John Deere · Main controller (MCZ) - solenoids

John Deere Dig, regeneration and travel speed solenoids fault codes

These solenoids change how the machine digs and travels. The dig and arm regenerative solenoids recirculate oil to speed up the arm and boom.

More about these parts

The power dig solenoid (SG, Y24) briefly raises working pressure for hard digging, the travel speed solenoid switches between slow and fast travel, and the arm 2 flow control solenoid (SD) adds flow to the arm. Two further codes report that the 2-speed activation or selector valve solenoid is not detected.

FaultInfoMCZ 11457.02John Deere · Dig, regeneration and travel speed solenoids
Code shows hereFAULTMCZ 11457.02

Where this code shows

Turn the key on and open the monitor's diagnostic/fault screen.

What do these codes mean?

John Deere codes MCZ 11402.02 to MCZ 11948.04 are all about the dig, regeneration and travel speed solenoids. The most common failure type is real condition (8 of 23); none needs an immediate stop. Start with this check: identify the solenoid the code names and unplug that connector only.

How urgent are they?

None of the 23 codes here means stop now; 21 can wait until the shift ends, but find the cause before the next one; 2 are information only.

  • Check soon21
  • Info2

What should I check first?

Identify the solenoid the code names and unplug that connector only

Shared checks

23 of 23

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • John Deere MCZ 11402.02Dig regenerative solenoid feedback current abnormal

    The current feedback of the dig regenerative solenoid (SF, Y22) is abnormal: the controller sees the drive current leaving its allowed band (the list gives above 920 mA and below 70 mA as the limits), so the valve does not move as commanded.· Other
    Check soon

    Causes

    • Faulty coil or damaged wiring at the dig regenerative solenoid (SF, Y22)
    • Corroded or loose connector pin raising the circuit resistance
    • Controller output stage not driving correctly

    Checks

    1. 1Measure the dig regenerative solenoid (SF, Y22) coil resistance at its plug and compare it with the manual value
    2. 2Check the harness and plug for corrosion, oil and pins that are pushed out
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • John Deere MCZ 11402.03Dig regenerative solenoid feedback current high

    The feedback current of the dig regenerative solenoid (SF, Y22) is too high (the list gives above 920 mA), so the coil or its circuit draws more than the controller expects.· Real condition
    Check soon

    Causes

    • Shorted turns inside the dig regenerative solenoid (SF, Y22) coil
    • Harness shorted to battery voltage or to another wire
    • Controller output stage failed on

    Checks

    1. 1Measure the dig regenerative solenoid (SF, Y22) coil resistance; a value far below the manual figure means shorted turns
    2. 2Check the harness for a short to supply or to a neighbouring wire with both ends unplugged
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • John Deere MCZ 11402.04Dig regenerative solenoid feedback current low

    The feedback current of the dig regenerative solenoid (SF, Y22) is too low (the list gives below 70 mA), so the coil or its circuit carries less current than the controller expects.· Real condition
    Check soon

    Causes

    • Open or burnt coil in the dig regenerative solenoid (SF, Y22)
    • Corroded connector or broken wire raising the circuit resistance
    • Controller output stage not driving

    Checks

    1. 1Measure the dig regenerative solenoid (SF, Y22) coil resistance; an open or very high value means a failed coil
    2. 2Check the wires and plug for breaks and corrosion with both ends unplugged
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • John Deere MCZ 11403.02Arm regenerative solenoid feedback current abnormal

    The current feedback of the arm regenerative solenoid (SC, Y23) is abnormal: the controller sees the drive current leaving its allowed band (the list gives above 920 mA and below 70 mA as the limits), so the valve does not move as commanded.· Other
    Check soon

    Causes

    • Faulty coil or damaged wiring at the arm regenerative solenoid (SC, Y23)
    • Corroded or loose connector pin raising the circuit resistance
    • Controller output stage not driving correctly

    Checks

    1. 1Measure the arm regenerative solenoid (SC, Y23) coil resistance at its plug and compare it with the manual value
    2. 2Check the harness and plug for corrosion, oil and pins that are pushed out
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • John Deere MCZ 11403.03Arm regenerative solenoid feedback current high

    The feedback current of the arm regenerative solenoid (SC, Y23) is too high (the list gives above 920 mA), so the coil or its circuit draws more than the controller expects.· Real condition
    Check soon

    Causes

    • Shorted turns inside the arm regenerative solenoid (SC, Y23) coil
    • Harness shorted to battery voltage or to another wire
    • Controller output stage failed on

    Checks

    1. 1Measure the arm regenerative solenoid (SC, Y23) coil resistance; a value far below the manual figure means shorted turns
    2. 2Check the harness for a short to supply or to a neighbouring wire with both ends unplugged
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • John Deere MCZ 11403.04Arm regenerative solenoid feedback current low

    The feedback current of the arm regenerative solenoid (SC, Y23) is too low (the list gives below 70 mA), so the coil or its circuit carries less current than the controller expects.· Real condition
    Check soon

    Causes

    • Open or burnt coil in the arm regenerative solenoid (SC, Y23)
    • Corroded connector or broken wire raising the circuit resistance
    • Controller output stage not driving

    Checks

    1. 1Measure the arm regenerative solenoid (SC, Y23) coil resistance; an open or very high value means a failed coil
    2. 2Check the wires and plug for breaks and corrosion with both ends unplugged
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • John Deere MCZ 11404.02Power dig solenoid feedback current abnormal

    Listed as the power dig solenoid feedback fault.· Other
    Check soon

    Causes

    • Intermittent contact at the Y24 plug: a pushed-out pin or corroded contact lets the current wander
    • Coil on its way out, with resistance drifting as it heats up
    • MCZ output stage driving the Y24 channel unevenly

    Checks

    1. 1Wiggle the Y24 harness and plug while watching the fed-back current on the service screen; a jump when you move it means an intermittent connection
    2. 2Measure the Y24 coil resistance cold, then again after the machine has run warm; a value that drifts points at the coil
    3. 3Look at the Y24 plug for green corrosion and pins that have backed out
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • John Deere MCZ 11404.03Power dig solenoid feedback current high

    Listed as the power dig solenoid feedback fault.· Shorted high
    Check soon

    Causes

    • Shorted turns inside the Y24 coil, lowering its resistance
    • Y24 wire shorted to battery voltage or to a neighbouring wire
    • MCZ output stage stuck on

    Checks

    1. 1Measure the Y24 coil resistance; a value far below the manual figure means shorted turns
    2. 2With both ends unplugged check the Y24 wire for a short to supply or to the next wire in the harness
    3. 3Look for a blown fuse or a hot, discoloured plug at the 3-spool valve unit
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • John Deere MCZ 11404.04Power dig solenoid feedback current low

    Listed as the power dig solenoid feedback fault.· Open circuit
    Check soon

    Causes

    • Open or burnt Y24 coil
    • Broken wire or a corroded pin in the Y24 circuit
    • MCZ output stage not driving the channel

    Checks

    1. 1Measure the Y24 coil resistance; an open or very high value means a failed coil
    2. 2Check continuity of both Y24 wires with both ends unplugged
    3. 3Press the power dig switch and read the commanded current on the service screen; if the command is there but no current flows, the fault is in the wire or coil
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • John Deere MCZ 11405.02Travel speed solenoid feedback current abnormal

    The current feedback of the travel speed solenoid is abnormal: the controller sees the drive current leaving its allowed band, so the valve does not move as commanded.· Other
    Check soon

    Causes

    • Faulty coil or damaged wiring at the travel speed solenoid
    • Corroded or loose connector pin raising the circuit resistance
    • Controller output stage not driving correctly

    Checks

    1. 1Measure the travel speed solenoid coil resistance at its plug and compare it with the manual value
    2. 2Check the harness and plug for corrosion, oil and pins that are pushed out
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • John Deere MCZ 11405.03Travel speed solenoid feedback current high

    The feedback current of the travel speed solenoid is too high, so the coil or its circuit draws more than the controller expects.· Real condition
    Check soon

    Causes

    • Shorted turns inside the travel speed solenoid coil
    • Harness shorted to battery voltage or to another wire
    • Controller output stage failed on

    Checks

    1. 1Measure the travel speed solenoid coil resistance; a value far below the manual figure means shorted turns
    2. 2Check the harness for a short to supply or to a neighbouring wire with both ends unplugged
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • John Deere MCZ 11405.04Travel speed solenoid feedback current low

    The feedback current of the travel speed solenoid is too low, so the coil or its circuit carries less current than the controller expects.· Real condition
    Check soon

    Causes

    • Open or burnt coil in the travel speed solenoid
    • Corroded connector or broken wire raising the circuit resistance
    • Controller output stage not driving

    Checks

    1. 1Measure the travel speed solenoid coil resistance; an open or very high value means a failed coil
    2. 2Check the wires and plug for breaks and corrosion with both ends unplugged
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • John Deere MCZ 11407.023-Spool solenoid valve unit (SG) abnormal feedback

    Listed under the 3-spool solenoid valve unit (SG) name; the same solenoid and the same fault as the power dig codes.· Other
    Check soon

    Causes

    • Intermittent contact at the Y24 plug: a pushed-out pin or corroded contact lets the current wander
    • Coil on its way out, with resistance drifting as it heats up
    • MCZ output stage driving the Y24 channel unevenly

    Checks

    1. 1Wiggle the Y24 harness and plug while watching the fed-back current on the service screen; a jump when you move it means an intermittent connection
    2. 2Measure the Y24 coil resistance cold, then again after the machine has run warm; a value that drifts points at the coil
    3. 3Look at the Y24 plug for green corrosion and pins that have backed out
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • John Deere MCZ 11407.033-Spool solenoid valve unit (SG) feedback high input

    Listed under the 3-spool solenoid valve unit (SG) name; the same solenoid and the same fault as the power dig codes.· Shorted high
    Check soon

    Causes

    • Shorted turns inside the Y24 coil, lowering its resistance
    • Y24 wire shorted to battery voltage or to a neighbouring wire
    • MCZ output stage stuck on

    Checks

    1. 1Measure the Y24 coil resistance; a value far below the manual figure means shorted turns
    2. 2With both ends unplugged check the Y24 wire for a short to supply or to the next wire in the harness
    3. 3Look for a blown fuse or a hot, discoloured plug at the 3-spool valve unit
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • John Deere MCZ 11407.043-Spool solenoid valve unit (SG) feedback low input

    Listed under the 3-spool solenoid valve unit (SG) name; the same solenoid and the same fault as the power dig codes.· Open circuit
    Check soon

    Causes

    • Open or burnt Y24 coil
    • Broken wire or a corroded pin in the Y24 circuit
    • MCZ output stage not driving the channel

    Checks

    1. 1Measure the Y24 coil resistance; an open or very high value means a failed coil
    2. 2Check continuity of both Y24 wires with both ends unplugged
    3. 3Press the power dig switch and read the commanded current on the service screen; if the command is there but no current flows, the fault is in the wire or coil
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • John Deere MCZ 11428.024-Spool solenoid valve unit (SD) abnormal feedback

    The current feedback of the arm 2 flow control solenoid (SD, Y27, 4-spool valve unit) is abnormal: the controller sees the drive current leaving its allowed band (the list gives above 920 mA and below 70 mA as the limits), so the valve does not move as commanded.· Other
    Check soon

    Causes

    • Faulty coil or damaged wiring at the arm 2 flow control solenoid (SD, Y27, 4-spool valve unit)
    • Corroded or loose connector pin raising the circuit resistance
    • Controller output stage not driving correctly

    Checks

    1. 1Measure the arm 2 flow control solenoid (SD, Y27, 4-spool valve unit) coil resistance at its plug and compare it with the manual value
    2. 2Check the harness and plug for corrosion, oil and pins that are pushed out
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • John Deere MCZ 11428.034-Spool solenoid valve unit (SD) feedback high input

    The feedback current of the arm 2 flow control solenoid (SD, Y27, 4-spool valve unit) is too high (the list gives above 920 mA), so the coil or its circuit draws more than the controller expects.· Real condition
    Check soon

    Causes

    • Shorted turns inside the arm 2 flow control solenoid (SD, Y27, 4-spool valve unit) coil
    • Harness shorted to battery voltage or to another wire
    • Controller output stage failed on

    Checks

    1. 1Measure the arm 2 flow control solenoid (SD, Y27, 4-spool valve unit) coil resistance; a value far below the manual figure means shorted turns
    2. 2Check the harness for a short to supply or to a neighbouring wire with both ends unplugged
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • John Deere MCZ 11428.044-Spool solenoid valve unit (SD) feedback low input

    The feedback current of the arm 2 flow control solenoid (SD, Y27, 4-spool valve unit) is too low (the list gives below 70 mA), so the coil or its circuit carries less current than the controller expects.· Real condition
    Check soon

    Causes

    • Open or burnt coil in the arm 2 flow control solenoid (SD, Y27, 4-spool valve unit)
    • Corroded connector or broken wire raising the circuit resistance
    • Controller output stage not driving

    Checks

    1. 1Measure the arm 2 flow control solenoid (SD, Y27, 4-spool valve unit) coil resistance; an open or very high value means a failed coil
    2. 2Check the wires and plug for breaks and corrosion with both ends unplugged
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • John Deere MCZ 11457.022-speed activation solenoid not detected

    The MCZ expects a 2-speed (combined pump flow) solenoid and cannot find it.· Lost message
    Info

    Causes

    • No 2-speed kit fitted but the controller is set up to expect one
    • Open wire or unplugged connector to the 2-speed solenoid
    • Failed solenoid coil
    • Wrong controller option configuration after a controller swap

    Checks

    1. 1Confirm whether the machine really has a 2-speed (combined flow) kit fitted
    2. 2If it has one, unplug the solenoid and measure the coil resistance
    3. 3Check wiring continuity from the solenoid to the MCZ pin
    4. 4If it has none, clear the code and see whether it returns
    5. 5Check the option configuration with the dealer service tool
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • John Deere MCZ 11458.02Selector valve solenoid not detected

    The MCZ cannot find the selector valve solenoid used with the auxiliary high-flow kit.· Lost message
    Info

    Causes

    • No high-flow kit installed but the controller is set up to expect one
    • Unplugged or broken wire to the selector valve solenoid
    • Failed selector solenoid coil
    • Controller configured for the wrong option set

    Checks

    1. 1Check whether the machine has an auxiliary high-flow kit fitted
    2. 2If it does, measure the selector solenoid coil resistance
    3. 3Check the wiring continuity to the MCZ pin and the connector at the valve
    4. 4If there is no kit, clear the code and see whether it returns
    5. 5Check the option configuration with the dealer service tool
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • John Deere MCZ 11948.02Power dig solenoid feedback current abnormal

    A second listing of the power dig solenoid feedback fault, with the same meaning as the other power dig codes.· Other
    Check soon

    Causes

    • Intermittent contact at the Y24 plug: a pushed-out pin or corroded contact lets the current wander
    • Coil on its way out, with resistance drifting as it heats up
    • MCZ output stage driving the Y24 channel unevenly

    Checks

    1. 1Wiggle the Y24 harness and plug while watching the fed-back current on the service screen; a jump when you move it means an intermittent connection
    2. 2Measure the Y24 coil resistance cold, then again after the machine has run warm; a value that drifts points at the coil
    3. 3Look at the Y24 plug for green corrosion and pins that have backed out
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • John Deere MCZ 11948.03Power dig solenoid feedback current high

    A second listing of the power dig solenoid feedback fault, with the same meaning as the other power dig codes.· Shorted high
    Check soon

    Causes

    • Shorted turns inside the Y24 coil, lowering its resistance
    • Y24 wire shorted to battery voltage or to a neighbouring wire
    • MCZ output stage stuck on

    Checks

    1. 1Measure the Y24 coil resistance; a value far below the manual figure means shorted turns
    2. 2With both ends unplugged check the Y24 wire for a short to supply or to the next wire in the harness
    3. 3Look for a blown fuse or a hot, discoloured plug at the 3-spool valve unit
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • John Deere MCZ 11948.04Power dig solenoid feedback current low

    A second listing of the power dig solenoid feedback fault, with the same meaning as the other power dig codes.· Open circuit
    Check soon

    Causes

    • Open or burnt Y24 coil
    • Broken wire or a corroded pin in the Y24 circuit
    • MCZ output stage not driving the channel

    Checks

    1. 1Measure the Y24 coil resistance; an open or very high value means a failed coil
    2. 2Check continuity of both Y24 wires with both ends unplugged
    3. 3Press the power dig switch and read the commanded current on the service screen; if the command is there but no current flows, the fault is in the wire or coil
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

Shared checks

Checks, in order

  1. 1Identify the solenoid the code names and unplug that connector only
  2. 2Measure the coil resistance at the plug and compare it with the manual value
  3. 3Check the harness with both ends unplugged for a break or a short to supply or a neighbouring wire
  4. 4Read commanded current on the service screen while pressing the matching switch; no change means test the switch circuit first
  5. 5Inspect the plug for water, oil and pushed-out pins

Causes

  • Coil open or with shorted turns
  • Wire chafed against the frame or a hose and shorted or broken
  • Corroded or loose connector pin raising the circuit resistance
  • Controller output stage not driving the channel

Most common here: real condition (8 of 23)

Check the real value with a separate gauge or thermometer before blaming the sensor.

When to stop

You'll notice: The function the solenoid controls does not engage or stays engaged: power dig has no effect, travel stays in one speed, or the arm loses its extra speed.

Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.