EF Logo

Deutz · Intake air and boost

Deutz Intake air temperature and pressure sensors fault codes

The sensors that tell the EMR4 what the intake air is doing. Two NTC temperature sensors: the ambient air sensor (SPN 171, 172) in the air intake area or on the machine frame, and the charge air sensor (SPN 105) in the charge air pipe after the cooler.

More about these parts

Three pressure sensors: the charge air (boost) sensor in the intake manifold (SPN 102), the ambient barometric sensor on or in the EMR4 (SPN 108), and the air filter differential pressure sensor (SPN 107) on the filter housing. Each code names the sensor and how its signal failed.

FaultCheckSPN 102FMI 1Deutz · Charge air pressure sensor
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Read the active and stored faults with Deutz SerDia (or the machine maker's diagnostic tool) on the engine diagnostic plug.

What do these codes mean?

Deutz codes SPN 102 FMI 1 to SPN 172 FMI 4 are all about the intake air temperature and pressure sensors. The most common failure type is real condition (10 of 25); none needs an immediate stop. Start with this check: measure an NTC sensor cold and compare its resistance with the air temperature; it should sit in the middle of the curve.

How urgent are they?

None of the 25 codes here means stop now; all 25 can wait until the shift ends, but find the cause before the next one.

  • Check soon25

What should I check first?

Measure an NTC sensor cold and compare its resistance with the air temperature; it should sit in the middle of the curve

Shared checks

25 of 25

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Charge air pressure sensor4 codes

    • Deutz SPN 102 FMI 1Charge air pressure sensor: Reading too low· most severe

      The charge air pressure sensor (in the intake manifold or charge air pipe) reports a value below the allowed range.· Real condition
      Check soon

      Causes

      • A boost leak, a dirty turbo or an air filter blockage can give genuinely low charge pressure under load
      • Charge air pressure sensor drifting low or reading with an offset
      • Oily intake manifold residue entering the sensor port

      Checks

      1. 1Inspect the sensor port, hose and seal for leaks
      2. 2Compare SerDia charge air pressure with ambient pressure on key-on engine-off; they should agree closely
      3. 3Check the real value with a mechanical gauge before replacing the charge air pressure sensor
      4. 4Check the charge air hoses and clamps from the turbo to the manifold for splits or loose clamps
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Engine - Charge air pressure sensor - Data below normal operational range (Most severe level)

      Full page for SPN 102 FMI 1
    • Deutz SPN 102 FMI 2Charge air pressure sensor: Erratic reading

      The EMR4 sees the charge air pressure sensor (in the intake manifold or charge air pipe) signal jump or disagree with other values.· Erratic or implausible
      Check soon

      Causes

      • Charge air pressure sensor on its way out
      • Intermittent contact in the connector
      • Harness chafed against a bracket in a spot that only touches under vibration

      Checks

      1. 1Watch the charge air pressure sensor value in SerDia while wiggling the connector and harness
      2. 2Compare SerDia charge air pressure with ambient pressure on key-on engine-off; they should agree closely
      3. 3Inspect the connector for loose pins, bent terminals and moisture
      4. 4Check the 5 V reference for dips while the fault shows
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Engine - Charge air pressure sensor - Data erratic intermittent or incorrect

    • Deutz SPN 102 FMI 3Charge air pressure sensor: Voltage high / shorted high

      The EMR4 reads the charge air pressure sensor (in the intake manifold or charge air pipe) signal above its valid 0.5 to 4.5 V window.· Shorted high
      Check soon

      Causes

      • Signal wire touching 5 V or battery in the harness
      • Charge air pressure sensor failed high
      • Loose or cracked charge air hose letting boost bleed past the sensor

      Checks

      1. 1Compare the charge air pressure sensor reading in SerDia with key on and engine off against the value you expect at rest
      2. 2Key on: measure the 5 V reference at the charge air pressure sensor plug between supply and ground; 5 V present means the supply side is fine
      3. 3Check continuity of the sensor ground wire back to the EMR4 pin
      4. 4Fit a known good charge air pressure sensor temporarily, if you have one, and see whether the reading moves back into range
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Engine - Charge air pressure sensor - Voltage above normal or shorted to high source

    • Deutz SPN 102 FMI 4Charge air pressure sensor: Voltage low / shorted low

      The EMR4 reads the charge air pressure sensor (in the intake manifold or charge air pipe) signal below its valid 0.5 to 4.5 V window.· Shorted low
      Check soon

      Causes

      • Loose or cracked charge air hose letting boost bleed past the sensor
      • Charge air pressure sensor failed low
      • 5 V reference lost: open supply wire or a short on the shared 5 V line
      • Signal wire rubbed through to ground

      Checks

      1. 1Unplug other sensors sharing the 5 V line one at a time to see whether the reference comes back
      2. 2Key on: measure the 5 V reference at the charge air pressure sensor plug; no reference means open supply wire or another sensor on that line pulling it down
      3. 3Compare the charge air pressure sensor reading in SerDia with key on and engine off against the value you expect at rest
      4. 4Fit a known good charge air pressure sensor temporarily, if you have one, and see whether the reading moves back into range
      5. 5With the sensor unplugged, measure resistance from the signal pin to ground; it should not be near zero
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Engine - Charge air pressure sensor - Voltage below normal or shorted to low source

  • Charge air temperature sensor5 codes

    • Deutz SPN 105 FMI 0Charge air temperature sensor: Reading too high· most severe

      The charge air temperature sensor (in the charge air pipe or intake manifold after the charge air cooler) reports a temperature above the allowed operating range.· Real condition
      Check soon

      Causes

      • Sensor drifting low in resistance with age
      • A fouled charge air cooler, a failed cooling fan or a boost hose leak lets the intake air genuinely run hot
      • Loose charge air hose clamp spraying oil mist onto the connector
      • Partial short or wet connector lowering the charge air temperature sensor resistance so it reads hot

      Checks

      1. 1Inspect the charge air hoses and clamps near the sensor for oil mist or boost leaks that cook the connector
      2. 2Compare SerDia charge air temperature on a cold engine with ambient temperature; they should be very close before starting
      3. 3Check the connector pins for moisture and corrosion, which can pull a reading hot
      4. 4Check the real temperature with an infrared thermometer or mechanical gauge before touching the charge air temperature sensor
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Engine - Charge air temperature sensor - Data above normal operational range (Most severe level)

      Full page for SPN 105 FMI 0
    • Deutz SPN 105 FMI 1Charge air temperature sensor: Reading too low· most severe

      The charge air temperature sensor (in the charge air pipe or intake manifold after the charge air cooler) reports a temperature below the allowed range.· Real condition
      Check soon

      Causes

      • High resistance in the charge air temperature sensor connector or a corroded pin making it read cold
      • Charge air reading far too cold on a hot engine points at a short in the sensor circuit rather than real air temperature
      • Sensor drifting high in resistance after heat cycles

      Checks

      1. 1Measure voltage drop across the connector with the engine running to find a high-resistance joint
      2. 2Inspect the charge air hoses and clamps near the sensor for oil mist or boost leaks that cook the connector
      3. 3Compare the charge air temperature sensor value in SerDia with a neighbouring temperature; if only this one is cold the circuit is suspect
      4. 4Compare SerDia charge air temperature on a cold engine with ambient temperature; they should be very close before starting
      5. 5Measure the real temperature with a second thermometer once the engine has warmed up
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Engine - Charge air temperature sensor - Data below normal operational range (Most severe level)

    • Deutz SPN 105 FMI 3Charge air temperature sensor: Voltage high / shorted high

      The EMR4 reads the charge air temperature sensor (in the charge air pipe or intake manifold after the charge air cooler) at a voltage above its valid window.· Shorted high
      Check soon

      Causes

      • Open circuit: broken wire, pushed-out pin or an unplugged connector at the charge air temperature sensor
      • Heat damage to the plastic sensor body from a charge air leak at the cooler hose
      • Signal wire touching a supply voltage somewhere in the harness
      • Sensor element failed open, so its resistance stays very high at any temperature

      Checks

      1. 1Unplug the charge air temperature sensor and measure its resistance across the two pins; an NTC that reads open at room temperature is finished
      2. 2Bridge the two harness pins with a jumper wire with the key on; the code should change to the voltage-below-normal one if the harness is sound
      3. 3Compare SerDia charge air temperature on a cold engine with ambient temperature; they should be very close before starting
      4. 4With the sensor unplugged and key on, check the signal pin for battery voltage, which would mean a short to supply
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Engine - Charge air temperature sensor - Voltage above normal or shorted to high source

    • Deutz SPN 105 FMI 4Charge air temperature sensor: Voltage low / shorted low

      The EMR4 reads the charge air temperature sensor (in the charge air pipe or intake manifold after the charge air cooler) at a voltage below its valid window.· Shorted low
      Check soon

      Causes

      • Signal wire rubbed through to the engine block or frame
      • Sensor element shorted internally, so it reads as extremely hot
      • Water bridging the pins inside the charge air temperature sensor connector
      • Heat damage to the plastic sensor body from a charge air leak at the cooler hose

      Checks

      1. 1Inspect the charge air hoses and clamps near the sensor for oil mist or boost leaks that cook the connector
      2. 2With the EMR4 unplugged, measure resistance from the signal pin to ground; anything but open points to a short in the wire
      3. 3Unplug the charge air temperature sensor with the key on: if the code flips to the voltage-above-normal one, the harness is fine and the sensor is the shorted part
      4. 4Compare SerDia charge air temperature on a cold engine with ambient temperature; they should be very close before starting
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Engine - Charge air temperature sensor - Voltage below normal or shorted to low source

    • Deutz SPN 105 FMI 11Charge air temperature sensor: Root cause not known

      The EMR4 logged a fault on the charge air temperature sensor (in the charge air pipe or intake manifold after the charge air cooler) but could not pin down the cause.· Other
      Check soon

      Causes

      • Intermittent wiring fault that has not stayed long enough to be classified
      • Failing charge air temperature sensor element
      • Poor ground or supply at the sensor

      Checks

      1. 1Read the full SerDia fault list; this code often appears next to a clearer one on the charge air temperature sensor
      2. 2Measure the charge air temperature sensor resistance and compare with a temperature table
      3. 3Inspect the charge air temperature sensor connector and the harness run for chafed insulation, bent pins and moisture
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Air filter differential pressure sensor2 codes

    • Deutz SPN 107 FMI 0Air filter differential pressure sensor: Reading too high· most severe

      The air filter differential pressure sensor (on the air filter housing or intake pipe) reports a value above the allowed range.· Real condition
      Check soon

      Causes

      • Hose or port feeding the sensor blocked with dirt
      • A really clogged air filter element gives a genuine high restriction reading
      • Air filter differential pressure sensor drifting high or reading with an offset

      Checks

      1. 1Check the real value against a mechanical gauge or second reading before touching the air filter differential pressure sensor
      2. 2Compare with its neighbouring sensors in SerDia to see whether only this value is off
      3. 3Inspect the air filter element and housing seal because a really dirty filter gives a true high reading
      4. 4Check the small sensing hose or port between filter housing and sensor for blockage, split or being pulled off
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Engine - Air filter differential pressure sensor - Data above normal operational range (Most severe level)

    • Deutz SPN 107 FMI 3Air filter differential pressure sensor: Voltage high / shorted high

      The EMR4 reads the air filter differential pressure sensor (on the air filter housing or intake pipe) signal above its valid 0.5 to 4.5 V window.· Shorted high
      Check soon

      Causes

      • Air filter differential pressure sensor failed high
      • Open ground return wire, which pushes the signal up to the reference
      • Signal wire touching 5 V or battery in the harness
      • Sensing hose to the air filter housing split or pulled off

      Checks

      1. 1Fit a known good air filter differential pressure sensor temporarily, if you have one, and see whether the reading moves back into range
      2. 2Key on: measure the 5 V reference at the air filter differential pressure sensor plug between supply and ground; 5 V present means the supply side is fine
      3. 3Check continuity of the sensor ground wire back to the EMR4 pin
      4. 4With the sensor unplugged, measure the signal pin; battery voltage there means a short to supply
      5. 5Compare the air filter differential pressure sensor reading in SerDia with key on and engine off against the value you expect at rest
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Engine - Air filter differential pressure sensor - Voltage above normal or shorted to high source

  • Ambient pressure sensor5 codes

    • Deutz SPN 108 FMI 0Ambient pressure sensor: Reading too high· most severe

      The ambient pressure sensor (on or inside the EMR4 housing, or in the air intake on some installations) reports a value above the allowed range.· Real condition
      Check soon

      Causes

      • Ambient pressure sensor drifting high or reading with an offset
      • Blocked pressure port on the ECU housing
      • Hose or port feeding the sensor blocked with dirt

      Checks

      1. 1Inspect the sensor port or hose for restriction
      2. 2Check the ECU vent port for dirt, paint or a missing seal
      3. 3Compare SerDia ambient pressure at key-on with a local barometric value; it should be close to atmospheric
      4. 4Compare with its neighbouring sensors in SerDia to see whether only this value is off
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Engine - Ambient pressure sensor - Data above normal operational range (Most severe level)

    • Deutz SPN 108 FMI 1Ambient pressure sensor: Reading too low· most severe

      The ambient pressure sensor (on or inside the EMR4 housing, or in the air intake on some installations) reports a value below the allowed range.· Real condition
      Check soon

      Causes

      • Hose or port feeding the sensor split or disconnected
      • Blocked pressure port on the ECU housing
      • Ambient pressure sensor drifting low or reading with an offset

      Checks

      1. 1Check the ECU vent port for dirt, paint or a missing seal
      2. 2Check the real value with a mechanical gauge before replacing the ambient pressure sensor
      3. 3Compare with its neighbouring sensors in SerDia to see whether only this value is off
      4. 4Compare SerDia ambient pressure at key-on with a local barometric value; it should be close to atmospheric
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Engine - Ambient pressure sensor - Data below normal operational range (Most severe level)

    • Deutz SPN 108 FMI 3Ambient pressure sensor: Voltage high / shorted high

      The EMR4 reads the ambient pressure sensor (on or inside the EMR4 housing, or in the air intake on some installations) signal above its valid 0.5 to 4.5 V window.· Shorted high
      Check soon

      Causes

      • Signal wire touching 5 V or battery in the harness
      • Ambient pressure sensor failed high
      • Sensor integrated in the ECU, so internal failure is possible

      Checks

      1. 1Check continuity of the sensor ground wire back to the EMR4 pin
      2. 2With the sensor unplugged, measure the signal pin; battery voltage there means a short to supply
      3. 3Key on: measure the 5 V reference at the ambient pressure sensor plug between supply and ground; 5 V present means the supply side is fine
      4. 4Compare SerDia ambient pressure at key-on with a local barometric value; it should be close to atmospheric
      5. 5Check the ECU vent port for dirt, paint or a missing seal
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Engine - Ambient pressure sensor - Voltage above normal or shorted to high source

    • Deutz SPN 108 FMI 4Ambient pressure sensor: Voltage low / shorted low

      The EMR4 reads the ambient pressure sensor (on or inside the EMR4 housing, or in the air intake on some installations) signal below its valid 0.5 to 4.5 V window.· Shorted low
      Check soon

      Causes

      • Ambient pressure sensor failed low
      • Sensor integrated in the ECU, so internal failure is possible
      • Signal wire rubbed through to ground
      • 5 V reference lost: open supply wire or a short on the shared 5 V line

      Checks

      1. 1Compare SerDia ambient pressure at key-on with a local barometric value; it should be close to atmospheric
      2. 2Key on: measure the 5 V reference at the ambient pressure sensor plug; no reference means open supply wire or another sensor on that line pulling it down
      3. 3Check the ECU vent port for dirt, paint or a missing seal
      4. 4With the sensor unplugged, measure resistance from the signal pin to ground; it should not be near zero
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Engine - Ambient pressure sensor - Voltage below normal or shorted to low source

    • Deutz SPN 108 FMI 11Ambient pressure sensor: Root cause not known

      The EMR4 logged a fault on the ambient pressure sensor (on or inside the EMR4 housing, or in the air intake on some installations) but could not classify the cause.· Other
      Check soon

      Causes

      • Intermittent wiring fault that did not stay long enough to be classified
      • Failing ambient pressure sensor
      • Poor ground or 5 V supply at the sensor

      Checks

      1. 1Read the full SerDia fault list for a clearer code on the ambient pressure sensor
      2. 2Measure 5 V supply and signal voltage at the sensor plug with the key on
      3. 3Inspect the ambient pressure sensor connector and the harness run for chafed insulation, bent pins and moisture
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Ambient air temperature sensor9 codes

    • Deutz SPN 171 FMI 0Ambient air temperature sensor: Reading too high· most severe

      The ambient air temperature sensor (in the engine air intake area or on the machine frame, depending on the installation) reports a temperature above the allowed operating range.· Real condition
      Check soon

      Causes

      • A reading above real ambient can come from a sensor fitted next to the exhaust or radiator, so check where it is installed
      • Harness stub between engine and machine connector damaged by engine bay cleaning
      • Sensor drifting low in resistance with age

      Checks

      1. 1Measure the sensor resistance cold and compare it with ambient temperature; it should sit in the middle of the NTC curve
      2. 2Find out whether the sensor sits on the machine side of the harness and trace it to the engine plug
      3. 3Check the real temperature with an infrared thermometer or mechanical gauge before touching the ambient air temperature sensor
      4. 4Check the connector pins for moisture and corrosion, which can pull a reading hot
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Engine - Ambient air temperature sensor - Data above normal operational range (Most severe level)

    • Deutz SPN 171 FMI 1Ambient air temperature sensor: Reading too low· most severe

      The ambient air temperature sensor (in the engine air intake area or on the machine frame, depending on the installation) reports a temperature below the allowed range.· Real condition
      Check soon

      Causes

      • Harness stub between engine and machine connector damaged by engine bay cleaning
      • High resistance in the ambient air temperature sensor connector or a corroded pin making it read cold
      • A reading far below real ambient in summer means the sensor is shorting or contaminated, not that the air is cold
      • Sensor drifting high in resistance after heat cycles

      Checks

      1. 1Compare the ambient air temperature sensor value in SerDia with a neighbouring temperature; if only this one is cold the circuit is suspect
      2. 2Measure the sensor resistance cold and compare it with ambient temperature; it should sit in the middle of the NTC curve
      3. 3Measure the real temperature with a second thermometer once the engine has warmed up
      4. 4Find out whether the sensor sits on the machine side of the harness and trace it to the engine plug
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Engine - Ambient air temperature sensor - Data below normal operational range (Most severe level)

    • Deutz SPN 171 FMI 3Ambient air temperature sensor: Voltage high / shorted high

      The EMR4 reads the ambient air temperature sensor (in the engine air intake area or on the machine frame, depending on the installation) at a voltage above its valid window.· Shorted high
      Check soon

      Causes

      • Signal wire touching a supply voltage somewhere in the harness
      • Sensor mounted by the machine maker in a spot that collects dirt and washdown water
      • Sensor element failed open, so its resistance stays very high at any temperature

      Checks

      1. 1Bridge the two harness pins with a jumper wire with the key on; the code should change to the voltage-below-normal one if the harness is sound
      2. 2Measure the sensor resistance cold and compare it with ambient temperature; it should sit in the middle of the NTC curve
      3. 3Find out whether the sensor sits on the machine side of the harness and trace it to the engine plug
      4. 4Unplug the ambient air temperature sensor and measure its resistance across the two pins; an NTC that reads open at room temperature is finished
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Engine - Ambient air temperature sensor - Voltage above normal or shorted to high source

    • Deutz SPN 171 FMI 4Ambient air temperature sensor: Voltage low / shorted low

      The EMR4 reads the ambient air temperature sensor (in the engine air intake area or on the machine frame, depending on the installation) at a voltage below its valid window.· Shorted low
      Check soon

      Causes

      • Signal wire rubbed through to the engine block or frame
      • Sensor element shorted internally, so it reads as extremely hot
      • Water bridging the pins inside the ambient air temperature sensor connector

      Checks

      1. 1Measure the sensor resistance cold and compare it with ambient temperature; it should sit in the middle of the NTC curve
      2. 2Measure the ambient air temperature sensor resistance and compare it with its temperature; a very low value means the element is shorted
      3. 3With the EMR4 unplugged, measure resistance from the signal pin to ground; anything but open points to a short in the wire
      4. 4Find out whether the sensor sits on the machine side of the harness and trace it to the engine plug
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Engine - Ambient air temperature sensor - Voltage below normal or shorted to low source

    • Deutz SPN 172 FMI 0Ambient air temperature sensor: Reading too high· most severe

      The ambient air temperature sensor (SPN 172 listing) (in the engine air intake area or on the machine frame) reports a temperature above the allowed operating range.· Real condition
      Check soon

      Causes

      • Sensor fitted next to a hot component reads high, so verify the mounting position
      • Partial short or wet connector lowering the ambient air temperature sensor (SPN 172 listing) resistance so it reads hot
      • Sensor drifting low in resistance with age

      Checks

      1. 1Check the real temperature with an infrared thermometer or mechanical gauge before touching the ambient air temperature sensor (SPN 172 listing)
      2. 2Look in SerDia at the ambient air temperature sensor (SPN 172 listing) reading next to a neighbouring temperature; a lone hot value points at the sensor
      3. 3Check the connector pins for moisture and corrosion, which can pull a reading hot
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Engine - Ambient air temperature sensor - Data above normal operational range (Most severe level)

    • Deutz SPN 172 FMI 1Ambient air temperature sensor: Reading too low· most severe

      The ambient air temperature sensor (SPN 172 listing) (in the engine air intake area or on the machine frame) reports a temperature below the allowed range.· Real condition
      Check soon

      Causes

      • A very low reading in summer points at a shorted sensor
      • High resistance in the ambient air temperature sensor (SPN 172 listing) connector or a corroded pin making it read cold
      • Sensor drifting high in resistance after heat cycles

      Checks

      1. 1Measure the real temperature with a second thermometer once the engine has warmed up
      2. 2Compare the ambient air temperature sensor (SPN 172 listing) value in SerDia with a neighbouring temperature; if only this one is cold the circuit is suspect
      3. 3Measure voltage drop across the connector with the engine running to find a high-resistance joint
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Engine - Ambient air temperature sensor - Data below normal operational range (Most severe level)

    • Deutz SPN 172 FMI 2Ambient air temperature sensor: Erratic reading

      The EMR4 sees the ambient air temperature sensor (SPN 172 listing) (in the engine air intake area or on the machine frame) jump around or disagree with other temperatures.· Erratic or implausible
      Check soon

      Causes

      • Intermittent contact in the connector or a pin with fretting
      • Harness chafed in a spot that makes contact only under vibration
      • Sensor element on its way out in the ambient air temperature sensor (SPN 172 listing)

      Checks

      1. 1Watch the ambient air temperature sensor (SPN 172 listing) value in SerDia while wiggling the harness and connector, and note when it jumps
      2. 2Inspect the connector for loose pins, bent terminals and moisture
      3. 3Check the harness along its route for chafe, especially where it crosses a bracket
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Engine - Ambient air temperature sensor - Data erratic intermittent or incorrect

    • Deutz SPN 172 FMI 3Ambient air temperature sensor: Voltage high / shorted high

      The EMR4 reads the ambient air temperature sensor (SPN 172 listing) (in the engine air intake area or on the machine frame) at a voltage above its valid window.· Shorted high
      Check soon

      Causes

      • Open circuit: broken wire, pushed-out pin or an unplugged connector at the ambient air temperature sensor (SPN 172 listing)
      • Sensor element failed open, so its resistance stays very high at any temperature
      • Signal wire touching a supply voltage somewhere in the harness

      Checks

      1. 1Unplug the ambient air temperature sensor (SPN 172 listing) and measure its resistance across the two pins; an NTC that reads open at room temperature is finished
      2. 2Bridge the two harness pins with a jumper wire with the key on; the code should change to the voltage-below-normal one if the harness is sound
      3. 3With the sensor unplugged and key on, check the signal pin for battery voltage, which would mean a short to supply
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Engine - Ambient air temperature sensor - Voltage above normal or shorted to high source

    • Deutz SPN 172 FMI 4Ambient air temperature sensor: Voltage low / shorted low

      The EMR4 reads the ambient air temperature sensor (SPN 172 listing) (in the engine air intake area or on the machine frame) at a voltage below its valid window.· Shorted low
      Check soon

      Causes

      • Signal wire rubbed through to the engine block or frame
      • Sensor element shorted internally, so it reads as extremely hot
      • Water bridging the pins inside the ambient air temperature sensor (SPN 172 listing) connector

      Checks

      1. 1Unplug the ambient air temperature sensor (SPN 172 listing) with the key on: if the code flips to the voltage-above-normal one, the harness is fine and the sensor is the shorted part
      2. 2With the EMR4 unplugged, measure resistance from the signal pin to ground; anything but open points to a short in the wire
      3. 3Measure the ambient air temperature sensor (SPN 172 listing) resistance and compare it with its temperature; a very low value means the element is shorted
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Engine - Ambient air temperature sensor - Voltage below normal or shorted to low source

Shared checks

Checks, in order

  1. 1Measure an NTC sensor cold and compare its resistance with the air temperature; it should sit in the middle of the curve
  2. 2With key on and engine off, compare SerDia charge air pressure and ambient pressure; they should agree closely
  3. 3Check the charge air hoses and clamps from the turbo to the manifold for splits, leaks and oil mist
  4. 4Check the small sensing hose between the air filter housing and its sensor for blockage or a pulled-off end
  5. 5Inspect each sensor connector for moisture, bent pins and chafing before replacing a part

Causes

  • Sensor body or connector damaged by heat or oil mist from a loose charge air hose clamp
  • Sensor mounted where washdown water and dirt collect, or a harness stub damaged by engine bay cleaning
  • Blocked or split sensing hose or port on a pressure sensor
  • Fault in the sensor, its 5 V supply or its ground wire

Most common here: real condition (10 of 25)

Check the real value with a separate gauge or thermometer before blaming the sensor.

When to stop

You'll notice: A warning lamp or limited function.

Let the engine cool before opening the cooling system; a hot cap releases scalding coolant. Running on with an overheat warning risks a head gasket or seized engine.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.