The monitoring side of combustion. The injector power stage and its control (the EMR4 driver circuit), the misfire detection that finds a cylinder not firing, and the crankshaft and camshaft speed sensors (SPN 190) the EMR4 needs to time every injection.

More about these parts

Each code names the function and what the controller saw.

FaultStopSPN 190FMI 0Deutz · Rotation speed
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Read the active and stored faults with Deutz SerDia (or the machine maker's diagnostic tool) on the engine diagnostic plug.

What do these codes mean?

Deutz codes SPN 190 FMI 0 to SPN 524036 FMI 12 are all about the injector power stage, misfire detection and engine speed. Most are part or controller faults; 2 need an immediate stop. Start with this check: read crankshaft and camshaft speed in SerDia while cranking and check both sensors appear.

How urgent are they?

2 of 18 codes here mean stop now; the other 16 can wait until the shift ends, but find the cause before the next one.

  • Stop now2
  • Check soon16

What should I check first?

Read crankshaft and camshaft speed in SerDia while cranking and check both sensors appear

Shared checks

18 of 18

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Rotation speed6 codes

    • Deutz SPN 190 FMI 0Rotation speed: Reading too high· most severe

      The EMR4 sees engine speed above its allowed range.· Real condition
      Stop now

      Causes

      • Machine overrunning the engine, for example going downhill in gear
      • Stuck throttle input or wrong speed request over CAN
      • Speed sensor signal faulty giving a false high value
      • Turbo oil leak feeding the engine with oil (runaway)

      Checks

      1. 1Check how the machine was operating at the time; downhill overrun is the most common real overspeed
      2. 2Check the throttle signal and any CAN speed request in SerDia
      3. 3Check the crankshaft and camshaft sensor signals for noise
      4. 4Look for oil in the charge air pipe, which can cause a diesel runaway
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Engine - Rotation speed - Data above normal operational range (Most severe level)

      Full page for SPN 190 FMI 0
    • Deutz SPN 190 FMI 2Rotation speed: Erratic reading

      The EMR4 sees the engine speed signal erratic or inconsistent between the crankshaft and camshaft sensors.· Erratic or implausible
      Check soon

      Causes

      • Sensor air gap changed or sensor loose
      • Sensor connector damaged or wet
      • Trigger wheel damaged or dirty with metal swarf
      • Harness chafed next to the starter or exhaust

      Checks

      1. 1Check both the crankshaft and camshaft speed sensors for tightness and a clean tip
      2. 2Inspect the trigger wheel through the sensor hole for damage or metal debris
      3. 3Wiggle the sensor harness while the engine idles and watch for speed dropouts in SerDia
      4. 4Check the sensor connectors for moisture and corrosion, which cause erratic signals at the flywheel end
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Engine - Rotation speed - Data erratic intermittent or incorrect

    • Deutz SPN 190 FMI 8Rotation speed: Abnormal frequency / pulse width

      The EMR4 sees the engine speed signal with abnormal frequency or pulse width.· Erratic or implausible
      Check soon

      Causes

      • Camshaft and crankshaft sensors out of sync after timing gear work
      • Trigger wheel with a damaged tooth
      • Electrical interference on the sensor cable
      • Sensor air gap out of limits

      Checks

      1. 1Compare crankshaft and camshaft sensor signals in SerDia and see whether one drops out
      2. 2Check the trigger wheels for a damaged or missing tooth, especially after timing gear work
      3. 3Check that the sensor cables are routed away from heavy power cables that can induce noise
      4. 4Check the sensor mounting and air gap against the engine manual
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Engine - Rotation speed - Abnormal frequency or pulse width or period

    • Deutz SPN 190 FMI 11Rotation speed: Root cause not known

      The EMR4 logged an engine speed fault of unknown cause.· Other
      Check soon

      Causes

      • One of the speed sensors failing
      • Poor sensor connector contact
      • Damaged harness
      • Timing problem after engine work

      Checks

      1. 1Read the full list in SerDia and check which sensor channel, crankshaft or camshaft, reports the fault
      2. 2Inspect both sensor connectors for corrosion and loose pins
      3. 3Check the sensor air gap and make sure the sensors are fully seated
      4. 4Check the timing gear marks if the engine was recently repaired
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • Deutz SPN 190 FMI 12Rotation speed: Bad device or component

      The EMR4 judges a speed sensor to be a bad device.· Part or controller
      Check soon

      Causes

      • Sensor failed internally from heat or oil
      • Sensor cable broken
      • Connector corroded
      • Wrong sensor fitted after repair

      Checks

      1. 1Identify in SerDia which sensor, crankshaft or camshaft, is reported as the bad device
      2. 2Measure the sensor coil resistance if it is an inductive type and compare with the engine manual
      3. 3Replace the failed sensor with the correct part number and check the air gap
      4. 4Check the connector and cable for damage before you condemn the sensor
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Engine - Rotation speed - Bad intelligent device or component

    • Deutz SPN 190 FMI 14Rotation speed: Special instructions

      The EMR4 flags an engine speed condition as special instructions.· Real condition
      Check soon

      Causes

      • A past overspeed event logged for service
      • Machine operating beyond rated engine speed
      • Speed request from the machine controller too high

      Checks

      1. 1Read the freeze frame in SerDia for the engine speed and load at the time of the event
      2. 2Review how the machine was being operated, since a downhill overrun commonly logs this entry
      3. 3Check the CAN speed request from the machine controller for out-of-range values
      4. 4Check the oil level and the charge air pipe for oil carry-over after any overspeed
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Misfire for multiple cylinders1 code

    • Deutz SPN 1322 FMI 12Misfire for multiple cylinders: Bad device or component

      The EMR4 judges a misfire on several cylinders.· Part or controller
      Check soon

      Causes

      • Contaminated or watery fuel affecting every cylinder
      • Fuel supply restriction starving the high-pressure pump
      • Rail pressure too low or unstable
      • Common injector bank wiring fault

      Checks

      1. 1Check the fuel filters and drain the water separator, since contaminated fuel hits every cylinder
      2. 2Read rail pressure actual versus target in SerDia under load
      3. 3Check for an injector bank wiring code at the same time
      4. 4Check the fuel quality in a clear container for water and sediment
      5. 5Check the speed sensors for a noisy signal that confuses the misfire detection
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Engine - Misfire for multiple cylinders - Bad intelligent device or component

  • Misfire cylinder 11 code

    • Deutz SPN 1323 FMI 12Misfire cylinder 1: Bad device or component

      The EMR4 judges a misfire on cylinder 1.· Part or controller
      Check soon

      Causes

      • Injector 1 blocked, leaking or open
      • Low compression on cylinder 1
      • Air or water in the fuel
      • Injector cable damaged

      Checks

      1. 1Run a cylinder cut-out or balance test in SerDia and see how cylinder 1 compares
      2. 2Measure injector 1 coil resistance and check its cable
      3. 3Check the injector return flow for a leaking injector
      4. 4Do a compression test if electrical checks are clean
      5. 5Check fuel quality for water or contamination
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Engine - Misfire cylinder 1 - Bad intelligent device or component

  • Misfire cylinder 21 code

    • Deutz SPN 1324 FMI 12Misfire cylinder 2: Bad device or component

      The EMR4 judges the misfire cylinder 2 (in the EMR4, based on the crankshaft speed signal) to be a bad device.· Part or controller
      Check soon

      Causes

      • Internal failure of the part or its electronics
      • Water, soot or dirt inside the part

      Checks

      1. 1Read the misfire cylinder 2 status in SerDia and run any available actuator or component test
      2. 2Check supply voltage and ground at the connector with the key on to confirm it is powered
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Engine - Misfire cylinder 2 - Bad intelligent device or component

  • Misfire cylinder 31 code

    • Deutz SPN 1325 FMI 12Misfire cylinder 3: Bad device or component

      The EMR4 judges the misfire cylinder 3 (in the EMR4, based on the crankshaft speed signal) to be a bad device.· Part or controller
      Check soon

      Causes

      • Internal failure of the part or its electronics
      • Water, soot or dirt inside the part

      Checks

      1. 1Read the misfire cylinder 3 status in SerDia and run any available actuator or component test
      2. 2Check supply voltage and ground at the connector with the key on to confirm it is powered
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Engine - Misfire cylinder 3 - Bad intelligent device or component

  • Misfire cylinder 41 code

    • Deutz SPN 1326 FMI 12Misfire cylinder 4: Bad device or component

      The EMR4 judges the misfire cylinder 4 (in the EMR4, based on the crankshaft speed signal) to be a bad device.· Part or controller
      Check soon

      Causes

      • Internal failure of the part or its electronics
      • Water, soot or dirt inside the part

      Checks

      1. 1Read the misfire cylinder 4 status in SerDia and run any available actuator or component test
      2. 2Check supply voltage and ground at the connector with the key on to confirm it is powered
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Engine - Misfire cylinder 4 - Bad intelligent device or component

  • Misfire cylinder 51 code

    • Deutz SPN 1327 FMI 12Misfire cylinder 5: Bad device or component

      The EMR4 judges the misfire cylinder 5 (in the EMR4, based on the crankshaft speed signal) to be a bad device.· Part or controller
      Check soon

      Causes

      • Internal failure of the part or its electronics
      • Water, soot or dirt inside the part

      Checks

      1. 1Read the misfire cylinder 5 status in SerDia and run any available actuator or component test
      2. 2Check supply voltage and ground at the connector with the key on to confirm it is powered
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Engine - Misfire cylinder 5 - Bad intelligent device or component

  • Misfire cylinder 61 code

    • Deutz SPN 1328 FMI 12Misfire cylinder 6: Bad device or component

      The EMR4 judges the misfire cylinder 6 (in the EMR4, based on the crankshaft speed signal) to be a bad device.· Part or controller
      Check soon

      Causes

      • Internal failure of the part or its electronics
      • Water, soot or dirt inside the part

      Checks

      1. 1Read the misfire cylinder 6 status in SerDia and run any available actuator or component test
      2. 2Check supply voltage and ground at the connector with the key on to confirm it is powered
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Engine - Misfire cylinder 6 - Bad intelligent device or component

  • Output power stage Injector1 code

    • Deutz SPN 523354 FMI 12Output power stage Injector: Bad device or component

      The EMR4 judges the injector output power stage to be a bad device.· Part or controller
      Stop now

      Causes

      • Failed injector power stage inside the EMR4
      • Shorted injector or bank wire overloading the stage
      • Supply voltage dips or spikes upsetting the driver
      • Water inside the ECU connector

      Checks

      1. 1Read all injector codes in SerDia; shorted-injector codes alongside this one point at wiring or an injector rather than the controller
      2. 2Check battery supply and ground to the EMR4 for voltage dips and spikes
      3. 3Check the ECU connector for water and corrosion
      4. 4Clear and recheck; if it returns with no injector faults, suspect the EMR4 itself
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Engine - Output power stage Injector - Bad intelligent device or component

  • Power stage diagnostic2 codes

    • Deutz SPN 523982 FMI 0Power stage diagnostic: Reading too high· most severe

      The EMR4 rates the power stage diagnostic (inside the EMR4, which switches the injector solenoids) as above its allowed operating range, at the most severe level.· Real condition
      Check soon

      Causes

      • The monitored condition is really above its limit, for example from overload or a blockage
      • Signal or part drifting high with age

      Checks

      1. 1Read the power stage diagnostic value in SerDia and compare it with an independent measurement before replacing parts
      2. 2Look for the real cause of an excessive value, such as a restriction or an overloaded function
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Engine - Power stage diagnostic - Data above normal operational range (Most severe level)

    • Deutz SPN 523982 FMI 1Power stage diagnostic: Reading too low· most severe

      The EMR4 rates the power stage diagnostic (inside the EMR4, which switches the injector solenoids) as below its allowed operating range, at the most severe level.· Real condition
      Check soon

      Causes

      • The monitored condition is really below its limit, for example a leak, a blockage or a part not working
      • Signal or part drifting low with age

      Checks

      1. 1Read the power stage diagnostic value in SerDia and compare it with an independent measurement before replacing parts
      2. 2Look for the real cause of a low value, such as a leak, a blocked line or a weak supply
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Engine - Power stage diagnostic - Data below normal operational range (Most severe level)

  • Injector control Secondary1 code

    • Deutz SPN 523999 FMI 12Injector control Secondary: Bad device or component

      The EMR4 judges the injector control Secondary (inside the EMR4, which switches the injector solenoids) to be a bad device.· Part or controller
      Check soon

      Causes

      • Internal failure of the part or its electronics
      • Water, soot or dirt inside the part

      Checks

      1. 1Read the injector control Secondary status in SerDia and run any available actuator or component test
      2. 2Check supply voltage and ground at the connector with the key on to confirm it is powered
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Engine - Injector control Secondary - Bad intelligent device or component

  • Diagnostic injector Secondary1 code

    • Deutz SPN 524036 FMI 12Diagnostic injector Secondary: Bad device or component

      The EMR4 judges the diagnostic injector Secondary (inside the EMR4, which switches the injector solenoids) to be a bad device.· Part or controller
      Check soon

      Causes

      • Internal failure of the part or its electronics
      • Water, soot or dirt inside the part

      Checks

      1. 1Read the diagnostic injector Secondary status in SerDia and run any available actuator or component test
      2. 2Check supply voltage and ground at the connector with the key on to confirm it is powered
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Engine - Diagnostic injector Secondary - Bad intelligent device or component

Shared checks

Checks, in order

  1. 1Read crankshaft and camshaft speed in SerDia while cranking and check both sensors appear
  2. 2Inspect the speed sensors for metal debris, damage and a firm mounting
  3. 3Check the injector the misfire code points at with a cylinder balance test
  4. 4Check the power stage supply and ground at the EMR4 connector

Causes

  • Crankshaft or camshaft speed sensor dirty, loose, or with a damaged tone wheel
  • Sensor gap or mounting wrong after engine work
  • Injector or injector wiring causing the misfire
  • Fault in the power stage supply or ground

Most codes here: part or controller (11 of 18)

Check power and ground at the module connector with the key on, then its fuses.

When to stop

You'll notice: A warning lamp or limited function.

Common-rail fuel runs at very high pressure. Never open a high-pressure line or fitting with the engine running or just after it stops - a fine fuel jet can pierce skin.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.