EF Logo

Thermo King · Refrigeration system (SR-2/SR-3/SR-4)

Thermo King Fault Code 10

High discharge pressure or temperature

What does Thermo King code 10 mean?

Compressor discharge pressure or temperature went above the limit the controller allows. Continued running risks damaging the compressor and blowing the high pressure cutout. Urgency: stop now - shut down and fix before working on. Check first: look at the condenser coil face and clean it if it is plugged.

FaultStop10Thermo King · Refrigeration system (SR-2/SR-3/SR-4)

Can I keep running with it?

Stop now

Shut down and fix before working on. Running on risks damage or the machine locks out.

What should I check first?

Look at the condenser coil face and clean it if it is plugged

Then 4 more checks
Code shows hereFAULT10

Where this code shows

Press the alarm key or open the Alarms menu on the controller display to list active alarms.

Checks

0 of 5 done

Causes

  • Condenser coil blocked with dirt, leaves or bugs
  • Condenser fan or fan belt not turning properly
  • Overcharge or air or non-condensables in the system
  • Receiver or liquid line restricted

How it failed

You'll notice: Alarm 10 and the unit may shut down or run at reduced capacity.

Shorted highRead from how the source describes the code

The signal sits at or near the supply voltage - more than a working sensor can send.

ControllerPartSupplySignalGround
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.
Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good result
Open circuit (OL) between them. Any low reading is the short.

When to stop

Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.

Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Same part, other failures: Refrigeration pressures, scroll compressor limits, modulation and drive

1 other code on this part is also shorted high (HP). When they show together, start at the wiring and connector they share.

Show the other 14 codes
All 23 Refrigeration pressures, scroll compressor limits, modulation and drive codes on one page

Source

Thermo King Alarm Codes - North America (thermoking.com alarm code list)

This source lists 10 and its meaning. The guidance on this page is general, not taken from it.

The source covers: Thermo King SR-2, SR-3, SR-4 truck and trailer units and related Thermo King controllers (the families the source lists).

Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.