EF Logo

Bobcat · Fuel system

Bobcat Fuel hold, fuel pull and lift pump circuits fault codes

On mechanically governed engines the fuel stop solenoid has a pull coil that draws the plunger in to run and a hold coil that keeps it there. A relay and the electric lift pump feed the same system.

More about these parts

A code names the coil, relay or pump circuit that is open, shorted or stuck.

FaultStop14-03Bobcat · Fuel hold, fuel pull and lift pump circuits
Code shows hereFAULT14-03

Where this code shows

On touchscreen R-series machines, touch the screen and pick Service Codes from the menu.

What do these codes mean?

Bobcat codes 13-05 to M9287 are all about the fuel hold, fuel pull and lift pump circuits. The most common failure type is shorted high (5 of 22); 13 need an immediate stop. Start with this check: key on and listen for the solenoid click and the lift pump running; no click with good voltage at the plug points to the coil.

How urgent are they?

13 of 22 codes here mean stop now; the other 9 can wait until the shift ends, but find the cause before the next one.

  • Stop now13
  • Check soon9

What should I check first?

Key on and listen for the solenoid click and the lift pump running; no click with good voltage at the plug points to the coil.

Shared checks

22 of 22

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Bobcat 13-05Fuel shut-off hold solenoid short to battery

    The controller found the fuel hold solenoid circuit tied to battery voltage when it should be able to switch it.· Shorted high
    Stop now

    Causes

    • Heat damage to the shut-off plug from the engine side
    • Water or corrosion in the fuel hold solenoid plug bridging output to supply
    • Fuel hold solenoid wire rubbed against a live feed along the engine harness where it is clipped close to the fuel shut-off and the hot exhaust side

    Checks

    1. 1Inspect the engine harness where it is clipped close to the fuel shut-off and the hot exhaust side for rubbed insulation where a supply wire could touch the fuel hold solenoid output wire
    2. 2Unplug the fuel hold solenoid and, with the key on, measure the controller-side output pin to ground; it should not show battery voltage while the output is off
    3. 3With the key off, measure across the fuel hold solenoid coil pins; a shorted coil reads close to zero and a good one shows a steady resistance
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat 13-06Fuel shut-off hold solenoid short to ground

    The controller found the fuel hold solenoid circuit pulled to ground when it should be able to switch it.· Shorted low
    Stop now

    Causes

    • Fuel hold solenoid output wire rubbed through to ground along the engine harness where it is clipped close to the fuel shut-off and the hot exhaust side
    • Harness pinched against a frame bracket
    • Coil shorted to its housing

    Checks

    1. 1Check the engine harness where it is clipped close to the fuel shut-off and the hot exhaust side for a pinched or chafed spot against the frame or a bracket
    2. 2Look for water and corrosion in the fuel hold solenoid plug, and read the fuel pull codes, which belong to the same shut-off
    3. 3Unplug the fuel hold solenoid and measure the controller-side output wire to ground with the key off; a low reading means a short to ground
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat 13-07Fuel shut-off solenoid open circuit

    The controller sees no load on the fuel hold solenoid circuit, which means the circuit is open.· Open circuit
    Stop now

    Causes

    • Broken wire between the controller and the fuel hold solenoid
    • Coil winding open
    • Heat damage to the shut-off plug from the engine side

    Checks

    1. 1Pull the plug and check for a pin that has backed out or a terminal that no longer grips the blade
    2. 2Check that the fuel hold solenoid plug is fully seated and latched at the fuel shut-off on the engine
    3. 3Check continuity of both wires between the fuel hold solenoid plug and the controller with the key off, flexing the engine harness where it is clipped close to the fuel shut-off and the hot exhaust side as you test
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat 14-02Fuel shut-off pull solenoid error ON

    The controller sees the fuel pull solenoid energised when it has commanded it off.· Other
    Stop now

    Causes

    • Controller output stuck on
    • Wiring cross-connected to another output
    • Vibration fatigue in the wires at the shut-off plug

    Checks

    1. 1Check the engine harness around the shut-off plug where heat and vibration crack the insulation for rubbed insulation touching a live wire
    2. 2Check for a shut-off plunger that binds so the coil cannot pull it in, which can hold the function on even with the coil off
    3. 3With the fuel pull solenoid unplugged and the output commanded off, check for voltage on the output pin; any voltage shows a stuck driver or a short to a live wire
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat 14-03Fuel shut-off pull solenoid error OFF

    The fuel pull solenoid is not energised when it should be on, so the engine may not start.· Other
    Stop now

    Causes

    • Output driver not switching
    • Broken wire or loose plug
    • Blown fuse on the fuel pull solenoid feed
    • Open coil
    • Vibration fatigue in the wires at the shut-off plug

    Checks

    1. 1Check the wiring along the engine harness around the shut-off plug where heat and vibration crack the insulation for continuity and for pins pushed back out of their housings
    2. 2Check for a shut-off plunger that binds so the coil cannot pull it in, which can make the coil draw wrongly
    3. 3Check the fuse that supplies the fuel pull solenoid circuit and replace it if blown, then look for the cause
    4. 4Measure the fuel pull solenoid coil resistance with the plug off; an open coil reads infinite
    5. 5Check that the shut-off linkage is not bent or binding, since a stiff plunger makes the pull coil work harder than it should
    6. 6With the key on and the function commanded, measure the voltage on the output wire at the plug. Then: turn the key to start and listen for the pull solenoid to click before the starter takes over; the engine should then fire normally
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat P1134-12Fuel lift pump short to battery

    The controller reads the fuel lift pump circuit as tied to battery voltage when it should be switched by the controller.· Shorted high
    Check soon

    Causes

    • Output wire rubbed through and touching a live supply wire
    • Water or corrosion in the plug bridging a pin to a power pin
    • Controller output stage failed shorted to supply

    Checks

    1. 1Unplug the fuel lift pump and check the output wire for voltage with the key on; any voltage with the load removed is a short to supply
    2. 2Trace the wire along the harness for chafing next to live supply wires and for melted insulation
    3. 3Replace the fuel lift pump only if the wire reads clean and the coil or element itself reads shorted
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat P1134-13Fuel lift pump open circuit

    The controller sees an open circuit on the fuel lift pump, meaning no current can flow through it.· Open circuit
    Check soon

    Causes

    • Pin backed out of the connector or plug not latched
    • Wire broken inside its insulation near a bend or clamp
    • Coil or element burnt open

    Checks

    1. 1Check the connector at the fuel lift pump is fully seated and its lock tab engaged
    2. 2Measure the resistance across the part with the plug off; infinite resistance confirms an open
    3. 3Check continuity of each wire from the plug back to the controller connector
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat M1305Fuel hold solenoid short to battery

    The fuel hold solenoid output is shorted to battery voltage, so the controller cannot switch the circuit properly.· Shorted high
    Stop now

    Causes

    • Moisture bridging the plug pins
    • Heat damage to the shut-off plug from the engine side
    • Fuel hold solenoid winding shorted internally, often from a fuel shut-off plunger that sticks from dirt or varnish

    Checks

    1. 1Follow the engine harness where it is clipped close to the fuel shut-off and the hot exhaust side looking for melted or rubbed insulation next to supply wires
    2. 2Dry and clean the plug and re-seat it, and read the fuel pull codes, which belong to the same shut-off to see whether other outputs are affected
    3. 3With the fuel hold solenoid unplugged and the key on, check its output wire for voltage; any voltage while the output is off shows a short to supply
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat M1306Fuel hold solenoid short to ground

    The fuel hold solenoid output is shorted to ground, so the coil will not energise correctly.· Shorted low
    Stop now

    Causes

    • Heat damage to the shut-off plug from the engine side
    • Chafed output wire touching the frame where the engine harness reaches the fuel shut-off
    • Harness crushed at a bracket or clamp

    Checks

    1. 1With the plug off, test the fuel hold solenoid output wire to chassis ground; a reading near zero shows a harness short to ground
    2. 2Trace the wire through the engine harness where it is clipped close to the fuel shut-off and the hot exhaust side, looking for rubs and sections crushed under clamps
    3. 3Check that the harness clips are in place and not cutting into the wire; compare with the fuel pull codes, which belong to the same shut-off
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat M1307Fuel hold solenoid open circuit

    The fuel hold solenoid output circuit is open.· Open circuit
    Stop now

    Causes

    • Heat damage to the shut-off plug from the engine side
    • Fuse or feed missing on the supply side
    • Loose or corroded terminal in the plug

    Checks

    1. 1Look at the terminals inside the plug for corrosion, spread contacts or a loose crimp; read the fuel pull codes, which belong to the same shut-off for related faults
    2. 2Check the fuse for the fuel hold solenoid circuit and confirm it is the right rating
    3. 3Check the supply and return wires of the fuel hold solenoid for continuity, flexing the engine harness where it is clipped close to the fuel shut-off and the hot exhaust side as you test
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat M1402Fuel pull output error on

    The controller sees the fuel pull solenoid energised when it is commanded off.· Other
    Stop now

    Causes

    • Latched output stage in the controller
    • Short to supply on the fuel pull solenoid output wire
    • Another circuit in the same plug shorting in

    Checks

    1. 1Trace the harness through the engine harness around the shut-off plug where heat and vibration crack the insulation looking for chafing against a power wire
    2. 2Inspect for a shut-off plunger that binds so the coil cannot pull it in
    3. 3Unplug the fuel pull solenoid and measure the output wire voltage with the output off; it should read zero
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M1403Fuel pull output error off

    The controller sees the fuel pull solenoid not energised when it is commanded on.· Other
    Stop now

    Causes

    • Fuse or relay feeding the fuel pull solenoid circuit open
    • Failed coil
    • Loose or broken connection
    • Vibration fatigue in the wires at the shut-off plug
    • Controller output not switching

    Checks

    1. 1Inspect the engine harness around the shut-off plug where heat and vibration crack the insulation for breaks, rubbing and corrosion
    2. 2Check the fuse and relay for the fuel pull solenoid circuit and test the supply with the key on
    3. 3Measure the voltage at the fuel pull solenoid plug while the function is commanded; no voltage means a harness or controller fault
    4. 4Check the coil resistance and compare it with the same coil on another unit; read the fuel hold codes that act on the same shut-off
    5. 5Check that the shut-off linkage is not bent or binding, since a stiff plunger makes the pull coil work harder than it should
    6. 6Look for a shut-off plunger that binds so the coil cannot pull it in and clear it before replacing parts, then verify: turn the key to start and listen for the pull solenoid to click before the starter takes over; the engine should then fire normally
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M1407Fuel pull output open circuit

    The fuel pull solenoid output circuit is open.· Open circuit
    Stop now

    Causes

    • Fuse or feed missing on the supply side
    • Wire broken inside the insulation at the fuel shut-off end of the engine harness
    • Open coil

    Checks

    1. 1Look at the terminals inside the plug for corrosion, spread contacts or a loose crimp; read the fuel hold codes that act on the same shut-off for related faults
    2. 2Check the fuse for the fuel pull solenoid circuit and confirm it is the right rating
    3. 3Check the supply and return wires of the fuel pull solenoid for continuity, flexing the engine harness around the shut-off plug where heat and vibration crack the insulation as you test
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat M1428Fuel pull output failure

    The controller has flagged a failure of the fuel pull solenoid output, which usually follows other output faults.· Other
    Stop now

    Causes

    • Coil failed internally
    • Output stage damaged by an earlier fault
    • Wiring fault between the controller and the fuel pull solenoid

    Checks

    1. 1Look for companion codes such as short, open or overcurrent on the same output, including the fuel hold codes that act on the same shut-off; they show how the output failed
    2. 2Inspect the engine harness around the shut-off plug where heat and vibration crack the insulation for rubbing, heat damage and green corrosion in the plugs
    3. 3Check controller power and ground at the plug with the key on and the engine running
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M2402Fuel pull relay error on

    The controller sees the fuel pull relay energised when it is commanded off.· Other
    Check soon

    Causes

    • Heat-damaged relay base
    • Coil wire touching a supply wire
    • Driver in the controller latched on

    Checks

    1. 1Inspect the base in the engine relay block for heat marks, melted plastic and loose terminals; read the fuel pull output codes
    2. 2Remove the fuel pull relay and measure the coil pin voltage with the key on and the output off; any voltage is a driver or a wiring problem
    3. 3Listen to the relay while starting; chatter instead of one firm click points at weak supply voltage rather than the relay itself
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M2403Fuel pull relay error off

    The controller sees the fuel pull relay not energised when it is commanded on.· Other
    Stop now

    Causes

    • Poor socket contact in the engine relay block
    • Open fuse in the engine relay feed that also carries the pull solenoid
    • Chattering relay from a weak supply

    Checks

    1. 1Inspect the socket in the engine relay block for burnt, loose or spread terminals; read the fuel pull output codes
    2. 2Check the fuel pull relay fuse and the feed along the feed to the fuel pull solenoid through the engine relay block with a meter and a test light with the key on
    3. 3Test the relay coil out of the socket; it should show a steady resistance and click when energised
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat H9202Fuel lift pump output error on

    The controller sees the fuel lift pump output switched on when it was commanded off.· Shorted high
    Check soon

    Causes

    • Output wire shorted to a live supply
    • Relay or driver stuck on
    • Controller output stage failed

    Checks

    1. 1Unplug the fuel lift pump output with the key on; if the controller still reads it on, the fault is in the wiring or controller
    2. 2Check the output wire for contact with a power wire along its run
    3. 3Listen and feel for the part energising while it should be off
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat M9202Fuel lift pump error on

    The controller sees the fuel lift pump switched on when it was commanded off.· Shorted high
    Check soon

    Causes

    • Output wire shorted to a live supply
    • Relay or driver stuck on
    • Controller output stage failed

    Checks

    1. 1Unplug the fuel lift pump with the key on; if the controller still reads it on, the fault is in the wiring or controller
    2. 2Check the output wire for contact with a power wire along its run
    3. 3Listen and feel for the part energising while it should be off
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat H9203Fuel lift pump output error off

    The controller sees the fuel lift pump output off when it was commanded on.· Shorted low
    Check soon

    Causes

    • Open or grounded output wire
    • Coil or element failed
    • Blown fuse or missing supply to the circuit

    Checks

    1. 1Check the fuse and supply to the fuel lift pump output circuit with the key on
    2. 2Measure the resistance of the part and look for an open or a short to its body
    3. 3Command the function and measure voltage at the plug; none means a wiring or controller fault
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat M9203Fuel lift pump error off

    The controller sees the fuel lift pump off when it was commanded on.· Shorted low
    Check soon

    Causes

    • Open or grounded output wire
    • Coil or element failed
    • Blown fuse or missing supply to the circuit

    Checks

    1. 1Check the fuse and supply to the fuel lift pump circuit with the key on
    2. 2Measure the resistance of the part and look for an open or a short to its body
    3. 3Command the function and measure voltage at the plug; none means a wiring or controller fault
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat H9287Fuel lift pump protection time-out

    The controller logged the message "Fuel lift pump protection time-out".· Lost message
    Check soon

    Causes

    • Condition the message names is active
    • Wiring or connector problem on the related part
    • Software or programming mismatch

    Checks

    1. 1Read the message in context with any other active code
    2. 2Check the related part and its plug for damage
    3. 3Clear the code and see whether it returns
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Bobcat M9287Fuel pump failure time exceeded

    The controller logged the message "Fuel pump failure time exceeded".· Real condition
    Check soon

    Causes

    • Condition the message names is active
    • Wiring or connector problem on the related part
    • Software or programming mismatch

    Checks

    1. 1Read the message in context with any other active code
    2. 2Check the related part and its plug for damage
    3. 3Clear the code and see whether it returns
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

Shared checks

Checks, in order

  1. 1Key on and listen for the solenoid click and the lift pump running; no click with good voltage at the plug points to the coil.
  2. 2Measure resistance of each solenoid coil separately and compare with the other coil; the pull coil and hold coil do not read the same.
  3. 3Swap the fuel relay with an identical one from the panel and see whether the code and the symptom move with it.
  4. 4Check the fuse for the lift pump circuit and measure voltage at the pump plug while the key is cranked.
  5. 5Look at the harness where it crosses the engine for heat damage and chafing before replacing any solenoid.

Causes

  • Pull or hold coil burnt open or shorted inside the solenoid
  • Relay stuck on or off, or a loose relay socket terminal
  • Harness chafed between the solenoid and the controller
  • Lift pump motor failed or its supply fuse blown

Most common here: shorted high (5 of 22)

Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

When to stop

You'll notice: The engine will not start or stops when the key is released, or it keeps running after key-off, depending on which coil or relay failed.

Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.