Deutz Collective faults and power reduction (Main and Secondary ECU) fault codes

On a twin-controller engine an SCR, DEF or hardware fault on one controller is reported to the other as a collective fault, and after it has stayed open the inducement logic cuts power in steps. The codes name which controller raised the collective fault and which error triggered it (DEF tank, SCR, dosing, reverting valve), and the power reduction steps and announcements (SPN 524190, 524191, 524230 to 524232, 524267).

More about these parts

They are consequences of another fault, not first causes.

FaultCheckSPN 524190FMI 14Deutz · Engine - Power reduction step 1
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Read the active and stored faults with Deutz SerDia (or the machine maker's diagnostic tool) on the engine diagnostic plug.

What do these codes mean?

Deutz codes SPN 524190 FMI 14 to SPN 524267 FMI 14 are all about the collective faults and power reduction (Main and Secondary ECU). None needs an immediate stop. Start with this check: open the fault list of the other controller first, because every code here follows from an entry there.

How urgent are they?

None of the 26 codes here means stop now; 25 can wait until the shift ends, but find the cause before the next one; 1 is information only.

  • Check soon25
  • Info1

What should I check first?

Open the fault list of the other controller first, because every code here follows from an entry there

Shared checks

26 of 26

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Engine - Power reduction step 11 code

    • Deutz SPN 524190 FMI 14Engine - Power reduction step 1: Special instructions

      The EMR4 flags engine power reduction step 1 as special instructions.· Other
      Check soon

      Causes

      • An active aftertreatment or emission fault
      • A protection fault such as a temperature limit
      • DEF quality or level warning

      Checks

      1. 1Read all active codes in SerDia; this entry accompanies a root-cause fault, so find that first
      2. 2Fix the root-cause fault and clear the codes, since the derate lifts when the cause is gone
      3. 3Check the DEF level and quality if SCR faults are active
      4. 4Check the aftertreatment sensors for plausibility before replacing parts
      5. 5Read which fault started the countdown and repair that fault before the second step is reached.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Engine - Power reduction step 21 code

    • Deutz SPN 524191 FMI 14Engine - Power reduction step 2: Special instructions

      The EMR4 flags engine power reduction step 2 as special instructions.· Lost message
      Check soon

      Causes

      • An unresolved emission or protection fault
      • DEF empty or poor quality
      • Persistent aftertreatment failure

      Checks

      1. 1Read all active codes in SerDia and find the original fault that led to this deeper derate
      2. 2Check the DEF level and quality with a refractometer, since empty or poor DEF often causes this step
      3. 3Check the aftertreatment sensors (NOx, temperature, pressure) for plausibility
      4. 4Fix the root cause, then clear the codes and confirm full power returns
      5. 5Repair the fault that started the reduction, then confirm in SerDia that the step counter falls back.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Exhaust aftertreatment - Secondary collective error triggered by DEF tank error Main ECU1 code

    • Deutz SPN 524201 FMI 11Exhaust aftertreatment - Secondary collective error triggered by DEF tank error Main ECU: Root cause not known

      The Secondary and Main controllers exchange status, and the EMR4 logged an event for the secondary collective error triggered by DEF tank error Main ECU (on engines with a Main and a Secondary ECU, raised after a Main ECU SCR or DEF error) with a cause it could not name.· Other
      Check soon

      Causes

      • The original fault is stored on the other controller
      • Interrupted CAN link or supply between the two controllers

      Checks

      1. 1Read the stored faults of the other controller and start with the oldest
      2. 2Fix that fault, then clear both controllers and test run the engine
      3. 3Read the DEF tank level, temperature and quality faults on the Main ECU.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Exhaust aftertreatment - Collective fault on Secondary ECU triggered by SCR failure Main5 codes

    • Deutz SPN 524202 FMI 11Exhaust aftertreatment - Collective fault on Secondary ECU triggered by SCR failure Main: Root cause not known

      The Secondary and Main controllers exchange status, and the EMR4 logged an event for the collective fault on Secondary ECU triggered by SCR failure Main (on engines with a Main and a Secondary ECU, raised after a Main ECU SCR or DEF error) with a cause it could not name.· Other
      Check soon

      Causes

      • The original fault is stored on the other controller
      • Interrupted CAN link or supply between the two controllers

      Checks

      1. 1Read the stored faults of the other controller and start with the oldest
      2. 2Fix that fault, then clear both controllers and test run the engine
      3. 3Read the SCR, dosing and NOx faults stored on the Main ECU.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • Deutz SPN 524204 FMI 11Exhaust aftertreatment - Collective fault on Secondary ECU triggered by SCR failure Main: Root cause not known

      Same fault as SPN 524202 FMI 11 for the Collective fault on Secondary ECU triggered by SCR failure Main message.· Other
      Check soon

      Causes

      • The original fault is stored on the other controller
      • Interrupted CAN link or supply between the two controllers

      Checks

      1. 1Read the SCR, dosing and NOx faults stored on the Main ECU.
      2. 2Read the stored faults of the other controller and start with the oldest
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • Deutz SPN 524205 FMI 11Exhaust aftertreatment - Collective fault on Secondary ECU triggered by SCR failure Main: Root cause not known

      Same fault as SPN 524202 FMI 11 for the Collective fault on Secondary ECU triggered by SCR failure Main message.· Other
      Check soon

      Causes

      • The original fault is stored on the other controller
      • Interrupted CAN link or supply between the two controllers

      Checks

      1. 1Read the SCR, dosing and NOx faults stored on the Main ECU.
      2. 2Read the stored faults of the other controller and start with the oldest
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • Deutz SPN 524239 FMI 11Exhaust aftertreatment - Collective fault on Secondary ECU triggered by SCR failure Main: Root cause not known

      Same fault as SPN 524202 FMI 11 for the Collective fault on Secondary ECU triggered by SCR failure Main message.· Other
      Check soon

      Causes

      • The original fault is stored on the other controller
      • Interrupted CAN link or supply between the two controllers

      Checks

      1. 1Read the SCR, dosing and NOx faults stored on the Main ECU.
      2. 2Read the stored faults of the other controller and start with the oldest
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • Deutz SPN 524248 FMI 11Exhaust aftertreatment - Collective fault on Secondary ECU triggered by SCR failure Main: Root cause not known

      Same fault as SPN 524202 FMI 11 for the Collective fault on Secondary ECU triggered by SCR failure Main message.· Other
      Check soon

      Causes

      • The original fault is stored on the other controller
      • Interrupted CAN link or supply between the two controllers

      Checks

      1. 1Read the SCR, dosing and NOx faults stored on the Main ECU.
      2. 2Read the stored faults of the other controller and start with the oldest
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Exhaust aftertreatment - Collective fault on Secondary ECU triggered DEF tank failure Main1 code

    • Deutz SPN 524203 FMI 11Exhaust aftertreatment - Collective fault on Secondary ECU triggered DEF tank failure Main: Root cause not known

      The Secondary and Main controllers exchange status, and the EMR4 logged an event for the collective fault on Secondary ECU triggered DEF tank failure Main (on engines with a Main and a Secondary ECU, raised after a Main ECU SCR or DEF error) with a cause it could not name.· Other
      Check soon

      Causes

      • The original fault is stored on the other controller
      • Interrupted CAN link or supply between the two controllers

      Checks

      1. 1Read the stored faults of the other controller and start with the oldest
      2. 2Fix that fault, then clear both controllers and test run the engine
      3. 3Check the DEF tank unit, heater and level faults on the Main ECU.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Exhaust aftertreatment - Collective fault on Secondary ECU triggered by DEF dosing failure Main1 code

    • Deutz SPN 524206 FMI 11Exhaust aftertreatment - Collective fault on Secondary ECU triggered by DEF dosing failure Main: Root cause not known

      The Secondary and Main controllers exchange status, and the EMR4 logged an event for the collective fault on Secondary ECU triggered by DEF dosing failure Main (on engines with a Main and a Secondary ECU, raised after a Main ECU SCR or DEF error) with a cause it could not name.· Other
      Check soon

      Causes

      • The original fault is stored on the other controller
      • Interrupted CAN link or supply between the two controllers

      Checks

      1. 1Read the stored faults of the other controller and start with the oldest
      2. 2Fix that fault, then clear both controllers and test run the engine
      3. 3Read the DEF metering unit and pump faults on the Main ECU.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Exhaust aftertreatment - Hardware failure on Secondary ECU activates power reduction1 code

    • Deutz SPN 524230 FMI 11Exhaust aftertreatment - Hardware failure on Secondary ECU activates power reduction: Root cause not known

      The Secondary and Main controllers exchange status, and the EMR4 logged an event for the hardware failure on Secondary ECU activates power reduction (on engines with a Main and a Secondary ECU) with a cause it could not name.· Other
      Check soon

      Causes

      • The original fault is stored on the other controller
      • Interrupted CAN link or supply between the two controllers

      Checks

      1. 1Read the stored faults of the other controller and start with the oldest
      2. 2Fix that fault, then clear both controllers and test run the engine
      3. 3Check supply, ground and connectors of the Secondary ECU first, then have the controller tested.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Exhaust aftertreatment - SCR failure on Secondary ECU activates power reduction2 codes

    • Deutz SPN 524231 FMI 11Exhaust aftertreatment - SCR failure on Secondary ECU activates power reduction: Root cause not known

      The Secondary and Main controllers exchange status, and the EMR4 logged an event for the SCR failure on Secondary ECU activates power reduction (on engines with a Main and a Secondary ECU) with a cause it could not name.· Other
      Check soon

      Causes

      • The original fault is stored on the other controller
      • Interrupted CAN link or supply between the two controllers

      Checks

      1. 1Read the stored faults of the other controller and start with the oldest
      2. 2Fix that fault, then clear both controllers and test run the engine
      3. 3Read the SCR faults stored on the Secondary ECU.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • Deutz SPN 524232 FMI 11Exhaust aftertreatment - SCR failure on Secondary ECU activates power reduction: Root cause not known

      Same fault as SPN 524231 FMI 11 for the SCR failure on Secondary ECU activates power reduction message.· Other
      Check soon

      Causes

      • The original fault is stored on the other controller
      • Interrupted CAN link or supply between the two controllers

      Checks

      1. 1Read the SCR faults stored on the Secondary ECU.
      2. 2Read the stored faults of the other controller and start with the oldest
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Exhaust aftertreatment - Collective fault on Main ECU triggered by SCR failure Secondary5 codes

    • Deutz SPN 524249 FMI 11Exhaust aftertreatment - Collective fault on Main ECU triggered by SCR failure Secondary: Root cause not known

      The Secondary and Main controllers exchange status, and the EMR4 logged an event for the collective fault on Main ECU triggered by SCR failure Secondary (on engines with a Main and a Secondary ECU, raised after a Secondary ECU SCR or DEF error) with a cause it could not name.· Other
      Check soon

      Causes

      • The original fault is stored on the other controller
      • Interrupted CAN link or supply between the two controllers

      Checks

      1. 1Read the stored faults of the other controller and start with the oldest
      2. 2Fix that fault, then clear both controllers and test run the engine
      3. 3Read the SCR and NOx faults stored on the Secondary ECU.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • Deutz SPN 524251 FMI 11Exhaust aftertreatment - Collective fault on Main ECU triggered by SCR failure Secondary: Root cause not known

      Same fault as SPN 524249 FMI 11 for the Collective fault on Main ECU triggered by SCR failure Secondary message.· Other
      Check soon

      Causes

      • The original fault is stored on the other controller
      • Interrupted CAN link or supply between the two controllers

      Checks

      1. 1Read the SCR and NOx faults stored on the Secondary ECU.
      2. 2Read the stored faults of the other controller and start with the oldest
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • Deutz SPN 524254 FMI 11Exhaust aftertreatment - Collective fault on Main ECU triggered by SCR failure Secondary: Root cause not known

      Same fault as SPN 524249 FMI 11 for the Collective fault on Main ECU triggered by SCR failure Secondary message.· Other
      Check soon

      Causes

      • The original fault is stored on the other controller
      • Interrupted CAN link or supply between the two controllers

      Checks

      1. 1Read the SCR and NOx faults stored on the Secondary ECU.
      2. 2Read the stored faults of the other controller and start with the oldest
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • Deutz SPN 524257 FMI 11Exhaust aftertreatment - Collective fault on Main ECU triggered by SCR failure Secondary: Root cause not known

      Same fault as SPN 524249 FMI 11 for the Collective fault on Main ECU triggered by SCR failure Secondary message.· Other
      Check soon

      Causes

      • The original fault is stored on the other controller
      • Interrupted CAN link or supply between the two controllers

      Checks

      1. 1Read the SCR and NOx faults stored on the Secondary ECU.
      2. 2Read the stored faults of the other controller and start with the oldest
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • Deutz SPN 524258 FMI 11Exhaust aftertreatment - Collective fault on Main ECU triggered by SCR failure Secondary: Root cause not known

      Same fault as SPN 524249 FMI 11 for the Collective fault on Main ECU triggered by SCR failure Secondary message.· Other
      Check soon

      Causes

      • The original fault is stored on the other controller
      • Interrupted CAN link or supply between the two controllers

      Checks

      1. 1Read the SCR and NOx faults stored on the Secondary ECU.
      2. 2Read the stored faults of the other controller and start with the oldest
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Exhaust aftertreatment - Reverting valve failure on Secondary ECU triggered by collective fault Main1 code

    • Deutz SPN 524252 FMI 11Exhaust aftertreatment - Reverting valve failure on Secondary ECU triggered by collective fault Main: Root cause not known

      The Secondary and Main controllers exchange status, and the EMR4 logged an event for the reverting valve failure on Secondary ECU triggered by collective fault Main (on engines with a Main and a Secondary ECU, raised after a Main ECU SCR or DEF error) with a cause it could not name.· Other
      Check soon

      Causes

      • The original fault is stored on the other controller
      • Interrupted CAN link or supply between the two controllers

      Checks

      1. 1Read the stored faults of the other controller and start with the oldest
      2. 2Fix that fault, then clear both controllers and test run the engine
      3. 3Check the reverting valve and its circuit on the Secondary side.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Exhaust aftertreatment - Collective fault on Main ECU triggered by DEF failure Secondary6 codes

    • Deutz SPN 524253 FMI 11Exhaust aftertreatment - Collective fault on Main ECU triggered by DEF failure Secondary: Root cause not known

      The Secondary and Main controllers exchange status, and the EMR4 logged an event for the collective fault on Main ECU triggered by DEF failure Secondary (on engines with a Main and a Secondary ECU, raised after a Secondary ECU SCR or DEF error) with a cause it could not name.· Other
      Check soon

      Causes

      • The original fault is stored on the other controller
      • Interrupted CAN link or supply between the two controllers

      Checks

      1. 1Read the stored faults of the other controller and start with the oldest
      2. 2Fix that fault, then clear both controllers and test run the engine
      3. 3Read the DEF pump, heater and tank faults stored on the Secondary ECU.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • Deutz SPN 524255 FMI 11Exhaust aftertreatment - Collective fault on Main ECU triggered by DEF failure Secondary: Root cause not known

      Same fault as SPN 524253 FMI 11 for the Collective fault on Main ECU triggered by DEF failure Secondary message.· Other
      Check soon

      Causes

      • The original fault is stored on the other controller
      • Interrupted CAN link or supply between the two controllers

      Checks

      1. 1Read the DEF pump, heater and tank faults stored on the Secondary ECU.
      2. 2Read the stored faults of the other controller and start with the oldest
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • Deutz SPN 524256 FMI 11Exhaust aftertreatment - Collective fault on Main ECU triggered by DEF failure Secondary: Root cause not known

      Same fault as SPN 524253 FMI 11 for the Collective fault on Main ECU triggered by DEF failure Secondary message.· Other
      Check soon

      Causes

      • The original fault is stored on the other controller
      • Interrupted CAN link or supply between the two controllers

      Checks

      1. 1Read the DEF pump, heater and tank faults stored on the Secondary ECU.
      2. 2Read the stored faults of the other controller and start with the oldest
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • Deutz SPN 524259 FMI 11Exhaust aftertreatment - Collective fault on Main ECU triggered by DEF failure Secondary: Root cause not known

      Same fault as SPN 524253 FMI 11 for the Collective fault on Main ECU triggered by DEF failure Secondary message.· Other
      Check soon

      Causes

      • The original fault is stored on the other controller
      • Interrupted CAN link or supply between the two controllers

      Checks

      1. 1Read the DEF pump, heater and tank faults stored on the Secondary ECU.
      2. 2Read the stored faults of the other controller and start with the oldest
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • Deutz SPN 524260 FMI 11Exhaust aftertreatment - Collective fault on Main ECU triggered by DEF failure Secondary: Root cause not known

      Same fault as SPN 524253 FMI 11 for the Collective fault on Main ECU triggered by DEF failure Secondary message.· Other
      Check soon

      Causes

      • The original fault is stored on the other controller
      • Interrupted CAN link or supply between the two controllers

      Checks

      1. 1Read the DEF pump, heater and tank faults stored on the Secondary ECU.
      2. 2Read the stored faults of the other controller and start with the oldest
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • Deutz SPN 524261 FMI 11Exhaust aftertreatment - Collective fault on Main ECU triggered by DEF failure Secondary: Root cause not known

      Same fault as SPN 524253 FMI 11 for the Collective fault on Main ECU triggered by DEF failure Secondary message.· Other
      Check soon

      Causes

      • The original fault is stored on the other controller
      • Interrupted CAN link or supply between the two controllers

      Checks

      1. 1Read the DEF pump, heater and tank faults stored on the Secondary ECU.
      2. 2Read the stored faults of the other controller and start with the oldest
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Exhaust aftertreatment - Announcement trigger power reduction step 21 code

    • Deutz SPN 524267 FMI 14Exhaust aftertreatment - Announcement trigger power reduction step 2: Special instructions

      The EMR4 flags the announcement trigger power reduction step 2 (in the EMR4 inducement logic) as a special instruction case.· Other
      Info

      Causes

      • A running condition that the EMR4 monitors has been reached
      • An earlier fault left a stored special instruction

      Checks

      1. 1Read the full SerDia list and the freeze frame data
      2. 2Check the machine service manual for the instruction that belongs to this condition
      3. 3Use the time of the announcement to clear the underlying DEF or SCR fault before power drops.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

Shared checks

Checks, in order

  1. 1Open the fault list of the other controller first, because every code here follows from an entry there
  2. 2Repair the DEF tank, SCR or dosing fault you find, then clear both controllers
  3. 3If the entry returns with nothing on the other controller, check the link between them
  4. 4Check the power reduction counter in SerDia, then run the engine under load and confirm full power returns

Causes

  • An SCR, DEF tank, dosing or reverting valve fault stored on the other controller and passed on
  • CAN link interrupted, so the entry never cleared
  • One controller cleared without the other, leaving a stale collective entry
  • A warning ignored long enough to escalate to power reduction

When to stop

You'll notice: A warning lamp and, if the fault stays, reduced engine power until the original fault on the other controller is repaired.

Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.