Deutz · Intake air and boost
Deutz Turbocharger, wastegate and disc separator fault codes
The boost side of the engine. The turbocharger pressure sensors (charge and turbine pressure), the turbine inlet temperature sensor, the electric wastegate actuator that sets the boost level, and the disc separator that cleans the crankcase gas.
More about these partsLess
Each code names the part and whether its signal, its drive or its movement failed.
Where to read it
Read the active and stored faults with Deutz SerDia (or the machine maker's diagnostic tool) on the engine diagnostic plug.
What do these codes mean?
Deutz codes SPN 1176 FMI 0 to SPN 524149 FMI 2 are all about the turbocharger, wastegate and disc separator. The most common failure type is real condition (5 of 22); none needs an immediate stop. Start with this check: move the wastegate by hand with the key off and look for soot sticking or free play.
How urgent are they?
None of the 22 codes here means stop now; all 22 can wait until the shift ends, but find the cause before the next one.
- Check soon22
What should I check first?
Move the wastegate by hand with the key off and look for soot sticking or free play
Shared checks22 of 22
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
TC charge pressure5 codes
Deutz SPN 1176 FMI 0TC charge pressure: Reading too high· most severe
The turbocharger charge pressure signal (in the charge air path between the turbocharger and intake manifold) reports a value above the allowed range. This is a plausibility limit, so the high value may be genuine rather than a wiring fault. Deutz list: KWP code 847, blink code 139.· Real conditionReal conditionCheck soonCauses
- Hose or port feeding the sensor blocked with dirt
- Turbocharger charge pressure signal drifting high or reading with an offset
- Boost above target means the wastegate is not opening or the actuator has failed, so check that circuit next
- Wastegate actuator not matching the commanded boost
Checks
- 1Check the real value against a mechanical gauge or second reading before touching the turbocharger charge pressure signal
- 2Inspect the sensor port or hose for restriction
- 3Compare with its neighbouring sensors in SerDia to see whether only this value is off
- 4Compare SerDia charge pressure against load: a healthy engine builds boost steadily under load
- 5Smoke-test or pressure-test the charge air path for leaks while the sensor reads low
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:Engine - TC charge pressure - Data above normal operational range (Most severe level)
Deutz SPN 1176 FMI 1TC charge pressure: Reading too low· most severe
The turbocharger charge pressure signal (in the charge air path between the turbocharger and intake manifold) reports a value below the allowed range. This is a plausibility limit, so the low value may be genuine rather than a wiring fault. Deutz list: KWP code 848, blink code 139.· Real conditionReal conditionCheck soonCauses
- Wastegate actuator not matching the commanded boost
- Boost below target often means a leak, a worn turbo or the wastegate stuck open
- Hose or port feeding the sensor split or disconnected
Checks
- 1Inspect the sensor port, hose and seal for leaks
- 2Smoke-test or pressure-test the charge air path for leaks while the sensor reads low
- 3Compare SerDia charge pressure against load: a healthy engine builds boost steadily under load
- 4Check the real value with a mechanical gauge before replacing the turbocharger charge pressure signal
- 5Compare with its neighbouring sensors in SerDia to see whether only this value is off
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:Engine - TC charge pressure - Data below normal operational range (Most severe level)
Deutz SPN 1176 FMI 2TC charge pressure: Erratic reading
The EMR4 sees the turbocharger charge pressure signal (in the charge air path between the turbocharger and intake manifold) signal jump or disagree with other values. The signal is present but unstable, which usually means a loose joint or a failing sensor. Deutz list: KWP code 1549, blink code 139.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Intermittent contact in the connector
- Turbocharger charge pressure signal on its way out
- Harness chafed against a bracket in a spot that only touches under vibration
Checks
- 1Check the 5 V reference for dips while the fault shows
- 2Inspect the connector for loose pins, bent terminals and moisture
- 3Compare SerDia charge pressure against load: a healthy engine builds boost steadily under load
- 4Smoke-test or pressure-test the charge air path for leaks while the sensor reads low
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:Engine - TC charge pressure - Data erratic intermittent or incorrect
Deutz SPN 1176 FMI 3TC charge pressure: Voltage high / shorted high
The EMR4 reads the turbocharger charge pressure signal (in the charge air path between the turbocharger and intake manifold) signal above its valid 0.5 to 4.5 V window. That points to an open sensor ground, a short to supply on the signal wire, or a failed sensor. Deutz list: KWP code 849, blink code 141.· Shorted highShorted highCheck soonCauses
- Boost leak between turbo and manifold
- Signal wire touching 5 V or battery in the harness
- Open ground return wire, which pushes the signal up to the reference
Checks
- 1Key on: measure the 5 V reference at the turbocharger charge pressure signal plug between supply and ground; 5 V present means the supply side is fine
- 2Check continuity of the sensor ground wire back to the EMR4 pin
- 3Fit a known good turbocharger charge pressure signal temporarily, if you have one, and see whether the reading moves back into range
- 4Compare the turbocharger charge pressure signal reading in SerDia with key on and engine off against the value you expect at rest
- 5With the sensor unplugged, measure the signal pin; battery voltage there means a short to supply
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Engine - TC charge pressure - Voltage above normal or shorted to high source
Deutz SPN 1176 FMI 4TC charge pressure: Voltage low / shorted low
The EMR4 reads the turbocharger charge pressure signal (in the charge air path between the turbocharger and intake manifold) signal below its valid 0.5 to 4.5 V window. That points to a shorted signal wire, a lost 5 V reference, or a failed sensor. Deutz list: KWP code 850, blink code 141.· Shorted lowShorted lowCheck soonCauses
- Signal wire rubbed through to ground
- 5 V reference lost: open supply wire or a short on the shared 5 V line
- Turbocharger charge pressure signal failed low
Checks
- 1Key on: measure the 5 V reference at the turbocharger charge pressure signal plug; no reference means open supply wire or another sensor on that line pulling it down
- 2With the sensor unplugged, measure resistance from the signal pin to ground; it should not be near zero
- 3Unplug other sensors sharing the 5 V line one at a time to see whether the reference comes back
- 4Compare the turbocharger charge pressure signal reading in SerDia with key on and engine off against the value you expect at rest
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Engine - TC charge pressure - Voltage below normal or shorted to low source
TC charge temperature upstream turbine3 codes
Deutz SPN 1180 FMI 0TC charge temperature upstream turbine: Reading too high· most severe
The turbocharger turbine inlet temperature (in the exhaust manifold or at the turbine inlet) reports a temperature above the allowed operating range. This is a plausibility limit rather than a wiring fault, so the high reading may well be real. Deutz list: KWP code 1193, blink code 5-5-6.· Real conditionReal conditionCheck soonCauses
- Real over-temperature comes from restricted exhaust, a blocked DPF, over-fuelling or a failing turbo, so find that cause first
- Sensor probe sooted or burned
- Partial short or wet connector lowering the turbocharger turbine inlet temperature resistance so it reads hot
Checks
- 1Check the real temperature with an infrared thermometer or mechanical gauge before touching the turbocharger turbine inlet temperature
- 2Compare SerDia turbine inlet temperature with load; it should rise steadily as load increases
- 3Check the heat shield and clip positions on the harness near the manifold
- 4Look in SerDia at the turbocharger turbine inlet temperature reading next to a neighbouring temperature; a lone hot value points at the sensor
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:Engine - TC charge temperature upstream turbine - Data above normal operational range (Most severe level)
Deutz SPN 1180 FMI 1TC charge temperature upstream turbine: Reading too low· most severe
The turbocharger turbine inlet temperature (in the exhaust manifold or at the turbine inlet) reports a temperature below the allowed range. This can be a genuine cold condition or a sensor circuit with extra resistance, so verify with a second thermometer. Deutz list: KWP code 1194, blink code 5-5-6.· Real conditionReal conditionCheck soonCauses
- A reading lower than plausible under load suggests a failed sensor or shorted wiring
- High resistance in the turbocharger turbine inlet temperature connector or a corroded pin making it read cold
- Sensor drifting high in resistance after heat cycles
Checks
- 1Compare the turbocharger turbine inlet temperature value in SerDia with a neighbouring temperature; if only this one is cold the circuit is suspect
- 2Measure voltage drop across the connector with the engine running to find a high-resistance joint
- 3Measure the real temperature with a second thermometer once the engine has warmed up
- 4Check the heat shield and clip positions on the harness near the manifold
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:Engine - TC charge temperature upstream turbine - Data below normal operational range (Most severe level)
Deutz SPN 1180 FMI 3TC charge temperature upstream turbine: Voltage high / shorted high
The EMR4 reads the turbocharger turbine inlet temperature (in the exhaust manifold or at the turbine inlet) at a voltage above its valid window. On a two-wire NTC sensor that means the circuit looks open or pulled up to a supply, so the controller has no usable temperature. Deutz list: KWP code 1067, blink code 556.· Shorted highShorted highCheck soonCauses
- Open circuit: broken wire, pushed-out pin or an unplugged connector at the turbocharger turbine inlet temperature
- Sensor element failed open, so its resistance stays very high at any temperature
- Signal wire touching a supply voltage somewhere in the harness
Checks
- 1Unplug the turbocharger turbine inlet temperature and measure its resistance across the two pins; an NTC that reads open at room temperature is finished
- 2Bridge the two harness pins with a jumper wire with the key on; the code should change to the voltage-below-normal one if the harness is sound
- 3With the sensor unplugged and key on, check the signal pin for battery voltage, which would mean a short to supply
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Engine - TC charge temperature upstream turbine - Voltage above normal or shorted to high source
TC wastegate9 codes
Deutz SPN 1188 FMI 0TC wastegate: Reading too high· most severe
The EMR4 sees the turbocharger wastegate actuator (on the turbocharger, where the electric actuator moves the wastegate) above its allowed range. The controller treats this as a serious level. Deutz list: KWP code 1799, blink code 814.· Real conditionReal conditionCheck soonCauses
- Part driven beyond its limit
- Wastegate linkage seized by carbon or rust
- Wastegate linkage seized with soot
Checks
- 1Check the turbocharger wastegate actuator moves freely through its range by hand with the key off
- 2Check the actuator rod and linkage move freely, with the key off
- 3Read the actual value against the target in SerDia
- 4Inspect the supply and control wiring of the turbocharger wastegate actuator for chafe, water and corrosion
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:Engine - TC wastegate - Data above normal operational range (Most severe level)
Deutz SPN 1188 FMI 2TC wastegate: Erratic reading
The EMR4 sees the turbocharger wastegate actuator (on the turbocharger, where the electric actuator moves the wastegate) behave erratically against the command, which can mean a sticking part or an intermittent connection. Deutz list: KWP code 1414, blink code 814.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Wastegate linkage seized by carbon or rust
- Actuator rod disconnected or bent
- Intermittent contact in the connector
- Wastegate linkage seized with soot
Checks
- 1Command the turbocharger wastegate actuator from SerDia and watch actual versus commanded behaviour for lag or dropouts
- 2Check the actuator rod and linkage move freely, with the key off
- 3Check both connector halves of the turbocharger wastegate actuator for loose, bent or fretted pins
- 4Wiggle the turbocharger wastegate actuator harness and connector while watching the live status in SerDia for dropouts
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:Engine - TC wastegate - Data erratic intermittent or incorrect
Deutz SPN 1188 FMI 3TC wastegate: Voltage high / shorted high
The EMR4 sees the output for the turbocharger wastegate actuator (on the turbocharger, where the electric actuator moves the wastegate) at a voltage above normal, as if the circuit is shorted to the battery supply. The controller cannot drive the actuator correctly. Deutz list: KWP code 1794, blink code 814.· Shorted highShorted highCheck soonCauses
- Turbocharger wastegate actuator shorted internally
- Actuator rod disconnected or bent
- Connector pin touching a live pin
- Output wire shorted to battery positive
Checks
- 1Measure the winding or coil resistance of the part
- 2With the EMR4 unplugged, measure the output wire to battery positive; it should be open
- 3Compare commanded and actual wastegate position in SerDia and see whether the actuator moves at all
- 4Unplug the turbocharger wastegate actuator: if the code stays, the short is in the harness or the EMR4; if it clears, the part is the shorted one
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Engine - TC wastegate - Voltage above normal or shorted to high source
Deutz SPN 1188 FMI 4TC wastegate: Voltage low / shorted low
The EMR4 sees the output for the turbocharger wastegate actuator (on the turbocharger, where the electric actuator moves the wastegate) at a voltage below normal, as if the circuit is shorted to ground. The controller cannot drive the actuator correctly. Deutz list: KWP code 1795, blink code 814.· Shorted lowShorted lowCheck soonCauses
- Actuator rod disconnected or bent
- Turbocharger wastegate actuator winding shorted to its housing
- Water in the connector bridging the pins
Checks
- 1Measure the winding resistance of the part and look for a very low value
- 2Unplug the turbocharger wastegate actuator: if the code changes, the part is the shorted one; if it stays, look at the harness
- 3Compare commanded and actual wastegate position in SerDia and see whether the actuator moves at all
- 4Check the actuator rod and linkage move freely, with the key off
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Engine - TC wastegate - Voltage below normal or shorted to low source
Deutz SPN 1188 FMI 6TC wastegate: Current high / grounded
The EMR4 sees too much current through the turbocharger wastegate actuator (on the turbocharger, where the electric actuator moves the wastegate). A shorted winding or wiring fault is drawing more current than the controller allows. Deutz list: KWP code 1793, blink code 814.· Shorted lowShorted lowCheck soonCauses
- Wastegate linkage seized by carbon or rust
- Wire chafed to ground
- Actuator rod disconnected or bent
Checks
- 1Measure the turbocharger wastegate actuator winding resistance; a low value means it is shorting
- 2Compare commanded and actual wastegate position in SerDia and see whether the actuator moves at all
- 3Move the part by hand with the key off to see whether it is seized
- 4Check the actuator rod and linkage move freely, with the key off
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Engine - TC wastegate - Current above normal or grounded circuit
Deutz SPN 1188 FMI 7TC wastegate: Not responding / out of adjustment
The EMR4 sees the turbocharger wastegate actuator (on the turbocharger, where the electric actuator moves the wastegate) not following its commanded position or movement. The signal is fine; the part itself is not moving as it should. Deutz list: KWP code 1415, blink code 814.· Part or controllerPart or controllerCheck soonCauses
- Wastegate linkage seized by carbon or rust
- Wastegate linkage seized with soot
- Actuator rod disconnected or bent
Checks
- 1Command it from SerDia and watch actual position against commanded
- 2Move the part by hand with the key off to see whether it is stuck
- 3Inspect for soot, oil or foreign matter around the part
- 4Check the actuator rod and linkage move freely, with the key off
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Source wording:Engine - TC wastegate - Mechanical system not responding or out of adjustment
Deutz SPN 1188 FMI 11TC wastegate: Root cause not known
The EMR4 logged a fault on the turbocharger wastegate actuator (on the turbocharger, where the electric actuator moves the wastegate) but could not classify the cause. Test the circuit and the part separately. Deutz list: KWP codes 1411, 1412, 1417 and 1418, blink code 814.· OtherOtherCheck soonCauses
- Intermittent wiring fault
- Failing turbocharger wastegate actuator
Checks
- 1Read the full SerDia fault list; this code often sits next to a clearer one on the turbocharger wastegate actuator
- 2Measure the supply and ground at the turbocharger wastegate actuator plug with the key on to confirm it is powered
- 3Inspect the turbocharger wastegate actuator plug and harness for chafed insulation, bent pins and moisture
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Deutz SPN 1188 FMI 12TC wastegate: Bad device or component
The EMR4 judges the turbocharger wastegate actuator (on the turbocharger, where the electric actuator moves the wastegate) to be a bad device, meaning the part or its driver electronics no longer respond as a working component. Deutz list: KWP code 1791, blink code 814.· Part or controllerPart or controllerCheck soonCauses
- Driver stage in the EMR4 failing
- Actuator rod disconnected or bent
- Water or soot inside the part
Checks
- 1Read the turbocharger wastegate actuator status in SerDia and run any actuator test
- 2Compare commanded and actual wastegate position in SerDia and see whether the actuator moves at all
- 3Check the actuator rod and linkage move freely, with the key off
- 4Measure supply voltage and ground at the turbocharger wastegate actuator connector with the key on to confirm the part is powered
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Source wording:Engine - TC wastegate - Bad intelligent device or component
Deutz SPN 1188 FMI 13TC wastegate: Out of calibration
The EMR4 reports the turbocharger wastegate actuator (on the turbocharger, where the electric actuator moves the wastegate) as out of calibration. The learned end positions or characteristics no longer match what the controller expects. Deutz list: KWP codes 1413, 1790, 1792 and 1796, blink code 814.· Part or controllerPart or controllerCheck soonCauses
- Turbocharger wastegate actuator replaced without a recalibration
- Mechanical wear or play shifting the end positions
Checks
- 1Run the end-position learn or calibration routine in SerDia, if your service tool offers it for the turbocharger wastegate actuator
- 2Check the turbocharger wastegate actuator for mechanical play or a loose linkage that shifts its end positions
- 3Replace the turbocharger wastegate actuator if the end-position learn routine in SerDia fails repeatedly
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Disc separator4 codes
Deutz SPN 524034 FMI 3Disc separator: Voltage high / shorted high
The EMR4 sees the output for the disc separator (in the crankcase ventilation of the engine) at a voltage above normal, as if the circuit is shorted to the battery supply. The controller cannot drive the actuator correctly. Deutz list: KWP code 1438, blink code 816.· Shorted highShorted highCheck soonCauses
- Output wire shorted to battery positive
- Connector pin touching a live pin
- Disc separator shorted internally
Checks
- 1Unplug the disc separator: if the code stays, the short is in the harness or the EMR4; if it clears, the part is the shorted one
- 2With the EMR4 unplugged, measure the output wire to battery positive; it should be open
- 3Measure the winding or coil resistance of the part
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Engine - Disc separator - Voltage above normal or shorted to high source
Deutz SPN 524034 FMI 4Disc separator: Voltage low / shorted low
The EMR4 sees the output for the disc separator (in the crankcase ventilation of the engine) at a voltage below normal, as if the circuit is shorted to ground. The controller cannot drive the actuator correctly. Deutz list: KWP code 1439, blink code 816.· Shorted lowShorted lowCheck soonCauses
- Output wire chafed to ground or the engine block
- Disc separator winding shorted to its housing
- Water in the connector bridging the pins
Checks
- 1Unplug the disc separator: if the code changes, the part is the shorted one; if it stays, look at the harness
- 2With the EMR4 unplugged, measure the output wire to ground; it should not be low ohms
- 3Measure the winding resistance of the part and look for a very low value
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Engine - Disc separator - Voltage below normal or shorted to low source
Deutz SPN 524034 FMI 5Disc separator: Current low / open circuit
The EMR4 sees too little current through the disc separator (in the crankcase ventilation of the engine), which means the circuit is open. The controller commands the actuator but nothing flows. Deutz list: KWP code 1436, blink code 816.· Open circuitOpen circuitCheck soonCauses
- Broken wire or a pin pushed out of the connector
- Disc separator winding open
- Connector left unplugged after earlier work
Checks
- 1Measure the resistance across the disc separator terminals: infinity means an open winding
- 2Continuity-test each wire to the matching EMR4 pin
- 3Inspect both ends of the disc separator circuit (EMR4 plug and part connector) for pins pushed back in the housing
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Source wording:Engine - Disc separator - Current below normal or open circuit
Deutz SPN 524034 FMI 12Disc separator: Bad device or component
The EMR4 judges the disc separator (in the crankcase ventilation of the engine) to be a bad device, meaning the part or its driver electronics no longer respond as a working component. Deutz list: KWP code 1437, blink code 816.· Part or controllerPart or controllerCheck soonCauses
- Internal failure of the disc separator
- Water or soot inside the part
- Driver stage in the EMR4 failing
Checks
- 1Read the disc separator status in SerDia and run any actuator test
- 2Measure supply voltage and ground at the disc separator connector with the key on to confirm the part is powered
- 3Fit a known good disc separator if you can borrow one and see whether the code clears for good
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Source wording:Engine - Disc separator - Bad intelligent device or component
TC pressure after turbine1 code
Deutz SPN 524149 FMI 2TC pressure after turbine: Erratic reading
The EMR4 sees the TC pressure after turbine (in the charge air path between the turbocharger and intake manifold) signal jump or disagree with other values. The signal is present but unstable, which usually means a loose joint or a failing sensor. Deutz list: KWP codes 1545 and 1597, blink code 968.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Intermittent contact in the connector
- Harness chafed against a bracket in a spot that only touches under vibration
- TC pressure after turbine on its way out
Checks
- 1Watch the TC pressure after turbine value in SerDia while wiggling the connector and harness
- 2Inspect the connector for loose pins, bent terminals and moisture
- 3Check the 5 V reference for dips while the fault shows
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:Engine - TC pressure after turbine - Data erratic intermittent or incorrect
Shared checks
Checks, in order
- 1Move the wastegate by hand with the key off and look for soot sticking or free play
- 2Read turbine inlet temperature in SerDia on a cold engine and compare it with ambient
- 3Check the intake and exhaust piping for leaks between turbo and manifold
- 4Measure supply and ground at the actuator or separator connector with the key on
- 5Inspect the connectors near the exhaust for heat damage and spread pins
Causes
- Wastegate actuator stuck by soot, or its linkage or motor failed
- Turbine inlet sensor in the hot exhaust with burnt wiring or a corroded plug
- Boost leak or damaged hose upsetting the pressure readings
- Disc separator drive or sensor with a fault in its circuit
Most common here: real condition (5 of 22)
Check the real value with a separate gauge or thermometer before blaming the sensor.
When to stop
You'll notice: A warning lamp or limited function.
Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.