These are the actuators that control the engine from the module: the throttle actuator, the fuel actuator or shutoff, and on dual fuel machines the LP gas lock and start assist solenoids. The module drives each and monitors its output.

FaultCheck3352JLG · LP Lock
Code shows hereFAULT3352

Where this code shows

Turn the key on and watch the fault lamp or platform display.

What do these codes mean?

JLG codes 3352 to 33132 are all about the throttle, fuel actuator and LP gas solenoids. The most common failure type is shorted high (4 of 15); none needs an immediate stop. Start with this check: command the actuator from the analyzer and watch or listen for movement.

How urgent are they?

None of the 15 codes here means stop now; all 15 can wait until the shift ends, but find the cause before the next one.

  • Check soon15

What should I check first?

Command the actuator from the analyzer and watch or listen for movement

Shared checks

15 of 15

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • LP Lock3 codes

    • JLG 3352LP Lock: Short to ground

      The controller sees the lp lock output pulled low while it is commanded on, so the circuit is shorted to ground.· Shorted low
      Check soon

      Causes

      • LP lock-off solenoid coil shorted to its case
      • LP lock-off coil cooked by the regulator heat until it shorts, so the gas supply cannot be opened
      • Signal wire rubbed bare on metal near the hot engine and exhaust, where wire insulation hardens and cracks
      • Wet or corroded plug, since the lock-off connector sits beside the hot regulator, where the plug insulation turns brittle

      Checks

      1. 1Pull the plug on the LPG regulator beside the engine and recycle EMS to see whether the code stays
      2. 2Meter between the signal pin and chassis with the plug apart; a reading shows the earth path, probably near the hot engine and exhaust, where wire insulation hardens and cracks
      3. 3With the analyzer open, switch to LP fuel with the key on and listen for the lock-off to click open and watch the output state
      4. 4Close the LP tank valve before touching the coil, then meter the coil to its case
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

    • JLG 3353LP Lock: Open circuit

      The controller drives the lp lock output but feedback shows an open circuit (feedback reads high while the output is off).· Open circuit
      Check soon

      Causes

      • Open winding in the coil
      • LP lock-off coil open, so the lock-off never opens and the engine runs out of gas on LP
      • Harness fatigued and parted near the hot engine and exhaust, where wire insulation hardens and cracks
      • Corroded or open terminal in the plug; the lock-off connector sits beside the hot regulator, where the plug insulation turns brittle

      Checks

      1. 1Read the coil resistance at the connector on the LPG regulator beside the engine; no reading means a burnt winding
      2. 2Check continuity from the module output pin to the plug, wiggling the wire as you test, starting near the hot engine and exhaust, where wire insulation hardens and cracks
      3. 3Command the output from the analyzer and switch to LP fuel with the key on and listen for the lock-off to click open
      4. 4Switch to petrol if the engine allows it: if the machine runs, the engine side is fine and only the LP lock-off circuit is open
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

      Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

    • JLG 3354LP Lock: Short to battery

      The controller reads battery voltage on the lp lock output while it is commanded off, so the circuit is shorted to battery.· Shorted high
      Check soon

      Causes

      • Supply leaking onto the output wire through damaged insulation
      • LP lock-off wire shorted to a supply feed so the lock-off is held open with LP deselected
      • Harness rubbed bare and touching a feed near the hot engine and exhaust, where wire insulation hardens and cracks
      • Bent terminal touching the supply pin, because the lock-off connector sits beside the hot regulator, where the plug insulation turns brittle

      Checks

      1. 1Unplug the load on the LPG regulator beside the engine and read the signal wire with the key on; it should be zero while off
      2. 2Look for a wire crossing a live feed near the hot engine and exhaust, where wire insulation hardens and cracks, and separate or replace it
      3. 3Watch the analyzer output as you switch to LP fuel with the key on and listen for the lock-off to click open
      4. 4With the key on and LP deselected, check the lock-off wire for voltage; any reading means the output is held on
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

  • LP Start Assist3 codes

    • JLG 3355LP Start Assist: Short to ground

      The controller sees the lp start assist output pulled low while it is commanded on, so the circuit is shorted to ground.· Shorted low
      Check soon

      Causes

      • LP start assist solenoid coil shorted to its case
      • Start assist coil shorted to its case, cooked by regulator heat
      • Signal wire rubbed bare on metal close to the engine bay heat, where wire sheathing hardens
      • Wet or corroded plug, since the start assist connector lives beside the hot LPG regulator, so the plastic cracks with age

      Checks

      1. 1Unplug the LP start assist beside the LPG regulator; if the code clears the solenoid coil is the short, if not the wiring or module is
      2. 2Meter the signal wire to the frame, flexing it close to the engine bay heat, where wire sheathing hardens for a reading that comes and goes
      3. 3With the analyzer open, crank the engine on LP fuel and listen for the assist solenoid to click and watch the output state
      4. 4Meter the start assist coil to its case with the plug off and the LP tank closed
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

    • JLG 3356LP Start Assist: Open circuit

      The controller drives the lp start assist output but feedback shows an open circuit (feedback reads high while the output is off).· Open circuit
      Check soon

      Causes

      • Open winding in the coil
      • Start assist coil open, so there is no extra gas when cranking on LP and cold starts drag on
      • Wire work-hardened and snapped inside its sheath close to the engine bay heat, where wire sheathing hardens
      • Terminal worn loose in its housing (the start assist connector lives beside the hot LPG regulator, so the plastic cracks with age)

      Checks

      1. 1Ohm the solenoid coil beside the LPG regulator with the plug off and compare with a matching good coil
      2. 2Test both wires with the plug off and flex them close to the engine bay heat, where wire sheathing hardens to catch a hidden break
      3. 3Crank the engine on LP fuel and listen for the assist solenoid to click; the analyzer should show the module sending the command
      4. 4Crank on LP with the plug on a known good load or test lamp to confirm the module is sending the signal
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

      Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

    • JLG 3357LP Start Assist: Short to battery

      The controller reads battery voltage on the lp start assist output while it is commanded off, so the circuit is shorted to battery.· Shorted high
      Check soon

      Causes

      • Supply leaking onto the output wire through damaged insulation
      • Start assist wire touching a supply feed so the assist is held on after the engine has started
      • Damaged sheath close to the engine bay heat, where wire sheathing hardens, exposing the wire to a live one
      • Wet plug bridging the signal pin to supply, since the start assist connector lives beside the hot LPG regulator, so the plastic cracks with age

      Checks

      1. 1With the LP start assist plug off beside the LPG regulator and the key on, measure the output wire to ground; any voltage means a short to supply
      2. 2Trace the wire alongside any supply wire and look for a touch point close to the engine bay heat, where wire sheathing hardens
      3. 3Watch the analyzer output as you crank the engine on LP fuel and listen for the assist solenoid to click
      4. 4Run the engine on LP and note whether the engine runs rich or hunts, which points at an assist stuck on
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

  • Fuel Actuator3 codes

    • JLG 4326Fuel Actuator: Short to ground

      The controller sees the fuel actuator output pulled low while it is commanded on, so the circuit is shorted to ground.· Shorted low
      Check soon

      Causes

      • Winding broken down to earth
      • Fuel actuator coil shorted, cooked by engine heat, so engine speed cannot be set
      • Wire chafed through to the frame on the diesel engine near the injection pump, where fuel and heat soak the loom
      • Dirt and water bridging a pin to ground; the actuator plug is on the diesel engine, where heat and vibration crack the housing

      Checks

      1. 1Unplug the fuel actuator on the diesel engine; if the code clears the solenoid coil is the short, if not the wiring or module is
      2. 2Meter between the signal pin and chassis with the plug apart; a reading shows the earth path, probably on the diesel engine near the injection pump, where fuel and heat soak the loom
      3. 3Start the diesel, ask for more speed and watch the actuator move the fuel rack; the analyzer output should go to supply, not stay at zero
      4. 4Meter the fuel actuator coil to its case and look at the harness for burnt sheathing
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

    • JLG 4327Fuel Actuator: Open circuit

      The controller drives the fuel actuator output but feedback shows an open circuit (feedback reads high while the output is off).· Open circuit
      Check soon

      Causes

      • Coil gone open from heat or age
      • Fuel actuator coil open, so the engine cannot be set to a speed and may stall
      • Lead stretched or kinked until it broke on the diesel engine near the injection pump, where fuel and heat soak the loom
      • Corroded or open terminal in the plug; the actuator plug is on the diesel engine, where heat and vibration crack the housing

      Checks

      1. 1Read the coil resistance at the connector on the diesel engine; no reading means a burnt winding
      2. 2Meter the wires end to end while someone moves the harness on the diesel engine near the injection pump, where fuel and heat soak the loom
      3. 3Command the output from the analyzer and start the diesel, ask for more speed and watch the actuator move the fuel rack
      4. 4Watch the actuator arm while a function is commanded; if it never moves the circuit is open
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

      Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

    • JLG 4328Fuel Actuator: Short to battery

      The controller reads battery voltage on the fuel actuator output while it is commanded off, so the circuit is shorted to battery.· Shorted high
      Check soon

      Causes

      • Lead rubbed through against a live cable
      • Fuel actuator wire touching a live feed, so the engine is held at one speed
      • Melted insulation on the diesel engine near the injection pump, where fuel and heat soak the loom
      • Bent terminal touching the supply pin, because the actuator plug is on the diesel engine, where heat and vibration crack the housing

      Checks

      1. 1Unplug the load on the diesel engine and read the signal wire with the key on; it should be zero while off
      2. 2Trace the wire alongside any supply wire and look for a touch point on the diesel engine near the injection pump, where fuel and heat soak the loom
      3. 3Watch the analyzer output as you start the diesel, ask for more speed and watch the actuator move the fuel rack
      4. 4Check whether the engine runs fast with no function selected
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

  • Fuel actuator2 codes

    • JLG 4329Fuel actuator: Current feedback reading too low

      The measured coil current on the fuel actuator circuit is lower than commanded, so the controller cannot trust that output.· Real condition
      Check soon

      Causes

      • Coil resistance drifted high from years of heat cycling
      • Resistance added by a corroded plug; the actuator plug sits on the diesel engine under heat and vibration
      • Weak battery or poor ground lowering the supply under load
      • Fuel actuator coil resistance high from engine heat, so the engine does not reach the speed commanded and hunts

      Checks

      1. 1Unplug the fuel actuator coil on the diesel engine and ohm each coil; a reading far from its twin shows the weak one
      2. 2Inspect the plug for pushed-back pins and heat marks, then measure the coil supply under command
      3. 3Measure the module supply with the engine loaded to see whether it sags
      4. 4With the analyzer open, run the engine, select a function and watch the fuel actuator current in the analyzer
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

    • JLG 4330Fuel actuator: Current feedback reading lost

      The measured coil current on the fuel actuator circuit is not being read at all, so the controller cannot trust that output.· Other
      Check soon

      Causes

      • Open fuel actuator coil circuit, so no current can flow to measure
      • Feedback pin backed out of the module connector
      • Ground module reading zero on this channel after a surge
      • Fuel actuator feedback lead open in the engine loom, so the module cannot see the actuator current and may shut the engine down

      Checks

      1. 1Take the plug off on the diesel engine and read the coil across its pins
      2. 2Test the sense lead for a break by flexing it while metering
      3. 3Inspect the module plug for a feedback pin that has worked loose
      4. 4Check in the analyzer whether any current reading appears when you run the engine, select a function and watch the fuel actuator current in the analyzer
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Throttle Actuator3 codes

    • JLG 33130Throttle Actuator: Short to ground

      The controller sees the throttle actuator output pulled low while it is commanded on, so the circuit is shorted to ground.· Shorted low
      Check soon

      Causes

      • Throttle actuator solenoid coil shorted to its case
      • Throttle actuator coil shorted, cooked by engine heat, so the engine cannot be sped up
      • Harness pinched against the frame at the engine where the actuator arm and linkage rub on the loom
      • Damaged plug seal, which matters because the actuator plug is on the engine, where heat and vibration crack the housing

      Checks

      1. 1Pull the plug on the engine and recycle EMS to see whether the code stays
      2. 2Meter between the signal pin and chassis with the plug apart; a reading shows the earth path, probably at the engine where the actuator arm and linkage rub on the loom
      3. 3Watch the output on the analyzer as you select a function and watch the actuator arm pull the throttle linkage
      4. 4Meter the actuator coil to its case and look at the engine harness for burnt sheathing
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

    • JLG 33131Throttle Actuator: Open circuit

      The controller drives the throttle actuator output but feedback shows an open circuit (feedback reads high while the output is off).· Open circuit
      Check soon

      Causes

      • Open winding in the coil
      • Throttle actuator coil open, so the engine stays at idle whatever function is selected
      • Harness fatigued and parted at the engine where the actuator arm and linkage rub on the loom
      • Corroded or open terminal in the plug; the actuator plug is on the engine, where heat and vibration crack the housing

      Checks

      1. 1Read the coil resistance at the connector on the engine; no reading means a burnt winding
      2. 2Meter the wires end to end while someone moves the harness at the engine where the actuator arm and linkage rub on the loom
      3. 3With the analyzer open, select a function and watch the actuator arm pull the throttle linkage; if the output switches but nothing happens, the solenoid coil is open
      4. 4Watch the throttle arm while a function is commanded; if it does not move the circuit or actuator is open
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

      Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

    • JLG 33132Throttle Actuator: Short to battery

      The controller reads battery voltage on the throttle actuator output while it is commanded off, so the circuit is shorted to battery.· Shorted high
      Check soon

      Causes

      • Output wire touching a battery-fed wire where two harness legs cross
      • Throttle actuator wire touching a live feed so the engine is held at high speed
      • Melted insulation at the engine where the actuator arm and linkage rub on the loom
      • Crushed pin touching a live neighbour; the actuator plug is on the engine, where heat and vibration crack the housing

      Checks

      1. 1Pull the plug on the engine, key on, and check the output wire for voltage; if it stays with the load off, suspect the module
      2. 2Trace the wire alongside any supply wire and look for a touch point at the engine where the actuator arm and linkage rub on the loom
      3. 3Watch the analyzer output as you select a function and watch the actuator arm pull the throttle linkage
      4. 4Check whether the engine races at start; if it does, the actuator wire is held on
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

  • Other codes1 code

    • JLG 4313Throttle actuator failure

      The controller finds the throttle actuator is not doing what it was commanded, so engine speed control cannot be trusted.· Other
      Check soon

      Causes

      • Actuator or linkage binding
      • Actuator coil or wiring faulty

      Checks

      1. 1Command the throttle from the analyzer and watch the linkage
      2. 2Check the linkage moves freely and the coil reads normally
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

Shared checks

Checks, in order

  1. 1Command the actuator from the analyzer and watch or listen for movement
  2. 2Ohm the actuator coil or motor against its partner or the manual value
  3. 3Check the connector and harness for chafing and corrosion
  4. 4Check the supply voltage at the actuator while it is commanded
  5. 5Replace the actuator or repair the wiring and retest

Causes

  • Actuator seized, sticky or open in its winding
  • Wiring damaged or connector corroded at the actuator
  • Supply voltage low at the actuator
  • Output driver in the module at fault

Most common here: shorted high (4 of 15)

Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

When to stop

You'll notice: The engine will not hold speed, will not start or will not stop, or cannot run on LP gas, and the code names the actuator.

Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.