EF Logo

Deutz · Exhaust aftertreatment (DPF/DOC)

Deutz Standstill regeneration and burner operation fault codes

The regeneration process itself: the standstill (parked) regeneration, the burner operation and its regeneration steps, and the burner firing chamber temperature. Each code names the step or condition that failed to complete.

FaultCheckSPN 3711FMI 12Deutz · Exhaust aftertreatment - Temperature during Standstill regeneration
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Read the active and stored faults with Deutz SerDia (or the machine maker's diagnostic tool) on the engine diagnostic plug.

What do these codes mean?

Deutz codes SPN 3711 FMI 12 to SPN 524195 FMI 14 are all about the standstill regeneration and burner operation. The most common failure type is erratic or implausible (5 of 19); none needs an immediate stop. Start with this check: read the regeneration status and the interlock conditions in SerDia.

How urgent are they?

None of the 19 codes here means stop now; 16 can wait until the shift ends, but find the cause before the next one; 3 are information only.

  • Check soon16
  • Info3

What should I check first?

Read the regeneration status and the interlock conditions in SerDia

Shared checks

19 of 19

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Exhaust aftertreatment - Temperature during Standstill regeneration1 code

    • Deutz SPN 3711 FMI 12Exhaust aftertreatment - Temperature during Standstill regeneration: Bad device or component

      The EMR4 judges the temperature during Standstill regeneration (a regeneration run while the machine is parked, started by the operator) to be a bad device.· Part or controller
      Check soon

      Causes

      • Internal failure of the part or its electronics
      • Water, soot or dirt inside the part

      Checks

      1. 1Read the temperature during Standstill regeneration status in SerDia and run any available actuator or component test
      2. 2Check supply voltage and ground at the connector with the key on to confirm it is powered
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Exhaust aftertreatment - Temperature during Standstill regeneration - Bad intelligent device or component

  • Exhaust aftertreatment - Time Standstill regeneration3 codes

    • Deutz SPN 3936 FMI 14Exhaust aftertreatment - Time Standstill regeneration: Special instructions

      The EMR4 flags the time Standstill regeneration (a regeneration run while the machine is parked, started by the operator) as a special instruction case.· Other
      Info

      Causes

      • A running condition that the EMR4 monitors has been reached
      • An earlier fault left a stored special instruction

      Checks

      1. 1Read the full SerDia list and the freeze frame data
      2. 2Check the machine service manual for the instruction that belongs to this condition
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • Deutz SPN 524193 FMI 8Exhaust aftertreatment - Time Standstill regeneration: Abnormal frequency / pulse width

      The EMR4 sees an abnormal frequency or pulse width on the time Standstill regeneration (a regeneration run while the machine is parked, started by the operator).· Erratic or implausible
      Check soon

      Causes

      • Electrical noise or a loose connection distorting the signal
      • Sensor or sending unit failing

      Checks

      1. 1Watch the time Standstill regeneration value in SerDia for jumps and dropouts
      2. 2Inspect the connector and harness for chafe, moisture and loose pins
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Exhaust aftertreatment - Time Standstill regeneration - Abnormal frequency or pulse width or period

    • Deutz SPN 524194 FMI 8Exhaust aftertreatment - Time Standstill regeneration: Abnormal frequency / pulse width

      The EMR4 sees an abnormal frequency or pulse width on the time Standstill regeneration (a regeneration run while the machine is parked, started by the operator).· Erratic or implausible
      Check soon

      Causes

      • Electrical noise or a loose connection distorting the signal
      • Sensor or sending unit failing

      Checks

      1. 1Watch the time Standstill regeneration value in SerDia for jumps and dropouts
      2. 2Inspect the connector and harness for chafe, moisture and loose pins
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Exhaust aftertreatment - Time Standstill regeneration - Abnormal frequency or pulse width or period

  • Exhaust aftertreatment - Burner operation2 codes

    • Deutz SPN 523619 FMI 0Exhaust aftertreatment - Burner operation: Reading too high· most severe

      The EMR4 rates the burner operation (the fuel burner in the exhaust that heats the filter for regeneration) as above its allowed operating range, at the most severe level.· Real condition
      Check soon

      Causes

      • The monitored condition is really above its limit, for example from overload or a blockage
      • Signal or part drifting high with age

      Checks

      1. 1Read the burner operation value in SerDia and compare it with an independent measurement before replacing parts
      2. 2Look for the real cause of an excessive value, such as a restriction or an overloaded function
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Exhaust aftertreatment - Burner operation - Data above normal operational range (Most severe level)

    • Deutz SPN 524013 FMI 7Exhaust aftertreatment - Burner operation: Not responding / out of adjustment

      The EMR4 sees the burner operation (the fuel burner in the exhaust that heats the filter for regeneration) not following its command.· Part or controller
      Check soon

      Causes

      • Part stuck or seized by dirt or deposits
      • Linkage or drive worn or disconnected

      Checks

      1. 1Command the burner operation from SerDia and compare actual with commanded position or value
      2. 2Move the part by hand with the key off to find out whether it is mechanically stuck
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Exhaust aftertreatment - Burner operation - Mechanical system not responding or out of adjustment

  • Exhaust aftertreatment - Burner regeneration lack of oxygen1 code

    • Deutz SPN 523619 FMI 1Exhaust aftertreatment - Burner regeneration lack of oxygen: Reading too low· most severe

      The EMR4 rates the burner regeneration lack of oxygen (the fuel burner in the exhaust that heats the filter for regeneration) as below its allowed operating range, at the most severe level.· Real condition
      Check soon

      Causes

      • The monitored condition is really below its limit, for example a leak, a blockage or a part not working
      • Signal or part drifting low with age

      Checks

      1. 1Read the burner regeneration lack of oxygen value in SerDia and compare it with an independent measurement before replacing parts
      2. 2Look for the real cause of a low value, such as a leak, a blocked line or a weak supply
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Exhaust aftertreatment - Burner regeneration lack of oxygen - Data below normal operational range (Most severe level)

  • Exhaust aftertreatment - Temperature upstream SCR Cat1 code

    • Deutz SPN 523619 FMI 2Exhaust aftertreatment - Temperature upstream SCR Cat: Erratic reading

      The EMR4 sees the temperature upstream SCR Cat (the fuel burner in the exhaust that heats the filter for regeneration) erratic, intermittent or implausible.· Erratic or implausible
      Check soon

      Causes

      • Intermittent contact in a connector or a pin with fretting
      • Harness chafed where it moves with vibration

      Checks

      1. 1Watch the temperature upstream SCR Cat value in SerDia while wiggling the harness and connector and note when it jumps
      2. 2Compare it with a related value, since a lone odd reading points at the circuit or part itself
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Exhaust aftertreatment - Temperature upstream SCR Cat - Data erratic intermittent or incorrect

  • Exhaust aftertreatment - Burner firing chamber temperature5 codes

    • Deutz SPN 523921 FMI 0Exhaust aftertreatment - Burner firing chamber temperature: Reading too high· most severe

      The burner firing chamber temperature sensor (in the burner firing chamber of the exhaust aftertreatment burner) reports a temperature above the allowed operating range.· Real condition
      Check soon

      Causes

      • Partial short or wet connector lowering the burner firing chamber temperature sensor resistance so it reads hot
      • Sensor drifting low in resistance with age

      Checks

      1. 1Check the real temperature with an infrared thermometer or mechanical gauge before touching the burner firing chamber temperature sensor
      2. 2Look in SerDia at the burner firing chamber temperature sensor reading next to a neighbouring temperature; a lone hot value points at the sensor
      3. 3Check the connector pins for moisture and corrosion, which can pull a reading hot
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Exhaust aftertreatment - Burner firing chamber temperature - Data above normal operational range (Most severe level)

    • Deutz SPN 523921 FMI 1Exhaust aftertreatment - Burner firing chamber temperature: Reading too low· most severe

      The burner firing chamber temperature sensor (in the burner firing chamber of the exhaust aftertreatment burner) reports a temperature below the allowed range.· Real condition
      Check soon

      Causes

      • High resistance in the burner firing chamber temperature sensor connector or a corroded pin making it read cold
      • Sensor drifting high in resistance after heat cycles

      Checks

      1. 1Measure the real temperature with a second thermometer once the engine has warmed up
      2. 2Compare the burner firing chamber temperature sensor value in SerDia with a neighbouring temperature; if only this one is cold the circuit is suspect
      3. 3Measure voltage drop across the connector with the engine running to find a high-resistance joint
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Exhaust aftertreatment - Burner firing chamber temperature - Data below normal operational range (Most severe level)

    • Deutz SPN 523921 FMI 2Exhaust aftertreatment - Burner firing chamber temperature: Erratic reading

      The EMR4 sees the burner firing chamber temperature sensor (in the burner firing chamber of the exhaust aftertreatment burner) jump around or disagree with other temperatures.· Erratic or implausible
      Check soon

      Causes

      • Intermittent contact in the connector or a pin with fretting
      • Harness chafed in a spot that makes contact only under vibration
      • Sensor element on its way out in the burner firing chamber temperature sensor

      Checks

      1. 1Watch the burner firing chamber temperature sensor value in SerDia while wiggling the harness and connector, and note when it jumps
      2. 2Inspect the connector for loose pins, bent terminals and moisture
      3. 3Check the harness along its route for chafe, especially where it crosses a bracket
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Exhaust aftertreatment - Burner firing chamber temperature - Data erratic intermittent or incorrect

    • Deutz SPN 523921 FMI 3Exhaust aftertreatment - Burner firing chamber temperature: Voltage high / shorted high

      The EMR4 reads the burner firing chamber temperature sensor (in the burner firing chamber of the exhaust aftertreatment burner) at a voltage above its valid window.· Shorted high
      Check soon

      Causes

      • Open circuit: broken wire, pushed-out pin or an unplugged connector at the burner firing chamber temperature sensor
      • Sensor element failed open, so its resistance stays very high at any temperature
      • Signal wire touching a supply voltage somewhere in the harness

      Checks

      1. 1Unplug the burner firing chamber temperature sensor and measure its resistance across the two pins; an NTC that reads open at room temperature is finished
      2. 2Bridge the two harness pins with a jumper wire with the key on; the code should change to the voltage-below-normal one if the harness is sound
      3. 3With the sensor unplugged and key on, check the signal pin for battery voltage, which would mean a short to supply
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Exhaust aftertreatment - Burner firing chamber temperature - Voltage above normal or shorted to high source

    • Deutz SPN 523921 FMI 4Exhaust aftertreatment - Burner firing chamber temperature: Voltage low / shorted low

      The EMR4 reads the burner firing chamber temperature sensor (in the burner firing chamber of the exhaust aftertreatment burner) at a voltage below its valid window.· Shorted low
      Check soon

      Causes

      • Signal wire rubbed through to the engine block or frame
      • Sensor element shorted internally, so it reads as extremely hot
      • Water bridging the pins inside the burner firing chamber temperature sensor connector

      Checks

      1. 1Unplug the burner firing chamber temperature sensor with the key on: if the code flips to the voltage-above-normal one, the harness is fine and the sensor is the shorted part
      2. 2With the EMR4 unplugged, measure resistance from the signal pin to ground; anything but open points to a short in the wire
      3. 3Measure the burner firing chamber temperature sensor resistance and compare it with its temperature; a very low value means the element is shorted
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Exhaust aftertreatment - Burner firing chamber temperature - Voltage below normal or shorted to low source

  • Engine - Air pressure glow plug flushing line1 code

    • Deutz SPN 524014 FMI 1Engine - Air pressure glow plug flushing line: Reading too low· most severe

      The EMR4 rates the air pressure glow plug flushing line (the fuel burner in the exhaust that heats the filter for regeneration) as below its allowed operating range, at the most severe level.· Real condition
      Check soon

      Causes

      • The monitored condition is really below its limit, for example a leak, a blockage or a part not working
      • Signal or part drifting low with age

      Checks

      1. 1Read the air pressure glow plug flushing line value in SerDia and compare it with an independent measurement before replacing parts
      2. 2Look for the real cause of a low value, such as a leak, a blocked line or a weak supply
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Engine - Air pressure glow plug flushing line - Data below normal operational range (Most severe level)

  • Exhaust aftertreatment - Burner fuel line1 code

    • Deutz SPN 524021 FMI 11Exhaust aftertreatment - Burner fuel line: Root cause not known

      The EMR4 logged a fault on the burner fuel line (the fuel burner in the exhaust that heats the filter for regeneration) but could not pin down the cause.· Other
      Check soon

      Causes

      • Intermittent wiring fault that has not stayed long enough to be classified
      • Failing part or a real condition the controller flagged

      Checks

      1. 1Read the full SerDia fault list; this code often appears next to a clearer one
      2. 2Inspect the connector and harness for chafed insulation, bent pins and moisture
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Exhaust aftertreatment - Standstill regeneration3 codes

    • Deutz SPN 524025 FMI 5Exhaust aftertreatment - Standstill regeneration: Current low / open circuit

      The EMR4 sees too little current in the standstill regeneration circuit (a regeneration run while the machine is parked, started by the operator), which means the circuit is open.· Open circuit
      Check soon

      Causes

      • Broken wire or a pin pushed out of the connector
      • Winding or element of the part open

      Checks

      1. 1Measure the resistance across the part terminals; infinity means an open element
      2. 2Continuity-test each wire to the matching EMR4 pin and inspect both connector ends
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

      Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

      Source wording:Exhaust aftertreatment - Standstill regeneration - Current below normal or open circuit

    • Deutz SPN 524025 FMI 8Exhaust aftertreatment - Standstill regeneration: Abnormal frequency / pulse width

      The EMR4 sees an abnormal frequency or pulse width on the standstill regeneration (a regeneration run while the machine is parked, started by the operator).· Erratic or implausible
      Check soon

      Causes

      • Electrical noise or a loose connection distorting the signal
      • Sensor or sending unit failing

      Checks

      1. 1Watch the standstill regeneration value in SerDia for jumps and dropouts
      2. 2Inspect the connector and harness for chafe, moisture and loose pins
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Exhaust aftertreatment - Standstill regeneration - Abnormal frequency or pulse width or period

    • Deutz SPN 524025 FMI 14Exhaust aftertreatment - Standstill regeneration: Special instructions

      The EMR4 flags the standstill regeneration (a regeneration run while the machine is parked, started by the operator) as a special instruction case.· Other
      Info

      Causes

      • A running condition that the EMR4 monitors has been reached
      • An earlier fault left a stored special instruction

      Checks

      1. 1Read the full SerDia list and the freeze frame data
      2. 2Check the machine service manual for the instruction that belongs to this condition
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Exhaust aftertreatment - Standstill regeneration request1 code

    • Deutz SPN 524195 FMI 14Exhaust aftertreatment - Standstill regeneration request: Special instructions

      The EMR4 flags the standstill regeneration request (a regeneration run while the machine is parked, started by the operator) as a special instruction case.· Other
      Info

      Causes

      • A running condition that the EMR4 monitors has been reached
      • An earlier fault left a stored special instruction

      Checks

      1. 1Read the full SerDia list and the freeze frame data
      2. 2Check the machine service manual for the instruction that belongs to this condition
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

Shared checks

Checks, in order

  1. 1Read the regeneration status and the interlock conditions in SerDia
  2. 2Check the burner chamber temperature sensor and its plug
  3. 3Check the burner fuel and air supply faults before repeating the regeneration
  4. 4Repeat a parked regeneration after the repair and watch the steps

Causes

  • Regeneration interrupted by the operator or by a machine condition
  • Burner failed to light or the firing chamber sensor reads wrongly
  • Burner fuel or air supply fault
  • Filter too loaded to regenerate safely

Most common here: erratic or implausible (5 of 19)

Watch the live value on the service tool while you flex the harness and tap the connector.

When to stop

You'll notice: A warning lamp or limited function.

Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.