Thermo King · Temperature sensors (SR-2/SR-3/SR-4)
Thermo King Fault Code 04
Check discharge air sensor
What does Thermo King code 04 mean?
The discharge air sensor, which sits in the cold air leaving the evaporator, gives a reading outside its normal range. The controller uses it for modulation and for the cargo-protection limits in chilled loads. Urgency: check soon - the machine may derate or limit a function. Check first: inspect the discharge sensor probe and lead at the evaporator outlet for rubbing or ice damage.
Can I keep running with it?
Check soon
The machine may derate or limit a function. Find the cause before the next shift.
What should I check first?
Inspect the discharge sensor probe and lead at the evaporator outlet for rubbing or ice damage
Then 4 more checksWhere this code shows
Press the alarm key or open the Alarms menu on the controller display to list active alarms.
Checks
0 of 5 done
Causes
- Discharge sensor lead rubbed through against the coil frame or fan housing
- Frost or water in the probe connector
- Sensor element failed open or short
- Pin loose in the main harness plug
How it failed
You'll notice: Alarm 04 appears; in perishable mode the unit loses its low discharge limit, so product can be frozen by overcooling, and the controller may fall back to return air only.
OtherRead from how the source describes the code
The source does not say how this one failed.
- Meter test
- Read the code with the service tool and note which other codes are active with it.
- Good result
- Codes that appear together usually share one cause - start with the wiring they share.
When to stop
Let the engine cool before opening the cooling system; a hot cap releases scalding coolant. Running on with an overheat warning risks a head gasket or seized engine.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Same part, other failures: Evaporator, air and compressor temperature sensors
- P1EReturn air temperature sensor faultOtherCheck soon
- 02Check evaporator coil sensorOtherCheck soon
- P2ERemote return air temperature sensor faultOtherCheck soon
- 03Check return air sensorOtherStop now
- 04Check discharge air sensorOtherCheck soon
- 05Check ambient temperature sensorOtherCheck soon
- 08Unit running on coil sensorOtherCheck soon
- 11Controlling on alternate sensorOtherCheck soon
- 12Sensor or digital input shutdownOtherStop now
Show the other 12 codesHide the other codes
- 13Sensor checkOtherCheck soon
- 47Remote sensor shutdownOtherStop now
- 49Spare sensor 1 checkOtherInformation
- 80Check compressor temperature sensorReal conditionCheck soon
- 81High compressor temperatureOtherCheck soon
- 82High compressor temperature shutdownOtherStop now
- 92Sensor grades not setOtherInformation
- 97Failed remote return air sensor (CR)OtherCheck soon
- 150Sensor out of range lowShorted lowCheck soon
- 151Sensor out of range highOpen circuitCheck soon
- 203Check display return air sensorOtherCheck soon
- 204Check display discharge air sensorOtherCheck soon
Other Thermo King codes: Temperature sensors (SR-2/SR-3/SR-4)
Source
Thermo King Alarm Codes - North America (thermoking.com alarm code list)
This source lists 04 and its meaning. The guidance on this page is general, not taken from it.
The source covers: Thermo King SR-2, SR-3, SR-4 truck and trailer units and related Thermo King controllers (the families the source lists).
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.