Komatsu · Engine controller
Komatsu Fault Code CA1633
KOMNET data link timeout
What does Komatsu code CA1633 mean?
The engine controller stopped getting messages from the machine network (KOMNET data link) within the allowed time. Monitor data and some engine functions can drop out until the link returns. Urgency: check soon - the machine may derate or limit a function. Check first: check the KOMNET data link wires and connectors between the controllers.
Can I keep running with it?
Check soon
The machine may derate or limit a function. Find the cause before the next shift.
What should I check first?
Check the KOMNET data link wires and connectors between the controllers
Then 3 more checksWhere this code shows
Watch the monitor for the user code and the caution lamp or buzzer, and write the code down.
Checks
0 of 4 done
Causes
- Open or shorted data link wire between controllers
- Connector fault at the pump controller or monitor
- Another controller off the network because of a supply fault
How it failed
Lost messageRead from how the source describes the code
A module stopped hearing another on the data link, or the data came late or garbled.
- Meter test
- Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
- Good result
- About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
When to stop
Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Same part, other failures: Engine controller internal and network faults
- CA111Engine controller critical internal errorPart or controllerStop now
- CA757All continuous data lostOtherCheck soon
- 989L00Engine controller lock warning 1OtherCheck soon
- 989M00Engine controller lock warning 2OtherCheck soon
- 989N00Engine controller lock warning 3OtherCheck soon
- CA1633KOMNET data link timeoutLost messageCheck soon
Other Komatsu codes: Engine controller
- DA2RMCCAN circuit break (pump controller connection)
- CA187Sensor power supply 2: low voltage
- CA221Barometric (ambient) pressure sensor: high voltage
- CA222Barometric (ambient) pressure sensor: low voltage
- CA227Sensor power supply 2: high voltage
- CA234Engine overspeed
- CA238Ne speed sensor power supply voltage error
- CA271IMV/PCV1 short circuit
Related on Equipments Finder
Source
SINOCMP - Error Code List for Komatsu PC200-8, PC220-8 and PC220LC-8 Excavators (failure code table)
This source lists CA1633 and its meaning. The guidance on this page is general, not taken from it.
The source covers: Komatsu PC200-8, PC220-8 and PC220LC-8 excavators (the models the source lists).
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?