Komatsu · Pump controller
Komatsu Fault Code DA2RMC
CAN circuit break (pump controller connection)
What does Komatsu code DA2RMC mean?
The monitor or engine controller no longer detects the pump controller on the CAN link. The data from the pump controller is lost until the link is restored. Urgency: check soon - the machine may derate or limit a function. Check first: check pump controller supply and ground first.
Can I keep running with it?
Check soon
The machine may derate or limit a function. Find the cause before the next shift.
What should I check first?
Check pump controller supply and ground first
Then 3 more checksWhere this code shows
Watch the monitor for the user code and the caution lamp or buzzer, and write the code down.
Checks
0 of 4 done
Causes
- CAN wire open or shorted between the controllers
- Pump controller without power or ground
- Connector loose at the pump controller
How it failed
You'll notice: Monitor loses pump controller data with DA2RMC; user code E0E in the SINOCMP table.
Lost messageRead from how the source describes the code
A module stopped hearing another on the data link, or the data came late or garbled.
- Meter test
- Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
- Good result
- About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
When to stop
Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Same part, other failures: Controller network, option and GPS codes
1 other code on this part is also lost message (DA29KQ). When they show together, start at the wiring and connector they share.
- DA2RMCCAN circuit break (pump controller connection)Lost messageCheck soon
- D19JKZPersonal code relay abnormalOtherCheck soon
- DA29KQModel selection abnormalLost messageCheck soon
- D862KAGPS antenna circuit breakOpen circuitInformation
Other Komatsu codes: Pump controller
- CA1633KOMNET data link timeout
- DHPAMAFront pump pressure sensor abnormal
- DHPBMARear pump pressure sensor: abnormal
- DHSAMASwing right PPC pressure sensor: abnormal
- DHSBMASwing left PPC pressure sensor: abnormal
- DHSDMABucket dump PPC pressure sensor: abnormal
- DWK0KASecond-stage overflow (relief) solenoid: circuit open
- DWK0KBSecond-stage overflow (relief) solenoid: circuit short
Related on Equipments Finder
Source
SINOCMP - Error Code List for Komatsu PC200-8, PC220-8 and PC220LC-8 Excavators (failure code table)
This source lists DA2RMC and its meaning. The guidance on this page is general, not taken from it.
The source covers: Komatsu PC200-8, PC220-8 and PC220LC-8 excavators (the models the source lists).
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.