Deutz · Exhaust aftertreatment (DPF/DOC)
Deutz Burner fuel pressure sensors and fuel metering valves fault codes
The fuel side of the regeneration burner: the fuel pressure sensors before and after the metering valve and after the dosing valve (SPN 523912, 523916, 523917), and the burner fuel metering and shut-off valves. Each code names the sensor or valve and whether its signal or drive failed.
Where to read it
Read the active and stored faults with Deutz SerDia (or the machine maker's diagnostic tool) on the engine diagnostic plug.
What do these codes mean?
Deutz codes SPN 523912 FMI 0 to SPN 523922 FMI 12 are all about the burner fuel pressure sensors and fuel metering valves. The most common failure type is shorted high (6 of 25); none needs an immediate stop. Start with this check: read the burner fuel pressure in SerDia while the valve is off and while it is commanded.
How urgent are they?
None of the 25 codes here means stop now; all 25 can wait until the shift ends, but find the cause before the next one.
- Check soon25
What should I check first?
Read the burner fuel pressure in SerDia while the valve is off and while it is commanded
Shared checks25 of 25
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Pressure sensor after burner dosing valve5 codes
Deutz SPN 523912 FMI 0Pressure sensor after burner dosing valve: Reading too high· most severe
The pressure sensor after burner dosing valve (on the burner fuel line downstream of the dosing valve) reports a value above the allowed range. This is a plausibility limit, so the high value may be genuine rather than a wiring fault. Deutz list: KWP code 66, blink code 7-2-2. For this code the controller rates the pressure sensor after burner dosing valve value as above its allowed range; the value may be real or a plausibility limit tripped. This is the sensor after the dosing valve, so it shows what pressure the dosing valve really delivers to the burner.· Real conditionReal conditionCheck soonCauses
- Pressure sensor after burner dosing valve drifting high or reading with an offset
- Hose or port feeding the sensor blocked with dirt
- Condition really above the limit, for example from overload or a blockage
Checks
- 1Check the real value against a mechanical gauge or second reading before touching the pressure sensor after burner dosing valve
- 2Compare with its neighbouring sensors in SerDia to see whether only this value is off
- 3Inspect the sensor port or hose for restriction
- 4Compare the pressure sensor after burner dosing valve reading in SerDia with an independent measurement to see whether the high value is real.
- 5Read the sensor with the valve closed and then commanded; the value should rise only when it opens.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:Exhaust aftertreatment - Pressure sensor after burner dosing valve - Data above normal operational range (Most severe level)
Deutz SPN 523912 FMI 1Pressure sensor after burner dosing valve: Reading too low· most severe
The pressure sensor after burner dosing valve (on the burner fuel line downstream of the dosing valve) reports a value below the allowed range. This is a plausibility limit, so the low value may be genuine rather than a wiring fault. Deutz list: KWP code 69, blink code 7-2-2. For this code the controller rates the pressure sensor after burner dosing valve value as below its allowed range; the value may be real or a plausibility limit tripped. This is the sensor after the dosing valve, so it shows what pressure the dosing valve really delivers to the burner.· Real conditionReal conditionCheck soonCauses
- Pressure sensor after burner dosing valve drifting low or reading with an offset
- Hose or port feeding the sensor split or disconnected
- Condition really below the limit, for example from a leak or a weak supply
Checks
- 1Check the real value with a mechanical gauge before replacing the pressure sensor after burner dosing valve
- 2Compare with its neighbouring sensors in SerDia to see whether only this value is off
- 3Inspect the sensor port, hose and seal for leaks
- 4Compare the pressure sensor after burner dosing valve reading in SerDia with an independent measurement to see whether the low value is real.
- 5Read the sensor with the valve closed and then commanded; the value should rise only when it opens.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:Exhaust aftertreatment - Pressure sensor after burner dosing valve - Data below normal operational range (Most severe level)
Deutz SPN 523912 FMI 2Pressure sensor after burner dosing valve: Erratic reading
The EMR4 sees the pressure sensor after burner dosing valve (on the burner fuel line downstream of the dosing valve) signal jump or disagree with other values. The signal is present but unstable, which usually means a loose joint or a failing sensor. Deutz list: KWP code 64, blink code 7-2-2. For this code the pressure sensor after burner dosing valve signal is erratic: it jumps or does not agree with what the controller expects, which usually means an intermittent contact. This is the sensor after the dosing valve, so it shows what pressure the dosing valve really delivers to the burner.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Intermittent contact in the connector
- Harness chafed against a bracket in a spot that only touches under vibration
- Pressure sensor after burner dosing valve on its way out
- Loose pin or damaged wire that makes the signal drop out
Checks
- 1Watch the pressure sensor after burner dosing valve value in SerDia while wiggling the connector and harness
- 2Inspect the connector for loose pins, bent terminals and moisture
- 3Check the 5 V reference for dips while the fault shows
- 4Wiggle the harness at the pressure sensor after burner dosing valve while watching the live value in SerDia; a jump exposes a loose pin or a chafed wire.
- 5Read the sensor with the valve closed and then commanded; the value should rise only when it opens.
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:Exhaust aftertreatment - Pressure sensor after burner dosing valve - Data erratic intermittent or incorrect
Deutz SPN 523912 FMI 3Pressure sensor after burner dosing valve: Voltage high / shorted high
The EMR4 reads the pressure sensor after burner dosing valve (on the burner fuel line downstream of the dosing valve) signal above its valid 0.5 to 4.5 V window. That points to an open sensor ground, a short to supply on the signal wire, or a failed sensor. Deutz list: KWP code 72, blink code 722. For this code the controller read the pressure sensor after burner dosing valve circuit at a voltage above normal, as if the wire or the driver were pulled up to the supply voltage, for instance by a chafed harness touching a live wire. This is the sensor after the dosing valve, so it shows what pressure the dosing valve really delivers to the burner.· Shorted highShorted highCheck soonCauses
- Open ground return wire, which pushes the signal up to the reference
- Signal wire touching 5 V or battery in the harness
- Pressure sensor after burner dosing valve failed high
- Harness insulation worn through where it rubs on a bracket, letting the wire touch a live supply
Checks
- 1Key on: measure the 5 V reference at the pressure sensor after burner dosing valve plug between supply and ground; 5 V present means the supply side is fine
- 2Check continuity of the sensor ground wire back to the EMR4 pin
- 3With the sensor unplugged, measure the signal pin; battery voltage there means a short to supply
- 4With the EMR4 and the pressure sensor after burner dosing valve unplugged, measure the signal wire against battery positive; it must read open, and any reading means the harness is shorted high.
- 5Read the sensor with the valve closed and then commanded; the value should rise only when it opens.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Exhaust aftertreatment - Pressure sensor after burner dosing valve - Voltage above normal or shorted to high source
Deutz SPN 523912 FMI 4Pressure sensor after burner dosing valve: Voltage low / shorted low
The EMR4 reads the pressure sensor after burner dosing valve (on the burner fuel line downstream of the dosing valve) signal below its valid 0.5 to 4.5 V window. That points to a shorted signal wire, a lost 5 V reference, or a failed sensor. Deutz list: KWP code 73, blink code 722. For this code the controller read the pressure sensor after burner dosing valve circuit at a voltage below normal, as if it were tied to ground, which points to a wire rubbing through on the frame or a part shorted to its housing. This is the sensor after the dosing valve, so it shows what pressure the dosing valve really delivers to the burner.· Shorted lowShorted lowCheck soonCauses
- Signal wire rubbed through to ground
- 5 V reference lost: open supply wire or a short on the shared 5 V line
- Pressure sensor after burner dosing valve failed low
- Wire pinched against the engine block or frame so the signal is pulled to ground
Checks
- 1Key on: measure the 5 V reference at the pressure sensor after burner dosing valve plug; no reference means open supply wire or another sensor on that line pulling it down
- 2With the sensor unplugged, measure resistance from the signal pin to ground; it should not be near zero
- 3Unplug other sensors sharing the 5 V line one at a time to see whether the reference comes back
- 4With the connector unplugged, measure the pressure sensor after burner dosing valve signal wire against ground; a low resistance means a harness short, while an open reading sends you to the part itself.
- 5Read the sensor with the valve closed and then commanded; the value should rise only when it opens.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Exhaust aftertreatment - Pressure sensor after burner dosing valve - Voltage below normal or shorted to low source
Burner post injection metering valve6 codes
Deutz SPN 523915 FMI 0Burner post injection metering valve: Reading too high· most severe
The EMR4 sees the burner post injection metering valve (on the aftertreatment burner fuel path) above its allowed range. The controller treats this as a serious level. Deutz list: KWP code 500, blink code 165. For this code the controller rates the burner post injection metering valve value as above its allowed range; the value may be real or a plausibility limit tripped. The post-injection metering valve controls fuel for the burner flame.· Real conditionReal conditionCheck soonCauses
- Part driven beyond its limit
- Valve stuck by fuel varnish
- Condition really above the limit, for example from overload or a blockage
Checks
- 1Read the actual value against the target in SerDia
- 2Check the burner post injection metering valve moves freely through its range by hand with the key off
- 3Inspect the supply and control wiring of the burner post injection metering valve for chafe, water and corrosion
- 4Compare the burner post injection metering valve reading in SerDia with an independent measurement to see whether the high value is real.
- 5Measure the coil of the post-injection metering valve and listen for it switching.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:Exhaust aftertreatment - Burner post injection metering valve - Data above normal operational range (Most severe level)
Deutz SPN 523915 FMI 3Burner post injection metering valve: Voltage high / shorted high
The EMR4 sees the output for the burner post injection metering valve (on the aftertreatment burner fuel path) at a voltage above normal, as if the circuit is shorted to the battery supply. The controller cannot drive the actuator correctly. Deutz list: KWP codes 502 (blink 159), 503 (blink 164). For this code the controller read the burner post injection metering valve circuit at a voltage above normal, as if the wire or the driver were pulled up to the supply voltage, for instance by a chafed harness touching a live wire. The post-injection metering valve controls fuel for the burner flame.· Shorted highShorted highCheck soonCauses
- Output wire shorted to battery positive
- Connector pin touching a live pin
- Burner post injection metering valve shorted internally
- Harness insulation worn through where it rubs on a bracket, letting the wire touch a live supply
Checks
- 1Unplug the burner post injection metering valve: if the code stays, the short is in the harness or the EMR4; if it clears, the part is the shorted one
- 2With the EMR4 unplugged, measure the output wire to battery positive; it should be open
- 3Measure the winding or coil resistance of the part
- 4With the EMR4 and the burner post injection metering valve unplugged, measure the signal wire against battery positive; it must read open, and any reading means the harness is shorted high.
- 5Measure the coil of the post-injection metering valve and listen for it switching.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Exhaust aftertreatment - Burner post injection metering valve - Voltage above normal or shorted to high source
Deutz SPN 523915 FMI 4Burner post injection metering valve: Voltage low / shorted low
The EMR4 sees the output for the burner post injection metering valve (on the aftertreatment burner fuel path) at a voltage below normal, as if the circuit is shorted to ground. The controller cannot drive the actuator correctly. Deutz list: KWP code 504, blink code 159. For this code the controller read the burner post injection metering valve circuit at a voltage below normal, as if it were tied to ground, which points to a wire rubbing through on the frame or a part shorted to its housing. The post-injection metering valve controls fuel for the burner flame.· Shorted lowShorted lowCheck soonCauses
- Output wire chafed to ground or the engine block
- Burner post injection metering valve winding shorted to its housing
- Water in the connector bridging the pins
- Wire pinched against the engine block or frame so the signal is pulled to ground
Checks
- 1Unplug the burner post injection metering valve: if the code changes, the part is the shorted one; if it stays, look at the harness
- 2With the EMR4 unplugged, measure the output wire to ground; it should not be low ohms
- 3Measure the winding resistance of the part and look for a very low value
- 4With the connector unplugged, measure the burner post injection metering valve signal wire against ground; a low resistance means a harness short, while an open reading sends you to the part itself.
- 5Measure the coil of the post-injection metering valve and listen for it switching.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Exhaust aftertreatment - Burner post injection metering valve - Voltage below normal or shorted to low source
Deutz SPN 523915 FMI 7Burner post injection metering valve: Not responding / out of adjustment
The EMR4 sees the burner post injection metering valve (on the aftertreatment burner fuel path) not following its commanded position or movement. The signal is fine; the part itself is not moving as it should. Deutz list: KWP code 1257, blink code 8-5-3. For this code the burner post injection metering valve was commanded but did not follow, so the fault is mechanical (sticking, wear or soot) rather than electrical. The post-injection metering valve controls fuel for the burner flame.· Part or controllerPart or controllerCheck soonCauses
- Valve stuck by fuel varnish
- Failed part or a real condition behind the signal
- Soot, carbon or dried residue binding the moving parts
Checks
- 1Move the part by hand with the key off to see whether it is stuck
- 2Command it from SerDia and watch actual position against commanded
- 3Inspect for soot, oil or foreign matter around the part
- 4Move the burner post injection metering valve by hand with the key off to feel for sticking, play or soot before you test the electrics.
- 5Measure the coil of the post-injection metering valve and listen for it switching.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Source wording:Exhaust aftertreatment - Burner post injection metering valve - Mechanical system not responding or out of adjustment
Deutz SPN 523915 FMI 11Burner post injection metering valve: Root cause not known
The EMR4 logged a fault on the burner post injection metering valve (on the aftertreatment burner fuel path) but could not classify the cause. Test the circuit and the part separately. Deutz list: KWP code 505, blink code 164. For this code the controller flagged the burner post injection metering valve but could not tell whether wiring, part or supply is to blame. The post-injection metering valve controls fuel for the burner flame.· OtherOtherCheck soonCauses
- Intermittent wiring fault
- Failing burner post injection metering valve
- Intermittent contact that left no clear electrical signature
Checks
- 1Read the full SerDia fault list; this code often sits next to a clearer one on the burner post injection metering valve
- 2Measure the supply and ground at the burner post injection metering valve plug with the key on to confirm it is powered
- 3Inspect the burner post injection metering valve plug and harness for chafed insulation, bent pins and moisture
- 4Read the freeze frame stored with the burner post injection metering valve fault and note speed, load and battery voltage at the moment it was logged.
- 5Measure the coil of the post-injection metering valve and listen for it switching.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Deutz SPN 523915 FMI 12Burner post injection metering valve: Bad device or component
The EMR4 judges the burner post injection metering valve (on the aftertreatment burner fuel path) to be a bad device, meaning the part or its driver electronics no longer respond as a working component. Deutz list: KWP code 501, blink code 166. For this code the burner post injection metering valve reports an internal fault to the controller, so the electronics inside the part have judged themselves defective. The post-injection metering valve controls fuel for the burner flame.· Part or controllerPart or controllerCheck soonCauses
- Internal failure of the burner post injection metering valve
- Water or soot inside the part
- Driver stage in the EMR4 failing
- Electronics inside the part damaged by heat, water or a voltage spike
Checks
- 1Read the burner post injection metering valve status in SerDia and run any actuator test
- 2Measure supply voltage and ground at the burner post injection metering valve connector with the key on to confirm the part is powered
- 3Fit a known good burner post injection metering valve if you can borrow one and see whether the code clears for good
- 4Check supply voltage and ground at the burner post injection metering valve connector under load; if both are good the part itself is the likely culprit and a swap with a known good one confirms it.
- 5Measure the coil of the post-injection metering valve and listen for it switching.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Source wording:Exhaust aftertreatment - Burner post injection metering valve - Bad intelligent device or component
Fuel pressure sensor after burner post injection metering valve5 codes
Deutz SPN 523916 FMI 0Fuel pressure sensor after burner post injection metering valve: Reading too high· most severe
The fuel pressure sensor after burner post injection metering valve (on the burner fuel path after the metering valve) reports a value above the allowed range. This is a plausibility limit, so the high value may be genuine rather than a wiring fault. Deutz list: KWP code 508, blink code 719. For this code the controller rates the fuel pressure sensor after burner post injection metering valve value as above its allowed range; the value may be real or a plausibility limit tripped. This sensor sits after the post-injection metering valve, so it confirms the metered fuel reaches the burner line.· Real conditionReal conditionCheck soonCauses
- Fuel pressure sensor after burner post injection metering valve drifting high or reading with an offset
- Hose or port feeding the sensor blocked with dirt
- Condition really above the limit, for example from overload or a blockage
Checks
- 1Check the real value against a mechanical gauge or second reading before touching the fuel pressure sensor after burner post injection metering valve
- 2Compare with its neighbouring sensors in SerDia to see whether only this value is off
- 3Inspect the sensor port or hose for restriction
- 4Compare the fuel pressure sensor after burner post injection metering valve reading in SerDia with an independent measurement to see whether the high value is real.
- 5Compare it with the sensor before the valve to see where the pressure is lost.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:Exhaust aftertreatment - Fuel pressure sensor after burner post injection metering valve - Data above normal operational range (Most severe level)
Deutz SPN 523916 FMI 1Fuel pressure sensor after burner post injection metering valve: Reading too low· most severe
The fuel pressure sensor after burner post injection metering valve (on the burner fuel path after the metering valve) reports a value below the allowed range. This is a plausibility limit, so the low value may be genuine rather than a wiring fault. Deutz list: KWP code 511, blink code 719. For this code the controller rates the fuel pressure sensor after burner post injection metering valve value as below its allowed range; the value may be real or a plausibility limit tripped. This sensor sits after the post-injection metering valve, so it confirms the metered fuel reaches the burner line.· Real conditionReal conditionCheck soonCauses
- Fuel pressure sensor after burner post injection metering valve drifting low or reading with an offset
- Hose or port feeding the sensor split or disconnected
- Condition really below the limit, for example from a leak or a weak supply
Checks
- 1Check the real value with a mechanical gauge before replacing the fuel pressure sensor after burner post injection metering valve
- 2Compare with its neighbouring sensors in SerDia to see whether only this value is off
- 3Inspect the sensor port, hose and seal for leaks
- 4Compare the fuel pressure sensor after burner post injection metering valve reading in SerDia with an independent measurement to see whether the low value is real.
- 5Compare it with the sensor before the valve to see where the pressure is lost.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:Exhaust aftertreatment - Fuel pressure sensor after burner post injection metering valve - Data below normal operational range (Most severe level)
Deutz SPN 523916 FMI 2Fuel pressure sensor after burner post injection metering valve: Erratic reading
The EMR4 sees the fuel pressure sensor after burner post injection metering valve (on the burner fuel path after the metering valve) signal jump or disagree with other values. The signal is present but unstable, which usually means a loose joint or a failing sensor. Deutz list: KWP code 506, blink code 719. For this code the fuel pressure sensor after burner post injection metering valve signal is erratic: it jumps or does not agree with what the controller expects, which usually means an intermittent contact. This sensor sits after the post-injection metering valve, so it confirms the metered fuel reaches the burner line.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Intermittent contact in the connector
- Harness chafed against a bracket in a spot that only touches under vibration
- Fuel pressure sensor after burner post injection metering valve on its way out
- Loose pin or damaged wire that makes the signal drop out
Checks
- 1Watch the fuel pressure sensor after burner post injection metering valve value in SerDia while wiggling the connector and harness
- 2Inspect the connector for loose pins, bent terminals and moisture
- 3Check the 5 V reference for dips while the fault shows
- 4Wiggle the harness at the fuel pressure sensor after burner post injection metering valve while watching the live value in SerDia; a jump exposes a loose pin or a chafed wire.
- 5Compare it with the sensor before the valve to see where the pressure is lost.
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:Exhaust aftertreatment - Fuel pressure sensor after burner post injection metering valve - Data erratic intermittent or incorrect
Deutz SPN 523916 FMI 3Fuel pressure sensor after burner post injection metering valve: Voltage high / shorted high
The EMR4 reads the fuel pressure sensor after burner post injection metering valve (on the burner fuel path after the metering valve) signal above its valid 0.5 to 4.5 V window. That points to an open sensor ground, a short to supply on the signal wire, or a failed sensor. Deutz list: KWP code 514, blink code 719. For this code the controller read the fuel pressure sensor after burner post injection metering valve circuit at a voltage above normal, as if the wire or the driver were pulled up to the supply voltage, for instance by a chafed harness touching a live wire. This sensor sits after the post-injection metering valve, so it confirms the metered fuel reaches the burner line.· Shorted highShorted highCheck soonCauses
- Open ground return wire, which pushes the signal up to the reference
- Signal wire touching 5 V or battery in the harness
- Fuel pressure sensor after burner post injection metering valve failed high
- Harness insulation worn through where it rubs on a bracket, letting the wire touch a live supply
Checks
- 1Key on: measure the 5 V reference at the fuel pressure sensor after burner post injection metering valve plug between supply and ground; 5 V present means the supply side is fine
- 2Check continuity of the sensor ground wire back to the EMR4 pin
- 3With the sensor unplugged, measure the signal pin; battery voltage there means a short to supply
- 4With the EMR4 and the fuel pressure sensor after burner post injection metering valve unplugged, measure the signal wire against battery positive; it must read open, and any reading means the harness is shorted high.
- 5Compare it with the sensor before the valve to see where the pressure is lost.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Exhaust aftertreatment - Fuel pressure sensor after burner post injection metering valve - Voltage above normal or shorted to high source
Deutz SPN 523916 FMI 4Fuel pressure sensor after burner post injection metering valve: Voltage low / shorted low
The EMR4 reads the fuel pressure sensor after burner post injection metering valve (on the burner fuel path after the metering valve) signal below its valid 0.5 to 4.5 V window. That points to a shorted signal wire, a lost 5 V reference, or a failed sensor. Deutz list: KWP code 515, blink code 719. For this code the controller read the fuel pressure sensor after burner post injection metering valve circuit at a voltage below normal, as if it were tied to ground, which points to a wire rubbing through on the frame or a part shorted to its housing. This sensor sits after the post-injection metering valve, so it confirms the metered fuel reaches the burner line.· Shorted lowShorted lowCheck soonCauses
- Signal wire rubbed through to ground
- 5 V reference lost: open supply wire or a short on the shared 5 V line
- Fuel pressure sensor after burner post injection metering valve failed low
- Wire pinched against the engine block or frame so the signal is pulled to ground
Checks
- 1Key on: measure the 5 V reference at the fuel pressure sensor after burner post injection metering valve plug; no reference means open supply wire or another sensor on that line pulling it down
- 2With the sensor unplugged, measure resistance from the signal pin to ground; it should not be near zero
- 3Unplug other sensors sharing the 5 V line one at a time to see whether the reference comes back
- 4With the connector unplugged, measure the fuel pressure sensor after burner post injection metering valve signal wire against ground; a low resistance means a harness short, while an open reading sends you to the part itself.
- 5Compare it with the sensor before the valve to see where the pressure is lost.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Exhaust aftertreatment - Fuel pressure sensor after burner post injection metering valve - Voltage below normal or shorted to low source
Pressure before burner fuel valve2 codes
Deutz SPN 523917 FMI 3Pressure before burner fuel valve: Voltage high / shorted high
The EMR4 reads the pressure before burner fuel valve (on the burner fuel path after the metering valve) signal above its valid 0.5 to 4.5 V window. That points to an open sensor ground, a short to supply on the signal wire, or a failed sensor. Deutz list: KWP code 524, blink code 718. For this code the controller read the pressure before burner fuel valve circuit at a voltage above normal, as if the wire or the driver were pulled up to the supply voltage, for instance by a chafed harness touching a live wire. This sensor sits before the burner fuel valve and shows the supply pressure the burner starts from.· Shorted highShorted highCheck soonCauses
- Open ground return wire, which pushes the signal up to the reference
- Signal wire touching 5 V or battery in the harness
- Pressure before burner fuel valve failed high
- Harness insulation worn through where it rubs on a bracket, letting the wire touch a live supply
Checks
- 1Key on: measure the 5 V reference at the pressure before burner fuel valve plug between supply and ground; 5 V present means the supply side is fine
- 2Check continuity of the sensor ground wire back to the EMR4 pin
- 3With the sensor unplugged, measure the signal pin; battery voltage there means a short to supply
- 4With the EMR4 and the pressure before burner fuel valve unplugged, measure the signal wire against battery positive; it must read open, and any reading means the harness is shorted high.
- 5Check the burner fuel feed line and filter upstream of the sensor.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Exhaust aftertreatment - Pressure before burner fuel valve - Voltage above normal or shorted to high source
Deutz SPN 523917 FMI 4Pressure before burner fuel valve: Voltage low / shorted low
The EMR4 reads the pressure before burner fuel valve (on the burner fuel path after the metering valve) signal below its valid 0.5 to 4.5 V window. That points to a shorted signal wire, a lost 5 V reference, or a failed sensor. Deutz list: KWP code 525, blink code 718. For this code the controller read the pressure before burner fuel valve circuit at a voltage below normal, as if it were tied to ground, which points to a wire rubbing through on the frame or a part shorted to its housing. This sensor sits before the burner fuel valve and shows the supply pressure the burner starts from.· Shorted lowShorted lowCheck soonCauses
- Signal wire rubbed through to ground
- 5 V reference lost: open supply wire or a short on the shared 5 V line
- Pressure before burner fuel valve failed low
- Wire pinched against the engine block or frame so the signal is pulled to ground
Checks
- 1Key on: measure the 5 V reference at the pressure before burner fuel valve plug; no reference means open supply wire or another sensor on that line pulling it down
- 2With the sensor unplugged, measure resistance from the signal pin to ground; it should not be near zero
- 3Unplug other sensors sharing the 5 V line one at a time to see whether the reference comes back
- 4With the connector unplugged, measure the pressure before burner fuel valve signal wire against ground; a low resistance means a harness short, while an open reading sends you to the part itself.
- 5Check the burner fuel feed line and filter upstream of the sensor.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Exhaust aftertreatment - Pressure before burner fuel valve - Voltage below normal or shorted to low source
Burner metering unit2 codes
Deutz SPN 523918 FMI 3Burner metering unit: Voltage high / shorted high
The EMR4 sees the output for the burner metering unit (on the aftertreatment burner fuel path) at a voltage above normal, as if the circuit is shorted to the battery supply. The controller cannot drive the actuator correctly. Deutz list: KWP code 534, blink code 717. For this code the controller read the burner metering unit circuit at a voltage above normal, as if the wire or the driver were pulled up to the supply voltage, for instance by a chafed harness touching a live wire. The burner metering unit sets the quantity of fuel the burner gets.· Shorted highShorted highCheck soonCauses
- Output wire shorted to battery positive
- Connector pin touching a live pin
- Burner metering unit shorted internally
- Harness insulation worn through where it rubs on a bracket, letting the wire touch a live supply
Checks
- 1Unplug the burner metering unit: if the code stays, the short is in the harness or the EMR4; if it clears, the part is the shorted one
- 2With the EMR4 unplugged, measure the output wire to battery positive; it should be open
- 3Measure the winding or coil resistance of the part
- 4With the EMR4 and the burner metering unit unplugged, measure the signal wire against battery positive; it must read open, and any reading means the harness is shorted high.
- 5Measure the metering unit coil and check its plug.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Exhaust aftertreatment - Burner metering unit - Voltage above normal or shorted to high source
Deutz SPN 523918 FMI 4Burner metering unit: Voltage low / shorted low
The EMR4 sees the output for the burner metering unit (on the aftertreatment burner fuel path) at a voltage below normal, as if the circuit is shorted to ground. The controller cannot drive the actuator correctly. Deutz list: KWP code 535, blink code 717. For this code the controller read the burner metering unit circuit at a voltage below normal, as if it were tied to ground, which points to a wire rubbing through on the frame or a part shorted to its housing. The burner metering unit sets the quantity of fuel the burner gets.· Shorted lowShorted lowCheck soonCauses
- Output wire chafed to ground or the engine block
- Burner metering unit winding shorted to its housing
- Water in the connector bridging the pins
- Wire pinched against the engine block or frame so the signal is pulled to ground
Checks
- 1Unplug the burner metering unit: if the code changes, the part is the shorted one; if it stays, look at the harness
- 2With the EMR4 unplugged, measure the output wire to ground; it should not be low ohms
- 3Measure the winding resistance of the part and look for a very low value
- 4With the connector unplugged, measure the burner metering unit signal wire against ground; a low resistance means a harness short, while an open reading sends you to the part itself.
- 5Measure the metering unit coil and check its plug.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Exhaust aftertreatment - Burner metering unit - Voltage below normal or shorted to low source
Burner metering unit shut-off valve5 codes
Deutz SPN 523922 FMI 3Burner metering unit shut-off valve: Voltage high / shorted high
The EMR4 sees the output for the burner metering unit shut-off valve (on the aftertreatment burner fuel path) at a voltage above normal, as if the circuit is shorted to the battery supply. The controller cannot drive the actuator correctly. Deutz list: KWP code 965, blink code 715. For this code the controller read the burner metering unit shut-off valve circuit at a voltage above normal, as if the wire or the driver were pulled up to the supply voltage, for instance by a chafed harness touching a live wire. The shut-off valve closes the burner fuel line when no regeneration is running.· Shorted highShorted highCheck soonCauses
- Output wire shorted to battery positive
- Connector pin touching a live pin
- Burner metering unit shut-off valve shorted internally
- Harness insulation worn through where it rubs on a bracket, letting the wire touch a live supply
Checks
- 1Unplug the burner metering unit shut-off valve: if the code stays, the short is in the harness or the EMR4; if it clears, the part is the shorted one
- 2With the EMR4 unplugged, measure the output wire to battery positive; it should be open
- 3Measure the winding or coil resistance of the part
- 4With the EMR4 and the burner metering unit shut-off valve unplugged, measure the signal wire against battery positive; it must read open, and any reading means the harness is shorted high.
- 5Check that the shut-off valve closes fully when off, since a leak lets fuel into a cold burner.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Exhaust aftertreatment - Burner metering unit shut-off valve - Voltage above normal or shorted to high source
Deutz SPN 523922 FMI 4Burner metering unit shut-off valve: Voltage low / shorted low
The EMR4 sees the output for the burner metering unit shut-off valve (on the aftertreatment burner fuel path) at a voltage below normal, as if the circuit is shorted to ground. The controller cannot drive the actuator correctly. Deutz list: KWP code 1392, blink code 715. For this code the controller read the burner metering unit shut-off valve circuit at a voltage below normal, as if it were tied to ground, which points to a wire rubbing through on the frame or a part shorted to its housing. The shut-off valve closes the burner fuel line when no regeneration is running.· Shorted lowShorted lowCheck soonCauses
- Output wire chafed to ground or the engine block
- Burner metering unit shut-off valve winding shorted to its housing
- Water in the connector bridging the pins
- Wire pinched against the engine block or frame so the signal is pulled to ground
Checks
- 1Unplug the burner metering unit shut-off valve: if the code changes, the part is the shorted one; if it stays, look at the harness
- 2With the EMR4 unplugged, measure the output wire to ground; it should not be low ohms
- 3Measure the winding resistance of the part and look for a very low value
- 4With the connector unplugged, measure the burner metering unit shut-off valve signal wire against ground; a low resistance means a harness short, while an open reading sends you to the part itself.
- 5Check that the shut-off valve closes fully when off, since a leak lets fuel into a cold burner.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Exhaust aftertreatment - Burner metering unit shut-off valve - Voltage below normal or shorted to low source
Deutz SPN 523922 FMI 5Burner metering unit shut-off valve: Current low / open circuit
The EMR4 sees too little current through the burner metering unit shut-off valve (on the aftertreatment burner fuel path), which means the circuit is open. The controller commands the actuator but nothing flows. Deutz list: KWP code 1389, blink code 715. For this code the controller measured too little current in the burner metering unit shut-off valve circuit, the signature of an open wire, a pulled-out pin or a burnt-out coil. The shut-off valve closes the burner fuel line when no regeneration is running.· Open circuitOpen circuitCheck soonCauses
- Broken wire or a pin pushed out of the connector
- Burner metering unit shut-off valve winding open
- Connector left unplugged after earlier work
- Terminal pushed back or corroded in its connector so the circuit is open
Checks
- 1Measure the resistance across the burner metering unit shut-off valve terminals: infinity means an open winding
- 2Continuity-test each wire to the matching EMR4 pin
- 3Inspect both ends of the burner metering unit shut-off valve circuit (EMR4 plug and part connector) for pins pushed back in the housing
- 4Check the continuity of both wires between the EMR4 plug and the burner metering unit shut-off valve connector, then the coil resistance, to separate a broken wire from a dead coil.
- 5Check that the shut-off valve closes fully when off, since a leak lets fuel into a cold burner.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Source wording:Exhaust aftertreatment - Burner metering unit shut-off valve - Current below normal or open circuit
Deutz SPN 523922 FMI 7Burner metering unit shut-off valve: Not responding / out of adjustment
The EMR4 sees the burner metering unit shut-off valve (on the aftertreatment burner fuel path) not following its commanded position or movement. The signal is fine; the part itself is not moving as it should. Deutz list: KWP codes 1262 (blink 8-5-4), 1264 (blink 8-5-5). For this code the burner metering unit shut-off valve was commanded but did not follow, so the fault is mechanical (sticking, wear or soot) rather than electrical. The shut-off valve closes the burner fuel line when no regeneration is running.· Part or controllerPart or controllerCheck soonCauses
- Valve stuck by fuel varnish
- Failed part or a real condition behind the signal
- Soot, carbon or dried residue binding the moving parts
Checks
- 1Move the part by hand with the key off to see whether it is stuck
- 2Command it from SerDia and watch actual position against commanded
- 3Inspect for soot, oil or foreign matter around the part
- 4Move the burner metering unit shut-off valve by hand with the key off to feel for sticking, play or soot before you test the electrics.
- 5Check that the shut-off valve closes fully when off, since a leak lets fuel into a cold burner.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Source wording:Exhaust aftertreatment - Burner metering unit shut-off valve - Mechanical system not responding or out of adjustment
Deutz SPN 523922 FMI 12Burner metering unit shut-off valve: Bad device or component
The EMR4 judges the burner metering unit shut-off valve (on the aftertreatment burner fuel path) to be a bad device, meaning the part or its driver electronics no longer respond as a working component. Deutz list: KWP code 1390, blink code 715. For this code the burner metering unit shut-off valve reports an internal fault to the controller, so the electronics inside the part have judged themselves defective. The shut-off valve closes the burner fuel line when no regeneration is running.· Part or controllerPart or controllerCheck soonCauses
- Internal failure of the burner metering unit shut-off valve
- Water or soot inside the part
- Driver stage in the EMR4 failing
- Electronics inside the part damaged by heat, water or a voltage spike
Checks
- 1Read the burner metering unit shut-off valve status in SerDia and run any actuator test
- 2Measure supply voltage and ground at the burner metering unit shut-off valve connector with the key on to confirm the part is powered
- 3Fit a known good burner metering unit shut-off valve if you can borrow one and see whether the code clears for good
- 4Check supply voltage and ground at the burner metering unit shut-off valve connector under load; if both are good the part itself is the likely culprit and a swap with a known good one confirms it.
- 5Check that the shut-off valve closes fully when off, since a leak lets fuel into a cold burner.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Source wording:Exhaust aftertreatment - Burner metering unit shut-off valve - Bad intelligent device or component
Shared checks
Checks, in order
- 1Read the burner fuel pressure in SerDia while the valve is off and while it is commanded
- 2Measure the coil resistance of the valve named in the code
- 3Inspect the burner fuel line, fittings and sensor connectors for leaks and corrosion
- 4Check the valve command in SerDia to confirm the valve opens
Causes
- Burner fuel line blocked or leaking so the real pressure is wrong
- Valve coil open or shorted, or its plug corroded
- Valve stuck so no pressure builds
- Pressure sensor failed from age
Most common here: shorted high (6 of 25)
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
When to stop
You'll notice: A warning lamp or limited function.
Common-rail fuel runs at very high pressure. Never open a high-pressure line or fitting with the engine running or just after it stops - a fine fuel jet can pierce skin.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.