John Deere · Main controller (MCZ) - pressure sensors
John Deere Boom, arm and bucket pressure sensors fault codes
Seven sensors tell the main controller how hard each front function is being asked to work. B30 reads boom up demand, another boom down demand, and the boom bottom sensor reads piston-side pressure in the boom cylinder for load logic.
More about these partsLess
B31 reads arm in and another arm out; two more read bucket curl and bucket dump. The controller uses them for pump control and regeneration. Each sensor has a signal high and a signal low code.
Where this code shows
Turn the key on and open the monitor's diagnostic/fault screen.
What do these codes mean?
John Deere codes MCZ 11302.03 to MCZ 11998.04 are all about the boom, arm and bucket pressure sensors. The most common failure type is lost message (6 of 14); none needs an immediate stop. Start with this check: find the sensor the code names (boom up, boom down, boom bottom, arm in, arm out, bucket curl or bucket dump) and unplug that one first.
How urgent are they?
None of the 14 codes here means stop now; all 14 can wait until the shift ends, but find the cause before the next one.
- Check soon14
What should I check first?
Find the sensor the code names (boom up, boom down, boom bottom, arm in, arm out, bucket curl or bucket dump) and unplug that one first
Shared checks14 of 14
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
John Deere MCZ 11302.03Boom up pressure sensor (B30) signal high
The main controller reads the boom up pressure sensor (B30) on the boom raise circuit as high. The control logic that uses this pressure becomes unreliable, so the machine may feel weak or jerky. This sensor is on the boom raise line, so a wrong value upsets boom up speed and the pump demand while the boom is raised.· OtherOtherCheck soonCauses
- Short between the B30 signal wire and its 5 V supply wire along the boom side of the harness
- B30 failed high
- B30 return wire open
- Water in the B30 plug leaking from supply to signal
Checks
- 1Unplug B30 and read its harness signal pin with the key on; supply-level voltage on the signal wire points to a short in the harness
- 2Check continuity of the B30 ground wire to the MCZ
- 3Watch the boom up pressure with the boom resting on the ground and no lever movement; it should not show high pressure
- 4Look for rubbed spots on the harness along the boom cylinder
- 5Swap in a good B30 once the wiring is cleared and recheck
- 6Raise the boom and watch the boom up pressure value on the service screen; it should climb with the lever and fall back in neutral.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 11302.04Boom up pressure sensor (B30) signal low
The main controller reads the boom up pressure sensor (B30) on the boom raise circuit as low. The control logic that uses this pressure becomes unreliable, so the machine may feel weak or jerky. This sensor is on the boom raise line, so a wrong value upsets boom up speed and the pump demand while the boom is raised.· OtherOtherCheck soonCauses
- B30 signal wire open from chafing along the boom
- B30 signal wire shorted to the machine frame
- No 5 V at B30 because of a damaged supply wire
- B30 failed low
Checks
- 1Check supply and ground voltage at the unplugged B30 connector with the key on
- 2Measure the signal wire to chassis ground with both ends open to find a short
- 3Test the signal wire for continuity between B30 and the MCZ
- 4Raise the boom against its stop and compare the monitor value with a gauge
- 5Check for a pin that has backed out of the connector
- 6Raise the boom and watch the boom up pressure value on the service screen; it should climb with the lever and fall back in neutral.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 11303.03Arm in pressure sensor (B31) signal high
The main controller reads the arm in pressure sensor (B31) on the arm in circuit as high. The control logic that uses this pressure becomes unreliable, so the machine may feel weak or jerky. This sensor reports the arm in demand for arm regeneration, so arm in may feel slow when it is wrong.· OtherOtherCheck soonCauses
- B31 signal wire shorted to supply in the harness along the arm
- B31 failed high giving full scale
- B31 ground wire open
Checks
- 1With B31 unplugged and key on, measure signal voltage at the plug and compare it with the 5 V supply
- 2Check the sensor ground wire continuity back to the MCZ
- 3Read arm in pressure on the monitor with the arm lever in neutral; a high value with no movement is false
- 4Pull the arm in with the engine running and watch the arm in value rise; a value stuck at one end means the sensor or its wire.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 11303.04Arm in pressure sensor (B31) signal low
The main controller reads the arm in pressure sensor (B31) on the arm in circuit as low. The control logic that uses this pressure becomes unreliable, so the machine may feel weak or jerky. This sensor reports the arm in demand for arm regeneration, so arm in may feel slow when it is wrong.· OtherOtherCheck soonCauses
- Open signal wire between B31 and the MCZ
- B31 signal wire grounded against the arm side frame
- No supply to B31 from a broken wire or loose pin
Checks
- 1Measure 5 V at the B31 supply pin with the key on
- 2Check the B31 signal wire for a short to ground with the connector disconnected
- 3Confirm the signal wire is continuous from B31 to the MCZ while flexing the harness
- 4Pull the arm in with the engine running and watch the arm in value rise; a value stuck at one end means the sensor or its wire.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 11325.03Bucket curl pressure sensor circuit high
The controller reads the bucket curl pressure sensor signal above its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off. This sensor reports the bucket curl command, so a wrong value makes curl slow or the bucket pump control less accurate.· OtherOtherCheck soonCauses
- Signal wire of the bucket curl pressure sensor shorted to the 5 V supply or to battery voltage
- Open return (ground) wire at the bucket curl pressure sensor, which lets the signal float high
- The bucket curl pressure sensor failed internally with a stuck high output
Checks
- 1Unplug the bucket curl pressure sensor and, key on, measure the harness signal pin: a value near 5 V points to a harness short or a controller fault rather than the part
- 2Check continuity of the bucket curl pressure sensor return wire to the controller sensor ground with both ends disconnected
- 3Curl the bucket and watch its value on the service screen; it should rise when you curl and not when you dump.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 11325.04Bucket curl pressure sensor circuit low
The controller reads the bucket curl pressure sensor signal below its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off. This sensor reports the bucket curl command, so a wrong value makes curl slow or the bucket pump control less accurate.· OtherOtherCheck soonCauses
- Signal wire of the bucket curl pressure sensor shorted to ground
- Broken or unplugged 5 V supply wire to the bucket curl pressure sensor
- The bucket curl pressure sensor failed internally with a stuck low output
Checks
- 1With the bucket curl pressure sensor unplugged and the key on, check for the 5 V supply on its harness plug; no supply means a broken feed wire or a faulty controller output
- 2Measure the signal wire to ground with both ends disconnected; a very low resistance means a short to ground in the harness
- 3Curl the bucket and watch its value on the service screen; it should rise when you curl and not when you dump.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 11802.03Boom bottom pressure sensor circuit voltage high
The controller reads the boom bottom pressure sensor signal above its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off. This sensor is on the piston side of the boom cylinder and feeds the boom load logic, so overload relief control relies on it.· Shorted highShorted highCheck soonCauses
- Signal wire of the boom bottom pressure sensor shorted to the 5 V supply or to battery voltage
- Open return (ground) wire at the boom bottom pressure sensor, which lets the signal float high
- The boom bottom pressure sensor failed internally with a stuck high output
Checks
- 1Unplug the boom bottom pressure sensor and, key on, measure the harness signal pin: a value near 5 V points to a harness short or a controller fault rather than the part
- 2Check continuity of the boom bottom pressure sensor return wire to the controller sensor ground with both ends disconnected
- 3Compare the bottom side reading with the boom resting on the ground and then held in the air; it should change with the load.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
John Deere MCZ 11802.04Boom bottom pressure sensor circuit voltage low
The controller reads the boom bottom pressure sensor signal below its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off. This sensor is on the piston side of the boom cylinder and feeds the boom load logic, so overload relief control relies on it.· Shorted lowShorted lowCheck soonCauses
- Signal wire of the boom bottom pressure sensor shorted to ground
- Broken or unplugged 5 V supply wire to the boom bottom pressure sensor
- The boom bottom pressure sensor failed internally with a stuck low output
Checks
- 1With the boom bottom pressure sensor unplugged and the key on, check for the 5 V supply on its harness plug; no supply means a broken feed wire or a faulty controller output
- 2Measure the signal wire to ground with both ends disconnected; a very low resistance means a short to ground in the harness
- 3Compare the bottom side reading with the boom resting on the ground and then held in the air; it should change with the load.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
John Deere MCZ 11995.03Arm out pressure sensor circuit high
The controller reads the arm out pressure sensor signal above its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off. This sensor reports the arm out demand, the counterpart of the arm in sensor, so arm out speed can suffer.· Lost messageLost messageCheck soonCauses
- Signal wire of the arm out pressure sensor shorted to the 5 V supply or to battery voltage
- Open return (ground) wire at the arm out pressure sensor, which lets the signal float high
- The arm out pressure sensor failed internally with a stuck high output
Checks
- 1Unplug the arm out pressure sensor and, key on, measure the harness signal pin: a value near 5 V points to a harness short or a controller fault rather than the part
- 2Check continuity of the arm out pressure sensor return wire to the controller sensor ground with both ends disconnected
- 3Push the arm out and watch the arm out value follow the lever; compare it with the arm in sensor, which reads the other direction.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
John Deere MCZ 11995.04Arm out pressure sensor circuit low
The controller reads the arm out pressure sensor signal below its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off. This sensor reports the arm out demand, the counterpart of the arm in sensor, so arm out speed can suffer.· Lost messageLost messageCheck soonCauses
- Signal wire of the arm out pressure sensor shorted to ground
- Broken or unplugged 5 V supply wire to the arm out pressure sensor
- The arm out pressure sensor failed internally with a stuck low output
Checks
- 1With the arm out pressure sensor unplugged and the key on, check for the 5 V supply on its harness plug; no supply means a broken feed wire or a faulty controller output
- 2Measure the signal wire to ground with both ends disconnected; a very low resistance means a short to ground in the harness
- 3Push the arm out and watch the arm out value follow the lever; compare it with the arm in sensor, which reads the other direction.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
John Deere MCZ 11997.03Bucket dump pressure sensor circuit high
The controller reads the bucket dump pressure sensor signal above its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off. This sensor reports the bucket dump command, the counterpart of curl, so a wrong value can make dumping slow or uneven.· Lost messageLost messageCheck soonCauses
- Signal wire of the bucket dump pressure sensor shorted to the 5 V supply or to battery voltage
- Open return (ground) wire at the bucket dump pressure sensor, which lets the signal float high
- The bucket dump pressure sensor failed internally with a stuck high output
Checks
- 1Unplug the bucket dump pressure sensor and, key on, measure the harness signal pin: a value near 5 V points to a harness short or a controller fault rather than the part
- 2Check continuity of the bucket dump pressure sensor return wire to the controller sensor ground with both ends disconnected
- 3Dump the bucket and watch its value rise; a reading that rises on curl as well means the plugs are swapped.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
John Deere MCZ 11997.04Bucket dump pressure sensor circuit low
The controller reads the bucket dump pressure sensor signal below its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off. This sensor reports the bucket dump command, the counterpart of curl, so a wrong value can make dumping slow or uneven.· Lost messageLost messageCheck soonCauses
- Signal wire of the bucket dump pressure sensor shorted to ground
- Broken or unplugged 5 V supply wire to the bucket dump pressure sensor
- The bucket dump pressure sensor failed internally with a stuck low output
Checks
- 1With the bucket dump pressure sensor unplugged and the key on, check for the 5 V supply on its harness plug; no supply means a broken feed wire or a faulty controller output
- 2Measure the signal wire to ground with both ends disconnected; a very low resistance means a short to ground in the harness
- 3Dump the bucket and watch its value rise; a reading that rises on curl as well means the plugs are swapped.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
John Deere MCZ 11998.03Boom down pressure sensor circuit high
The controller reads the boom down pressure sensor signal above its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off. This sensor is on the boom lower line, so a wrong value can make lowering jerky or switch off the boom regeneration.· Lost messageLost messageCheck soonCauses
- Signal wire of the boom down pressure sensor shorted to the 5 V supply or to battery voltage
- Open return (ground) wire at the boom down pressure sensor, which lets the signal float high
- The boom down pressure sensor failed internally with a stuck high output
Checks
- 1Unplug the boom down pressure sensor and, key on, measure the harness signal pin: a value near 5 V points to a harness short or a controller fault rather than the part
- 2Check continuity of the boom down pressure sensor return wire to the controller sensor ground with both ends disconnected
- 3Lower the boom slowly and confirm the boom down value rises only while the lever is held down.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
John Deere MCZ 11998.04Boom down pressure sensor circuit low
The controller reads the boom down pressure sensor signal below its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off. This sensor is on the boom lower line, so a wrong value can make lowering jerky or switch off the boom regeneration.· Lost messageLost messageCheck soonCauses
- Signal wire of the boom down pressure sensor shorted to ground
- Broken or unplugged 5 V supply wire to the boom down pressure sensor
- The boom down pressure sensor failed internally with a stuck low output
Checks
- 1With the boom down pressure sensor unplugged and the key on, check for the 5 V supply on its harness plug; no supply means a broken feed wire or a faulty controller output
- 2Measure the signal wire to ground with both ends disconnected; a very low resistance means a short to ground in the harness
- 3Lower the boom slowly and confirm the boom down value rises only while the lever is held down.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Shared checks
Checks, in order
- 1Find the sensor the code names (boom up, boom down, boom bottom, arm in, arm out, bucket curl or bucket dump) and unplug that one first
- 2Key on, measure the unplugged sensor signal pin: near 5 V means a short to the feed, near 0 V means a short to ground or a broken signal wire
- 3Operate the function with the engine running and watch its live pressure value; it should rise and fall with the lever, not sit pegged
- 4Check the return wire to the MCZ sensor ground for continuity with both ends disconnected
- 5Inspect the plug for corrosion, oil and pushed-out pins, and the harness for rub-through at boom and arm clamps
Causes
- Sensor failed inside and giving a fixed full-scale or zero signal
- Signal wire rubbed through where the harness runs along the boom or arm
- Plug backed out or full of water on the boom or arm, where sensors are exposed to washing and vibration
- Broken return wire, so the signal floats up toward the supply voltage
Most common here: lost message (6 of 14)
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
When to stop
You'll notice: The function named in the code can feel slow or uneven, regeneration help may be lost, and boom load controls such as overload relief logic may stop working correctly.
Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.