JCB · Aftertreatment ECU - SCR / DEF
JCB DEF quality, quality sensor temperature and SCR efficiency fault codes
The quality sensor checks the DEF concentration and temperature. Wrong concentration, from water or another fluid, triggers inducement.
More about these partsLess
These codes report that the SCR catalyst is not cutting NOx as expected or is blocked.
Where this code shows
Switch the key on and note any warning lamp or fault icon on the cluster.
What do these codes mean?
JCB codes P207F-00 to P3425 are all about the dEF quality, quality sensor temperature and SCR efficiency. The most common failure type is real condition (6 of 19); none needs an immediate stop. Start with this check: check the DEF with a refractometer (on the DEF quality sensor, with the diagnostic tool and a multimeter).
How urgent are they?
None of the 19 codes here means stop now; all 19 can wait until the shift ends, but find the cause before the next one.
- Check soon19
What should I check first?
Check the DEF with a refractometer (on the DEF quality sensor, with the diagnostic tool and a multimeter)
Shared checks19 of 19
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
JCB P207F-00DEF quality error
The aftertreatment system reports poor DEF quality, usually found after a refill. The system may keep the warning on and later restrict engine power if the fluid is not corrected.· Real conditionReal conditionCheck soonCauses
- Diluted DEF or water added to the tank
- Wrong fluid, such as plain water or contaminated fluid, in the DEF tank
- Old DEF that has degraded after long storage or heat
- Quality sensor faulty or its wiring damaged
- DEF contaminated by dirt from a dirty funnel or container
Checks
- 1Sample the DEF and check it with a refractometer for the correct concentration
- 2Drain and flush the tank and refill with fresh DEF if the sample fails
- 3Check the DEF container and funnel were clean and sealed
- 4Check the DEF quality sensor connector and wiring
- 5Check the fluid date and storage conditions of the container
- 6Clear the fault after refilling and run the system to confirm it passes
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
JCB P207F-86DEF concentration message error from head unit (invalid signal)
DEF concentration message error from head unit (invalid signal). The controller did not receive a valid message or lost contact on the bus, so data for the DEF quality sensor is missing or unreliable.· Lost messageLost messageCheck soonCauses
- CAN wiring open, shorted or wet at a connector
- The sending module not powered, reset or faulty
Checks
- 1Check the CAN high and low wiring and the 120 ohm termination
- 2Check that the sending module has power, earth and no active faults of its own
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB P207F-87DEF quality message error from head unit
DEF quality message error from head unit. The controller did not receive a valid message or lost contact on the bus, so data for the DEF quality sensor is missing or unreliable.· Lost messageLost messageCheck soonCauses
- CAN wiring open, shorted or wet at a connector
- The sending module not powered, reset or faulty
Checks
- 1Check the CAN high and low wiring and the 120 ohm termination
- 2Check that the sending module has power, earth and no active faults of its own
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB P2000-00SCR conversion efficiency below threshold
The SCR catalyst is not converting enough NOx, measured by the downstream NOx sensor. The operator sees an SCR warning, and the machine may derate if the efficiency stays low.· OtherOtherCheck soonCauses
- Poor DEF quality or low DEF dosing
- Dosing valve blocked or dosing too little
- Downstream NOx sensor faulty or dirty
Checks
- 1Check the DEF quality with a refractometer before anything else
- 2Inspect the dosing valve nozzle for crystals and test the dosing output
- 3Check both NOx sensors for faults and read their live values
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P2000-02SCR conversion efficiency below threshold
SCR conversion efficiency below threshold. The controller sees the SCR conversion efficiency below threshold behaving outside what it expects, so it logs a range, plausibility or performance fault.· Erratic or implausibleErratic or implausibleCheck soonCauses
- SCR conversion efficiency below threshold drifting or worn so it no longer matches the real condition
- Poor connection or high resistance in the SCR conversion efficiency below threshold circuit
- A related fault elsewhere making this reading look wrong
Checks
- 1Compare the SCR conversion efficiency below threshold value on live data with a known good value or a reference gauge
- 2Check the SCR conversion efficiency below threshold connector and wiring for high resistance and intermittent contact
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
JCB P2000-04SCR conversion efficiency below threshold (system internal failure)
SCR conversion efficiency below threshold (system internal failure). The controller sees the SCR conversion efficiency below threshold behaving outside what it expects, so it logs a range, plausibility or performance fault.· Erratic or implausibleErratic or implausibleCheck soonCauses
- SCR conversion efficiency below threshold drifting or worn so it no longer matches the real condition
- Poor connection or high resistance in the SCR conversion efficiency below threshold circuit
- A related fault elsewhere making this reading look wrong
Checks
- 1Compare the SCR conversion efficiency below threshold value on live data with a known good value or a reference gauge
- 2Check the SCR conversion efficiency below threshold connector and wiring for high resistance and intermittent contact
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
JCB P2000-06SCR conversion efficiency below threshold
SCR conversion efficiency below threshold. The controller sees the SCR conversion efficiency below threshold behaving outside what it expects, so it logs a range, plausibility or performance fault.· Erratic or implausibleErratic or implausibleCheck soonCauses
- SCR conversion efficiency below threshold drifting or worn so it no longer matches the real condition
- Poor connection or high resistance in the SCR conversion efficiency below threshold circuit
- A related fault elsewhere making this reading look wrong
Checks
- 1Compare the SCR conversion efficiency below threshold value on live data with a known good value or a reference gauge
- 2Check the SCR conversion efficiency below threshold connector and wiring for high resistance and intermittent contact
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
JCB P3401-87Excessive SCR catalyst DEF temperature error
Excessive SCR catalyst DEF temperature error. The reading or voltage for the excessive SCR catalyst DEF temperature is above the allowed range, so the controller treats the signal as unreliable.· OtherOtherCheck soonCauses
- Excessive SCR catalyst DEF temperature signal pulled high by a short to the 5 V reference or supply
- Sensor or part failed giving a high reading
Checks
- 1Read the excessive SCR catalyst DEF temperature value on live data and compare it with the expected value
- 2Unplug the excessive SCR catalyst DEF temperature and check the signal wire for a short to 5 V or battery
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P3402-87DEF concentration too high
DEF concentration too high. The reading or voltage for the DEF concentration too is above the allowed range, so the controller treats the signal as unreliable.· Real conditionReal conditionCheck soonCauses
- DEF concentration too signal pulled high by a short to the 5 V reference or supply
- Sensor or part failed giving a high reading
Checks
- 1Read the DEF concentration too value on live data and compare it with the expected value
- 2Unplug the DEF concentration too and check the signal wire for a short to 5 V or battery
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
JCB P3403-87DEF concentration too low
DEF concentration too low. The reading or voltage for the DEF concentration too is below the allowed range, so the controller treats the signal as unreliable.· Real conditionReal conditionCheck soonCauses
- DEF concentration too signal pulled low by a short to ground or an open supply
- Sensor or part failed giving a low reading
Checks
- 1Read the DEF concentration too value on live data and compare it with the expected value
- 2Unplug the DEF concentration too and check the signal wire for a short to ground and the supply for 5 V
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
JCB P3404-87Excessive DEF temperature in SCR system
Excessive DEF temperature in SCR system. The reading or voltage for the excessive DEF temperature in SCR system is above the allowed range, so the controller treats the signal as unreliable.· OtherOtherCheck soonCauses
- Excessive DEF temperature in SCR system signal pulled high by a short to the 5 V reference or supply
- Sensor or part failed giving a high reading
Checks
- 1Read the excessive DEF temperature in SCR system value on live data and compare it with the expected value
- 2Unplug the excessive DEF temperature in SCR system and check the signal wire for a short to 5 V or battery
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P3405-87DEF temperature too high for SCR catalyst
DEF temperature too high for SCR catalyst. The reading or voltage for the DEF temperature too high for SCR catalyst is above the allowed range, so the controller treats the signal as unreliable.· Real conditionReal conditionCheck soonCauses
- DEF temperature too high for SCR catalyst signal pulled high by a short to the 5 V reference or supply
- Sensor or part failed giving a high reading
Checks
- 1Read the DEF temperature too high for SCR catalyst value on live data and compare it with the expected value
- 2Unplug the DEF temperature too high for SCR catalyst and check the signal wire for a short to 5 V or battery
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
JCB P3406-87DEF temperature too low for SCR catalyst
DEF temperature too low for SCR catalyst. The reading or voltage for the DEF temperature too low for SCR catalyst is below the allowed range, so the controller treats the signal as unreliable.· Real conditionReal conditionCheck soonCauses
- DEF temperature too low for SCR catalyst signal pulled low by a short to ground or an open supply
- Sensor or part failed giving a low reading
Checks
- 1Read the DEF temperature too low for SCR catalyst value on live data and compare it with the expected value
- 2Unplug the DEF temperature too low for SCR catalyst and check the signal wire for a short to ground and the supply for 5 V
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
JCB P3407-87DEF temperature sensor open circuit
DEF temperature sensor open circuit. The controller finds no current path in the DEF temperature sensor circuit, so the DEF quality sensor cannot be driven or read as expected.· Open circuitOpen circuitCheck soonCauses
- Open wire or pushed-back pin between the controller and the DEF temperature sensor
- DEF temperature sensor coil, element or sensor internally open
Checks
- 1Unplug the DEF temperature sensor and measure across its pins, an open reading means the part is faulty
- 2Check continuity of each wire from the DEF temperature sensor plug to the controller pin
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
JCB P3408-87SCR DEF temperature sensor short circuit
SCR DEF temperature sensor short circuit. The controller found the SCR DEF temperature sensor output or circuit shorted and drawing too much current, so it protects the driver.· Short circuitShort circuitCheck soonCauses
- SCR DEF temperature sensor coil shorted internally, drawing too much current
- Harness chafed through and touching the frame or a supply wire near the SCR DEF temperature sensor
- Water in the SCR DEF temperature sensor connector
Checks
- 1Unplug the SCR DEF temperature sensor and measure its resistance, looking for a very low reading
- 2Check each wire for a short to ground and to battery with the plug removed
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.
Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.
JCB P3409-87Excessive ambient or operating level error for DEF properties
Excessive ambient or operating level error for DEF properties. The reading or voltage for the excessive ambient or operating level error for DEF properties is above the allowed range, so the controller treats the signal as unreliable.· OtherOtherCheck soonCauses
- Excessive ambient or operating level error for DEF properties signal pulled high by a short to the 5 V reference or supply
- Sensor or part failed giving a high reading
Checks
- 1Read the excessive ambient or operating level error for DEF properties value on live data and compare it with the expected value
- 2Unplug the excessive ambient or operating level error for DEF properties and check the signal wire for a short to 5 V or battery
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P3410-87DEF level too high
DEF level too high. The reading or voltage for the DEF level too is above the allowed range, so the controller treats the signal as unreliable.· Real conditionReal conditionCheck soonCauses
- DEF level too signal pulled high by a short to the 5 V reference or supply
- Sensor or part failed giving a high reading
Checks
- 1Read the DEF level too value on live data and compare it with the expected value
- 2Unplug the DEF level too and check the signal wire for a short to 5 V or battery
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
JCB P3424SCR partially blocked (overloaded)
SCR partially blocked (overloaded). The controller sees the SCR partially blocked behaving outside what it expects, so it logs a range, plausibility or performance fault.· Erratic or implausibleErratic or implausibleCheck soonCauses
- SCR partially blocked drifting or worn so it no longer matches the real condition
- Poor connection or high resistance in the SCR partially blocked circuit
- A related fault elsewhere making this reading look wrong
Checks
- 1Compare the SCR partially blocked value on live data with a known good value or a reference gauge
- 2Check the SCR partially blocked connector and wiring for high resistance and intermittent contact
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
JCB P3425SCR fully blocked (plugged)
SCR fully blocked (plugged). The controller sees the SCR fully blocked behaving outside what it expects, so it logs a range, plausibility or performance fault.· Erratic or implausibleErratic or implausibleCheck soonCauses
- SCR fully blocked drifting or worn so it no longer matches the real condition
- Poor connection or high resistance in the SCR fully blocked circuit
- A related fault elsewhere making this reading look wrong
Checks
- 1Compare the SCR fully blocked value on live data with a known good value or a reference gauge
- 2Check the SCR fully blocked connector and wiring for high resistance and intermittent contact
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Shared checks
Checks, in order
- 1Check the DEF with a refractometer (on the DEF quality sensor, with the diagnostic tool and a multimeter)
- 2Check for dosing and DEF faults (on the SCR catalyst, with the diagnostic tool and a multimeter)
- 3Drain and refill with correct DEF if it is wrong
- 4Check both NOx sensors for faults and plausible readings
- 5Check the DEF quality sensor wiring for opens, shorts and corroded connector pins
- 6Inspect the SCR catalyst for blockage, damage and contamination
- 7Check the DEF temperature against the expected range
Causes
- Wrong or diluted DEF in the tank
- SCR catalyst contaminated or blocked
- Quality sensor failed
- Dosing or DEF fault
Most common here: real condition (6 of 19)
Check the real value with a separate gauge or thermometer before blaming the sensor.
When to stop
You'll notice: A DEF quality warning shows and power may be reduced.
Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
- Partao JCB fault code list, page 11 (code table)
- Partao JCB fault code list, page 10 (code table)
- Partao JCB fault code list, page 15 (code table)
- Partao JCB fault code list, page 16 (code table)
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.