Deutz · Injectors and combustion
Deutz Injector solenoid circuits and banks fault codes
The electrical side of the injectors: the solenoid circuit of each injector and the bank or group lines that drive several injectors together (for example SPN 651, 652 and the bank codes). Each code names the injector or bank and whether the circuit is open, shorted or out of range.
Where to read it
Read the active and stored faults with Deutz SerDia (or the machine maker's diagnostic tool) on the engine diagnostic plug.
What do these codes mean?
Deutz codes SPN 651 FMI 3 to SPN 524001 FMI 5 are all about the injector solenoid circuits and banks. The most common failure type is shorted high (8 of 22); 11 need an immediate stop. Start with this check: measure the solenoid resistance of the injector named in the code against the others.
How urgent are they?
11 of 22 codes here mean stop now; the other 11 can wait until the shift ends, but find the cause before the next one.
- Stop now11
- Check soon11
What should I check first?
Measure the solenoid resistance of the injector named in the code against the others
Shared checks22 of 22
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Injector 12 codes
Deutz SPN 651 FMI 3Injector 1: Voltage high / shorted high
The EMR4 sees the injector for cylinder 1 at a voltage above normal, as if its wiring is shorted to the supply. The controller shuts that injector off to protect the driver stage. Deutz list: KWP code 580, blink code 154. For this code the controller read the injector 1 circuit at a voltage above normal, as if the wire or the driver were pulled up to the supply voltage, for instance by a chafed harness touching a live wire. The code names a single injector, so the circuit between that injector and the EMR4 is the first suspect. The usual symptom is a load that stays energised or never switches off, and the lamp comes on at the next key cycle.· Shorted highShorted highStop nowCauses
- Injector 1 wire shorted to the battery supply
- Solenoid of injector 1 shorted to its body
- Damaged through-connector pin touching a live pin
- Injector driver channel in the EMR4 failing
- Harness insulation worn through where it rubs on a bracket, letting the wire touch a live supply
Checks
- 1Unplug injector 1 at the valve cover with the key on; if the code changes to open, the injector or its cable was the shorted part
- 2With the EMR4 unplugged, measure each injector 1 wire to battery positive; it should be open
- 3Measure the injector 1 coil resistance against the other injectors
- 4Look at the valve cover through-connector for burnt, discoloured or melted pins
- 5Check the cable for worn insulation at the cylinder head
- 6With the EMR4 and the injector 1 unplugged, measure the signal wire against battery positive; it must read open, and any reading means the harness is shorted high.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Engine - Injector 1 - Voltage above normal or shorted to high source
Deutz SPN 651 FMI 5Injector 1: Current low / open circuit
The EMR4 measures too little current through the injector for cylinder 1, so the circuit is open. That cylinder gets no injection pulse and the controller logs the fault against injector 1. Deutz list: KWP code 568, blink code 154. For this code the controller measured too little current in the injector 1 circuit, the signature of an open wire, a pulled-out pin or a burnt-out coil. The code names a single injector, so the circuit between that injector and the EMR4 is the first suspect. The usual symptom is a load that does not respond at all although the controller commands it.· Open circuitOpen circuitStop nowCauses
- A broken wire or a pushed-back pin between the EMR4 and the cylinder 1 injector solenoid
- Injector solenoid coil open inside the injector
- Injector connector under the valve cover not fully latched
- Valve cover through-connector corroded or damaged
- Terminal pushed back or corroded in its connector so the circuit is open
Checks
- 1With the key off, measure the cylinder 1 injector solenoid resistance at the injector terminals; an open coil reads infinite
- 2Check continuity of both injector wires from the valve cover connector to the EMR4 pins
- 3Look for a pin backed out at the EMR4 injector connector
- 4Compare with the other injectors in SerDia to see which cylinder is missing
- 5Inspect the valve cover through-connector for oil, water and corrosion
- 6Check the continuity of both wires between the EMR4 plug and the injector 1 connector, then the coil resistance, to separate a broken wire from a dead coil.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Source wording:Engine - Injector 1 - Current below normal or open circuit
Full page for SPN 651 FMI 5
Injector 22 codes
Deutz SPN 652 FMI 3Injector 2: Voltage high / shorted high
The EMR4 sees the injector for cylinder 2 at a voltage above normal, as if its wiring is shorted to the supply. The controller shuts that injector off to protect the driver stage. Deutz list: KWP code 581, blink code 155. For this code the controller read the injector 2 circuit at a voltage above normal, as if the wire or the driver were pulled up to the supply voltage, for instance by a chafed harness touching a live wire. The code names a single injector, so the circuit between that injector and the EMR4 is the first suspect. The usual symptom is a load that stays energised or never switches off, and the lamp comes on at the next key cycle.· Shorted highShorted highStop nowCauses
- Wiring to injector 2 touching a power wire
- Injector 2 coil shorted
- Insulation worn through at the valve cover
- EMR4 injector output stage damaged
- Harness insulation worn through where it rubs on a bracket, letting the wire touch a live supply
Checks
- 1Remove the injector 2 connector and recheck the code to separate wiring from injector
- 2Measure the high-side wire of injector 2 to supply with the key off
- 3Compare the injector 2 resistance with its neighbours
- 4Check the cable insulation for oil softening and worn spots near the cylinder head
- 5Inspect the valve cover through-connector for water ingress and green corrosion
- 6With the EMR4 and the injector 2 unplugged, measure the signal wire against battery positive; it must read open, and any reading means the harness is shorted high.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Engine - Injector 2 - Voltage above normal or shorted to high source
Deutz SPN 652 FMI 5Injector 2: Current low / open circuit
The EMR4 measures too little current through the injector for cylinder 2, so the circuit is open. That cylinder gets no injection pulse and the controller logs the fault against injector 2. Deutz list: KWP code 569, blink code 155. For this code the controller measured too little current in the injector 2 circuit, the signature of an open wire, a pulled-out pin or a burnt-out coil. The code names a single injector, so the circuit between that injector and the EMR4 is the first suspect. The usual symptom is a load that does not respond at all although the controller commands it.· Open circuitOpen circuitStop nowCauses
- Cable to the cylinder 2 injector chafed through at the cylinder head
- Open coil in the cylinder 2 injector
- Loose injector nut or terminal on the solenoid pin
- Through-connector pin spread from earlier injector work
- Terminal pushed back or corroded in its connector so the circuit is open
Checks
- 1Remove the valve cover and measure the resistance across the injector 2 terminals; open means a dead coil
- 2Test continuity of the two wires from the through-connector to the EMR4 plug
- 3Check that the injector terminal nuts are tight
- 4Run a cylinder cut-out in SerDia and note which cylinder is dead
- 5Look at the connector for crushed or spread pins
- 6Check the continuity of both wires between the EMR4 plug and the injector 2 connector, then the coil resistance, to separate a broken wire from a dead coil.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Source wording:Engine - Injector 2 - Current below normal or open circuit
Injector 32 codes
Deutz SPN 653 FMI 3Injector 3: Voltage high / shorted high
The EMR4 sees the injector for cylinder 3 at a voltage above normal, as if its wiring is shorted to the supply. The controller shuts that injector off to protect the driver stage. Deutz list: KWP code 582, blink code 156. For this code the controller read the injector 3 circuit at a voltage above normal, as if the wire or the driver were pulled up to the supply voltage, for instance by a chafed harness touching a live wire. The code names a single injector, so the circuit between that injector and the EMR4 is the first suspect. The usual symptom is a load that stays energised or never switches off, and the lamp comes on at the next key cycle.· Shorted highShorted highStop nowCauses
- Short to supply on the injector 3 high-side wire
- Faulty solenoid in injector 3
- Oil-soaked cable insulation
- Driver stage fault in the EMR4
- Harness insulation worn through where it rubs on a bracket, letting the wire touch a live supply
Checks
- 1Disconnect injector 3 and see whether the short moves to open circuit
- 2Test the injector 3 wire against the 12 V or 24 V supply for a leak
- 3Measure the coil resistance and compare with neighbours
- 4Check the valve cover through-connector for carbon tracking between pins
- 5Inspect the injector cable where it passes the valve cover seal for crush damage
- 6With the EMR4 and the injector 3 unplugged, measure the signal wire against battery positive; it must read open, and any reading means the harness is shorted high.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Engine - Injector 3 - Voltage above normal or shorted to high source
Deutz SPN 653 FMI 5Injector 3: Current low / open circuit
The EMR4 measures too little current through the injector for cylinder 3, so the circuit is open. That cylinder gets no injection pulse and the controller logs the fault against injector 3. Deutz list: KWP code 570, blink code 156. For this code the controller measured too little current in the injector 3 circuit, the signature of an open wire, a pulled-out pin or a burnt-out coil. The code names a single injector, so the circuit between that injector and the EMR4 is the first suspect. The usual symptom is a load that does not respond at all although the controller commands it.· Open circuitOpen circuitStop nowCauses
- Wire from the engine harness to injector 3 broken near the valve cover seal
- Solenoid winding open in the injector
- Terminal screw on the injector solenoid loose
- Water in the valve cover connector
- Terminal pushed back or corroded in its connector so the circuit is open
Checks
- 1Measure injector 3 coil resistance directly at the injector pins
- 2Check the wire from the through-connector for breaks by flexing it
- 3Check the EMR4 plug for a backed-out pin on this circuit
- 4Confirm in SerDia that cylinder 3 is not firing
- 5Inspect the cover gasket and connector for water
- 6Check the continuity of both wires between the EMR4 plug and the injector 3 connector, then the coil resistance, to separate a broken wire from a dead coil.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Source wording:Engine - Injector 3 - Current below normal or open circuit
Injector 42 codes
Deutz SPN 654 FMI 3Injector 4: Voltage high / shorted high
The EMR4 sees the injector for cylinder 4 at a voltage above normal, as if its wiring is shorted to the supply. The controller shuts that injector off to protect the driver stage. Deutz list: KWP code 583, blink code 161. For this code the controller read the injector 4 circuit at a voltage above normal, as if the wire or the driver were pulled up to the supply voltage, for instance by a chafed harness touching a live wire. The code names a single injector, so the circuit between that injector and the EMR4 is the first suspect. The usual symptom is a load that stays energised or never switches off, and the lamp comes on at the next key cycle.· Shorted highShorted highStop nowCauses
- Injector 4 cable shorted to a live wire inside the harness
- Winding of injector 4 damaged
- Water in the valve cover connector
- EMR4 output stage faulty
- Harness insulation worn through where it rubs on a bracket, letting the wire touch a live supply
Checks
- 1Unplug the through-connector for injector 4 and check the code
- 2Measure the injector 4 wires for any voltage with the key on
- 3Measure the injector coil resistance and compare it with the other injectors on the engine
- 4Look for water or oil inside the valve cover through-connector
- 5Check the injector cable under the valve cover for a crushed or pinched section
- 6With the EMR4 and the injector 4 unplugged, measure the signal wire against battery positive; it must read open, and any reading means the harness is shorted high.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Engine - Injector 4 - Voltage above normal or shorted to high source
Deutz SPN 654 FMI 5Injector 4: Current low / open circuit
The EMR4 measures too little current through the injector for cylinder 4, so the circuit is open. That cylinder gets no injection pulse and the controller logs the fault against injector 4. Deutz list: KWP code 571, blink code 161. For this code the controller measured too little current in the injector 4 circuit, the signature of an open wire, a pulled-out pin or a burnt-out coil. The code names a single injector, so the circuit between that injector and the EMR4 is the first suspect. The usual symptom is a load that does not respond at all although the controller commands it.· Open circuitOpen circuitStop nowCauses
- Injector 4 harness pulled tight and broken when the cover was refitted
- Injector solenoid open from overheating
- Pin at the EMR4 injector plug backed out
- Corrosion in the through-connector
- Terminal pushed back or corroded in its connector so the circuit is open
Checks
- 1Test injector 4 resistance and compare with the neighbouring injectors
- 2Inspect the cable near the cylinder head for crush or heat damage
- 3Check the EMR4 connector pin for this injector for looseness
- 4Run the injector or cylinder cut-out test in SerDia on cylinder 4 and note the response
- 5Look inside the through-connector for corrosion
- 6Check the continuity of both wires between the EMR4 plug and the injector 4 connector, then the coil resistance, to separate a broken wire from a dead coil.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Source wording:Engine - Injector 4 - Current below normal or open circuit
Injector 52 codes
Deutz SPN 655 FMI 3Injector 5: Voltage high / shorted high
The EMR4 sees the output for the injector 5 (under the valve cover of each cylinder) at a voltage above normal, as if the circuit is shorted to the battery supply. The controller cannot drive the actuator correctly. Deutz list: KWP code 584, blink code 162. For this code the controller read the injector 5 circuit at a voltage above normal, as if the wire or the driver were pulled up to the supply voltage, for instance by a chafed harness touching a live wire. The code names a single injector, so the circuit between that injector and the EMR4 is the first suspect. The usual symptom is a load that stays energised or never switches off, and the lamp comes on at the next key cycle.· Shorted highShorted highCheck soonCauses
- Output wire shorted to battery positive
- Connector pin touching a live pin
- Injector 5 shorted internally
- Harness insulation worn through where it rubs on a bracket, letting the wire touch a live supply
Checks
- 1Unplug the injector 5: if the code stays, the short is in the harness or the EMR4; if it clears, the part is the shorted one
- 2With the EMR4 unplugged, measure the output wire to battery positive; it should be open
- 3Measure the winding or coil resistance of the part
- 4With the EMR4 and the injector 5 unplugged, measure the signal wire against battery positive; it must read open, and any reading means the harness is shorted high.
- 5Swap the injector connector with a neighbouring cylinder and see whether the code moves with it.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Engine - Injector 5 - Voltage above normal or shorted to high source
Deutz SPN 655 FMI 5Injector 5: Current low / open circuit
The EMR4 measures too little current through the injector for cylinder 5, so the circuit is open. That cylinder gets no injection pulse and the controller logs the fault against injector 5. Deutz list: KWP code 572, blink code 162. For this code the controller measured too little current in the injector 5 circuit, the signature of an open wire, a pulled-out pin or a burnt-out coil. The code names a single injector, so the circuit between that injector and the EMR4 is the first suspect. The usual symptom is a load that does not respond at all although the controller commands it.· Open circuitOpen circuitStop nowCauses
- Injector 5 cable damaged where it passes the rocker area
- Winding open in injector 5
- Terminal nut loose at the injector
- Connector under the cover wet
- Terminal pushed back or corroded in its connector so the circuit is open
Checks
- 1With the key off, test the resistance across injector 5; open means a failed coil
- 2Check cable continuity between the through-connector and the EMR4
- 3Inspect the injector terminals for loose nuts
- 4Use SerDia to cut out cylinder 5 and check the effect
- 5Look for water or oil inside the valve cover through-connector
- 6Check the continuity of both wires between the EMR4 plug and the injector 5 connector, then the coil resistance, to separate a broken wire from a dead coil.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Source wording:Engine - Injector 5 - Current below normal or open circuit
Injector 62 codes
Deutz SPN 656 FMI 3Injector 6: Voltage high / shorted high
The EMR4 sees the output for the injector 6 (under the valve cover of each cylinder) at a voltage above normal, as if the circuit is shorted to the battery supply. The controller cannot drive the actuator correctly. Deutz list: KWP code 585, blink code 163. For this code the controller read the injector 6 circuit at a voltage above normal, as if the wire or the driver were pulled up to the supply voltage, for instance by a chafed harness touching a live wire. The code names a single injector, so the circuit between that injector and the EMR4 is the first suspect. The usual symptom is a load that stays energised or never switches off, and the lamp comes on at the next key cycle.· Shorted highShorted highCheck soonCauses
- Output wire shorted to battery positive
- Connector pin touching a live pin
- Injector 6 shorted internally
- Harness insulation worn through where it rubs on a bracket, letting the wire touch a live supply
Checks
- 1Unplug the injector 6: if the code stays, the short is in the harness or the EMR4; if it clears, the part is the shorted one
- 2With the EMR4 unplugged, measure the output wire to battery positive; it should be open
- 3Measure the winding or coil resistance of the part
- 4With the EMR4 and the injector 6 unplugged, measure the signal wire against battery positive; it must read open, and any reading means the harness is shorted high.
- 5Swap the injector connector with a neighbouring cylinder and see whether the code moves with it.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Engine - Injector 6 - Voltage above normal or shorted to high source
Deutz SPN 656 FMI 5Injector 6: Current low / open circuit
The EMR4 measures too little current through the injector for cylinder 6, so the circuit is open. That cylinder gets no injection pulse and the controller logs the fault against injector 6. Deutz list: KWP code 573, blink code 163. For this code the controller measured too little current in the injector 6 circuit, the signature of an open wire, a pulled-out pin or a burnt-out coil. The code names a single injector, so the circuit between that injector and the EMR4 is the first suspect. The usual symptom is a load that does not respond at all although the controller commands it.· Open circuitOpen circuitStop nowCauses
- Harness to injector 6 broken near the cover gasket
- Injector 6 solenoid open
- Loose terminal at the injector
- Corroded through-connector pin
- Terminal pushed back or corroded in its connector so the circuit is open
Checks
- 1Check the resistance across the injector 6 terminals for an open coil
- 2Check continuity from the EMR4 to the injector connector
- 3Check the matching pin at the EMR4 injector plug for backing out or a loose crimp
- 4Run the cylinder balance test in SerDia and see whether this cylinder drops out
- 5Inspect the valve cover through-connector for corrosion and spread pins
- 6Check the continuity of both wires between the EMR4 plug and the injector 6 connector, then the coil resistance, to separate a broken wire from a dead coil.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Source wording:Engine - Injector 6 - Current below normal or open circuit
Injector group1 code
Deutz SPN 2797 FMI 4Injector group: Voltage low / shorted low
The EMR4 sees the output for the injector group (in the EMR4 injector power stage and engine harness) at a voltage below normal, as if the circuit is shorted to ground. The controller cannot drive the actuator correctly. Deutz list: KWP codes 1337 and 1339, blink code 565. For this code the controller read the injector group circuit at a voltage below normal, as if it were tied to ground, which points to a wire rubbing through on the frame or a part shorted to its housing. An injector group line drives several injectors together, so a fault on it can take out a whole row at once. The usual symptom is a load that never switches on, a dead function and a lamp after a few seconds.· Shorted lowShorted lowCheck soonCauses
- Output wire chafed to ground or the engine block
- Injector group winding shorted to its housing
- Water in the connector bridging the pins
- Wire pinched against the engine block or frame so the signal is pulled to ground
Checks
- 1Unplug the injector group: if the code changes, the part is the shorted one; if it stays, look at the harness
- 2With the EMR4 unplugged, measure the output wire to ground; it should not be low ohms
- 3Measure the winding resistance of the part and look for a very low value
- 4With the connector unplugged, measure the injector group signal wire against ground; a low resistance means a harness short, while an open reading sends you to the part itself.
- 5Unplug the injectors of that group one at a time and watch whether the code clears.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Engine - Injector group - Voltage below normal or shorted to low source
Injector group 21 code
Deutz SPN 2798 FMI 4Injector group 2: Voltage low / shorted low
The EMR4 sees the output for the injector group 2 (in the EMR4 injector power stage and engine harness) at a voltage below normal, as if the circuit is shorted to ground. The controller cannot drive the actuator correctly. Deutz list: KWP codes 1338 and 1340, blink code 566. For this code the controller read the injector group 2 circuit at a voltage below normal, as if it were tied to ground, which points to a wire rubbing through on the frame or a part shorted to its housing. An injector group line drives several injectors together, so a fault on it can take out a whole row at once. The usual symptom is a load that never switches on, a dead function and a lamp after a few seconds.· Shorted lowShorted lowCheck soonCauses
- Output wire chafed to ground or the engine block
- Injector group 2 winding shorted to its housing
- Water in the connector bridging the pins
- Wire pinched against the engine block or frame so the signal is pulled to ground
Checks
- 1Unplug the injector group 2: if the code changes, the part is the shorted one; if it stays, look at the harness
- 2With the EMR4 unplugged, measure the output wire to ground; it should not be low ohms
- 3Measure the winding resistance of the part and look for a very low value
- 4With the connector unplugged, measure the injector group 2 signal wire against ground; a low resistance means a harness short, while an open reading sends you to the part itself.
- 5Unplug the injectors of that group one at a time and watch whether the code clears.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Engine - Injector group 2 - Voltage below normal or shorted to low source
Injectors bank 11 code
Deutz SPN 523350 FMI 4Injectors bank 1: Voltage low / shorted low
The EMR4 sees injector bank 1 at a voltage below normal, as if the common bank wire is shorted to ground. The banks supply a group of injectors, so more than one cylinder may be affected. Deutz list: KWP code 565, blink code 151. For this code the controller read the injectors bank 1 circuit at a voltage below normal, as if it were tied to ground, which points to a wire rubbing through on the frame or a part shorted to its housing. An injector bank line is a shared power stage output; a short here shows on every injector fed by that bank. The usual symptom is a load that never switches on, a dead function and a lamp after a few seconds.· Shorted lowShorted lowStop nowCauses
- Common bank wire for injector bank 1 shorted to ground
- An injector in bank 1 shorted to its body
- Through-connector under the valve cover wet or burnt
- Injector bank driver in the EMR4 failing
- Wire pinched against the engine block or frame so the signal is pulled to ground
Checks
- 1Unplug the injectors of bank 1 one at a time with the key on to see which one clears the code
- 2With the EMR4 unplugged, measure the bank 1 wire to ground; it should be open
- 3Measure each injector coil resistance in bank 1 against the others
- 4Inspect the valve cover through-connector for water and burnt pins
- 5Check the harness for chafe where it crosses the cylinder head
- 6With the connector unplugged, measure the injectors bank 1 signal wire against ground; a low resistance means a harness short, while an open reading sends you to the part itself.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Engine - Injectors bank 1 - Voltage below normal or shorted to low source
Full page for SPN 523350 FMI 4
Injectors bank 21 code
Deutz SPN 523352 FMI 4Injectors bank 2: Voltage low / shorted low
The EMR4 sees the output for the injectors bank 2 (in the EMR4 injector power stage and engine harness) at a voltage below normal, as if the circuit is shorted to ground. The controller cannot drive the actuator correctly. Deutz list: KWP code 566, blink code 152. For this code the controller read the injectors bank 2 circuit at a voltage below normal, as if it were tied to ground, which points to a wire rubbing through on the frame or a part shorted to its housing. An injector bank line is a shared power stage output; a short here shows on every injector fed by that bank. The usual symptom is a load that never switches on, a dead function and a lamp after a few seconds.· Shorted lowShorted lowCheck soonCauses
- Output wire chafed to ground or the engine block
- Injectors bank 2 winding shorted to its housing
- Water in the connector bridging the pins
- Wire pinched against the engine block or frame so the signal is pulled to ground
Checks
- 1Unplug the injectors bank 2: if the code changes, the part is the shorted one; if it stays, look at the harness
- 2With the EMR4 unplugged, measure the output wire to ground; it should not be low ohms
- 3Measure the winding resistance of the part and look for a very low value
- 4With the connector unplugged, measure the injectors bank 2 signal wire against ground; a low resistance means a harness short, while an open reading sends you to the part itself.
- 5Unplug the injectors of the bank one by one and watch which one clears the code.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Engine - Injectors bank 2 - Voltage below normal or shorted to low source
Injectors bank 1 Secondary1 code
Deutz SPN 523997 FMI 4Injectors bank 1 Secondary: Voltage low / shorted low
The EMR4 sees the output for the injectors bank 1 Secondary (in the EMR4 injector power stage and engine harness) at a voltage below normal, as if the circuit is shorted to ground. The controller cannot drive the actuator correctly. Deutz list: KWP code 1326, blink code 7-9-7. For this code the controller read the injectors bank 1 Secondary circuit at a voltage below normal, as if it were tied to ground, which points to a wire rubbing through on the frame or a part shorted to its housing. An injector bank line is a shared power stage output; a short here shows on every injector fed by that bank. The usual symptom is a load that never switches on, a dead function and a lamp after a few seconds.· Shorted lowShorted lowCheck soonCauses
- Output wire chafed to ground or the engine block
- Injectors bank 1 Secondary winding shorted to its housing
- Water in the connector bridging the pins
- Wire pinched against the engine block or frame so the signal is pulled to ground
Checks
- 1Unplug the injectors bank 1 Secondary: if the code changes, the part is the shorted one; if it stays, look at the harness
- 2With the EMR4 unplugged, measure the output wire to ground; it should not be low ohms
- 3Measure the winding resistance of the part and look for a very low value
- 4With the connector unplugged, measure the injectors bank 1 Secondary signal wire against ground; a low resistance means a harness short, while an open reading sends you to the part itself.
- 5Unplug the injectors of the bank one by one and watch which one clears the code.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Engine - Injectors bank 1 Secondary - Voltage below normal or shorted to low source
Injectors bank 2 Secondary1 code
Deutz SPN 523998 FMI 4Injectors bank 2 Secondary: Voltage low / shorted low
The EMR4 sees the output for the injectors bank 2 Secondary (in the EMR4 injector power stage and engine harness) at a voltage below normal, as if the circuit is shorted to ground. The controller cannot drive the actuator correctly. Deutz list: KWP code 1327, blink code 7-9-8. For this code the controller read the injectors bank 2 Secondary circuit at a voltage below normal, as if it were tied to ground, which points to a wire rubbing through on the frame or a part shorted to its housing. An injector bank line is a shared power stage output; a short here shows on every injector fed by that bank. The usual symptom is a load that never switches on, a dead function and a lamp after a few seconds.· Shorted lowShorted lowCheck soonCauses
- Output wire chafed to ground or the engine block
- Injectors bank 2 Secondary winding shorted to its housing
- Water in the connector bridging the pins
- Wire pinched against the engine block or frame so the signal is pulled to ground
Checks
- 1Unplug the injectors bank 2 Secondary: if the code changes, the part is the shorted one; if it stays, look at the harness
- 2With the EMR4 unplugged, measure the output wire to ground; it should not be low ohms
- 3Measure the winding resistance of the part and look for a very low value
- 4With the connector unplugged, measure the injectors bank 2 Secondary signal wire against ground; a low resistance means a harness short, while an open reading sends you to the part itself.
- 5Unplug the injectors of the bank one by one and watch which one clears the code.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Engine - Injectors bank 2 Secondary - Voltage below normal or shorted to low source
Injector 72 codes
Deutz SPN 524000 FMI 3Injector 7: Voltage high / shorted high
The EMR4 sees the output for the injector 7 (under the valve cover of each cylinder) at a voltage above normal, as if the circuit is shorted to the battery supply. The controller cannot drive the actuator correctly. Deutz list: KWP code 1333, blink code 1-7-7. For this code the controller read the injector 7 circuit at a voltage above normal, as if the wire or the driver were pulled up to the supply voltage, for instance by a chafed harness touching a live wire. The code names a single injector, so the circuit between that injector and the EMR4 is the first suspect. The usual symptom is a load that stays energised or never switches off, and the lamp comes on at the next key cycle.· Shorted highShorted highCheck soonCauses
- Output wire shorted to battery positive
- Connector pin touching a live pin
- Injector 7 shorted internally
- Harness insulation worn through where it rubs on a bracket, letting the wire touch a live supply
Checks
- 1Unplug the injector 7: if the code stays, the short is in the harness or the EMR4; if it clears, the part is the shorted one
- 2With the EMR4 unplugged, measure the output wire to battery positive; it should be open
- 3Measure the winding or coil resistance of the part
- 4With the EMR4 and the injector 7 unplugged, measure the signal wire against battery positive; it must read open, and any reading means the harness is shorted high.
- 5Swap the injector connector with a neighbouring cylinder and see whether the code moves with it.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Engine - Injector 7 - Voltage above normal or shorted to high source
Deutz SPN 524000 FMI 5Injector 7: Current low / open circuit
The EMR4 sees too little current through the injector 7 (under the valve cover of each cylinder), which means the circuit is open. The controller commands the actuator but nothing flows. Deutz list: KWP code 1329, blink code 1-7-7. For this code the controller measured too little current in the injector 7 circuit, the signature of an open wire, a pulled-out pin or a burnt-out coil. The code names a single injector, so the circuit between that injector and the EMR4 is the first suspect. The usual symptom is a load that does not respond at all although the controller commands it.· Open circuitOpen circuitCheck soonCauses
- Broken wire or a pin pushed out of the connector
- Injector 7 winding open
- Connector left unplugged after earlier work
- Terminal pushed back or corroded in its connector so the circuit is open
Checks
- 1Measure the resistance across the injector 7 terminals: infinity means an open winding
- 2Continuity-test each wire to the matching EMR4 pin
- 3Inspect both ends of the injector 7 circuit (EMR4 plug and part connector) for pins pushed back in the housing
- 4Check the continuity of both wires between the EMR4 plug and the injector 7 connector, then the coil resistance, to separate a broken wire from a dead coil.
- 5Swap the injector connector with a neighbouring cylinder and see whether the code moves with it.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Source wording:Engine - Injector 7 - Current below normal or open circuit
Injector 82 codes
Deutz SPN 524001 FMI 3Injector 8: Voltage high / shorted high
The EMR4 sees the output for the injector 8 (under the valve cover of each cylinder) at a voltage above normal, as if the circuit is shorted to the battery supply. The controller cannot drive the actuator correctly. Deutz list: KWP code 1334, blink code 1-7-8. For this code the controller read the injector 8 circuit at a voltage above normal, as if the wire or the driver were pulled up to the supply voltage, for instance by a chafed harness touching a live wire. The code names a single injector, so the circuit between that injector and the EMR4 is the first suspect. The usual symptom is a load that stays energised or never switches off, and the lamp comes on at the next key cycle.· Shorted highShorted highCheck soonCauses
- Output wire shorted to battery positive
- Connector pin touching a live pin
- Injector 8 shorted internally
- Harness insulation worn through where it rubs on a bracket, letting the wire touch a live supply
Checks
- 1Unplug the injector 8: if the code stays, the short is in the harness or the EMR4; if it clears, the part is the shorted one
- 2With the EMR4 unplugged, measure the output wire to battery positive; it should be open
- 3Measure the winding or coil resistance of the part
- 4With the EMR4 and the injector 8 unplugged, measure the signal wire against battery positive; it must read open, and any reading means the harness is shorted high.
- 5Swap the injector connector with a neighbouring cylinder and see whether the code moves with it.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Engine - Injector 8 - Voltage above normal or shorted to high source
Deutz SPN 524001 FMI 5Injector 8: Current low / open circuit
The EMR4 sees too little current through the injector 8 (under the valve cover of each cylinder), which means the circuit is open. The controller commands the actuator but nothing flows. Deutz list: KWP code 1330, blink code 1-7-8. For this code the controller measured too little current in the injector 8 circuit, the signature of an open wire, a pulled-out pin or a burnt-out coil. The code names a single injector, so the circuit between that injector and the EMR4 is the first suspect. The usual symptom is a load that does not respond at all although the controller commands it.· Open circuitOpen circuitCheck soonCauses
- Broken wire or a pin pushed out of the connector
- Injector 8 winding open
- Connector left unplugged after earlier work
- Terminal pushed back or corroded in its connector so the circuit is open
Checks
- 1Measure the resistance across the injector 8 terminals: infinity means an open winding
- 2Continuity-test each wire to the matching EMR4 pin
- 3Inspect both ends of the injector 8 circuit (EMR4 plug and part connector) for pins pushed back in the housing
- 4Check the continuity of both wires between the EMR4 plug and the injector 8 connector, then the coil resistance, to separate a broken wire from a dead coil.
- 5Swap the injector connector with a neighbouring cylinder and see whether the code moves with it.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Source wording:Engine - Injector 8 - Current below normal or open circuit
Shared checks
Checks, in order
- 1Measure the solenoid resistance of the injector named in the code against the others
- 2Swap the injector connector with a neighbour and see whether the code follows
- 3Inspect the harness and connector under the valve cover for oil and chafing
- 4Check the bank line for a short to supply or ground with the EMR4 unplugged
- 5Run a cylinder balance test and read the injector data list in SerDia
Causes
- Injector solenoid open or shorted
- Injector connector under the valve cover wet, oily or damaged
- Harness chafed where it crosses the cylinder head
- Bank line shorted to supply or ground
Most common here: shorted high (8 of 22)
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
When to stop
You'll notice: A warning lamp or limited function.
Common-rail fuel runs at very high pressure. Never open a high-pressure line or fitting with the engine running or just after it stops - a fine fuel jet can pierce skin.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.
