine - Position accelerator pedal 2 (remote accelerator pedal 1): Erratic reading

      The EMR4 sees the accelerator pedal 2 (remote pedal 1) (in the second or remote throttle input, such as a hand throttle or second pedal) signal erratic or not agreeing with its partner sensor.· Erratic or implausible
      Check soon

      Causes

      • Hand throttle potentiometer worn
      • Intermittent contact in the pedal connector
      • Remote throttle input wired by the machine maker through a splice that has corroded

      Checks

      1. 1Compare with the second pedal track, which should mirror it
      2. 2Find out whether your machine actually uses a second throttle input; an unused input left unplugged can log this fault
      3. 3Move the accelerator pedal 2 (remote pedal 1) slowly through its travel in SerDia and look for jumps
      4. 4Check the pedal connector for moisture and loose pins
      5. 5Move the remote or hand throttle through its travel and watch the value in SerDia for steps or dropouts
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Machine - Position accelerator pedal 2 (remote accelerator pedal 1) - Data erratic intermittent or incorrect

    • Deutz SPN 29 FMI 3Machine - Position accelerator pedal 2 (remote accelerator pedal 1): Voltage high / shorted high

      The EMR4 reads the accelerator pedal 2 (remote pedal 1) (in the second or remote throttle input, such as a hand throttle or second pedal) above its valid voltage range.· Shorted high
      Check soon

      Causes

      • Signal wire shorted to the 5 V or battery supply
      • Hand throttle potentiometer worn
      • Open ground wire to the pedal potentiometer
      • Remote throttle input wired by the machine maker through a splice that has corroded

      Checks

      1. 1Unplug the pedal and check the signal pin for a short to supply
      2. 2Move the remote or hand throttle through its travel and watch the value in SerDia for steps or dropouts
      3. 3Measure continuity of the pedal ground wire back to the EMR4
      4. 4Find out whether your machine actually uses a second throttle input; an unused input left unplugged can log this fault
      5. 5Key on: measure the supply to the accelerator pedal 2 (remote pedal 1) and check it reads 5 V
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Machine - Position accelerator pedal 2 (remote accelerator pedal 1) - Voltage above normal or shorted to high source

    • Deutz SPN 29 FMI 4Machine - Position accelerator pedal 2 (remote accelerator pedal 1): Voltage low / shorted low

      The EMR4 reads the accelerator pedal 2 (remote pedal 1) (in the second or remote throttle input, such as a hand throttle or second pedal) below its valid voltage range.· Shorted low
      Check soon

      Causes

      • Signal wire rubbed through to ground
      • 5 V supply to the pedal lost or open
      • Hand throttle potentiometer worn

      Checks

      1. 1Find out whether your machine actually uses a second throttle input; an unused input left unplugged can log this fault
      2. 2Check the harness where it flexes at the pedal or throttle lever
      3. 3Key on: measure the 5 V supply at the accelerator pedal 2 (remote pedal 1) plug
      4. 4Unplug the pedal and measure resistance from signal to ground, which should not be near zero
      5. 5Move the remote or hand throttle through its travel and watch the value in SerDia for steps or dropouts
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Machine - Position accelerator pedal 2 (remote accelerator pedal 1) - Voltage below normal or shorted to low source

  • Machine - Position accelerator pedal (sensor 1)3 codes

    • Deutz SPN 91 FMI 3Machine - Position accelerator pedal (sensor 1): Voltage high / shorted high

      The EMR4 reads the accelerator pedal (sensor 1) (in the operator pedal or hand throttle assembly) above its valid voltage range.· Shorted high
      Check soon

      Causes

      • Pedal connector contaminated by washdown water
      • Signal wire shorted to the 5 V or battery supply
      • Open ground wire to the pedal potentiometer

      Checks

      1. 1Sweep the pedal slowly through its whole travel with SerDia open and watch for dropouts or steps in the percentage
      2. 2Key on: measure the supply to the accelerator pedal (sensor 1) and check it reads 5 V
      3. 3Unplug the pedal and check the signal pin for a short to supply
      4. 4Check the machine-maker pedal connector and any splice into the engine harness, not just the engine side
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Machine - Position accelerator pedal (sensor 1) - Voltage above normal or shorted to high source

      Full page for SPN 91 FMI 3
    • Deutz SPN 91 FMI 4Machine - Position accelerator pedal (sensor 1): Voltage low / shorted low

      The EMR4 reads the accelerator pedal (sensor 1) (in the operator pedal or hand throttle assembly) below its valid voltage range.· Shorted low
      Check soon

      Causes

      • Worn track inside the pedal potentiometer
      • Pedal connector contaminated by washdown water
      • 5 V supply to the pedal lost or open
      • Signal wire rubbed through to ground

      Checks

      1. 1Key on: measure the 5 V supply at the accelerator pedal (sensor 1) plug
      2. 2Unplug the pedal and measure resistance from signal to ground, which should not be near zero
      3. 3Check the harness where it flexes at the pedal or throttle lever
      4. 4Sweep the pedal slowly through its whole travel with SerDia open and watch for dropouts or steps in the percentage
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Machine - Position accelerator pedal (sensor 1) - Voltage below normal or shorted to low source

    • Deutz SPN 91 FMI 11Machine - Position accelerator pedal (sensor 1): Root cause not known

      The EMR4 logged a fault on the accelerator pedal (sensor 1) (in the operator pedal or hand throttle assembly) but could not classify the cause.· Other
      Check soon

      Causes

      • Intermittent wiring fault
      • Worn track inside the pedal potentiometer
      • Pedal connector contaminated by washdown water

      Checks

      1. 1Measure supply, ground and signal at the pedal plug
      2. 2Check the machine-maker pedal connector and any splice into the engine harness, not just the engine side
      3. 3Sweep the pedal slowly through its whole travel with SerDia open and watch for dropouts or steps in the percentage
      4. 4Read the full SerDia list for a clearer pedal code
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Machine - Amber warning lamp4 codes

    • Deutz SPN 624 FMI 3Machine - Amber warning lamp: Voltage high / shorted high

      The EMR4 sees the output for the amber warning lamp (in the instrument panel or machine display, driven by the EMR4 output) at a voltage above normal, as if the circuit is shorted to the battery supply.· Shorted high
      Check soon

      Causes

      • Connector pin touching a live pin
      • Amber warning lamp shorted internally
      • Output wire shorted to battery positive

      Checks

      1. 1Trace the lamp wire from the EMR4 pin to the panel for damage
      2. 2Check the lamp comes on briefly at key-on as the bulb test; no bulb test points at the lamp or its wire
      3. 3With the EMR4 unplugged, measure the output wire to battery positive; it should be open
      4. 4Measure the winding or coil resistance of the part
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Machine - Amber warning lamp - Voltage above normal or shorted to high source

    • Deutz SPN 624 FMI 4Machine - Amber warning lamp: Voltage low / shorted low

      The EMR4 sees the output for the amber warning lamp (in the instrument panel or machine display, driven by the EMR4 output) at a voltage below normal, as if the circuit is shorted to ground.· Shorted low
      Check soon

      Causes

      • Output wire chafed to ground or the engine block
      • Amber warning lamp winding shorted to its housing
      • Water in the connector bridging the pins

      Checks

      1. 1Measure the winding resistance of the part and look for a very low value
      2. 2Check the lamp comes on briefly at key-on as the bulb test; no bulb test points at the lamp or its wire
      3. 3Trace the lamp wire from the EMR4 pin to the panel for damage
      4. 4With the EMR4 unplugged, measure the output wire to ground; it should not be low ohms
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Machine - Amber warning lamp - Voltage below normal or shorted to low source

    • Deutz SPN 624 FMI 5Machine - Amber warning lamp: Current low / open circuit

      The EMR4 sees too little current through the amber warning lamp (in the instrument panel or machine display, driven by the EMR4 output), which means the circuit is open.· Open circuit
      Check soon

      Causes

      • Lamp bulb or LED failed
      • Broken wire or a pin pushed out of the connector
      • Amber warning lamp winding open

      Checks

      1. 1Continuity-test each wire to the matching EMR4 pin
      2. 2Inspect both ends of the amber warning lamp circuit (EMR4 plug and part connector) for pins pushed back in the housing
      3. 3Measure the resistance across the amber warning lamp terminals: infinity means an open winding
      4. 4Check the lamp comes on briefly at key-on as the bulb test; no bulb test points at the lamp or its wire
      5. 5Trace the lamp wire from the EMR4 pin to the panel for damage
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

      Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

      Source wording:Machine - Amber warning lamp - Current below normal or open circuit

    • Deutz SPN 624 FMI 12Machine - Amber warning lamp: Bad device or component

      The EMR4 judges the amber warning lamp (in the instrument panel or machine display, driven by the EMR4 output) to be a bad device, meaning the part or its driver electronics no longer respond as a working component.· Part or controller
      Check soon

      Causes

      • Lamp bulb or LED failed
      • Internal failure of the amber warning lamp
      • Water or soot inside the part

      Checks

      1. 1Trace the lamp wire from the EMR4 pin to the panel for damage
      2. 2Check the lamp comes on briefly at key-on as the bulb test; no bulb test points at the lamp or its wire
      3. 3Measure supply voltage and ground at the amber warning lamp connector with the key on to confirm the part is powered
      4. 4Read the amber warning lamp status in SerDia and run any actuator test
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Machine - Amber warning lamp - Bad intelligent device or component

  • Engine - Protection system requested shutdown1 code

    • Deutz SPN 1109 FMI 2Engine - Protection system requested shutdown: Erratic reading

      The EMR4 reports the engine protection system requested a shutdown, with erratic data.· Erratic or implausible
      Stop now

      Causes

      • Oil pressure or coolant sensor failing
      • Intermittent connection on a protection sensor
      • Wiring fault on the protection input

      Checks

      1. 1Check the oil pressure, coolant temperature and coolant level readings in SerDia for implausible values
      2. 2Wiggle the sensor harnesses and check their connectors for loose pins
      3. 3Check the engine oil level and the coolant level by eye, because real low levels trigger protection
      4. 4Look at which protection input flickers while the engine runs
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Engine - Protection system requested shutdown - Data erratic intermittent or incorrect

  • Engine - Shutdown override switch1 code

    • Deutz SPN 1237 FMI 2Engine - Shutdown override switch: Erratic reading

      The EMR4 reports the shutdown override switch signal erratic.· Erratic or implausible
      Check soon

      Causes

      • Override switch worn or sticking
      • Intermittent connector
      • Wiring chafed

      Checks

      1. 1Operate the override switch and watch the input state in SerDia to see whether it follows the switch
      2. 2Check the override switch contacts for wear or corrosion
      3. 3Check the wiring from the switch to the EMR4 for chafing and loose terminals
      4. 4Check the machine wiring diagram to confirm which pin carries the override input
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Engine - Shutdown override switch - Data erratic intermittent or incorrect

  • Machine - Pre selection switch engine brake1 code

    • Deutz SPN 523090 FMI 2Machine - Pre selection switch engine brake: Erratic reading

      The EMR4 sees the pre selection switch engine brake (on the machine and read by the EMR4) erratic, intermittent or implausible.· Erratic or implausible
      Check soon

      Causes

      • Intermittent contact in a connector or a pin with fretting
      • Harness chafed where it moves with vibration

      Checks

      1. 1Watch the pre selection switch engine brake value in SerDia while wiggling the harness and connector and note when it jumps
      2. 2Compare it with a related value, since a lone odd reading points at the circuit or part itself
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Machine - Pre selection switch engine brake - Data erratic intermittent or incorrect

  • Engine - Shut down request from internal ECU monitoring1 code

    • Deutz SPN 523698 FMI 11Engine - Shut down request from internal ECU monitoring: Root cause not known

      The EMR4 reports a shut down request from its internal monitoring, cause not known.· Other
      Stop now

      Causes

      • A critical sensor or supply fault that triggered the shutdown
      • ECU internal monitoring failure
      • Wiring fault on an engine protection input

      Checks

      1. 1Read the full fault list and freeze frames in SerDia to see what happened just before the shutdown
      2. 2Check battery supply stability at the EMR4 connector during cranking and running
      3. 3Check the main grounds between the ECU, engine block and frame
      4. 4Look for an active protection code (oil pressure, coolant temperature, speed) that explains the shutdown
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Machine - CAN shut down request from engine shut down1 code

    • Deutz SPN 523741 FMI 14Machine - CAN shut down request from engine shut down: Special instructions

      The EMR4 flags a CAN shut down request from the engine shut down function as special instructions.· Lost message
      Check soon

      Causes

      • Machine controller commanded a shutdown
      • A machine protection condition
      • CAN fault sending a wrong request

      Checks

      1. 1Check the machine controller for its own fault codes that explain why it asked for a shutdown
      2. 2Read the shutdown reason and the freeze frame in SerDia
      3. 3Check the CAN wiring for a fault that could send a wrong shutdown request
      4. 4Check protection inputs the machine uses, such as hydraulic oil temperature or emergency stop
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Engine - EAT/SCR inducement or DEF level lamp / collective error lamp (water in fuel & fuel pressure & air filter clogged)4 codes

    • Deutz SPN 524087 FMI 3Engine - EAT/SCR inducement or DEF level lamp / collective error lamp (water in fuel & fuel pressure & air filter clogged): Voltage high / shorted high

      The EMR4 sees the output for the EAT/SCR inducement lamp or collective error lamp (in the instrument panel, driven by the EMR4) at a voltage above normal, as if the circuit is shorted to the battery supply.· Shorted high
      Check soon

      Causes

      • EAT/SCR inducement lamp or collective error lamp shorted internally
      • Connector pin touching a live pin
      • Lamp bulb or LED failed
      • Output wire shorted to battery positive

      Checks

      1. 1Measure the winding or coil resistance of the part
      2. 2Unplug the EAT/SCR inducement lamp or collective error lamp: if the code stays, the short is in the harness or the EMR4; if it clears, the part is the shorted one
      3. 3Trace the lamp wire from the EMR4 pin to the panel for damage
      4. 4With the EMR4 unplugged, measure the output wire to battery positive; it should be open
      5. 5Check that the lamp does a bulb test at key-on
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Engine - EAT/SCR inducement or DEF level lamp / collective error lamp (water in fuel & fuel pressure & air filter clogged) - Voltage above normal or shorted to high source

    • Deutz SPN 524087 FMI 4Engine - EAT/SCR inducement or DEF level lamp / collective error lamp (water in fuel & fuel pressure & air filter clogged): Voltage low / shorted low

      The EMR4 sees the output for the EAT/SCR inducement lamp or collective error lamp (in the instrument panel, driven by the EMR4) at a voltage below normal, as if the circuit is shorted to ground.· Shorted low
      Check soon

      Causes

      • Water in the connector bridging the pins
      • Output wire chafed to ground or the engine block
      • Lamp bulb or LED failed
      • EAT/SCR inducement lamp or collective error lamp winding shorted to its housing

      Checks

      1. 1Check that the lamp does a bulb test at key-on
      2. 2Measure the winding resistance of the part and look for a very low value
      3. 3With the EMR4 unplugged, measure the output wire to ground; it should not be low ohms
      4. 4Trace the lamp wire from the EMR4 pin to the panel for damage
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Engine - EAT/SCR inducement or DEF level lamp / collective error lamp (water in fuel & fuel pressure & air filter clogged) - Voltage below normal or shorted to low source

    • Deutz SPN 524087 FMI 5Engine - EAT/SCR inducement or DEF level lamp / collective error lamp (water in fuel & fuel pressure & air filter clogged): Current low / open circuit

      The EMR4 sees too little current through the EAT/SCR inducement lamp or collective error lamp (in the instrument panel, driven by the EMR4), which means the circuit is open.· Open circuit
      Check soon

      Causes

      • EAT/SCR inducement lamp or collective error lamp winding open
      • Broken wire or a pin pushed out of the connector
      • Connector left unplugged after earlier work

      Checks

      1. 1Trace the lamp wire from the EMR4 pin to the panel for damage
      2. 2Continuity-test each wire to the matching EMR4 pin
      3. 3Measure the resistance across the EAT/SCR inducement lamp or collective error lamp terminals: infinity means an open winding
      4. 4Check that the lamp does a bulb test at key-on
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

      Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

      Source wording:Engine - EAT/SCR inducement or DEF level lamp / collective error lamp (water in fuel & fuel pressure & air filter clogged) - Current below normal or open circuit

    • Deutz SPN 524087 FMI 12Engine - EAT/SCR inducement or DEF level lamp / collective error lamp (water in fuel & fuel pressure & air filter clogged): Bad device or component

      The EMR4 judges the EAT/SCR inducement lamp or collective error lamp (in the instrument panel, driven by the EMR4) to be a bad device, meaning the part or its driver electronics no longer respond as a working component.· Part or controller
      Check soon

      Causes

      • Water or soot inside the part
      • Internal failure of the EAT/SCR inducement lamp or collective error lamp
      • Lamp bulb or LED failed
      • Driver stage in the EMR4 failing

      Checks

      1. 1Measure supply voltage and ground at the EAT/SCR inducement lamp or collective error lamp connector with the key on to confirm the part is powered
      2. 2Fit a known good EAT/SCR inducement lamp or collective error lamp if you can borrow one and see whether the code clears for good
      3. 3Read the EAT/SCR inducement lamp or collective error lamp status in SerDia and run any actuator test
      4. 4Check that the lamp does a bulb test at key-on
      5. 5Trace the lamp wire from the EMR4 pin to the panel for damage
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Engine - EAT/SCR inducement or DEF level lamp / collective error lamp (water in fuel & fuel pressure & air filter clogged) - Bad intelligent device or component

  • Machine - Override switch1 code

    • Deutz SPN 524133 FMI 2Machine - Override switch: Erratic reading

      The EMR4 sees the override switch (on the machine and read by the EMR4) erratic, intermittent or implausible.· Erratic or implausible
      Check soon

      Causes

      • Intermittent contact in a connector or a pin with fretting
      • Harness chafed where it moves with vibration

      Checks

      1. 1Watch the override switch value in SerDia while wiggling the harness and connector and note when it jumps
      2. 2Compare it with a related value, since a lone odd reading points at the circuit or part itself
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Machine - Override switch - Data erratic intermittent or incorrect

  • Machine - GPS status error1 code

    • Deutz SPN 524285 FMI 2Machine - GPS status error: Erratic reading

      The EMR4 sees the GPS status error (on the telematics unit of the machine) erratic, intermittent or implausible.· Erratic or implausible
      Check soon

      Causes

      • Intermittent contact in a connector or a pin with fretting
      • Harness chafed where it moves with vibration

      Checks

      1. 1Watch the GPS status error value in SerDia while wiggling the harness and connector and note when it jumps
      2. 2Compare it with a related value, since a lone odd reading points at the circuit or part itself
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Machine - GPS status error - Data erratic intermittent or incorrect

  • Machine - Telemetry status error1 code

    • Deutz SPN 524286 FMI 2Machine - Telemetry status error: Erratic reading

      The EMR4 sees the telemetry status error (on the telematics unit of the machine) erratic, intermittent or implausible.· Erratic or implausible
      Check soon

      Causes

      • Intermittent contact in a connector or a pin with fretting
      • Harness chafed where it moves with vibration

      Checks

      1. 1Watch the telemetry status error value in SerDia while wiggling the harness and connector and note when it jumps
      2. 2Compare it with a related value, since a lone odd reading points at the circuit or part itself
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Machine - Telemetry status error - Data erratic intermittent or incorrect

Shared checks

Checks, in order

  1. 1Read the pedal signal in SerDia through its whole travel and look for dropouts
  2. 2Check the switch or lamp circuit from the machine wiring diagram, at the engine connector
  3. 3Find out what asked for the shutdown from the freeze frame data
  4. 4Inspect the connectors for moisture and bent pins

Causes

  • Accelerator pedal sensor, its 5 V supply or ground faulty
  • Switch or lamp wiring in the machine harness open or shorted
  • Machine controller requesting a shutdown or limit for its own reasons
  • Telemetry unit without supply or signal

Most common here: erratic or implausible (7 of 22)

Watch the live value on the service tool while you flex the harness and tap the connector.

When to stop

You'll notice: A warning lamp or limited function.

Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.