Deutz Fault Code SPN 523350 FMI 4
Engine - Injectors bank 1 - Voltage below normal or shorted to low source
What does Deutz code SPN 523350 FMI 4 mean?
The EMR4 sees injector bank 1 at a voltage below normal, as if the common bank wire is shorted to ground. The banks supply a group of injectors, so more than one cylinder may be affected. Urgency: stop now - shut down and fix before working on. Check first: unplug the injectors of bank 1 one at a time with the key on to see which one clears the code.
- SPN 523350
- What is at fault
- FMI 4
- Voltage below normal or shorted low
Can I keep running with it?
Stop now
Shut down and fix before working on. Running on risks damage or the machine locks out.
What should I check first?
Unplug the injectors of bank 1 one at a time with the key on to see which one clears the code
Then 5 more checksWhere to read it
Read the active and stored faults with Deutz SerDia (or the machine maker's diagnostic tool) on the engine diagnostic plug.
Checks
0 of 6 done
Causes
- Common bank wire for injector bank 1 shorted to ground
- An injector in bank 1 shorted to its body
- Through-connector under the valve cover wet or burnt
- Injector bank driver in the EMR4 failing
1 more causeFewer causes
- Wire pinched against the engine block or frame so the signal is pulled to ground
How it failed
You'll notice: A group of cylinders can cut out together, giving heavy shaking, loss of power or stalling.
Shorted lowRead from FMI 4: voltage below normal or shorted low
The signal sits at or near zero volts - less than a working sensor can send.
- Meter test
- Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
- Good result
- Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
When to stop
Common-rail fuel runs at very high pressure. Never open a high-pressure line or fitting with the engine running or just after it stops - a fine fuel jet can pierce skin.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Same part, other failures: Injector solenoid circuits and banks
5 other codes on this part are also shorted low (SPN 2797 FMI 4, SPN 2798 FMI 4, SPN 523352 FMI 4, SPN 523997 FMI 4 and more). When they show together, start at the wiring and connector they share.
- SPN 656 FMI 3Engine - Injector 6 - Voltage above normal or shorted to high sourceShorted highCheck soon
- SPN 656 FMI 5Engine - Injector 6 - Current below normal or open circuitOpen circuitStop now
- SPN 2797 FMI 4Engine - Injector group - Voltage below normal or shorted to low sourceShorted lowCheck soon
- SPN 2798 FMI 4Engine - Injector group 2 - Voltage below normal or shorted to low sourceShorted lowCheck soon
- SPN 523350 FMI 4Engine - Injectors bank 1 - Voltage below normal or shorted to low sourceShorted lowStop now
- SPN 523352 FMI 4Engine - Injectors bank 2 - Voltage below normal or shorted to low sourceShorted lowCheck soon
- SPN 523997 FMI 4Engine - Injectors bank 1 Secondary - Voltage below normal or shorted to low sourceShorted lowCheck soon
- SPN 523998 FMI 4Engine - Injectors bank 2 Secondary - Voltage below normal or shorted to low sourceShorted lowCheck soon
- SPN 524000 FMI 3Engine - Injector 7 - Voltage above normal or shorted to high sourceShorted highCheck soon
Show the other 13 codesHide the other codes
- SPN 651 FMI 3Engine - Injector 1 - Voltage above normal or shorted to high sourceShorted highStop now
- SPN 651 FMI 5Engine - Injector 1 - Current below normal or open circuitOpen circuitStop now
- SPN 652 FMI 3Engine - Injector 2 - Voltage above normal or shorted to high sourceShorted highStop now
- SPN 652 FMI 5Engine - Injector 2 - Current below normal or open circuitOpen circuitStop now
- SPN 653 FMI 3Engine - Injector 3 - Voltage above normal or shorted to high sourceShorted highStop now
- SPN 653 FMI 5Engine - Injector 3 - Current below normal or open circuitOpen circuitStop now
- SPN 654 FMI 3Engine - Injector 4 - Voltage above normal or shorted to high sourceShorted highStop now
- SPN 654 FMI 5Engine - Injector 4 - Current below normal or open circuitOpen circuitStop now
- SPN 655 FMI 3Engine - Injector 5 - Voltage above normal or shorted to high sourceShorted highCheck soon
- SPN 655 FMI 5Engine - Injector 5 - Current below normal or open circuitOpen circuitStop now
- SPN 524000 FMI 5Engine - Injector 7 - Current below normal or open circuitOpen circuitCheck soon
- SPN 524001 FMI 3Engine - Injector 8 - Voltage above normal or shorted to high sourceShorted highCheck soon
- SPN 524001 FMI 5Engine - Injector 8 - Current below normal or open circuitOpen circuitCheck soon
Other Deutz codes: Injectors and combustion
Related on Equipments Finder
Source
DEUTZ KWP-Codes EMR4 (KWPList EMR4 DE EN, Revision 2.0), page 10
This source lists SPN 523350 FMI 4 and its meaning. The guidance on this page is general, not taken from it.
The source covers: Deutz engines with the EMR4 controller (the Deutz list applies to all EMR4 engine series, e.g. TCD 2.9, 3.6, 4.1, 6.1, 7.8 as fitted in machines).
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.