Deutz · Throttle and operator inputs

Deutz Fault Code SPN 91 FMI 3

Machine - Position accelerator pedal (sensor 1) - Voltage above normal or shorted to high source

What does Deutz code SPN 91 FMI 3 mean?

The EMR4 reads the accelerator pedal (sensor 1) (in the operator pedal or hand throttle assembly) above its valid voltage range. Urgency: check soon - the machine may derate or limit a function. Check first: sweep the pedal slowly through its whole travel with SerDia open and watch for dropouts or steps in the percentage.

FaultCheckSPN 91FMI 3Deutz · Throttle and operator inputs
FMI 3
Voltage above normal or shorted high

Can I keep running with it?

Check soon

The machine may derate or limit a function. Find the cause before the next shift.

What should I check first?

Sweep the pedal slowly through its whole travel with SerDia open and watch for dropouts or steps in the percentage

Then 3 more checks
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Read the active and stored faults with Deutz SerDia (or the machine maker's diagnostic tool) on the engine diagnostic plug.

Checks

0 of 4 done

Causes

  • Pedal connector contaminated by washdown water
  • Signal wire shorted to the 5 V or battery supply
  • Open ground wire to the pedal potentiometer

How it failed

You'll notice: The engine may sit at idle or run on a limited throttle.

Shorted highRead from FMI 3: voltage above normal or shorted high

The signal sits at or near the supply voltage - more than a working sensor can send.

ControllerPartSupplySignalGround
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.
Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good result
Open circuit (OL) between them. Any low reading is the short.

When to stop

Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.

Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Same part, other failures: Operator inputs, warning lamps, shutdown requests and telemetry

3 other codes on this part are also shorted high (SPN 29 FMI 3, SPN 624 FMI 3, SPN 524087 FMI 3). When they show together, start at the wiring and connector they share.

Show the other 13 codes
All 22 Operator inputs, warning lamps, shutdown requests and telemetry codes on one page

Source

DEUTZ KWP-Codes EMR4 (KWPList EMR4 DE EN, Revision 2.0), page 18

This source lists SPN 91 FMI 3 and its meaning. The guidance on this page is general, not taken from it.

The source covers: Deutz engines with the EMR4 controller (the Deutz list applies to all EMR4 engine series, e.g. TCD 2.9, 3.6, 4.1, 6.1, 7.8 as fitted in machines).

Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.