Deutz · Injectors and combustion
Deutz Fault Code SPN 651 FMI 5
Engine - Injector 1 - Current below normal or open circuit
What does Deutz code SPN 651 FMI 5 mean?
The EMR4 measures too little current through the injector for cylinder 1, so the circuit is open. That cylinder gets no injection pulse and the controller logs the fault against injector 1. Urgency: stop now - shut down and fix before working on. Check first: with the key off, measure the cylinder 1 injector solenoid resistance at the injector terminals; an open coil reads infinite.
- SPN 651
- Engine injector, cylinder 1
- FMI 5
- Current below normal or open circuit
Can I keep running with it?
Stop now
Shut down and fix before working on. Running on risks damage or the machine locks out.
What should I check first?
With the key off, measure the cylinder 1 injector solenoid resistance at the injector terminals; an open coil reads infinite
Then 5 more checksWhere to read it
Read the active and stored faults with Deutz SerDia (or the machine maker's diagnostic tool) on the engine diagnostic plug.
Checks
0 of 6 done
Causes
- A broken wire or a pushed-back pin between the EMR4 and the cylinder 1 injector solenoid
- Injector solenoid coil open inside the injector
- Injector connector under the valve cover not fully latched
- Valve cover through-connector corroded or damaged
1 more causeFewer causes
- Terminal pushed back or corroded in its connector so the circuit is open
How it failed
You'll notice: Engine runs on three cylinders or rough, with reduced power, vibration and a warning lamp; it may stall at idle.
Open circuitRead from FMI 5: current below normal or open circuit
No current flows, or the signal floats - a wire, pin or coil is broken.
- Meter test
- Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
- Good result
- Near 0 Ω on each wire. The part reads its listed resistance, not OL.
When to stop
Common-rail fuel runs at very high pressure. Never open a high-pressure line or fitting with the engine running or just after it stops - a fine fuel jet can pierce skin.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Same part, other failures: Injector solenoid circuits and banks
7 other codes on this part are also open circuit (SPN 652 FMI 5, SPN 653 FMI 5, SPN 654 FMI 5, SPN 655 FMI 5 and more). When they show together, start at the wiring and connector they share.
- SPN 651 FMI 3Engine - Injector 1 - Voltage above normal or shorted to high sourceShorted highStop now
- SPN 651 FMI 5Engine - Injector 1 - Current below normal or open circuitOpen circuitStop now
- SPN 652 FMI 3Engine - Injector 2 - Voltage above normal or shorted to high sourceShorted highStop now
- SPN 652 FMI 5Engine - Injector 2 - Current below normal or open circuitOpen circuitStop now
- SPN 653 FMI 3Engine - Injector 3 - Voltage above normal or shorted to high sourceShorted highStop now
- SPN 653 FMI 5Engine - Injector 3 - Current below normal or open circuitOpen circuitStop now
- SPN 654 FMI 3Engine - Injector 4 - Voltage above normal or shorted to high sourceShorted highStop now
- SPN 654 FMI 5Engine - Injector 4 - Current below normal or open circuitOpen circuitStop now
- SPN 655 FMI 3Engine - Injector 5 - Voltage above normal or shorted to high sourceShorted highCheck soon
Show the other 13 codesHide the other codes
- SPN 655 FMI 5Engine - Injector 5 - Current below normal or open circuitOpen circuitStop now
- SPN 656 FMI 3Engine - Injector 6 - Voltage above normal or shorted to high sourceShorted highCheck soon
- SPN 656 FMI 5Engine - Injector 6 - Current below normal or open circuitOpen circuitStop now
- SPN 2797 FMI 4Engine - Injector group - Voltage below normal or shorted to low sourceShorted lowCheck soon
- SPN 2798 FMI 4Engine - Injector group 2 - Voltage below normal or shorted to low sourceShorted lowCheck soon
- SPN 523350 FMI 4Engine - Injectors bank 1 - Voltage below normal or shorted to low sourceShorted lowStop now
- SPN 523352 FMI 4Engine - Injectors bank 2 - Voltage below normal or shorted to low sourceShorted lowCheck soon
- SPN 523997 FMI 4Engine - Injectors bank 1 Secondary - Voltage below normal or shorted to low sourceShorted lowCheck soon
- SPN 523998 FMI 4Engine - Injectors bank 2 Secondary - Voltage below normal or shorted to low sourceShorted lowCheck soon
- SPN 524000 FMI 3Engine - Injector 7 - Voltage above normal or shorted to high sourceShorted highCheck soon
- SPN 524000 FMI 5Engine - Injector 7 - Current below normal or open circuitOpen circuitCheck soon
- SPN 524001 FMI 3Engine - Injector 8 - Voltage above normal or shorted to high sourceShorted highCheck soon
- SPN 524001 FMI 5Engine - Injector 8 - Current below normal or open circuitOpen circuitCheck soon
Related on Equipments Finder
Source
DEUTZ KWP-Codes EMR4 (KWPList EMR4 DE EN, Revision 2.0), page 10
This source lists SPN 651 FMI 5 and its meaning. The guidance on this page is general, not taken from it.
The source covers: Deutz engines with the EMR4 controller (the Deutz list applies to all EMR4 engine series, e.g. TCD 2.9, 3.6, 4.1, 6.1, 7.8 as fitted in machines).
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.