Deutz · Exhaust aftertreatment (DPF/DOC)
Deutz Burner air pump, air pressure, exhaust back pressure and dosing valve fault codes
The air side of the regeneration burner. The burner air pump (SPN 523910) and its pressure sensor (SPN 523919), the air mass sensor and air line, the exhaust back pressure sensor at the burner (SPN 523920), and the burner dosing valve.
More about these partsLess
Each code names the part and how it failed.
Where to read it
Read the active and stored faults with Deutz SerDia (or the machine maker's diagnostic tool) on the engine diagnostic plug.
What do these codes mean?
Deutz codes SPN 523910 FMI 0 to SPN 524019 FMI 11 are all about the burner air pump, air pressure, exhaust back pressure and dosing valve. The most common failure type is real condition (6 of 21); none needs an immediate stop. Start with this check: listen for the pump at the start of a burner run and read its status in SerDia.
How urgent are they?
None of the 21 codes here means stop now; 20 can wait until the shift ends, but find the cause before the next one; 1 is information only.
- Check soon20
- Info1
What should I check first?
Listen for the pump at the start of a burner run and read its status in SerDia
Shared checks21 of 21
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Burner air pump6 codes
Deutz SPN 523910 FMI 0Burner air pump: Reading too high· most severe
The EMR4 sees the burner air pump (in the burner air supply of the aftertreatment system) above its allowed range. The controller treats this as a serious level. Deutz list: KWP code 1252, blink code 6-9-5.· Real conditionReal conditionCheck soonCauses
- Part driven beyond its limit
- Failed part or a real condition behind the signal
Checks
- 1Read the actual value against the target in SerDia
- 2Check the burner air pump moves freely through its range by hand with the key off
- 3Inspect the supply and control wiring of the burner air pump for chafe, water and corrosion
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:Exhaust aftertreatment - Burner air pump - Data above normal operational range (Most severe level)
Deutz SPN 523910 FMI 6Burner air pump: Current high / grounded
The EMR4 sees too much current through the burner air pump (in the burner air supply of the aftertreatment system). A shorted winding or wiring fault is drawing more current than the controller allows. Deutz list: KWP code 1261, blink code 6-9-5.· Shorted lowShorted lowCheck soonCauses
- Winding partly shorted inside the part
- Wire chafed to ground
Checks
- 1Measure the burner air pump winding resistance; a low value means it is shorting
- 2Check the wiring for chafe and for water in the connector
- 3Move the part by hand with the key off to see whether it is seized
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Exhaust aftertreatment - Burner air pump - Current above normal or grounded circuit
Deutz SPN 523910 FMI 7Burner air pump: Not responding / out of adjustment
The EMR4 sees the burner air pump (in the burner air supply of the aftertreatment system) not following its commanded position or movement. The signal is fine; the part itself is not moving as it should. Deutz list: KWP code 1249, blink code 6-9-5.· Part or controllerPart or controllerCheck soonCauses
- Wiring or connector fault in the circuit
- Failed part or a real condition behind the signal
Checks
- 1Move the part by hand with the key off to see whether it is stuck
- 2Command it from SerDia and watch actual position against commanded
- 3Inspect for soot, oil or foreign matter around the part
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Source wording:Exhaust aftertreatment - Burner air pump - Mechanical system not responding or out of adjustment
Deutz SPN 523910 FMI 9Burner air pump: Abnormal update rate timeout
The EMR4 sees the burner air pump (in the burner air supply of the aftertreatment system) update at an abnormal rate or time out. The data arrives too slowly or not at all. Deutz list: KWP code 1248, blink code 6-9-5.· Lost messageLost messageCheck soonCauses
- Interrupted wiring or connector to the sending unit
- Sending unit not powered or in reset
Checks
- 1Check the supply and ground of the sending unit with the key on
- 2Inspect the connector and wiring for chafe, moisture and loose pins
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Deutz SPN 523910 FMI 12Burner air pump: Bad device or component
The EMR4 judges the burner air pump (in the burner air supply of the aftertreatment system) to be a bad device, meaning the part or its driver electronics no longer respond as a working component. Deutz list: KWP code 1250, blink code 6-9-5.· Part or controllerPart or controllerCheck soonCauses
- Internal failure of the burner air pump
- Water or soot inside the part
- Driver stage in the EMR4 failing
Checks
- 1Read the burner air pump status in SerDia and run any actuator test
- 2Measure supply voltage and ground at the burner air pump connector with the key on to confirm the part is powered
- 3Fit a known good burner air pump if you can borrow one and see whether the code clears for good
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Source wording:Exhaust aftertreatment - Burner air pump - Bad intelligent device or component
Deutz SPN 523910 FMI 14Burner air pump: Special instructions
The EMR4 flags the burner air pump (in the burner air supply of the aftertreatment system) as a special instruction case. This is an informational or conditional event rather than a standard wiring fault. Deutz list: KWP code 55, blink code 6-9-5.· OtherOtherInfoCauses
- A running condition the EMR4 monitors
- Failed part or a real condition behind the signal
Checks
- 1Read the full SerDia list and the freeze frame data
- 2Check the machine service manual for the special instruction
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Burner dosing valve3 codes
Deutz SPN 523911 FMI 0Burner dosing valve: Reading too high· most severe
The EMR4 sees the burner dosing valve (on the exhaust aftertreatment burner fuel line) above its allowed range. The controller treats this as a serious level. Deutz list: KWP code 58, blink code 723.· Real conditionReal conditionCheck soonCauses
- Part driven beyond its limit
- Failed part or a real condition behind the signal
Checks
- 1Read the actual value against the target in SerDia
- 2Check the burner dosing valve moves freely through its range by hand with the key off
- 3Inspect the supply and control wiring of the burner dosing valve for chafe, water and corrosion
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:Exhaust aftertreatment - Burner dosing valve - Data above normal operational range (Most severe level)
Deutz SPN 523911 FMI 4Burner dosing valve: Voltage low / shorted low
The EMR4 sees the output for the burner dosing valve (on the exhaust aftertreatment burner fuel line) at a voltage below normal, as if the circuit is shorted to ground. The controller cannot drive the actuator correctly. Deutz list: KWP code 62, blink code 723.· Shorted lowShorted lowCheck soonCauses
- Output wire chafed to ground or the engine block
- Burner dosing valve winding shorted to its housing
- Water in the connector bridging the pins
Checks
- 1Unplug the burner dosing valve: if the code changes, the part is the shorted one; if it stays, look at the harness
- 2With the EMR4 unplugged, measure the output wire to ground; it should not be low ohms
- 3Measure the winding resistance of the part and look for a very low value
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Exhaust aftertreatment - Burner dosing valve - Voltage below normal or shorted to low source
Deutz SPN 523911 FMI 11Burner dosing valve: Root cause not known
The EMR4 logged a fault on the burner dosing valve (on the exhaust aftertreatment burner fuel line) but could not classify the cause. Test the circuit and the part separately. Deutz list: KWP code 63, blink code 723.· OtherOtherCheck soonCauses
- Intermittent wiring fault
- Failing burner dosing valve
Checks
- 1Read the full SerDia fault list; this code often sits next to a clearer one on the burner dosing valve
- 2Measure the supply and ground at the burner dosing valve plug with the key on to confirm it is powered
- 3Inspect the burner dosing valve plug and harness for chafed insulation, bent pins and moisture
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Burner air pump pressure sensor5 codes
Deutz SPN 523919 FMI 0Burner air pump pressure sensor: Reading too high· most severe
The burner air pump pressure sensor (in the air line between the pump and the burner) reports a value above the allowed range. This is a plausibility limit, so the high value may be genuine rather than a wiring fault. Deutz list: KWP code 755, blink code 6-9-4.· Real conditionReal conditionCheck soonCauses
- Burner air pump pressure sensor drifting high or reading with an offset
- Hose or port feeding the sensor blocked with dirt
Checks
- 1Check the real value against a mechanical gauge or second reading before touching the burner air pump pressure sensor
- 2Compare with its neighbouring sensors in SerDia to see whether only this value is off
- 3Inspect the sensor port or hose for restriction
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:Exhaust aftertreatment - Burner air pump pressure sensor - Data above normal operational range (Most severe level)
Deutz SPN 523919 FMI 1Burner air pump pressure sensor: Reading too low· most severe
The burner air pump pressure sensor (in the air line between the pump and the burner) reports a value below the allowed range. This is a plausibility limit, so the low value may be genuine rather than a wiring fault. Deutz list: KWP code 758, blink code 6-9-4.· Real conditionReal conditionCheck soonCauses
- Burner air pump pressure sensor drifting low or reading with an offset
- Hose or port feeding the sensor split or disconnected
Checks
- 1Check the real value with a mechanical gauge before replacing the burner air pump pressure sensor
- 2Compare with its neighbouring sensors in SerDia to see whether only this value is off
- 3Inspect the sensor port, hose and seal for leaks
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:Exhaust aftertreatment - Burner air pump pressure sensor - Data below normal operational range (Most severe level)
Deutz SPN 523919 FMI 2Burner air pump pressure sensor: Erratic reading
The EMR4 sees the burner air pump pressure sensor (in the air line between the pump and the burner) signal jump or disagree with other values. The signal is present but unstable, which usually means a loose joint or a failing sensor. Deutz list: KWP codes 753 and 1378, blink code 6-9-4.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Intermittent contact in the connector
- Harness chafed against a bracket in a spot that only touches under vibration
- Burner air pump pressure sensor on its way out
Checks
- 1Watch the burner air pump pressure sensor value in SerDia while wiggling the connector and harness
- 2Inspect the connector for loose pins, bent terminals and moisture
- 3Check the 5 V reference for dips while the fault shows
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:Exhaust aftertreatment - Burner air pump pressure sensor - Data erratic intermittent or incorrect
Deutz SPN 523919 FMI 3Burner air pump pressure sensor: Voltage high / shorted high
The EMR4 reads the burner air pump pressure sensor (in the air line between the pump and the burner) signal above its valid 0.5 to 4.5 V window. That points to an open sensor ground, a short to supply on the signal wire, or a failed sensor. Deutz list: KWP code 761, blink code 694.· Shorted highShorted highCheck soonCauses
- Open ground return wire, which pushes the signal up to the reference
- Signal wire touching 5 V or battery in the harness
- Burner air pump pressure sensor failed high
Checks
- 1Key on: measure the 5 V reference at the burner air pump pressure sensor plug between supply and ground; 5 V present means the supply side is fine
- 2Check continuity of the sensor ground wire back to the EMR4 pin
- 3With the sensor unplugged, measure the signal pin; battery voltage there means a short to supply
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Exhaust aftertreatment - Burner air pump pressure sensor - Voltage above normal or shorted to high source
Deutz SPN 523919 FMI 4Burner air pump pressure sensor: Voltage low / shorted low
The EMR4 reads the burner air pump pressure sensor (in the air line between the pump and the burner) signal below its valid 0.5 to 4.5 V window. That points to a shorted signal wire, a lost 5 V reference, or a failed sensor. Deutz list: KWP code 762, blink code 694.· Shorted lowShorted lowCheck soonCauses
- Signal wire rubbed through to ground
- 5 V reference lost: open supply wire or a short on the shared 5 V line
- Burner air pump pressure sensor failed low
Checks
- 1Key on: measure the 5 V reference at the burner air pump pressure sensor plug; no reference means open supply wire or another sensor on that line pulling it down
- 2With the sensor unplugged, measure resistance from the signal pin to ground; it should not be near zero
- 3Unplug other sensors sharing the 5 V line one at a time to see whether the reference comes back
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Exhaust aftertreatment - Burner air pump pressure sensor - Voltage below normal or shorted to low source
Burner exhaust back pressure sensor4 codes
Deutz SPN 523920 FMI 0Burner exhaust back pressure sensor: Reading too high· most severe
The burner exhaust back pressure sensor (at the burner section of the exhaust) reports a value above the allowed range. This is a plausibility limit, so the high value may be genuine rather than a wiring fault. Deutz list: KWP code 765, blink code 7-1-6.· Real conditionReal conditionCheck soonCauses
- Burner exhaust back pressure sensor drifting high or reading with an offset
- Hose or port feeding the sensor blocked with dirt
Checks
- 1Check the real value against a mechanical gauge or second reading before touching the burner exhaust back pressure sensor
- 2Compare with its neighbouring sensors in SerDia to see whether only this value is off
- 3Inspect the sensor port or hose for restriction
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:Exhaust aftertreatment - Burner exhaust back pressure sensor - Data above normal operational range (Most severe level)
Deutz SPN 523920 FMI 2Burner exhaust back pressure sensor: Erratic reading
The EMR4 sees the burner exhaust back pressure sensor (at the burner section of the exhaust) signal jump or disagree with other values. The signal is present but unstable, which usually means a loose joint or a failing sensor. Deutz list: KWP codes 763 and 1379, blink code 7-1-6.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Intermittent contact in the connector
- Harness chafed against a bracket in a spot that only touches under vibration
- Burner exhaust back pressure sensor on its way out
Checks
- 1Watch the burner exhaust back pressure sensor value in SerDia while wiggling the connector and harness
- 2Inspect the connector for loose pins, bent terminals and moisture
- 3Check the 5 V reference for dips while the fault shows
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:Exhaust aftertreatment - Burner exhaust back pressure sensor - Data erratic intermittent or incorrect
Deutz SPN 523920 FMI 3Burner exhaust back pressure sensor: Voltage high / shorted high
The EMR4 reads the burner exhaust back pressure sensor (at the burner section of the exhaust) signal above its valid 0.5 to 4.5 V window. That points to an open sensor ground, a short to supply on the signal wire, or a failed sensor. Deutz list: KWP code 770, blink code 716.· Shorted highShorted highCheck soonCauses
- Open ground return wire, which pushes the signal up to the reference
- Signal wire touching 5 V or battery in the harness
- Burner exhaust back pressure sensor failed high
Checks
- 1Key on: measure the 5 V reference at the burner exhaust back pressure sensor plug between supply and ground; 5 V present means the supply side is fine
- 2Check continuity of the sensor ground wire back to the EMR4 pin
- 3With the sensor unplugged, measure the signal pin; battery voltage there means a short to supply
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Exhaust aftertreatment - Burner exhaust back pressure sensor - Voltage above normal or shorted to high source
Deutz SPN 523920 FMI 4Burner exhaust back pressure sensor: Voltage low / shorted low
The EMR4 reads the burner exhaust back pressure sensor (at the burner section of the exhaust) signal below its valid 0.5 to 4.5 V window. That points to a shorted signal wire, a lost 5 V reference, or a failed sensor. Deutz list: KWP code 771, blink code 716.· Shorted lowShorted lowCheck soonCauses
- Signal wire rubbed through to ground
- 5 V reference lost: open supply wire or a short on the shared 5 V line
- Burner exhaust back pressure sensor failed low
Checks
- 1Key on: measure the 5 V reference at the burner exhaust back pressure sensor plug; no reference means open supply wire or another sensor on that line pulling it down
- 2With the sensor unplugged, measure resistance from the signal pin to ground; it should not be near zero
- 3Unplug other sensors sharing the 5 V line one at a time to see whether the reference comes back
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Exhaust aftertreatment - Burner exhaust back pressure sensor - Voltage below normal or shorted to low source
Burner air pump (Air mass sensor)2 codes
Deutz SPN 524016 FMI 2Burner air pump (Air mass sensor): Erratic reading
The EMR4 sees the burner air pump (Air mass sensor) (in the burner air supply of the aftertreatment system) behave erratically against the command, which can mean a sticking part or an intermittent connection. Deutz list: KWP code 1259, blink code 8-5-9.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Intermittent contact in the connector
- Failed part or a real condition behind the signal
Checks
- 1Command the burner air pump (Air mass sensor) from SerDia and watch actual versus commanded behaviour for lag or dropouts
- 2Wiggle the burner air pump (Air mass sensor) harness and connector while watching the live status in SerDia for dropouts
- 3Check both connector halves of the burner air pump (Air mass sensor) for loose, bent or fretted pins
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:Exhaust aftertreatment - Burner air pump (Air mass sensor) - Data erratic intermittent or incorrect
Deutz SPN 524016 FMI 11Burner air pump (Air mass sensor): Root cause not known
The EMR4 logged a fault on the burner air pump (Air mass sensor) (in the burner air supply of the aftertreatment system) but could not classify the cause. Test the circuit and the part separately. Deutz list: KWP code 1258, blink code 8-5-9.· OtherOtherCheck soonCauses
- Intermittent wiring fault
- Failing burner air pump (Air mass sensor)
Checks
- 1Read the full SerDia fault list; this code often sits next to a clearer one on the burner air pump (Air mass sensor)
- 2Measure the supply and ground at the burner air pump (Air mass sensor) plug with the key on to confirm it is powered
- 3Inspect the burner air pump (Air mass sensor) plug and harness for chafed insulation, bent pins and moisture
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Burner air line blocked1 code
Deutz SPN 524019 FMI 11Burner air line blocked: Root cause not known
The EMR4 logged a fault on the burner air line blocked (in the burner air supply of the aftertreatment system) but could not classify the cause. Test the circuit and the part separately. Deutz list: KWP code 1247, blink code 8-6-2.· Real conditionReal conditionCheck soonCauses
- Intermittent wiring fault
- Failing burner air line blocked
Checks
- 1Read the full SerDia fault list; this code often sits next to a clearer one on the burner air line blocked
- 2Measure the supply and ground at the burner air line blocked plug with the key on to confirm it is powered
- 3Inspect the burner air line blocked plug and harness for chafed insulation, bent pins and moisture
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Shared checks
Checks, in order
- 1Listen for the pump at the start of a burner run and read its status in SerDia
- 2Read the pressure sensors with the engine off and compare them with ambient pressure
- 3Check the air line, the sensor hoses and the filter for blockage and leaks
- 4Compare the back pressure with the DPF differential pressure to see whether the restriction is real
Causes
- Air pump motor worn out or blocked, or its air line kinked, leaking or blocked with soot
- Sensor hose or port blocked by soot or condensate
- Real exhaust restriction raising the back pressure
- Connector corroded or burnt by exhaust heat
Most common here: real condition (6 of 21)
Check the real value with a separate gauge or thermometer before blaming the sensor.
When to stop
You'll notice: A warning lamp or limited function.
Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.