EF Logo

Deutz · CAN communication and shutdown

Deutz Other CAN messages, special instructions and burner pump messages fault codes

The remaining CAN messages: the AGS aftertreatment messages, engine protection, functional mode, engine brake, pre-heating, ambient data, wheel speed, hydraulic start-stop, the oil level sensor, the burner pump status messages, and the CAN special instructions that the Deutz list gives only a short text. The code name says which message timed out or was invalid.

FaultCheckSPN 639FMI 14Deutz · Machine - CAN
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Read the active and stored faults with Deutz SerDia (or the machine maker's diagnostic tool) on the engine diagnostic plug.

What do these codes mean?

Deutz codes SPN 639 FMI 14 to SPN 524280 FMI 8 are all about the other CAN messages, special instructions and burner pump messages. Most are lost message faults; none needs an immediate stop. Start with this check: identify the sending unit from the code name and read its own fault list first.

How urgent are they?

None of the 22 codes here means stop now; 19 can wait until the shift ends, but find the cause before the next one; 3 are information only.

  • Check soon19
  • Info3

What should I check first?

Identify the sending unit from the code name and read its own fault list first

Shared checks

22 of 22

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Machine - CAN3 codes

    • Deutz SPN 639 FMI 14Machine - CAN: Special instructions

      The EMR4 flags the J1939 network 1 (SPN 639) as special instructions.· Lost message
      Check soon

      Causes

      • CAN-H or CAN-L wiring fault
      • Terminating resistor missing
      • A node on the bus sending bad messages
      • Low supply voltage at a controller

      Checks

      1. 1Measure the resistance between CAN-H and CAN-L at the diagnostic plug; about 60 ohms means two terminators are present
      2. 2Check the CAN wires for chafing or a pinched section in the machine harness
      3. 3Disconnect machine nodes one at a time to find one that floods or disturbs the bus
      4. 4Check supply voltage at the machine controllers, since low voltage makes nodes drop off the bus
      5. 5Read the freeze frame and the other active codes to see what produced it.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 1231 FMI 14Machine - CAN: Special instructions

      Same fault as SPN 639 FMI 14 for the CAN message.· Lost message
      Info

      Causes

      • CAN-H or CAN-L wiring fault
      • Terminating resistor missing

      Checks

      1. 1Read the freeze frame and the other active codes to see what produced it.
      2. 2Measure the resistance between CAN-H and CAN-L at the diagnostic plug; about 60 ohms means two terminators are present
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 1235 FMI 14Machine - CAN: Special instructions

      Same fault as SPN 639 FMI 14 for the CAN message.· Lost message
      Info

      Causes

      • CAN-H or CAN-L wiring fault
      • Terminating resistor missing

      Checks

      1. 1Read the freeze frame and the other active codes to see what produced it.
      2. 2Measure the resistance between CAN-H and CAN-L at the diagnostic plug; about 60 ohms means two terminators are present
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Engine - CAN engine brake1 code

    • Deutz SPN 523211 FMI 9Engine - CAN engine brake: Abnormal update rate timeout

      The EMR4 did not receive the CAN engine brake (received over the machine CAN bus) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Check the retarder or brake controller sending it.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Engine - CAN engine protection1 code

    • Deutz SPN 523212 FMI 9Engine - CAN engine protection: Abnormal update rate timeout

      The EMR4 reports a timeout of the CAN engine protection message.· Lost message
      Check soon

      Causes

      • Machine controller not sending
      • CAN wiring fault
      • Wrong configuration

      Checks

      1. 1Check the supply and ground of the machine controller that sends the engine protection message
      2. 2Measure CAN-H to CAN-L resistance at the diagnostic plug and check the terminators
      3. 3Use SerDia to monitor whether the protection message arrives
      4. 4Check the machine wiring diagram for the controller that is meant to send this message
      5. 5Read what the machine protection logic is requesting.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Engine - CAN pre heating1 code

    • Deutz SPN 523216 FMI 9Engine - CAN pre heating: Abnormal update rate timeout

      The EMR4 did not receive the CAN pre heating (received over the machine CAN bus) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Check the preheat controller on the machine.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Engine - CAN Functional mode control1 code

    • Deutz SPN 523240 FMI 9Engine - CAN Functional mode control: Abnormal update rate timeout

      The EMR4 reports a timeout of the CAN functional mode control message.· Lost message
      Check soon

      Causes

      • Machine controller not sending
      • CAN wiring fault
      • Configuration mismatch

      Checks

      1. 1Check the supply and ground of the machine controller that sends the functional mode request
      2. 2Measure CAN-H to CAN-L resistance at the diagnostic plug and check the terminators
      3. 3Monitor the functional mode message in SerDia while changing machine mode
      4. 4Check that the machine controller software matches the engine configuration
      5. 5Check the machine controller sending the mode.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Engine - CAN ambient temperature1 code

    • Deutz SPN 523603 FMI 9Engine - CAN ambient temperature: Abnormal update rate timeout

      The EMR4 did not receive the CAN ambient temperature (received over the machine CAN bus) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Check the machine ambient sensor and its controller.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Engine - CAN ambient conditions1 code

    • Deutz SPN 523717 FMI 12Engine - CAN ambient conditions: Bad device or component

      The EMR4 judges the CAN ambient conditions (received over the machine CAN bus) to be a bad device.· Part or controller
      Check soon

      Causes

      • Internal failure of the part or its electronics
      • Water, soot or dirt inside the part

      Checks

      1. 1Read the CAN ambient conditions status in SerDia and run any available actuator or component test
      2. 2Check supply voltage and ground at the connector with the key on to confirm it is powered
      3. 3Check the machine controller that sends the ambient data.
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Engine - CAN ambient conditions - Bad intelligent device or component

  • Engine - CAN AGS2 codes

    • Deutz SPN 523793 FMI 9Engine - CAN AGS: Abnormal update rate timeout

      The EMR4 did not receive the CAN AGS (sent over CAN by the aftertreatment system) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Read the AGS control unit own fault list.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 523794 FMI 9Engine - CAN AGS: Abnormal update rate timeout

      Same fault as SPN 523793 FMI 9 for the CAN AGS message.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off

      Checks

      1. 1Read the AGS control unit own fault list.
      2. 2Check the supply and ground of the sending control unit with the key on
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Engine - CAN AGS purification1 code

    • Deutz SPN 523858 FMI 12Engine - CAN AGS purification: Bad device or component

      The EMR4 judges the CAN AGS purification (sent over CAN by the aftertreatment system) to be a bad device.· Part or controller
      Check soon

      Causes

      • Internal failure of the part or its electronics
      • Water, soot or dirt inside the part

      Checks

      1. 1Read the CAN AGS purification status in SerDia and run any available actuator or component test
      2. 2Check supply voltage and ground at the connector with the key on to confirm it is powered
      3. 3Read the AGS control unit own fault list.
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Engine - CAN AGS purification - Bad intelligent device or component

  • Engine - CAN AGS burner air pump1 code

    • Deutz SPN 523867 FMI 12Engine - CAN AGS burner air pump: Bad device or component

      The EMR4 judges the CAN AGS burner air pump (sent over CAN by the aftertreatment system) to be a bad device.· Part or controller
      Check soon

      Causes

      • Internal failure of the part or its electronics
      • Water, soot or dirt inside the part

      Checks

      1. 1Read the CAN AGS burner air pump status in SerDia and run any available actuator or component test
      2. 2Check supply voltage and ground at the connector with the key on to confirm it is powered
      3. 3Check the burner air pump and its control.
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Engine - CAN AGS burner air pump - Bad intelligent device or component

  • Exhaust aftertreatment - CAN Burner pump2 codes

    • Deutz SPN 524097 FMI 9Exhaust aftertreatment - CAN Burner pump: Abnormal update rate timeout

      The EMR4 did not receive the CAN Burner pump (sent over CAN by the burner controller) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Check the burner controller supply.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 524098 FMI 9Exhaust aftertreatment - CAN Burner pump: Abnormal update rate timeout

      Same fault as SPN 524097 FMI 9 for the CAN Burner pump message.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off

      Checks

      1. 1Check the burner controller supply.
      2. 2Check the supply and ground of the sending control unit with the key on
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Exhaust aftertreatment - CAN Burner air pump1 code

    • Deutz SPN 524103 FMI 9Exhaust aftertreatment - CAN Burner air pump: Abnormal update rate timeout

      The EMR4 did not receive the CAN Burner air pump (sent over CAN by the burner controller) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Check the burner controller supply.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Engine - CAN EGS sensor1 code

    • Deutz SPN 524105 FMI 9Engine - CAN EGS sensor: Abnormal update rate timeout

      The EMR4 did not receive the CAN EGS sensor (received over the machine CAN bus) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Check the sensor module plug.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Machine - CAN wheel speed1 code

    • Deutz SPN 524156 FMI 9Machine - CAN wheel speed: Abnormal update rate timeout

      The EMR4 did not receive the CAN wheel speed (received over the machine CAN bus) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Check the machine controller that sends wheel speed.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Manufacturer Assignable SPN2 codes

    • Deutz SPN 524268 FMI 9Manufacturer Assignable SPN: Abnormal update rate timeout

      The EMR4 did not receive the manufacturer Assignable SPN (received over the machine CAN bus) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Ask the machine maker which function this message serves.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 524272 FMI 14Manufacturer Assignable SPN: Special instructions

      The EMR4 flags the manufacturer Assignable SPN (event raised by the CAN communication of the EMR4) as a special instruction case.· Lost message
      Info

      Causes

      • A running condition that the EMR4 monitors has been reached
      • An earlier fault left a stored special instruction

      Checks

      1. 1Read the full SerDia list and the freeze frame data
      2. 2Check the machine service manual for the instruction that belongs to this condition
      3. 3Read the freeze frame.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Engine - CAN Hydraulic Start Stop1 code

    • Deutz SPN 524269 FMI 9Engine - CAN Hydraulic Start Stop: Abnormal update rate timeout

      The EMR4 did not receive the CAN Hydraulic Start Stop (received over the machine CAN bus) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Check the machine controller for the stop-start request.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Engine - CAN oil level sensor1 code

    • Deutz SPN 524280 FMI 8Engine - CAN oil level sensor: Abnormal frequency / pulse width

      The EMR4 sees the CAN oil level sensor (received over the machine CAN bus) arriving with an abnormal rate or timing.· Erratic or implausible
      Check soon

      Causes

      • Heavy load or errors on the CAN bus
      • Sender running at a wrong rate

      Checks

      1. 1Read the CAN bus load in the service tool, if available
      2. 2Inspect the CAN wiring and connectors for faults
      3. 3Check the oil level sensor and its wiring.
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Engine - CAN oil level sensor - Abnormal frequency or pulse width or period

Shared checks

Checks, in order

  1. 1Identify the sending unit from the code name and read its own fault list first
  2. 2Confirm the machine really fits the function; a message the machine never sends is expected after a dataset change
  3. 3Compare the dataset versions of the sender and the EMR4 where the tool shows them
  4. 4Inspect the CAN stub and plug of the sending unit for corrosion and loose pins

Causes

  • The sending control unit does not transmit that message with the software it carries, or has no key-on supply
  • CAN stub or splice to the sending unit corroded or loose
  • Message layout changed after a dataset change on one of the controllers
  • Bus-off state of a CAN node after a short on the line that was later cleared

Most codes here: lost message (18 of 22)

Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

When to stop

You'll notice: A warning lamp or limited function.

Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.