Thermo King · Temperature sensors (SR-2/SR-3/SR-4)

Thermo King Fault Code 02

Check evaporator coil sensor

What does Thermo King code 02 mean?

The controller reads the evaporator coil temperature sensor outside its valid range, so it cannot see frost building on the coil. Defrost decisions fall back to timers or other sensors. Urgency: check soon - the machine may derate or limit a function. Check first: find the coil sensor on the evaporator and trace its leads to the unit harness for damage.

FaultCheck02Thermo King · Temperature sensors (SR-2/SR-3/SR-4)

Can I keep running with it?

Check soon

The machine may derate or limit a function. Find the cause before the next shift.

What should I check first?

Find the coil sensor on the evaporator and trace its leads to the unit harness for damage

Then 5 more checks
Code shows hereFAULT02

Where this code shows

Press the alarm key or open the Alarms menu on the controller display to list active alarms.

Checks

0 of 6 done

Causes

  • Coil sensor wire chafed or cut where it leaves the evaporator
  • Sensor connector at the controller corroded or pushed back
  • Sensor probe itself open or shorted internally
  • Water in the splice protected by the heat-shrink at the coil

How it failed

You'll notice: Alarm 02 shows on the display and defrost may start on time alone, so the coil can ice up or defrost too often.

OtherRead from how the source describes the code

The source does not say how this one failed.

Meter test
Read the code with the service tool and note which other codes are active with it.
Good result
Codes that appear together usually share one cause - start with the wiring they share.

When to stop

Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.

Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Same part, other failures: Evaporator, air and compressor temperature sensors

Source

Thermo King Alarm Codes - North America (thermoking.com alarm code list)

This source lists 02 and its meaning. The guidance on this page is general, not taken from it.

The source covers: Thermo King SR-2, SR-3, SR-4 truck and trailer units and related Thermo King controllers (the families the source lists).

Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.